JTCS St. Jude Medical
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Keishu Yasuda
Norihiko Shiiya
Toshifumi Murashita
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suto, Y.
Right arrow Articles by Sakuma, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suto, Y.
Right arrow Articles by Sakuma, M.

J Thorac Cardiovasc Surg 1996;112:1389-1390
© 1996 Mosby, Inc.


BRIEF COMMUNICATIONS

STENTED ELEPHANT TRUNK PROCEDURE FOR AN EXTENSIVE ANEURYSM INVOLVING DISTAL AORTIC ARCH AND DESCENDING AORTA

Yukio Suto, MD, Keishu Yasuda, MD, Norihiko Shiiya, MD, Toshifumi Murashita, MD, Masakazu Kawasaki, MD, Michiaki Imamura, MD, Kou Takigami, MD, Shigeyuki Sasaki, MD, Yoshiro Matsui, MD, Makoto Sakuma, MD


Sapporo, Japan

From the Department of Cardiovascular Surgery, Hokkaido University, Sapporo, Japan.

Received for publication March 26, 1996 Accepted for publication May 6, 1996. Address for reprints: Yukio Suto, MD, Department of Cardiovascular Surgery, Hokkaido University School of Medicine, Kita-14, Nishi-5, Kita-ku, Sapporo, Japan 060.

Replacement of extensive portions of the aorta remains a formidable task, especially in patients with poor risk conditions and those with pulmonary disease. In this article, we present a successful single-stage replacement of the arch and descending aorta through sternotomy with the "stented" elephant trunk procedure in a patient at high risk.

A 71-year-old woman, who had undergone prosthetic graft replacement because of a thoracoabdominal aortic aneurysm 6 years previously, was admitted to the hospital because of an extensive aneurysm involving distal aortic arch and descending aorta. Computed tomography showed that the aneurysm was enlarged to 72 mm in diameter and was extended to 3 cm above the proximal anastomosis of the previous prosthetic graft. Because severe pleural adhesion caused by old tuberculosis was found at previous operation, we decided to operate through a median sternotomy without entering the left pleural space. For this purpose, the elephant trunk techniqueGo 1 was used and the distal end of the trunk was fixed with a stent under endoscopic guidance.

Operative procedure

The ascending aorta and the aortic arch were exposed through a median sternotomy. Cardiopulmonary bypass was established by ascending aortic and bicaval cannulations. The patient was cooled to a rectal temperature of 20º C. Cardiac arrest was obtained with ascending aortic crossclamping and antegrade and retrograde cold blood cardioplegic solution. Under selective cerebral perfusion and systemic circulatory arrest, the aortic arch was transected just proximal to the aneurysm at the level of the origin of the left subclavian artery. A Gianturco stent (Cook, Bloomington, Ind.), 40 mm in diameter and 50 mm in length, was inserted and fixed to a 30 mm collagen-coated woven Dacron graft, and an endoscope was inserted through it. This combined graft was constricted by three purse-string sutures. Under endoscopic guidance, the combined graft was inserted into the aneurysm as an elephant trunk prosthesis. The distal end of the graft was located 3 cm above the proximal anastomotic site of the previous graft to preserve the intercostal flow, which was identified with the endoscope at 2 cm above the proximal anastomosis. Dense mural thrombus was present in the aneurysm, and no other patent intercostal and bronchial artery was identified. The length of the trunk was about 10 cm. The stent was then expanded by releasing the purse strings to fix the distal end of the trunk.

The proximal portion of the graft was anastomosed to the aortic stump (Fig. 1, A), and the invaginated portion of the graft was pulled out. Subsequently, total arch replacement was done with 24 mm gelatin-coated knitted Dacron fabric with four branches. First the branched graft was connected to the elephant trunk, and systemic reperfusion and rewarming were started through the fourth branch. Then the branched graft was anastomosed to the native ascending aorta, and the ascending aorta was unclamped for coronary reperfusion. Finally three arch vessels were sutured end to end to the branch grafts (Fig. 1, B). The patient was weaned from bypass without problems. The postoperative course was uneventful. Angiography undertaken 4 weeks after operation indicated adequate expansion of the stent and no blood flow around the graft (Fig. 2).




View larger version (40K):
[in this window]
[in a new window]
 
Fig. 1. Schematic drawing of operation. See text for details.

 



View larger version (264K):
[in this window]
[in a new window]
 
Fig. 2. Angiograms before (left) and after (right) operation. Arrowheads indicate the location of the stent.

 
Discussion

Since Borst, Walterbusch, and SchapsGo 1 introduced the elephant trunk technique in 1983 this technique has been widely used for staged aortic replacement.Go Go 2-4 In addition, these investigators reported one case in which the dead space around the long elephant trunk was filled with clot and further operation was not needed.Go 2 The authors highlighted this phenomenon as a further potential use of this technique. Crawford and associatesGo 3 reported complications of this method: kinking and occlusion of the graft, paraplegia as a result of clot around the graft, and peripheral thromboembolism caused by flapping action. They stated that these complications were more likely when the trunk was longer.

To avoid these potential complications of a long elephant trunk graft, we used a stent at the distal end to fix the graft to the native aortic wall. By this method, we could prevent any kinking and flapping action of the graft. In addition, we can expect complete obliteration of the dead space around the graft even if there are patent intercostal arteries, because the hemodynamic conditions around the graft are similar to those after thromboexclusion. Although there may be a limitation on indications for our method, it is a useful alternative for patients at poor risk and those with pulmonary disease.

References

  1. Borst HG, Walterbusch G, Schaps D. Extensive aortic replacement using "elephant trunk" prosthesis. Thorac Cardiovasc Surg 1983;31:37-40.[Medline]
  2. Borst HG, Frank G, Schapes D. Treatment of extensive aortic aneurysm by a new multiple-stage approach. J Thorac Cardiovasc Surg 1988;95:11-3.[Abstract]
  3. Crawford ES, Coselli JS, Svensson LG, Safi HJ, Hess KR. Diffuse aneurysmal disease (chronic aortic dissection, Marfan, and mega aorta syndromes) and multiple aneurysm: treatment by subtotal and total aortic replacement emphasizing the elephant trunk operation. Ann Surg 1990;211:521-37.[Medline]
  4. Heinemann MK, Buehner B, Jurmann MJ, Borst HG. Use of the "elephant trunk technique" in aortic surgery. Ann Thorac Surg 1995;60:2-7.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
M. Karck and H. Kamiya
Progress of the treatment for extended aortic aneurysms; is the frozen elephant trunk technique the next standard in the treatment of complex aortic disease including the arch?
Eur. J. Cardiothorac. Surg., June 1, 2008; 33(6): 1007 - 1013.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. Flores, T. Kunihara, N. Shiiya, K. Yoshimoto, K. Matsuzaki, and K. Yasuda
Extensive deployment of the stented elephant trunk is associated with an increased risk of spinal cord injury
J. Thorac. Cardiovasc. Surg., February 1, 2006; 131(2): 336 - 342.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M. Karck, A. Chavan, N. Khaladj, H. Friedrich, C. Hagl, and A. Haverich
The frozen elephant trunk technique for the treatment of extensive thoracic aortic aneurysms: operative results and follow-up
Eur. J. Cardiothorac. Surg., August 1, 2005; 28(2): 286 - 290.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Kuki, K. Taniguchi, T. Masai, T. Yokota, K. Yoshida, K. Yamamoto, and H. Matsuda
An Alternative Approach Using Long Elephant Trunk for Extensive Aortic Aneurysm: Elephant Trunk Anastomosis at the Base of the Innominate Artery
Circulation, September 24, 2002; 106(12_suppl_1): I-253 - I-258.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Miyamoto, T. Hadama, H. Anai, H. Sako, and O. Shigemitsu
Stented elephant trunk method for multiple thoracic aneurysms
Ann. Thorac. Surg., February 1, 2001; 71(2): 705 - 707.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Keishu Yasuda
Norihiko Shiiya
Toshifumi Murashita
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suto, Y.
Right arrow Articles by Sakuma, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suto, Y.
Right arrow Articles by Sakuma, M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS