JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Piet G. M. Jansen
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jansen, P. G. M.
Right arrow Articles by Wildevuur, C. R. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jansen, P. G. M.
Right arrow Articles by Wildevuur, C. R. H.

J Thorac Cardiovasc Surg 1995;110:829-0834
© 1995 Mosby, Inc.


CARDIOPULMONARY BYPASS,
MYOCARDIAL MANAGEMENT, AND SUPPORT TECHNIQUES

Reduced complement activation and improved postoperative performance after cardiopulmonary bypass with heparin-coated circuits

Piet G. M. Jansen, MD, PhDa, Henk te Velthuis, PhDa, Rien A. J. M. Huybregts, MDa, Reginald Paulus, CPa, Eisso R. Bulder, MDb, Hans I. van der Spoel, MDc, P. Dick Bezemer, PhDd, Ed H. Slaats, PhDe, León Eijsman, MD, PhDa, Charles R. H. Wildevuur, MD, PhDa

Amsterdam, The Netherlands

Supported in part by Bentley Laboratories Europe BV, Uden, The Netherlands.

Received for publication July 25, 1994. Accepted for publication Dec. 23, 1994. Address for reprints: P. G. M. Jansen, MD, PhD, Department of Cardiac surgery–L322, Free University Hospital, P.O. Box 7057, 1007 MB Amsterdam, The Netherlands.

Abstract

A randomized controlled trial that involved 30 patients undergoing elective coronary artery bypass grafting was done to determine the effect of heparin-coated circuits and full heparinization on complement activation, neutrophil-mediated inflammatory response, and postoperative clinical recovery. Peak concentrations of terminal complement complex were 38% lower (p = 0.004) in 15 patients treated with heparin-coated circuits (median 775 µg/L, interquartile range 600 to 996) compared with those in 15 patients treated with uncoated circuits (median 1249 µg/L, interquartile range 988 to 1443). Although no significant intergroup differences in concentrations of polymorphonuclear neutrophil elastase were found, a positive correlation (rs = 0.74, p < 0.0007) was calculated between peak concentrations of terminal complement complex and polymorphonuclear neutrophil elastase. Differences in patient recovery were analyzed with use of a score composed of fluid balance, postoperative intubation time, and the difference between rectal temperature and skin temperature. The score was significantly lower in patients treated with heparin-coated circuits (p = 0.03), whereas its components showed no intergroup significance. We conclude that the use of heparin-coated circuits with full systemic heparinization results in improved biocompatibility, as assessed by complement activation, and leads to an improved postoperative recovery of the patient. (J THORACCARDIOVASCSURG1995;110: 829-34)

The use of extracorporeal circulation circuits still contributes to the morbidity of cardiac operations. Exposure of blood to the artificial surfaces of the extracorporeal circuit during cardiopulmonary bypass (CPB) results in plasmatic and cellular activation of the host defense mechanism.Go 1 Activation of the complement cascade during CPB takes place predominantly through the alternative pathway and results in activation of C3, which in turn generates an amplifying C3 convertase complex.Go Go 2,3 These enzymatic complexes activate the terminal complement pathway with the formation of C5a and C5b-9 or terminal complement complex (TCC). Deposition of pore-forming TCC on erythrocytes during CPB has been associated with hemolysis and bondage of TCC on granulocytes may result in activation of the latter.Go 4 Clinical studies have shown that the morbidity and the occurrence of adverse events of CPB are associated with the degree of complement activation.Go Go 5,6 In this regard, it has been suggested that the biocompatibility of extracorporeal circuits be assessed by the degree of complement activation, specifically TCC.Go Go 7,8

Heparin surface-coating of CPB circuits was originally introduced to enable reduction or even elimination of systemic heparinization. With strict regulations to prevent low-flow areas in the circuit, low-dose heparinization has been practiced safely for specific indications with significant reductions of blood loss and blood requirements.Go 9 Several clinical studies have demonstrated reduced complement activation and lower levels of inflammatory mediators in patients treated with reduced systemic heparinization and heparin-coated circuits.Go Go 10-13 However, these studies did not report on improvements in the postoperative clinical recovery of the patients associated with a clear reduction in inflammatory mediators, which should be essential in the assessment of improved biocompatibility.

The aim of this study was to determine whether the use of heparin-coated circuits and full systemic heparinization improves the biocompatibility of the circuit with respect to reduced complement activation during CPB and whether this reduction corresponds with a reduction in leukocyte-mediated inflammatory response and an improved postoperative clinical recovery. Therefore we measured plasma levels of TCC and polymorphonuclear neutrophil elastase (PMN elastase) during and after CPB. To quantitate the postoperative clinical recovery a carefully chosen score was used. This score is composed of a combination of clinical parameters representing the inflammatory response in the intensive care unit (ICU): the rectal and peripheral skin temperature, the fluid balance, and the intubation time.

PATIENTS AND METHODS

Design of the study
A standardized group of 30 patients undergoing elective first-time coronary artery bypass grafting (CABG) was studied to minimize interfering sources of blood activation. When significant changes can be determined in such a low-risk population, a more pronounced effect might be expected in patients with high-risk conditions undergoing CPB. Inclusion criteria were left ventricular end-diastolic pressure less than 25 mm Hg and acetylsalicylic acid stopped for more than 3 days. Patients with preoperative coagulopathy or impaired organ function other than myocardial ischemia and those receiving antiinflammatory drugs were excluded. The patients were randomly allocated to be treated with either a heparin-coated circuit (n = 15) or an uncoated circuit (n = 15). Physicians involved in patient care and biochemists were blinded for randomization. Informed consent was obtained from each patient and the study was approved by the Medical Ethics Committee of the Free University Hospital.

Anesthesia and CPB
On the morning of the operation, patients received their usual early-morning dose of antianginal medication and lorazepam 5 mg. Anesthesia was induced with intravenous sufentanil citrate 3 µg/kg, pancuronium bromide 0.1 mg/kg, and midazolam 0.1 mg/kg and maintained by supplemental doses of these drugs. Cefuroxime 1500 mg was given intravenously for infection prophylaxis. After endotracheal intubation, patients received mechanical ventilation of the lungs to normocapnia with an oxygen and air mixture. Radial artery and thermodilution pulmonary artery catheters were placed for hemodynamic measurements and procurement of blood samples.

The extracorporeal circulation circuit consisted of a soft-shell venous reservoir, roller pump, membrane oxygenator (Univox, Baxter Healthcare Corp., Irvine, Calif.), arterial line filter, cardiotomy reservoir, and polyvinyl tubing system. In the heparin-coated group, all parts of the extracorporeal circuit were treated with surface-bonded heparin (Duraflo II, Baxter). The total priming volume of the system was 1400 ml and consisted of 1250 ml lactated Ringer's solution, 100 ml 20% mannitol, 50 ml 8.4% sodium bicarbonate, and 5000 IE heparin. For the performance of subtotal CPB, a standard cannulation technique was used with cannulas placed in the ascending aorta and right atrium (two-stage venous cannula). After systemic heparinization (300 IU/kg) was accomplished, CPB was initiated when the activated clotting time was longer than 400 seconds. The left ventricle was vented via the aortic root. Blood from the pericardial cavity was collected in a cardiotomy reservoir and returned to the patient. The hematocrit value during CPB was maintained at 22% to 23%; if possible, autologous blood was taken from the patient from the venous cannula just before the onset of extracorporeal circulation. A nonpulsatile flow rate was maintained at 2.2 to 2.4 L · min-1 · m-2 andpatients were cooled to 29° to 30° C nasopharyngeal temperature. After the aorta was crossclamped, all patients received high-potassium (16 mmol/L), cold crystalloid cardioplegic solution (800 to 1000 ml, 4° C) for myocardial protection. Distal anastomoses of the grafts were placed during aortic crossclamping, and proximal anastomoses were constructed after aortic crossclamp release and restored mechanical ventilation. Acid-base balance was managed according to the alpha-stat concept. Patients were weaned from CPB with the use of inotropic support if necessary. After termination of CPB, heparin was neutralized by an equal dose of protamine sulfate (3 mg/kg). Autologous blood and residual volume from the extracorporeal circuit were infused in the patient as first-choice fluid administration.

Postoperative care
After the operation, all patients were transferred to the ICU, where they were treated according to a standardized protocol. Hemodynamic goals were heart rate 70 to 80 beats/min, mean arterial blood pressure 65 to 80 mm Hg, pulmonary artery wedge pressure 8 to 12 mm Hg, and cardiac index greater than 2.5 L · min-1 · m-2. The use of inotropic support was guided by the individual status of the patient. The fluid balance, the rectal temperature, and the peripheral temperature (measured on the back of the foot) were recorded every hour. The peripheral circulation was considered to be adequate if the difference between rectal temperature and peripheral skin temperature ({Delta}T) was less than 5° C.

Patients received mechanical ventilation to normocapnia and an arterial oxygen tension greater than 80 mm Hg with intermittent positive-pressure breathing and 5 cm H2O positive end-expiratory pressure. Detubation was permitted if the following criteria were met: (1) the patient was awake and cooperative with a spontaneous respiration frequency 10 to 20 breaths/min, (2) positive-pressure support was less than 5 cm H2O, (3) arterial oxygen tension was greater than 80 mm Hg, and (4) inspired oxygen fraction was less than 40%. The minimum required postoperative intubation time, that is, the moment that all four criteria were fulfilled, was recorded and was independent of the medical decision to detubate the patient at that time.

Basic intravenous fluid administration consisted of NaCl 0.9%. Modified fluid gelatin 4% (Netherlands Production Laboratory Blood Transfusion Requirements and Infusions, Emmer Compascuum, The Netherlands) and human albumin 20% (Central Laboratory Netherlands Red Cross Blood Transfusion Service, Amsterdam, The Netherlands) were added when the colloid oncotic pressure was less than 15 mm Hg. Packed red blood cells were infused when the hematocrit level was less than 26%. Blood loss and blood requirements were recorded until 18 hours after the operation.

Blood sampling and processing
All blood samples were drawn from the radial artery catheter or the arterial site of the extracorporeal circulation circuit distal from the arterial line filter and immediately immersed in crushed ice. After platelet-poor plasma was prepared, samples were stored at -70° C. Hematocrit value, leukocyte counts, and platelet counts were determined from all samples. Concentrations of TCC and PMN elastase were not corrected for dilution.

Terminal complement complex. Two milliliters of blood was collected in tubes and anticoagulated with ethylenedinitrotetra acetate before induction of anesthesia (baseline), after aortic crossclamp release, after termination of CPB, and 20 minutes after protamine infusion. Fluid phase C5b-9 complement complex concentrations were determined with use of an enzyme immunoassay according to protocol (Behringwerke AG Diagnostica, Marburg, Germany).

PMN elastase. Two milliliters of blood was collected in tubes and anticoagulated with citrate before induction of anesthesia (baseline), after aortic crossclamp release, after termination of CPB, and 1 hour after patient arrival in the ICU. PMN elastase concentrations were determined with use of an activating immunization method (Merck Diagnostica, Darmstadt, Germany) with an automated homogenous enzyme immunoassay (Hitachi 717 selective analyzer, Boehringer, Mannheim, Germany).

Data analysis
Data were stored and analyzed with the use of standard computer software (Statview 4.02, Abacus Concepts, Berkeley, Calif.). To quantitate the inflammatory response, a face validity–based score was applied.Go 14 This "clinical performance score" is composed of the sum of (1) the total fluid balance until 18 hours after operation (measured during the operation and every hour in the ICU), (2) the mean {Delta}DT during the first 18 hours in the ICU (measured every 2 hours), and (3) time of fulfillment of detubation criteria divided by 4. In this way, all the components of the score have a comparable range and therefore a comparable weight in the score. A higher score indicates a more pronounced inflammatory response.

Comparisons between groups were assessed with unpaired two-tailed t tests. Nonparametric statistical methods were used to analyze the skewed biochemical data (TCC and PMN elastase): comparisons within groups were assessed with the Wilcoxon signed-rank test and comparisons between groups with the Mann-Whitney U test. Spearman's rank correlation (rs) was calculated when appropriate. A two-tailed p value <0.05 was considered to be statistically significant. Means plus or minus the standard error of the mean are presented, unless otherwise stated.

RESULTS

Demographic data and surgical data of both groups are listed in GoTable I. No complications occurred and all patients survived and were discharged from the ICU on the first postoperative day. Both groups demonstrated a significant increase in circulating levels of TCC during and after CPB compared with baseline values (Fig. 1), but no further increments were observed after administration of protamine. Post-CPB peak levels of TCC were 38% lower in the heparin-coated group (775 µg/L, interquartile range 600 to 996) compared with those in the uncoated group (1249 µg/L, interquartile range 988 to 1443, p = 0.004). In both groups, concentrations of PMN elastase were significantly higher at the end of CPB compared with baseline values (Fig. 2). Concentrations of PMN elastase tended to be higher in the uncoated group, with the greatest difference occurring during the ICU stay (p = 0.07). A positive correlation was found between post-CPB peak levels of TCC and PMN elastase (Fig. 3, rs = 0.74, p = 0.0007).


View this table:
[in this window]
[in a new window]
 
Table I. Patient characteristics and surgical data
 


View larger version (19K):
[in this window]
[in a new window]
 
Fig. 1. Concentrations of fluid-phase TCC in patients treated with uncoated circuits (dotted line) or heparin-coated circuits (solid line). Data presented as medians with interquartile range. X-release, crossclamp release; *p < 0.05 between groups; xp < 0.005 compared with baseline values; +p < 0.05 compared with baseline values.

 


View larger version (20K):
[in this window]
[in a new window]
 
Fig. 2. Concentrations of PMN elastase in patients treated with uncoated circuits (dotted line) or heparin-coated circuits (solid line). Data presented as medians with interquartile range. There were no differences between groups at distinct sample moments. X-release, Crossclamp release; xp < 0.005 compared with baseline values; +p < 0.05 compared with baseline values.

 


View larger version (24K):
[in this window]
[in a new window]
 
Fig. 3. Scatter diagram of pooled data of post-CPB peak levels of fluid-phase TCC and post-CPB peak levels of PMN elastase.

 
The course of {Delta}T is presented in Fig. 4. During the first 4 hours in the ICU, {Delta}T was significantly higher in the uncoated group, and another 4 hours later {Delta}T was less than the desired 5° C in both groups. The clinical performance score and its components are depicted in GoTable II. A lower score (p = 0.03) was calculated for the heparin-coated group, whereas none of the components were different among groups. There were no differences between groups with respect to postoperative blood loss, blood requirements, hematocrit value, leukocyte count, or platelet count. Neither hemodynamic variables nor gas exchange values yielded intergroup differences. The hemodynamic response to CPB was not influenced by protamine infusion.



View larger version (16K):
[in this window]
[in a new window]
 
Fig. 4. Difference between rectal temperature and peripheral skin temperature ({Delta}DT) measured during first 18 hours after operation in patients treated with uncoated circuits (dottedline) or heparin-coated circuits (solid line). Data presented as means plus or minus standard error of mean. *p< 0.05 between groups.

 

View this table:
[in this window]
[in a new window]
 
Table II. Clinical performance score
 
DISCUSSION

This study clearly demonstrated that the use of heparin-coated circuits resulted in reduced concentrations of TCC during elective first-time CABG with normal heparinization. Moreover, the reduction of complement activation corresponded with improved postoperative recovery, as represented by a favorable clinical performance score in patients treated with heparin-coated circuits.

In all patients significant increments in circulating TCC were observed, but at all sample points during and after CPB concentrations of TCC were significantly lower in patients treated with heparin-coated circuits. Additional activation of the complement cascade by heparin-protamine complexes, as observed by others,Go Go 15,16 was not reflected in further increments of TCC levels after protamine infusion.

Because we have solely incorporated measurements of the terminal complex of complement activation, the mechanism by which the lower concentrations of TCC with heparin-coated circuits occurred remains to be elucidated. Both surface-bound and fluid-phase heparin exhibit inhibitory interference with multiple steps in the complement cascade.Go 17 The inactivation of C3b is intensified by heparin,Go 18 and Maillet and associatesGo 19 postulated that heparin prevents the generation of the C3 amplification convertase. Apart from the inhibitory capacity of heparin on activation of the alternative pathway, the lower TCC concentrations also might be explained by direct binding of TCC to the heparin coating, as proposed by Videm and associatesGo 20 on the basis of in vitro studies.

So far, complement studies that demonstrated a reduction of TCC with heparin-coated circuits were done in patients treated with reduced systemic heparinization in combination with heparin coating.Go Go Go 10,12,13 Because complement activation is inhibited by both surface-bound and fluid-phase heparin, no conclusions can be made concerning an inhibitory effect on complement activation of heparin coating and reduced systemic heparinization in comparison with routine heparinization and uncoated circuits. In the study presented here, an identical systemic heparinization protocol (3 mg/kg) for both heparin-coated and uncoated circuits was used, and clearly the inhibitory effect of heparin coating as the one discriminating variable on complement activation could be determined. This means that in a routine setting of CABG with full heparinization, a reduction of complement activation can be obtained when heparin-coated circuits are applied.

The diversity of inflammatory mediators identified in connection with CPB makes it difficult to determine their interaction or to define their role in the inflammatory response. Although an inhibitory effect of heparin-coated circuits on neutrophil activation could not be determined here, we demonstrated that 55% of the increase in PMN elastase could be explained by the increase in TCC. This is in agreement with previous findings that complement activation can up-regulate neutrophils.Go Go 21-23

Biocompatibility is defined as the ability of biomaterials to perform without a host response and usually is expressed by the levels of bioactive substances encountered in the circulation after contact with the biomaterial. However, the clinical response to improved biocompatibility is difficult to assess in patients undergoing elective CABG, because these responses are usually mild. Instead of isolated clinical parameters, we propose the use of a scoring system as a clinical end point. The score is composed of three parameters with equal weight, all more or less related with an inflammatory response to CPB. The fluid balance might reflect edema formation, whereas the difference between rectal temperature and skin temperature represents the peripheral circulation. The actual moment of detubation is merely a medical decision and is likely to flaw the score system. For that reason, we chose to record the moment at which standardized criteria for detubation are fulfilled. The lower score of patients treated with heparin-coated circuits indicates that, even after low-risk CABG, the postoperative inflammatory response was attenuated. The difference between rectal temperature and skin temperature was significantly higher in patients treated with uncoated circuits until 6 hours after operation. After that time, {Delta}T reached levels equal to those of the heparin-coating group. Early recovery of {Delta}T, as was observed in the heparin-coated group, might be particularly beneficial in patients with a compromised peripheral circulation.

In conclusion, we demonstrated that the biocompatibility of extracorporeal circulation circuits, as assessed by complement activation, can be improved by the immobilization of heparin on the inner surface of these circuits. A favorable clinical performance score was observed in patients treated with heparin-coated circuits. The potential usefulness and clinical relevance of heparin-coated circuits might be greatest when they are incorporated in protocols dealing with early recovery and reduction of intensive care requirements after cardiac operations, specifically in patients with high-risk factors.

Footnotes

From the Center for Cardiopulmonary Surgery Amsterdam,a the Departments of Anesthesiology,b Surgical Intensive Care,c and Biostatistics,d Free University Hospital, Amsterdam, and Department of Clinical Chemistry,e Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands. Back

References

  1. Butler J, Rocker GM, Westaby S. Inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 1993;55:552-9.[Abstract]
  2. Chenoweth DE, Cooper SW, Hugli TE, Steward RW, Blackstone EH, Kirklin JW. Complement activation during cardiopulmonary bypass: evidence for generation of C3a and C5a anaphylatoxins. N Engl J Med 1981;304:497-503.[Abstract]
  3. van Oeveren W, Kazatchkine MD, Deschamps-Latscha B, et al. Deleterious effect of cardiopulmonary bypass. J THORAC CARDIOVASC SURG 1985;89:888-99.[Abstract]
  4. Salama A, Hugo F, Heinrich D, et al. Deposition of terminal C5b-9 complement complexes on erythrocytes and leukocytes during cardiopulmonary bypass. N Engl J Med 1988;318:408-14.[Abstract]
  5. Kirklin JK, Westaby S, Blackstone EH, Kirklin JW, Chenoweth DE, Pacifico AD. Complement and the damaging effects of cardiopulmonary bypass. J THORAC CARDIOVASC SURG 1983;86:845-57.[Abstract]
  6. Moore FD, Warner KG, Assousa S, Valeri CR, Khuri SF. The effects of complement activation during cardiopulmonary bypass. Ann Surg 1988;208:95-103.[Medline]
  7. Deppisch R, Schmitt V, Bommer J, Hansch GM, Ritz E, Rautenberg EW. Fluid phase generation of terminal complement complex as a novel index of bioincompatibility. Kidney Int 1990;37:696-706.[Medline]
  8. Mollnes TE, Videm V, Riesenfeld J, et al. Complement activation and bioincompatibility: the terminal complement complex for evaluation, and surface modification with heparin for improvement of biomaterials. Clin Exp Immunol 1991;88(suppl 1):21-6.
  9. von Segesser LK, Wiess BM, Garcia E, Gallino A, Turina M. Reduced blood loss and transfusion requirements with low systemic heparinization: preliminary clinical results in coronary artery revascularization. Eur J Cardiothorac Surg 1990;4:639-43.[Abstract]
  10. Videm V, Svennevig JL, Fosse E, Semb G, Østerud A, Mollnes TE. Reduced complement activation with heparin-coated oxygenator and tubings in coronary bypass operations. J THORAC CARDIOVASC SURG 1992;103:806-13.[Abstract]
  11. Borowiec J, Thelin S, Bagge L, Nillson L, Venge P, Hansson HE. Heparin-coated circuits reduce activa-tion of granulocytes during cardiopulmonary bypass. J THORAC CARDIOVASC SURG 1992;104:642-7.[Abstract]
  12. Pekna M, Hagman L, Haldén E, Nilsson UR, Nilsson B, Thelin S. Complement activation during cardiopulmonary bypass: effects of immobilized heparin. Ann Thorac Surg 1994;58:421-4.[Abstract]
  13. Fosse E, Moen O, Johnson E, et al. Reduced complement and granulocyte activation with heparin-coated cardiopulmonary bypass. Ann Thorac Surg 1994;58:472-7.[Abstract]
  14. Feinstein AR. The evaluation of validity. In: Feinstein AR. Clinimetrics. 1st ed. New Haven and London: Yale University Press, 1987:141-66.
  15. Cavarocchi NC, Schaff HV, Orszulak TA, Homburger HA, Schnell WA, Pluth JR. Evidence for complement activation by protamine-heparin interaction after cardiopulmonary bypass. Surgery 1985;98:525-30.[Medline]
  16. Kirklin JK, Chenoweth DE, Naftel DC, et al. Effects of protamine administration after cardiopulmonary bypass on complement, blood elements, and the hemodynamic state. Ann Thorac Surg 1986;41:193-9.[Abstract]
  17. Kazatchkine MD, Fearon DT, Metcalfe DD, Rosenberg RD, Austen KF. Structural determinants of the capacity of heparin to inhibit the formation of the human amplification C3 convertase. J Clin Invest 1981;67:223-8.
  18. Boackle RJ, Caughman GB, Vesely J, Medgyeshi G, Fudenberg HH. Potentiation of factor H by heparin: a rate-limiting mechanism for inhibition of the alternative complement pathway. Mol Immunol 1983;20:1157-64.[Medline]
  19. Maillet F, Kazatchkine MD, Glotz D, Fischer E, Rowe M. Heparin prevents formation of the human C3 amplification convertase by inhibiting the binding site for B on C3b. Mol Immunol 1983;20:1401-4.[Medline]
  20. Videm V, Mollnes TE, Garred P, Svennevig JL. Biocompatibility of extracorporeal circulation: in vitro comparison of heparin-coated and uncoated oxygenator circuits. J THORAC CARDIOVASC SURG 1991;101:654-60.[Abstract]
  21. Chenoweth DE, Erickson BW, Hugli TE. Human C5a-related synthetic peptides as neutrophil chemotactic factors. Biochem Biophys Res Commun 1979;86:227-34.[Medline]
  22. Gu YJ, Van Oeveren W, Akkerman C, Boonstra PW, Huyzen RJ, Wildevuur ChRH. Heparin-coated circuits reduce the inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 1993;55:917-22.[Abstract]
  23. Butler J, Pillai R, Rocker GM, Westaby MS, Parker D, Shale DJ. Effect of cardiopulmonary bypass on systemic release of neutrophil elastase and tumor necrosis factor. J THORAC CARDIOVASC SURG 1993;105:25-30.[Abstract]



This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Banz, R. Rieben, C. Zobrist, P. Meier, S. Shaw, J. Lanz, T. Carrel, and P. Berdat
Addition of dextran sulfate to blood cardioplegia attenuates reperfusion injury in a porcine model of cardiopulmonary bypass
Eur. J. Cardiothorac. Surg., September 1, 2008; 34(3): 653 - 660.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
O. Mangoush, S. Purkayastha, S. Haj-Yahia, J. Kinross, M. Hayward, F. Bartolozzi, A. Darzi, and T. Athanasiou
Heparin-bonded circuits versus nonheparin-bonded circuits: an evaluation of their effect on clinical outcomes
Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1058 - 1069.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
C. W. Hogue Jr, C. A. Palin, and J. E. Arrowsmith
Cardiopulmonary bypass management and neurologic outcomes: an evidence-based appraisal of current practices.
Anesth. Analg., July 1, 2006; 103(1): 21 - 37.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
L. L. Creswell, J. C. Alexander Jr., T. B. Ferguson Jr., A. Lisbon, and L. A. Fleisher
Intraoperative Interventions: American College of Chest Physicians Guidelines for the Prevention and Management of Postoperative Atrial Fibrillation After Cardiac Surgery
Chest, August 1, 2005; 128(2_suppl): 28S - 35S.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Baufreton, P. Allain, A. Chevailler, F. Etcharry-Bouyx, J. J. Corbeau, D. Legall, and J. L. de Brux
Brain Injury and Neuropsychological Outcome After Coronary Artery Surgery Are Affected by Complement Activation
Ann. Thorac. Surg., May 1, 2005; 79(5): 1597 - 1605.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
R de Vroege, F te Meerman, L Eijsman, W R Wildevuur, C. R. Wildevuur, and W van Oeveren
Induction and detection of disturbed homeostasis in cardiopulmonary bypass
Perfusion, September 1, 2004; 19(5): 267 - 276.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
D. L. Ngaage
Off-pump coronary artery bypass grafting: the myth, the logic and the science
Eur. J. Cardiothorac. Surg., October 1, 2003; 24(4): 557 - 570.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
C. Baufreton, J. L. de Brux, P. Binuani, J.-J. Corbeau, J. B. Subayi, J. C. Daniel, and P. Treanor
A combined approach for improving cardiopulmonary bypass in coronary artery surgery: a pilot study
Perfusion, December 1, 2002; 17(6): 407 - 413.
[Abstract] [PDF]


Home page
CirculationHome page
P. Borgdorff, D. Fekkes, and G. J. Tangelder
Hypotension Caused by Extracorporeal Circulation: Serotonin From Pump-Activated Platelets Triggers Nitric Oxide Release
Circulation, November 12, 2002; 106(20): 2588 - 2593.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
P. J O'Gara, V. Natarajan, K. Lilly, A. Husain, O. M Shapira, and R. J Shemin
Clinical outcomes of on-pump coronary bypass using heparin-bonded circuits and reduced anti-coagulation compare favorably with off-pump approach
Perfusion, March 1, 2002; 17(2): 91 - 94.
[Abstract] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
H. A. Hennein
Inflammation After Cardiopulmonary Bypass: Therapy for the Postpump Syndrome
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2001; 5(3): 236 - 255.
[Abstract] [PDF]


Home page
PerfusionHome page
L.-C. Hsu
Heparin-coated cardiopulmonary bypass circuits: current status
Perfusion, September 1, 2001; 16(5): 417 - 428.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Suhara, Y. Sawa, M. Nishimura, H. Oshiyama, K. Yokoyama, N. Saito, and H. Matsuda
Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model
Ann. Thorac. Surg., May 1, 2001; 71(5): 1603 - 1608.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Koster, M. Loebe, R. Sodian, E. V. Potapov, R. Hansen, J. Muller, F. Mertzlufft, G. J. Crystal, H. Kuppe, and R. Hetzer
Heparin antibodies and thromboembolism in heparin-coated and noncoated ventricular assist devices
J. Thorac. Cardiovasc. Surg., February 1, 2001; 121(2): 0331 - 335.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
S. Svenmarker, E. Sandstrom, T. Karlsson, S. Haggmark, E. Jansson, M. Appelblad, R. Lindholm, and T. Aberg
Neurological and general outcome in low-risk coronary artery bypass patients using heparin coated circuits
Eur. J. Cardiothorac. Surg., January 1, 2001; 19(1): 47 - 53.
[Abstract] [Full Text] [PDF]


Home page
J Biomater ApplHome page
N. Weber, H. P. Wendel, and G. Ziemer
Quality Assessment of Heparin Coatings by their Binding Capacities of Coagulation and Complement Enzymes
J Biomater Appl, July 1, 2000; 15(1): 8 - 22.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. Belboul, C. Lofgren, C. Storm, and M. Jungbeck
Heparin-coated circuits reduce occult myocardial damage during CPB: a randomized, single blind clinical trial
Eur. J. Cardiothorac. Surg., May 1, 2000; 17(5): 580 - 586.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Richter, H. Meisner, P. Tassani, A. Barankay, W. Dietrich, and S. L. Braun
Drew-Anderson technique attenuates systemic inflammatory response syndrome and improves respiratory function after coronary artery bypass grafting
Ann. Thorac. Surg., January 1, 2000; 69(1): 77 - 83.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Borgdorff, R. H. van den Berg, M. A. Vis, G. C. van den Bos, and G. J. Tangelder
PUMP-INDUCED PLATELET AGGREGATION IN ALBUMIN-COATED EXTRACORPOREAL SYSTEMS
J. Thorac. Cardiovasc. Surg., November 1, 1999; 118(5): 946 - 952.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. L. Lazar, Y. Bao, J. Gaudiani, S. Rivers, and H. Marsh
Total Complement Inhibition : An Effective Strategy to Limit Ischemic Injury During Coronary Revascularization on Cardiopulmonary Bypass
Circulation, September 28, 1999; 100(13): 1438 - 1442.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. P. Wendel and G. Ziemer
Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation
Eur. J. Cardiothorac. Surg., September 1, 1999; 16(3): 342 - 350.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
C. B. Mahoney and G. M. Lemole
Transfusion after coronary artery bypass surgery: the impact of heparin-bonded circuits
Eur. J. Cardiothorac. Surg., August 1, 1999; 16(2): 206 - 210.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. M. McCarthy, J.-P. P. Yared, R. C. Foster, D. A. Ogella, J. A. Borsh, and D. M. Cosgrove III
A prospective randomized trial of Duraflo II heparin-coated circuits in cardiac reoperations
Ann. Thorac. Surg., May 1, 1999; 67(5): 1268 - 1273.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Baufreton, L. Intrator, P. G.M. Jansen, H. te Velthuis, P. Le Besnerais, A. Vonk, J.-P. Farcet, C. R.H. Wildevuur, and D. Y. Loisance
Inflammatory response to cardiopulmonary bypass using roller or centrifugal pumps
Ann. Thorac. Surg., April 1, 1999; 67(4): 972 - 977.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
C. Baufreton, M. Moczar, L. Intrator, P. G. Jansen, H. te Velthuis, P. Le Besnerais, J. P. Farcet, C. R. Wildevuur, and D. Y Loisance
Inflammatory response to cardiopulmonary bypass using two different types of heparin-coated extracorporeal circuits
Perfusion, December 1, 1998; 13(6): 419 - 427.
[Abstract] [PDF]


Home page
PerfusionHome page
C B. Mahoney
Heparin-bonded circuits: clinical outcomes and costs
Perfusion, May 1, 1998; 13(3): 192 - 204.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, T. Hamasaki, Y. Bao, S. Rivers, S. A. Bernard, and R. J. Shemin
Soluble Complement Receptor Type I Limits Damage During Revascularization of Ischemic Myocardium
Ann. Thorac. Surg., April 1, 1998; 65(4): 973 - 977.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Ashraf, J. Butler, Y. Tian, D. Cowan, S. Lintin, N. R. Saunders, K. G. Watterson, and P. G. Martin
Inflammatory Mediators in Adults Undergoing Cardiopulmonary Bypass: Comparison of Centrifugal and Roller Pumps
Ann. Thorac. Surg., February 1, 1998; 65(2): 480 - 484.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. E. Helm, T. K. Rosengart, M. Gomez, J. D. Klemperer, W. J. DeBois CPP, F. Velasco, J. P. Gold, N. K. Altorki, S. Lang, S. Thomas, et al.
Comprehensive Multimodality Blood Conservation: 100 Consecutive CABG Operations Without Transfusion
Ann. Thorac. Surg., January 1, 1998; 65(1): 125 - 136.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Ashraf, Y. Tian, D. Cowan, A. Entress, P. G. Martin, and K. G. Watterson
Release of Proinflammatory Cytokines During Pediatric Cardiopulmonary Bypass: Heparin-Bonded Versus Nonbonded Oxygenators
Ann. Thorac. Surg., December 1, 1997; 64(6): 1790 - 1794.
[Abstract] [Full Text]


Home page
CirculationHome page
P. Bruins, H. t. Velthuis, A. P. Yazdanbakhsh, P. G. M. Jansen, F. W. J. van Hardevelt, E. M. F. H. de Beaumont, C. R. H. Wildevuur, L. Eijsman, A. Trouwborst, and C. E. Hack
Activation of the Complement System During and After Cardiopulmonary Bypass Surgery : Postsurgery Activation Involves C-Reactive Protein and Is Associated With Postoperative Arrhythmia
Circulation, November 18, 1997; 96(10): 3542 - 3548.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. t. Velthuis, C. Baufreton, P. G. M. Jansen, C. M. Thijs, C. E. Hack, A. Sturk, C. R. H. Wildevuur, and D. Y. Loisance
HEPARIN COATING OF EXTRACORPOREAL CIRCUITS INHIBITS CONTACT ACTIVATION DURING CARDIAC OPERATIONS
J. Thorac. Cardiovasc. Surg., July 1, 1997; 114(1): 117 - 122.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, X. Zhang, T. Hamasaki, C. A. Memmelo, P. Treanor, S. Rivers, G. S. Aldea, S. A. Bernard, and R. J. Shemin
Heparin-Bonded Circuits Decrease Myocardial Ischemic Damage: An Experimental Study
Ann. Thorac. Surg., June 1, 1997; 63(6): 1701 - 1705.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
S. Wan, J.-L. LeClerc, and J.-L. Vincent
Cytokine Responses to Cardiopulmonary Bypass: Lessons Learned From Cardiac Transplantation
Ann. Thorac. Surg., January 1, 1997; 63(1): 269 - 276.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, E. A. Holen, G. Tangen, and M.-A. L. Ringdal
Heparinized Cardiopulmonary Bypass and Full Heparin Dose Marginally Improve Clinical Performance
Ann. Thorac. Surg., October 1, 1996; 62(4): 1128 - 1133.
[Abstract] [Full Text]


Home page
PerfusionHome page
M. Yii, T. Gourlay, J. Fleming, B. Matata, and K. Taylor
Evaluation of Carmeda(R) Bioactive Surface (CBAS(R)), Duraflo II and a novel nonspecific protease-modified surface using a new in vitro model simulating cardiopulmonary bypass
Perfusion, May 1, 1996; 11(3): 229 - 240.
[PDF]