J Thorac Cardiovasc Surg 2006;132:989-990
© 2006 The American Association for Thoracic Surgery
Letter to the Editor |
"A. De Gasperis" Cardiac surgery Division, Niguarda Ca' Granda Hospital, Piazza Ospedale Maggiore 3, Milan 20162, Italy
(Email: agaratti@tiscali.it).
| The first 20% of the full text of this article appears below. |
To the Editor:
We read with great interest the article of Strauch and colleagues1
regarding their experience with Impella Recover LD support for postcardiotomy low-output syndrome in a patient undergoing aortic valve replacement with a bioprosthesis. In our initial experience2
we reported the use of the Impella Recover LD to support a patient with valvular cardiomyopathy who underwent conventional mitral valve repair and aortic valve replacement with a 21 mm Carpentier-Edwards bioprosthesis. Despite maximal inotropic support (epinephrine dose, 0.2 µg/kg–1/min–1), the patient could not be weaned from extracorporeal circulation, with hypotension, increased filling pressure (left atrial pressure, 28 mm Hg), and oliguria
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |