|
|
||||||||
J Thorac Cardiovasc Surg 1997;113:585-593
© 1997 Mosby, Inc.
CARDIOPULMONARY BYPASS, |
Supported in part by M.U.R.S.T. grant 05150108-C0533 from the University of Rome "La Sapienza" and by Consiglio Nazionale delle Ricerche grant 95.02471.CT04.
Received for publication Jan. 18, 1996 revisions requested March 18, 1996; revisions received August 5, 1996 accepted for publication August 8, 1996. Address for reprints: Quintilio Caretta, MD, Via G. Giolitti 198, 00185 Rome, Italy.
Abstract
Objective: We evaluated, in the prevention of perioperative unintentional myocardial ischemia, the role of coronary collateral flow in patients with left anterior descending coronary artery stenosis or occlusion who underwent elective coronary artery bypass grafting. Methods: Coronary lesions and collaterals were assessed by coronary angiography in 21 patients. Anteroseptal myocardial viability was evaluated by dobutamine echocardiography. Antegrade perfusion of cardioplegic solution was assessed by myocardial contrast echocardiography. Time-intensity curves were generated from the anteroseptal region. Twelve parameters were measured and averaged in the following four groups of patients: those with stenosis of the left anterior descending artery and poor collaterals; those with stenosis of the left anterior descending artery and good collaterals; those with occlusion of the left anterior descending artery and good collaterals; and those with occlusion of the left anterior descending artery and poor collaterals. Results: Time-intensity curves were significantly different in patients with stenosis versus occlusion of the left anterior descending artery (p < 0.005); multiple comparisons with Bonferroni's correction showed that this difference was mainly a result of the impact of collateral circulation (p < 0.01). However, the role of collaterals was nonsignificant within the groups with stenosis and occlusion of the left anterior descending artery. Patients with occlusion of the left anterior descending artery and good collaterals had perfusion parameters similar to those of patients with stenosis of the left anterior descending artery (p = not significant), except for the ascending slope and time to peak values (p < 0.05 and p < 0.01, respectively), which reflected a higher flow resistance in the collateral circulation. Regional systolic function after coronary artery bypass grafting was depressed in patients with poor collaterals and poor perfusion of cardioplegic solution, as compared with findings in other subgroups. Conclusions: Incomplete myocardial protection may impair the early recovery of function after coronary artery bypass grafting.
The role of coronary collateral circulation in preserving regional myocardial perfusion has been demonstrated by coronary angiography,
1,2 by nuclear methods,
3 and, more recently, by myocardial contrast echocardiography (MCE).
4-8 Coronary angiography detects vessels of greater than 100 µm in diameter and might underestimate collateral flow in patients with poor collateral circulation.
7 Preoperative perfusion imaging techniques may not predict the intraoperative perfusion pattern, because during delivery of cardioplegic solution (1) the flow pattern may be different from that of the beating heart, (2) there is maximal vasodilation of the microcirculation, including collateral vessels, and (3) perfusate-induced endothelial damage may occur.
9,10
MCE may provide information on myocardial perfusion in the beating or arrested heart
4,8,11-17 and may be used to study distribution of cardioplegic solution during coronary artery bypass grafting (CABG).
8,12,14,15 In patients with coronary occlusion, nonhomogeneous distribution of cardioplegic solution delivered in an antegrade manner may cause "unintentional myocardial ischemia," which may lead to myocardial stunning or necrosis.
18-20 In this clinical setting, the role of collateral circulation is critical, and the identification of inadequate myocardial perfusion may help the surgeon plan combined antegrade/retrograde cardioplegia procedures.
4,8,20
The aim of the present study was to evaluate by intraoperative MCE the protective role of coronary collateral flow on preserving myocardial perfusion and function in patients with symptomatic chronic coronary artery disease and proximal left anterior descending artery (LAD) stenosis or occlusion who underwent elective coronary operation.
Methods
Patient selection.
Twenty-one patients undergoing elective CABG because of symptomatic chronic coronary artery disease and proximal lesions of the LAD were enrolled in this study. Approval of the study protocol by the institution's Ethics Committee on Clinical Investigations and informed consent from each patient were obtained. Coronary artery lesions were considered significant when cross-sectional area loss was 75% or greater; arteries were considered occluded when cross-sectional area loss was 100%.
Coronary collateral circulation was classified into two categories (good and poor) on the basis of the degree of opacification of the epicardial segment of the recipient artery on the coronary angiograms.
2 In patients with good collateral circulation, both collaterals and epicardial arteries distal to an occlusion or stenosis were well visualized. Conversely, in patients with poor collateral circulation, the visualization of collaterals and epicardial arteries distal to an occlusion or stenosis was faint. Patients with aortic incompetence or left ventricular aneurysm were excluded from the study. Wall motion was observed in the biplanar left ventriculogram in all patients. Left anteroseptal wall motion was graded on the basis of angiographically determined regional ejection fraction into normal (
50%), impaired (49% to 20%), and severely impaired (<20%). Clinical and coronary angiographic findings are shown in
Table I.
|
Surgical technique.
CABG was done during cardiopulmonary bypass. Systemic hypothermia (25° to 28° C) was maintained throughout the procedure. A total of 79 grafts (average 3.8 ± 1.2 grafts per patient) were placed: 58 were of inverted saphenous vein and 21 of internal thoracic artery. The internal thoracic arteries were always grafted to the LAD.
Cardioplegia techniques.
Myocardial protection was achieved by inducing topical hypothermia with iced saline slush and by administration of cold (4° C) potassium crystalloid cardioplegic solution (30 mEq/L of potassium chloride in the first dose and 15 mEq/L in all the subsequent doses). Cardioplegic solution was infused in an antegrade manner via the aortic root at a pressure of 70 to 80 mm Hg. An initial volume of cardioplegic solution (10 ml/kg) was infused over 2 minutes through the aortic root. Left ventricular venting was done through the left atrium. Administration of cardioplegic solution was repeated every 20 minutes throughout the ischemic period with a 15 mEq/L potassium concentration.
Assessment of myocardial viability.
All patients underwent preoperative (transthoracic) and intraoperative (transesophageal) dobutamine echocardiographic testing at a dose of 5 µg/kg per minute to study myocardial viability in the anteroseptal wall. Preoperative assessment was done in the standard parasternal and apical views, and the anteroseptal wall was assigned one of the following wall motion scores: -1, hyperkinetic; 0, normal; 1, hypokinetic; 2, akinetic; and 3, dyskinetic. The intraoperative assessment was done by single-plane transesophageal echocardiography, with use of a previously reported method.
21 Myocardial wall thickness was measured during the same cardiac cycle at end systole (SWT) and at end diastole (DWT).
21 Percent systolic wall thickening (PSWT) of the anteroseptal wall was calculated according to the formula:
PSWT = (SWT - DWT)/DWT x 100
Serial 12-lead electrocardiograms and cardiac enzyme measurements (creatine kinase MB) were done to exclude the occurrence of perioperative myocardial infarction.
Echocardiographic contrast agent.
The echocardiographic contrast agent was prepared under sterile conditions 1 hour before the operation with use of a standardized protocol developed at the University of Rome, "La Sapienza,"
22 and based on guidelines for albumin sonication developed at the University of Chicago.
23
Perfusion imaging technique.
Aortic incompetence, which may cause inadequate myocardial perfusion during antegrade cardioplegia,
15 was ruled out before bypass by transesophageal echocardiographic color Doppler imaging.
The echocardiographic contrast agent was injected soon after hypothermic arrest through a side branch of the cardioplegia conduit. Two contrast injections of 2 ml were scheduled for each patient during antegrade cardioplegia. The first injection was done during imaging of the aortic valve and the left ventricle to rule out unexpected aortic regurgitation during aortic crossclamping
15; the second injection was done during imaging of the left ventricle in the short-axis view at the level of the papillary muscle to evaluate myocardial perfusion.
Contrast echocardiographic analysis.
Contrast echocardiograms were recorded on SVHS magnetic tape and digitized off-line with use of a 151 Imaging Technology image processor connected with an IBM PS-2 80 computer and displayed on a 512 by 512 pixel screen with 256 gray level scale or intensity units per pixel. One region of interest of at least 100 pixels was drawn in the midanteroseptal wall of the left ventricular myocardium, excluding endocardial and epicardial borders. Quantitative measurements were made by continuous, automatic acquisition at a rate of 15 frames/sec, starting before contrast appearance and continuing for 7 seconds. Background-subtracted time-intensity curves were generated and averaged in four patient groups: those with LAD stenosis and poor collaterals; those with LAD stenosis and good collaterals; those with LAD occlusion and good collaterals; and those with LAD occlusion and poor collaterals. For each curve the following parameters were calculated: time to peak, peak of the curve, area at peak, area under the curve at every 0.5 second up to 7 seconds, and slope of the regression lines fitted to the curve in two segments, ascending slope (from baseline to peak) and descending slope (from peak to the end of the curve). The ascending slope described contrast wash-in in the myocardium and the descending slope described contrast wash-out from the myocardium (see appendix).
Statistical analysis.
Categorical data were presented as absolute frequency. Quantitative measurements were expressed as mean plus or minus the standard deviation. Clinical and angiographic findings were compared by analysis of variance (ANOVA) for quantitative variables and Fisher's exact probability test for categorical variables. PSWT changes in the anteroseptal wall throughout the study were analyzed by paired Student's t test with Bonferroni's correction. PSWT paired values were compared at two steps: baseline versus dobutamine infusion and baseline versus after surgical revascularization. The parameters obtained from the time-intensity curves were analyzed by univariate ANOVA with LAD stenosis versus occlusion and good versus poor collateral circulation as between-subject factors. In particular, the ANOVA model included main effects of LAD disease and collateral circulation and their interaction. Multiple comparisons were done by applying the appropriate t test with Bonferroni's correction. A p value of
0.05 was considered statistically significant; p values between 0.10 and 0.05 are also reported in the tables and text. Statistical analysis was done with BMDP/Dynamic software, release 7.0.
24
Results
Clinical variables among the four patient groups were not statistically different
(Table I).
Preoperative assessment of myocardial viability.
Preoperative dobutamine transthoracic echocardiography showed viable myocardium in the anteroseptal wall in all patients (wall motion score index 0.7 ± 0.8 to -0.4 ± 0.7; p < 0.0001), with clear indication for revascularization in all patients, including those with LAD occlusion and poor collaterals.
Intraoperative perfusion imaging.
Cumulative time-intensity curves generated from the opacification of the anteroseptal myocardium are shown in Fig. 1. Variable values of the curves are presented in
Tables II and
III. Univariate ANOVA showed that patients with LAD occlusion had a significant delay in time to peak, a significant lower peak height of the curve, and a lower area under the curve than patients with LAD stenosis
(Table III). The contrast wash-in, measured by the ascending slope of the curve, and the contrast wash-out, measured by the descending slope of the curve, were significantly lower in patients with LAD occlusion versus respective values in those with LAD stenosis alone. A significant interaction between LAD disease and collateral circulation was found with respect to all parameters, except for time to peak, area at 1 second, and the descending slope
(Table III). Multiple comparison tests showed that the gap between LAD stenosis versus occlusion was mainly a result of the impact of poor collaterals for all the variables, but not the area at peak
(Table IV). Conversely, in the presence of well-developed collateral circulation, a significant difference only persisted between patients with LAD stenosis and patients with LAD occlusion with respect to time to peak and ascending slope of the curve
(Table IV). Furthermore, within the LAD stenosis and LAD occlusion groups, perfusion parameters were not affected by the presence of good or poor collaterals (
Table IV, Fig. 1). The lack of any significant difference in the area at peak among the patient groups was probably related to the different times to peak in each group (Fig. 1,
Tables III and
IV).
|
|
|
|
|
|
|
Discussion
The goal of the cardioprotective approach during cardiac operations is to avoid myocardial stunning or necrosis; however, the ideal approach has not yet been established. Current data suggest that antegrade cardioplegia, in the presence of severe coronary artery stenosis or occlusion, may result in "unintentional myocardial ischemia" because of nonhomogeneous myocardial perfusion and cooling.
18-20 Retrograde cardioplegia can be used as an alternative, but more critical information on the pathophysiologic processes of retrograde perfusion is needed,
20,25 and the right atrial approach cannot be used in patients with either atrial septal defect or patent foramen ovale.
15
Myocardial flow in the arrested heart differs from that in the beating heart and may not be anticipated by preoperative perfusion imaging techniques. For this reason MCE may play a central role in intraoperative myocardial protection protocols because it allows detection of myocardial regions susceptible to inadequate perfusion.
4,6,8,11-15,17 Quantitative MCE can be successfully used to identify myocardial regions that are receiving the least amount of cardioplegic solution, and several parameters derived from time-intensity curves may be used to study regional myocardial flow.
4,13,14 This method allows (1) detection of myocardial regions that escape the ischemic insult
4; (2) improvement of the identification of collateral flow in comparison with coronary angiography
5,6; and (3) evaluation of transmural blood flow distribution.
4
The question related to the adequacy of collateral flow in the prevention of ischemia of the collateralized myocardium is still unanswered.
4,5,8 Coronary collaterals differ in terms of anatomy and flow pattern from the normal arterial vessels because they are characterized by marked endothelial cell proliferation and subintimal hyperplasia.
26,27 On the other hand, it has been demonstrated by temperature probes that good collateral circulation in patients with chronic, stable angina provides homogeneous myocardial cooling that is independent of the route chosen for infusion of cardioplegic solution.
4,8 However, this monitoring technique may be inadequate
28 and is useless when normothermic cardioplegia is used. In addition, data on the protective role of poor collaterals are lacking.
The results of the present study confirm the role of intraoperative MCE in the assessment of regional myocardial flow and the importance of collateral flow in protecting areas fed by an obstructed major coronary vessel. Parameters related to contrast wash-in (time to peak and ascending slope of the curve) and contrast wash-out (descending slope of the curve) were significantly different between patients with LAD stenosis and patients with LAD occlusion (
Tables III and
IV). This finding confirms that during cardioplegia-induced maximal vasodilation collateral circulation represents a resistance to flow that is functionally comparable to a significant stenosis of a native coronary artery.
9,10,29 Blood volume parameters (area under the time-intensity curve and peak of the curve) were not statistically different in the subgroups with LAD stenosis and occlusion when good collaterals were present (
Table IV, good collaterals column). In patients with LAD occlusion the whole area under the curve was not significantly affected by the presence of collateral circulation as shown by preoperative coronary arteriography (Fig. 1;
Table IV, LAD occlusion column). However, when poor collaterals were considered as a grouping factor, perfusion parameters were significantly lower in patients with LAD occlusion in the absence of postoperative electrocardiographic and enzymatic evidence of myocardial infarction. In accordance with the guidelines of the American Society of Anesthesiologists,
30 perioperative echocardiography may allow detection of poorly protected myocardial segments that have an increased risk of "unintentional perioperative myocardial ischemia."
Limitations.
The limitations of this study are related to the following factors.
Contrast agent.
Different batches of sonicated albumin may have different concentrations and size distributions, which may significantly affect ultrasonographic reflection. Peak contrast and area under the curve are more affected than contrast wash-in and wash-out parameters. Coulter or laser counting (Coulter Electronics, Hialeah, Fla.), microscopic analysis, and ultrasonic characterization may be used to determine bubble size and concentration; however, these methods are not free from limitations. Microscopic evaluation, although time consuming, is an acceptable method for this purpose and may be used to unequivocally exclude the presence of large bubbles.
Injection technique.
Sonicated albumin microbubbles may be unstable under pressure and may collapse or be destroyed during manual injection. In addition, both the speed of contrast injection and infusion of cardioplegic solution may not be constant.
Imaging modality.
Myocardial reflectivity may vary with changes in heart position. In addition, at low contrast concentration, myocardial perfusion may be underestimated because of the threshold effect; similarly, at high contrast concentration compression and attenuation of the signal by the commercially available ultrasonographic system may result in perfusion underestimation.
MCE is more sensitive than coronary arteriography in detecting perfusion of the collateralized myocardium
5-7; thus the assignment of patients to groups with "good" and "poor" collaterals on the basis of coronary angiography may be misleading.
Conclusions.
We conclude that intraoperative MCE allows the assessment of myocardial perfusion in the cardioplegia-arrested heart when a complete analysis of all the time-intensity curve variables is done.
Infusion of cardioplegic solution through the aortic root provides adequate myocardial perfusion in the presence of well-developed collateral circulation. Poor collateral circulation is characterized by a high resistance to flow and in this clinical setting coronary angiography may not predict the intraoperative perfusion pattern. In the subset of patients with LAD occlusion and poor collaterals, antegrade cardioplegia may not provide complete myocardial protection, and alternative protective techniques may be used to avoid "unintentional myocardial ischemia," perioperative myocardial necrosis, or myocardial stunning.
Appendix
The following notations are used herein:
xi = acquisition time (i = 0, 1, 2, ..., k, ..., 14, which correspond to xi = 0 second, 0.5 second, 1 second, ..., k/2 seconds, ..., 7 seconds)
= mean of xi values
yi = background-subtracted intensity value at time xi
= mean of yi values
k = index of the last measure within each time interval (k = 2, 4, ..., 14 for area at 1 second, area at 2 seconds, ..., area at 7 seconds, respectively)
k = index of the time to peak and of the peak height
Peak height and time to peak of the curve were defined as follows:

Time to peak = x* = acquisition time of the first usable y*
The other parameters of the curve were calculated from the following formulas:

* Peak values
Footnotes
From the University of Florence,a Florence; the Department of Cardiac Surgery, "La Sapienza" University of Rome,b Rome; and the Istituto Superiore di Sanità, Ministero della Sanità,c Rome, Italy. ![]()
References
This article has been cited by other articles:
![]() |
P. Voci The bubbles and the science of life J. Am. Coll. Cardiol., August 1, 2000; 36(2): 625 - 627. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |