JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Lester R. Sauvage
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kouchi, Y.
Right arrow Articles by Sauvage, L. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kouchi, Y.
Right arrow Articles by Sauvage, L. R.

J Thorac Cardiovasc Surg 1997;113:114-120
© 1997 Mosby, Inc.


SURGERY FOR ACQUIRED HEART DISEASE

EFFECT OF ALTERED BLOOD FLOW ON THE CALIBER AND MORPHOLOGY OF THE INTERNAL THORACIC ARTERY IN THE DOG

Yasuhiro Kouchi, MD, Yoko Onuki, MD, Moses Hong-De Wu, MD, Qun Shi, MD, Lester R. Sauvage, MD, From The Hope Heart Institute, the Providence Medical Center, and the Department of Surgery, University of Washington School of Medicine, Seattle, Wash.

Received for publication Dec. 26, 1995 Revisions requested Feb. 6, 1996 Revisions received June 28, 1996 Accepted for publication July 8, 1996 Address for reprints: Lester R. Sauvage, MD, The Hope Heart Institute, 528 18th Ave., Seattle, WA 98122.

Abstract

Objective: The purpose of this study was to evaluate in dogs the effect of blood flow alteration on caliber and morphology of in situ internal thoracic arteries. Methods: Six dogs underwent creation of a unilateral distal arteriovenous fistula between the internal thoracic artery and vein at the sixth rib to create high flow, and in six others the internal thoracic artery was unilaterally skeletonized and dissected. For both groups the contralateral internal thoracic artery served as the control; sides were alternated among cases. Blood flow was measured for shear stress calculation before and after surgical alteration. After 2 months, internal thoracic arteries were harvested with the entire anterior chest plate, which was dynamically inflated and fixed with 10% formalin at a controlled pressure of 120 mm Hg after angiography had been done at the same pressure. The luminal diameters were then measured at eight levels on the angiograms. Arterial tissue samples were taken at three levels and embedded, sectioned, and treated with hematoxylin-eosin and Verhoeff-van Gieson stains. Digital imaging analysis was used for quantitative morphometric studies. Results: All fistulas remained patent. In comparison with control arteries, high-flow internal thoracic arteries dilated and low-flow internal thoracic arteries narrowed, which was associated with significant change in shear stress for both groups. There were no substantial structural changes in the walls of either group. Conclusion: In the dog, the luminal diameter of the internal thoracic artery responds to altered blood flow without intimal thickening or other undesirable wall changes.

Use of the internal thoracic artery (ITA) as a coronary artery bypass graft is becoming more common because of its superior long-term patency.Go Go 1-5 However, a diffuse narrowing of the distal portion of a few ITA grafts, described as a "string sign" or "distal thread phenomenon," has been noted.Go Go 6-10 The cause of this phenomenon has been attributed to a low-flow rheologic state in the ITA graft that results from anastomosing it to a coronary artery with only a minor degree of proximal stenosis. BarnerGo 6 introduced the concept of "disuse atrophy" as a mechanism for this narrowing. The disappearance of a low-flow-initiated "string sign" was observed when high flow through the ITA was restored.Go Go 8,10 This reversible phenomenon may suggest that decreasing flow could cause the ITA to contract in a rheologically directed effort toward maintenance of a suitable shear stress on the arterial wall. It has also been reported that high flow through the ITA causes its caliber to increase.Go Go 11,12 Although these clinical findings suggest that changes in the caliber of the ITA correlate with graft flow, there have been no experimental studies to characterize this correlation. The purpose of this study was to evaluate the effect of altering the blood flow on the caliber and morphology of the in situ ITA in dogs during a 2-month period of observation.

Material and Methods

Twelve healthy mongrel dogs, weighing 21.0 to 29.0 kg (average weight 24.3 kg, SDGo * 0.6 kg), were used in this study. All animals were cared for in compliance with the "Guide for the Care and Use of Laboratory Animals" prepared by the National Institutes of Health (NIH Publication No. 80-23, revised 1985).

The animals were divided into two groups: a high-flow (HF) group, in which a unilateral distal arteriovenous fistula (AVF) was created between the ITA and vein at the sixth rib site, and a low-flow (LF) group, in which the ITA was unilaterally skeletonized and dissected with bipolar cauterization, as previously described.Go 13 Both groups were studied in a paired comparison form, in which one ITA was altered as described and the contralateral ITA was left untouched to serve as the control; sides were alternated among cases.

Surgical procedures
After premedication of the dogs with acepromazine, 0.25 mg/kg, and atropine, 0.01 mg/kg, anesthesia was induced with 5 to 10 ml of 4% thiamylal intravenously and the animals were intubated. The anesthesia was then maintained with a combination of 0.5% to 1% halothane and a mixture of nitrous oxide and oxygen in a 2:1 ratio via an endotracheal tube connected with a closed-circuit respirator.

HF group (n = 6)
With the dog in the supine position, the operative field was disinfected and draped. A parasternal incision approximately 7 cm long was made, and the ITA and vein were approached after removal of a short segment of the sixth rib cartilage. A side-to-side AVF, approximately 5 mm long, was created between the ITA and vein at the sixth rib level with the use of running 8-0 Prolene polypropylene sutures (Ethicon, Inc., Somerville, N.J.).

LF group (n = 6)
The dog was placed in the lateral decubitus position. Under one skin incision two thoracotomies were made through the fourth and seventh intercostal spaces. The entire length of the ITA was skeletonized and dissected down to its bifurcation into the superior epigastric and musculophrenic branches with bipolar cauterization (Davol Electro Medical System, Englewood, Colo.). During the dissection, the branches were carefully cauterized three times, one second per time, by gently squeezing the bipolar cautery forceps along a 2 mm wide zone beginning 2 mm distal to the origin of the branches. The branch was then cut with scissors in the middle of the cauterized zone.Go 13

ITA blood flow in both groups was measured both before and after the surgical alteration with a Transonic flowmeter, which directly measures the flow rate, rather than the flow velocity (model T-208, Transonic Systems, Inc., Ithaca, N.Y.), with a 3 mm probe on the ITA. Blood flow was measured just proximal to the AVF at the sixth rib level of the ITA in the HF group and at the proximal portion of the ITA in the LF group. Wounds were closed when the fields were completely dry. Appropriate antibiotics were given on the day of operation and for the next 10 days thereafter.

Specimen retrieval and angiographic evaluation
All specimens were retrieved 8 weeks after operation. The animals were pretreated with acepromazine and deeply anesthetized with thiamylal sodium. Both ITAs were accessed proximally via the supraclavicular approach. Blood flow rates were then simultaneously measured with a two-channel Transonic model T-208 flowmeter with 3 mm probes at the same level of the proximal ends of both ITAs. After administration of a 3 mg/kg dose of heparin the entire anterior chest plate, about 30 cm long x 25 cm wide and including both ITAs, was harvested as an intact single specimen. In the HF group, the internal thoracic vein was ligated 15 mm away from the AVFs, both proximally and distally.

Bilateral ITA angiography with a posteroanterior projection of the harvested chest plate was then done. ITAs were opacified by injection of 15 ml of Conray 60% iothalamate meglumine solution (Mallinckrodt Medical, Inc., St. Louis, Mo.) with 120 mm Hg pressure through two small, connected angiocatheters, which were placed in the proximal ITAs. The luminal diameters at eight levels of the ITAs, from the first to eighth rib sites, were measured with a digital caliper (model CD-6BS, Mitutoyo Corp., Utsunomiya, Japan). Each diameter reported in the results section was the actual luminal diameter after correction of magnification with the original length scale projected on the angiogram.

Morphologic evaluation of the arterial wall
The ITAs, with the whole chest plate, were dynamically inflated and fixed via the two angiocatheters used for angiography: 10% formalin was maintained at 120 mm Hg with a perfusion system for 24 hours, and the specimen was kept in formalin for an additional 2 days. Cross-section tissue samples from both the control and study ITAs were taken for light microscopy from the proximal (at the second rib), middle (at the fifth rib), and distal (at the eighth rib) sites. The tissue samples were embedded, sectioned, and treated with hematoxylin-eosin and Verhoeff-van Gieson stains. Digital imaging was used for quantitative morphometric studies. The image was transferred from histologic slides to microscopic photoprints, from which the image was scanned with a Relisys image scanner (Avec model 2400, Milpitas, Calif.). The magnification factor was eliminated by a standard micrometer scale during this processing. The cross-sectional areas (in square millimeters) of the arterial lumen, the intima, the media, and the adventitia were measured and the luminal radius, intimal thickness, medial thickness, and whole wall thickness (in millimeters) were calculated with an image analysis system (Macintosh computer with National Institutes of Health image 1.55). The morphometric data were used for subsequent data analysis.

Shear stress
To further analyze the relationship between the rheologic measurements and morphologic observations, shear stress was calculated. Shear stress was considered to be the force causing the morphologic change. Mean shear stress was calculated from the flow rate measured during specimen retrieval, and the luminal diameter at the site corresponding to the flow measurement was measured from the angiogram by the Hagen-Poiseuille formula


where {tau} is shear stress (in dynes per square centimeter), µ is viscosity (assumed to be 035 poise), Q is blood flow rate (in milliliters per second), and r is luminal radius (in centimeters).

Statistical analysis
The quantitative morphometric data were expressed as the arithmetic mean plus or minus the standard deviation. Statistical analysis was done with the Student's t test for paired samples obtained from the control and study specimens. Statistical significance was defined as p < 0.05.

Results

Measurement of blood flow rate
All AVFs remained patent. During operation the blood flow rate increased an average of 9.9 times (95% confidence interval [CI], 6.7 to 13.1) through the ITA (measured at the sixth rib level) after the creation of the AVF (from an average of 19.7 ml/min [SD 9.9] to 183 ml/min [SD 101], p = 0.03). During specimen retrieval, the HF group showed an average flow rate in the operated ITA 6.2 times higher than that in the contralateral control ITAs (95% CI, 2.4 to 10.0), measured at the proximal site of the ITA (306 ml/min [SD 251] versus 62.8 ml/min [SD 42.0], p = 0.04) (Table I).


View this table:
[in this window]
[in a new window]
 
Table I. Hemodynamic alterations and measurement
 
During operation, the skeletonized, dissected ITAs exhibited an average 73.5% flow reduction (95% CI, 66.7 to 79.9), measured at the proximal portion of the ITA (from 51.7 ml/min [SD 32.1] to 13.3 ml/min [SD 10.3], p = 0.0003). At the end of the study, the LF group had an average flow rate 69.0% less than that in the contralateral control ITAs (95% CI, 61.0 to 77.0), measured at the proximal end of the ITA (10.7 ml/min [SD 2.3] versus 35.3 ml/min [SD 5.4], p = 0.0001) (Table I).

Angiographic findings
Angiograms revealed a dilation of the HF group ITAs with the AVF in comparison with the control ITAs (Fig. 1, A). The average luminal diameter measurements given in Fig. 1, B, demonstrate a statistically significant difference along the length proximal to the AVF, but not beyond the AVF. On the other hand, angiograms revealed a shrinkage (or narrowing) of the LF group ITAs with skeletonized dissection in comparison with the control ITAs (Fig. 1, C) and a significant difference in the average measured diameter along the entire length, except at the first rib level (Fig. 1, D).




View larger version (134K):
[in this window]
[in a new window]
 
Fig. 1. Angiograms comparing representative high- and low-flow ITAs with their control arteries and diagrams of average luminal diameters showing significant differences according to rib levels between vessels with altered flow and control arteries. A, High-flow ITA is on left, with control artery on right. Distal ITA beyond AVF is overshadowed by accompanying internal thoracic vein, which was filled with dye from collateral circulation. B, Difference between average luminal diameters of high-flow ITA and control artery is significant from first to fifth rib levels (distal to AVF, what appears to be artery is vein.) C, Low-flow ITA is on right, with control artery on left. D, Difference between average luminal diameters of low-flow ITA and control artery is significant from second to eighth rib levels.

 
Histologic morphologic studies
Histologically, except for the morphologic dimension, there was no substantial structural change in the wall, including no intimal thickening, in either the HF or LF groups after flow alteration.

For the HF group ITAs, the luminal area was significantly increased by an average of 14.0% (95% CI, 6.2 to 21.8) at the proximal level and by an average of 22.6% (95% CI, 8.0 to 37.2) at the middle level in comparison with the area in the control arteries (Fig. 2, A and B, and Table II). A similar significant difference was also found with the luminal radius (Table II). However, there was no significant difference at the distal level of the ITA (distal to the AVF). There was also no significant difference between the HF group and control ITAs at any level for the cross-sectional area of the media and the thicknesses of the intima, the media, and the whole wall (Table II).






View larger version (501K):
[in this window]
[in a new window]
 
Fig. 2. Comparison of representative cross-sectional areas at middle of ITA. A, High-flow ITA; B, paired control at same level; C, low-flow ITA; D, paired control at same level. There is no evidence of intimal thickening in either case. (Hematoxylin-eosin stain; original magnification x24.)

 

View this table:
[in this window]
[in a new window]
 
Table II. Morphologic dimensional measurements from histologic sections taken from the middle of the ITAs
 
For the LF group ITAs, the luminal area was significantly decreased by an average of 11.4% (95% CI, 6.4 to 16.4) at the proximal, 16.9% (95% CI, 10.9 to 22.9) at the middle, and 22.6% (95% CI, 13.8 to 31.4) at the distal portion, in comparison with the areas in the control arteries (Fig. 2, C and D, and Table II). The luminal radius was also significantly smaller at all levels. At the middle level, the cross-sectional area of the media, the thicknesses of the media, and the thicknesses of the whole wall of the LF group ITAs were significantly greater than those of the control arteries (Table II). There was no significant difference in intimal thickness (Table II).

Shear stress
Eight weeks after creation of the distal AVF, the calculated mean shear stress in the high-flow ITAs averaged 58.8 dynes/cm2 (SD 16.2), which was significantly different from the average shear stress of 19.6 dynes/cm2 (SD 6.3) for the control arteries (p = 0.035) (Table I). The shear stress in the skeletonized, dissected ITAs averaged 3.7 dynes/cm2 (SD 0.4), which was also significantly different from the average shear stress of 10.3 dynes/cm2 (SD 0.7) for the control arteries (p < 0.0001) (Table I).

Discussion

Clowes and KohlerGo 14 have pointed out that both developing and mature vessels respond to changes in blood flow by adjusting their diameters in a manner that maintains constant shear stress, and there is considerable evidence of this.Go Go 15-20 Kamiya and TogawaGo 15 demonstrated that increased wall shear stress induced adaptive enlargement of the arterial radius in a model with AVF in the canine carotid artery, which acted as a negative feedback to reduce shear stress. Guyton and HartleyGo 16 and Langille and O'DonnellGo 17 demonstrated that reduction in arterial diameter could be induced by decreased blood flow in the carotid arteries of rats and rabbits. Similar observations obtained from this study of canine ITAs support their findings.

Zarins and associatesGo 18 have demonstrated with 6-month experiments in the iliac artery of cynomolgus monkeys that shear stress is normalized, or optimal shear stress is achieved, by enlargement of the artery in the case of increased flow and have suggested that intimal thickening achieves the same result in the event of reduced flow. However, in this study in the dog with 8-week flow alteration, although there was a tendency to shear stress normalization in both the HF and LF group ITAs, it did not reach the level in the control ITAs. There was also no substantial wall structural change, including no intimal thickening, in either the HF or the LF group, except for an increase in media thickness and cross-sectional area in the middle of the LF group ITAs (Table II). The differences between the study of Zarins and associatesGo 18 and this study may be associated with the implant times and the nature of the vessels studied. The 6-month study of Zarins and associatesGo 18 was much longer than ours, and the shear stress in our ITAs with altered flow might eventually have come close to, or reached, the normal control level with a further luminal diameter change if the study period had been longer than 8 weeks. Although medium-sized and small arteries have been classified as muscular, van Son and coworkersGo 21 have proposed that most of the ITA is an elastic artery with elastomuscular proximal and distal sections; this type of artery may have a different nature than the iliac artery in the monkey.

Langille, Bendeck, and KeeleyGo 22 and Masuda and associatesGo 19 pointed out that arterial wall remodeling was endothelium dependent and reflected a direct sensitivity of endothelial cells to the frictional force exerted on them by blood flow. Frangos and colleaguesGo 23 hypothesized that endothelial cells are somehow capable of sensing changes in shear stress and can translate this biomechanical information into biochemical signals that then regulate the contractile state of the underlying smooth muscle cells. Therefore there may be thresholds of flow shear stress to which specific vessels respond. In this regard, the ITA may have a lesser sensitivity or broader nonresponsive tolerance than other vessels, such as carotid and iliac arteries used in similar studies. This is also supported by studies that reported no intimal thickening of the ITAs.Go Go 21,24 This presumed broader tolerance of the ITA wall to changes in shear stress may partially explain why the ITAs maintain better patency than other autogenous grafts when used for coronary bypass.Go Go Go Go 1,21,25,26 In our study, the ITA wall did seem to be relatively more sensitive to low flow than high, with an increase in the thickness of the media in the middle portion of the LF group ITAs, but not in the HF group ITAs.

Some studies have suggested that the ITA graft diameter, when used as a coronary artery bypass, is determined by the volume of blood going through it.Go Go 10,12 Björk and associatesGo 11 reported that preoperative overestimation of coronary artery stenosis and postoperative regression of coronary artery lesions were major factors in the reduction of ITA graft diameter. In that situation, the inflow from the proximal coronary artery is high, and the flow through the ITA graft will be low. This competitive rheologic combination may lead to narrowing of the ITA with development of the angiographic "string sign" finding.Go Go 6-8 Singh and SosaGo 27 reported that an undivided major ITA side branch could cause blood steal phenomenon and result in reduction of the distal ITA lumen. Stenoses at the anastomotic site have also been reported as possible causes of postoperative narrowing of ITA grafts.Go 11 Our experimental results support the clinical observations that factors that diminish the ITA flow will decrease the ITA diameter. Conversely, flow through an ITA graft leads to enlargement of its caliber. The large size of the in situ ITAs in coarctation of the aortaGo Go 28,29 is a manifestation of the same phenomenon. Again, our experimental finding is in keeping with this clinical observation (Figs. 1 and 2 and Table II).

In summary, this study demonstrated that the luminal diameter of the ITA adaptively enlarged after blood flow increase and diminished after blood flow decrease, with a tendency to normalize wall shear stress. No substantive wall structural change, including intimal thickening, was associated with either increased or decreased luminal blood flow in our 2-month observation period.

Acknowledgments

We thank Mary Ann Sedgwick Harvey, medical editor, Mary-Ann Nelson, medical illustrator, David Criss, medical photographer, and Mark Walker, surgery supervisor, for their important contributions to these investigations.

Footnotes

*Standard deviation. Back

References

  1. Flemma RJ, Singh HM, Tector AJ, Lepley DJ, Frazier BL. Comparative hemodynamic properties of vein and mammary artery in coronary bypass operations. Ann Thorac Surg 1975;20:619-27.[Abstract]
  2. Myojin K, Weiss G, Mee R, et al. Functional comparison of coronary bypass grafts of the saphenous vein and internal mammary artery. 1980;79:713-17.
  3. Björk VO, Ekestrom S, Henze A, Ivert T, Landou C. Indications for the internal mammary artery graft. Scand 1981;15:1-9.
  4. Loop F, Lytle B, Cosgrove D, et al. Influence of the internal-mammary-artery graft on 10-year survival and other cardiac events. N Engl J Med 1986;314:1-6.[Abstract]
  5. Spencer F. The internal mammary artery: the ideal coronary bypass graft? [Editorial]. N Engl J Med 1986;314:50-1.[Medline]
  6. Barner HB. Double internal mammary–coronary artery bypass. Arch Surg 1974;109:627-30.[Abstract/Free Full Text]
  7. Geha AS, Baue AE. Early and late results of coronary revascularization with saphenous vein and internal mammary artery grafts. Am J Surg 1979;137:456-63.[Medline]
  8. Dincer B, Barner HB. The "occluded" internal mammary artery graft: restoration of patency after apparent occlusion associated with progression of coronary disease. 1983;85:318-20.
  9. Suma H. Internal thoracic artery and competitive flow [Letter, comment]. 1991;102:639-40.
  10. Seki T, Kitamura S, Kawachi K, et al. A quantitative study of postoperative luminal narrowing of the internal thoracic artery graft in coronary artery bypass surgery. 1992;104:1532-8.
  11. Björk VO, Ivert T, Landou C. Angiographic changes in internal mammary artery and saphenous vein grafts, two weeks, one year and five years after coronary bypass surgery. Scand 1981;15:23-30.
  12. Ivert T, Huttunen K, Landou C, Björk V. Angiographic studies of internal mammary artery grafts 11 years after coronary artery bypass grafting. 1988;96:1-12.
  13. Yoshida H, Wu MH-D, Kouchi Y, Onuki Y, Shi Q, Sauvage LR. Comparison of the effect of monopolar and bipolar cauterization on skeletonized, dissected internal thoracic arteries. 1995;110:504-10.
  14. Clowes AW, Kohler TR. Anatomy, physiology and pharmacology of the vascular wall. In: Moore WS, ed. Vascular surgery: a comprehensive review. 4th ed. Philadelphia: WB Saunders, 1993:39.
  15. Kamiya A, Togawa T. Adaptive regulation of wall shear stress to flow change in the canine carotid artery. Am J Physiol 1980;239:14-21.
  16. Guyton J, Hartley CJ. Flow restriction of one carotid artery in juvenile rat inhibits growth of arterial diameter. Am J Physiol 1985;248:H540-6.[Abstract/Free Full Text]
  17. Langille B, O'Donnell F. Reductions in arterial diameter produced by chronic decreases in blood flow are endothelium-dependent. Science 1986;23:405-7.
  18. Zarins C, Zatina M, Giddens D, Ku D, Glagov S. Shear stress regulation of artery lumen diameter in experimental atherogenesis. J Vasc Surg 1987;5:413-20.[Medline]
  19. Masuda H, Bassiouny H, Glagov S, Zarins C. Artery wall restructuring in response to increased flow. Surg Forum 1989;45:285-6.
  20. Galt S, Zwolak R, Wagner R, Gilbertson J. Differential response of arteries and vein grafts to blood flow reduction. J Vasc Surg 1993;17:563-70.[Medline]
  21. von Son J, Smedts F, Vincent J, von Lier H, Kubat K. Comparative anatomic studies of various arterial conduits for myocardial revascularization. 1990;99:703-7.
  22. Langille BL, Bendeck MP, Keeley FW. Adaptations of carotid arteries of young and mature rabbits to reduced carotid blood flow. Am J Physiol 1989;256:931-9.
  23. Frangos J, Eskin S, McIntire L, Ives C. Flow effect on prostacyclin production by cultured human endothelial cells. Science 1985;227:1477-9.[Abstract/Free Full Text]
  24. Sims F. A comparison of coronary and internal mammary arteries and implications of the results in the etiology of atherosclerosis. Am Heart J 1983;105:560-6.[Medline]
  25. Kay H, Korns M, Flemma R, Tector A, Lepley DJ. Atherosclerosis of the internal mammary artery. Ann Thorac Surg 1976;21:504-7.[Abstract]
  26. Singh RN, Sosa JA. Internal mammary artery: a "live" conduit for coronary bypass. 1984;87:936-8.
  27. Singh RN, Sosa JA. Internal mammary artery–coronary artery anastomosis: influence of the side branches on surgical result. 1981;82:909-14.
  28. Titus JL, Edwards JE. Congenital heart disease in the adult. In: Willerson JT, Cohn JN, eds. Cardiovascular medicine. New York: Churchill Livingstone, 1995:42.
  29. Fernandez de Caleya D, Duarte J, Eguren A, Torrente N, Lozano A, Nuche J. Combined therapy of coarctation and coronary heart disease in an adult. Thorac Cardiovasc Surg 1993;42:127-9.



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Galili, K. J. Sattler, J. Herrmann, J. Woodrum, M. Olson, L. O. Lerman, and A. Lerman
Experimental hypercholesterolemia differentially affects adventitial vasa vasorum and vessel structure of the left internal thoracic and coronary arteries
J. Thorac. Cardiovasc. Surg., April 1, 2005; 129(4): 767 - 772.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. G. Affleck, H. B. Barner, M. S. Bailey, L. A. Perry, H. Maniar, S. M. Prasad, and R. J. Damiano Jr
Flow Dynamics of the Internal Thoracic and Radial Artery T-Graft
Ann. Thorac. Surg., October 1, 2004; 78(4): 1290 - 1294.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. B. Barner
Remodeling of arterial conduits in coronary grafting
Ann. Thorac. Surg., April 1, 2002; 73(4): 1341 - 1345.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Sasajima, V. Bhattacharya, M. Hong-De Wu, Q. Shi, N. Hayashida, and L. R. Sauvage
Morphology and histology of human and canine internal thoracic arteries
Ann. Thorac. Surg., July 1, 1999; 68(1): 143 - 148.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Sasajima, M. H.-D. Wu, Q. Shi, N. Hayashida, and L. R. Sauvage
Effect of Skeletonizing Dissection on the Internal Thoracic Artery
Ann. Thorac. Surg., April 1, 1998; 65(4): 1009 - 1013.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Lester R. Sauvage
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kouchi, Y.
Right arrow Articles by Sauvage, L. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kouchi, Y.
Right arrow Articles by Sauvage, L. R.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS