J Thorac Cardiovasc Surg 2006;131:730-731
© 2006 The American Association for Thoracic Surgery
Brief Communication |
a Department of Cardiovascular Surgery, German Heart Center Munich, Germany
b Department of Anesthesiology, German Heart Center Munich, Germany
Received for publication October 7, 2005; accepted for publication October 26, 2005. * Address for reprints: Walter B. Eichinger, MD, PhD, Department of Cardiovascular Surgery, Lazarettstr 36, 80636 Munich, Germany (Email: eichinger@dhm.mhn.de).
| The first 20% of the full text of this article appears below. |
The Medtronic ADVANTAGE prosthesis (Medtronic, Inc, Minneapolis, Minn) is a new bileaflet mechanical heart valve. The multicenter clinical trial to obtain worldwide regulatory approvals for the device began in November 1999. Currently, the study continues with the follow-up of all enrolled patients until US Food and Drug Administration approval is granted. In our series containing 61 study patients and 2 patients outside the study with an aortic prosthesis, we echocardiographically observed an intermittent regurgitation in 7 patients. The intermittent trivial to moderate aortic regurgitation occurring 1
This article has been cited by other articles:
![]() |
W. B. Eichinger, I. Hettich, S. Bleiziffer, R. Gunzinger, A. Hutter, R. Bauernschmitt, and R. Lange Intermittent regurgitation caused by incomplete leaflet closure of the Medtronic ADVANTAGE bileaflet heart valve: Analysis of the underlying mechanism J. Thorac. Cardiovasc. Surg., September 1, 2010; 140(3): 611 - 616. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Guenzinger, W. B. Eichinger, I. Hettich, S. Bleiziffer, D. Ruzicka, R. Bauernschmitt, and R. Lange A prospective randomized comparison of the Medtronic Advantage Supra and St Jude Medical Regent mechanical heart valves in the aortic position: is there an additional benefit of supra-annular valve positioning? J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 462 - 471. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Haaverstad, N. Vitale, A. Tromsdal, K. Hegbom, and A. Karevold Intermittent incomplete closure of Medtronic Advantage aortic valve leaflets causes unnecessary reoperation J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 791 - 792. [Full Text] [PDF] |
||||
![]() |
R. Haaverstad, N. Vitale, A. Karevold, G. Cappabianca, A. Tromsdal, P. S. Olsen, L. Kober, H. Ihlen, K. A. Rein, and J. L Svennevig Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study Heart, April 1, 2007; 93(4): 500 - 505. [Abstract] [Full Text] [PDF] |
||||