JTCS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
David F. Torchiana
Mortimer J. Buckley
Cary W. Akins
W. Gerald Austen
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Torchiana, D. F.
Right arrow Articles by Austen, W. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Torchiana, D. F.
Right arrow Articles by Austen, W. G.

J Thorac Cardiovasc Surg 1997;113:758-769
© 1997 Mosby, Inc.


CARDIOPULMONARY BYPASS,
MYOCARDIAL MANAGEMENT, AND SUPPORT TECHNIQUES

INTRAAORTIC BALLOON PUMPING FOR CARDIAC SUPPORT: TRENDS IN PRACTICE AND OUTCOME, 1968 TO 1995

David F. Torchiana, MD, Gregory Hirsch, MD, Mortimer J. Buckley, MD, Chiwon Hahn, MD, John W. Allyn, MD, Cary W. Akins, MD, John F. Drake, John B. Newell, W. Gerald Austen, MD, From the Department of Surgery, Massachusetts General Hospital, Boston, Mass.

Supported by a grant from St. Jude Medical, Inc., St. Paul, Minn.

Received for publication May 6, 1996 revisions requested July 10, 1996; revisions received Nov. 19, 1996 accepted for publication Dec. 18, 1996. Address for reprints: David F. Torchiana, MD, Massachusetts General Hospital, Boston, MA 02114.

Abstract

Objectives: A total of 4756 cases of intraaortic balloon pump support have been recorded at the Massachusetts General Hospital since the first clinical insertion for cardiogenic shock in 1968. This report describes the patterns of intraaortic balloon use and associated outcomes over this time period.

Methods: A retrospective record review was conducted.

Results: Balloon use has increased to more than 300 cases a year at present. The practice of balloon placement for control of ischemia (2453 cases, 11.9% mortality) has become more frequent, whereas support for hemodynamic decompensation (congestive heart failure, hypotension, cardiogenic shock) has been relatively constant (1760 cases, 38.2% mortality). Mean patient age has increased from 54 to 66 years, and mortality has fallen from 41% to 20%. Sixty-five percent (3097/4756) of the total patient population receiving balloon support underwent cardiac surgery. Placement before the operation (2038 patients) was associated with a lower mortality (13.6%) than intraoperative (771 patients, 35.7% mortality) or postoperative use (276 patients, 35.9% mortality). Independent predictors of death with balloon pump support were insertion in the operating room or intensive care unit, transthoracic insertion, age, procedure other than angioplasty or coronary artery bypass, and insertion for cardiogenic shock. Independent predictors of death with intraoperative balloon insertion were age, mitral valve replacement, prolonged cardiopulmonary bypass, urgent or emergency operation, preoperative renal dysfunction, complex ventricular ectopy, right ventricular failure, and emergency reinstitution of cardiopulmonary bypass.

Conclusions: Balloons are being used more frequently for control of ischemia in more patients who are elderly with lower mortality. An institutional bias toward preoperative use of the balloon pump appears to be associated with improved outcomes.

The intraaortic balloon pump (IABP) represents a successful clinical application of the principle of counterpulsation.Go Go 1,2 IABP support can produce a modest increment in forward output in the injured or failing heart,Go Go 3,4 but the most obvious efficacy both theoretically and empirically is in the setting of ischemia resulting from coronary artery disease. With appropriate timing to the cardiac cycle, the IABP can both decrease cardiac work by deflating during systole and reduce afterload and augment coronary perfusion by inflating during diastole. This simultaneous improvement in coronary flow and reduction in myocardial oxygen consumption is a unique benefit of the IABP and other methods of mechanical support.

The first clinical experience with the IABP was in patients with cardiogenic shock after myocardial infarction.Go Go 5,6 Although outcomes were initially poor, with high mortality, significant hemodynamic improvement was documented, which encouraged continued investigation.Go 7 In 1972, Buckley, Craven, and GoldGo 8 reported 27 cases in which the IABP was used in patients unable to be weaned from cardiopulmonary bypass by conventional means. Eighteen were weaned from the balloon, and 13 survived and were discharged from the hospital. In the 25 years since these initial reports nearly 5000 IABPs have been used at the Massachusetts General Hospital (MGH). In this retrospective review we describe the evolution in indications, techniques, and results over this period.

Patients and methods

A total of 4756 cases of IABP insertion were registered in a log maintained by the cardiac procedures service. The hospital records of these patients were reviewed. The information abstracted from each record is shown in Appendix 1. The data fields were entered into a computerized database, prospectively since 1986 and retrospectively before that time.

The population reviewed encompassed all patients who were supported by an IABP from 1968 to June 1995. A subset of these (3097) underwent a cardiac surgical procedure during the same hospitalization. This cohort is referred to as the perioperative IABP group and includes patients in whom the balloon was placed before the operation (preoperative IABP), in the operating room during a cardiac surgical procedure (intraoperative IABP), or after the operation in the surgical intensive care unit (postoperative IABP). In a group of 193 consecutive patients who had intraoperative IABP insertions between 1985 and 1993, a further data set (Appendix 2) was obtained retrospectively and analyzed.

Multivariable probability models were constructed from the two sets of data with the use of BMDP program LR (BMDP Statistical Software, Inc, Los Angeles, Calif., Release 7, 1992). The candidate variables for the models are shown in Appendices 1 and 2. The purpose of these models was to describe the risk factors for the outcome predicted. Accordingly, a reference specifying standards for the use of such models was applied in the analyses.Go 9

Each model was fit with a stepwise forward stepping algorithm with the asymptotic covariance estimate used for entering variables into the model. In each step a variable was entered when the F statistic to enter the variable had a tail-probability value less than 0.01, and a variable was removed during a step when the tail-probability of the F statistic to remove was more than 0.05. Variables could enter or be removed twice from the model during the stepping. So that the data would not be overfitted, the stepping was stopped before the number of variables admitted into the model exceeded one tenth the number of events (deaths). To allow for nonconformity to a linear gradient among predictor variables, the continuous variables were divided into a small number of categoric ranges chosen from cross-tabulations against actual mortality and from clinicians' judgment of ranges likely to have different rates; for example, age was recoded into three categories: age less than 70 years, age between 70 and 80 years, and age more than 80 years.

Pairwise interactions among all candidate variables were entered as candidate predictors according to the hierarchical rule available in the logistic regression program; that is, no interaction could be entered into the model unless its two underlying variables were already in the model. No such interactions were found in either of our models (all that would have satisfied the criteria for entry would have required overfitting of the model to enter). The coding of all predictor variables is shown in the two appendices or in GoTables IV and GoV. The program LR tests for collinearity of predictor variables, either by failing to converge when collinear variables are selected into the model or by attempting to remove a variable if a collinear variable is selected into the model. We found no such cases in our models. The problem of influential outlier variables was addressed by reviewing numerous cross-tabulations of the data and by cross-checking the work of the data collection personnel. Data entry errors were caught and corrected in this manner.


View this table:
[in this window]
[in a new window]
 
Table IV. Multivariate predictors of death in all patients (medical and surgical) supported by an IABP from 1968 to 1995
 

View this table:
[in this window]
[in a new window]
 
Table V. Multivariate predictors of death with IABP insertion during 193 cardiac surgical procedures between 1985 and 1993
 
The mathematical fit of each model was checked with the use of the Hosmer-Lemeshow goodness of fit {chi}2 test in the LR program. No model was accepted unless the tail p value for this statistic was large (>0.2). In addition, the areas under the receiver operator characteristic curves for the models were computed to assess the goodness of fit. For these models these are equivalent to the c-statistic or concordance index, the fraction of all pairs of patients, one survivor and one who died, for which the model predicted a higher probability of survival for the member of the pair who actually survived.Go 10 The receiver operator characteristic areas were 0.78 for the overall mortality model and 0.89 for mortality among 193 patients supported with an IABP. Prospective validation of the probability models remains to be carried out, although modeling among a small number of random subsets of the patients produced similar results.

Results

To illustrate changes in some of the patterns of use, we divided the data into 5-year intervals Go(Table I). During the period studied, average patient age increased from 54 to 66 years and the percent of patients older than age 70 years increased from 2.1% to 38%. Despite this, mortality fell from 41% to 20%. The technique of insertion was initially 99% surgical via a femoral artery. In 1980 percutaneous insertionGo Go 11-13 was introduced, and in current practice 97% of balloons are placed percutaneously. Throughout this period, there has been a small incidence (1.9%) of transthoracic balloon insertions via the ascending aorta when intraoperative balloon insertion is necessary and the femoral route in unsuccessful.


View this table:
[in this window]
[in a new window]
 
Table I. Trends in IABP use divided into 5-year intervals (1968-1995)
 
As the technique of balloon insertion has changed from surgical to almost exclusively percutaneous, the major geographic location of insertion has shifted from the intensive care unit or operating room to the cardiac catheterization laboratory. In the past 5 years, 16% of balloons were placed in the operating room or intensive care unit as opposed to 87% in the late 1970s. With this change, the institution of IABP support has largely been transferred from the hands of the surgeon to those of the cardiologist.

A total of 3097 patients underwent cardiac surgery before, after, or concomitant with IABP insertion. Perioperative IABP usage has declined as a percentage of all IABPs from a high of 84% to 54% in the most recent interval. The percentage of patients undergoing angioplasty has gone from 0% to 31%. Mortality for patients receiving IABP support and undergoing angioplasty was 14.7%.

Although the number of patients supported by an IABP for hemodynamic decompensation (congestive heart failure, hypotension, and cardiogenic shock) has been fairly constant, support for ongoing ischemia has become much more frequent Go(Table II). The logistic and technical simplicity of percutaneous insertion had a major role in this trend. The mortality associated with IABP placement for ischemia over the entire series was 11.9% and for hemodynamic decompensation, 38.2%.


View this table:
[in this window]
[in a new window]
 
Table II. Trends in indications for IABP
 
In GoTable III the incidence of complications for the series as a whole is summarized. Because of the nature of a retrospective review, certain complications, particularly passage failure with percutaneous IABP, may be underreported. Balloon rupture has been more frequent in the recent era and is strongly influenced by age, presumably because of the increasing severity of calcific aortic atherosclerosis in older patients.


View this table:
[in this window]
[in a new window]
 
Table III. Complications of IABP
 
The independent predictors of mortality for all patients supported by IABP are shown in GoTable IV. Notable among these were insertion of the IABP in the operating room or intensive care unit, transthoracic insertion, age, procedure other than coronary artery bypass grafting or angioplasty, and insertion for cardiogenic shock. Placement for ongoing ischemia and for associated coronary artery bypass grafting or angioplasty were associated independently with a better outcome.

The results of the multivariate analysis of predictors of mortality in 193 intraoperative IABP insertions are shown in GoTable V. Mortality was 32% during this interval, slightly less than the 35.7% mortality for intraoperative insertion in the entire series. The independent predictors of death in these patients were age, mitral valve replacement, prolonged cardiopulmonary bypass, urgent or emergency operation, preoperative renal dysfunction, and complex ventricular ectopy or right ventricular failure after crossclamp removal. The timing of IABP insertion was important: placement after separation from bypass was associated with a better outcome than placement to wean from bypass; the outcome of placement after emergency reinstitution of bypass was worse. Postoperative acidosis and oliguria were associated with a higher risk of death.

Discussion

The evolution of demographics and practice observed conform with generalized trends throughout medicine toward improved results with less invasive treatment of more patients who are elderly.

There are two areas in which the data may be misleading. The first is the reduction in mortality observed over time despite the increasing age of the population. Some of this might reflect advances in critical care, surgery, and anesthesia as well as the inception of angioplasty, but there has also undoubtedly been a change in indications for IABP support such that the patients who are receiving IABP support at the present time represent a less sick population (see GoTable II).

Second, there was an apparent increase in vascular complications with the introduction of percutaneous insertion in 1980 (see GoTable I). Whether this represents a true change in morbidity is questionable. For the purpose of this tabulation, vascular complications were defined as cases in which surgical treatment was required for limb ischemia, bleeding, or vessel injury. Mesenteric infarction, amputation, and aortic dissection were also included. Limb ischemia that resolved with balloon removal and localized arterial injury that did not require surgery were not included. This is a relatively narrow definition of vascular complications and probably understates their incidence compared with that reported in other series.Go Go 11-17 With the change from surgical to percutaneous IABP insertion there was an immediate major reduction in the number of groin operations done overall, because a surgical balloon by definition requires an operation to place and remove the device whereas percutaneous insertion requires surgery only when there is a complication. More than 90% of percutaneous balloons are removed without the need for surgery, and the majority of vascular surgical procedures after percutaneous balloon removal are simple thrombectomies or patch angioplasties of no greater magnitude than surgical balloon placement or removal. Catastrophic vascular complications (iliac or aortic perforation, mesenteric infarction, amputation) have remained at less than 1% throughout the series after initially appearing to be more frequent with the first 100 balloons placed by the percutaneous technique.Go 17

In recent years, surgical series from St. Louis University and Washington UniversityGo Go 18,19 have reported institutional patterns of IABP use and associated mortality. In GoTable VI the last 15 years of our data on perioperative IABP use at the MGH are displayed with data from these other series. The rate of IABP use as a percentage of all cardiac operations was higher at the MGH: 12.3% versus 8.5 and 9.8%. A higher percentage of perioperative balloons were placed before the operation in our series (70.6% vs 35.7% and 18.8% of perioperative balloons). Intraoperative and postoperative IABP use was correspondingly less frequent at the MGH (3.6% of all cardiac operations vs 6.3% and 6.8%). This strong bias toward early balloon insertion is an established tenet of cardiology practice at the MGH because the decision to place a balloon more frequently occurs at the time of catheterization before surgical consultation.


View this table:
[in this window]
[in a new window]
 
Table VI. Comparison with other surgical series
 
Although the association cannot be proved to be causal, the mortality associated with this practice is lower (16.3% vs 28.7% and 44.0%), and it is our impression that liberal use of IABP support to stabilize medically refractory ischemia in the preoperative interval reduces overall surgical mortality Go(Table VII). Our preference has been to allow 24 to 48 hours of IABP support to quiet unstable or postinfarction angina and permit recovery of ischemic myocardium before operation as opposed to undertaking an immediate operation in the setting of ongoing ischemia. Persistent angina, hemodynamic instability, or limb-threatening ischemia in the leg into which the balloon was inserted may still necessitate an emergency operation in some instances. OthersGo 20 have noted the efficacy of early IABP therapy in surgical patients with unstable coronary syndromes. A reduction in mortality in patients having emergency/urgent coronary bypass grafting from 31% to 0% was associated with an increase in preoperative IABP use from 24% to 89% of these cases.


View this table:
[in this window]
[in a new window]
 
Table VII. Outcomes with perioperative IABP in the percutaneous era (mortality since 1980)
 
It is possible that the lower mortality associated with preoperative balloon use may reflect a propensity to use IABP support prophylactically in stable patients with high-risk anatomy. This can have only a modest influence, because just 7% of our perioperative insertions since 1980 have been prophylactic, with an 11% mortality rate, which is not lower than that of other patients receiving preoperative IABP support. Finally, it is unlikely that these results can be attributed to recent advances in myocardial protection, because the techniques used at the MGH in the cases reported are a mixture of the spectrum of methods through the history of cardiac surgery, including hypothermic fibrillatory arrest, crystalloid cardioplegia, cold blood cardioplegia, and warm continuous blood cardioplegia.

Given that one of the areas in which mortality remains highest is the subgroup of patients undergoing balloon insertion during and after heart surgery, it is logical to ask whether intervention with a ventricular assist device (VAD) in some of these patients might produce a better outcome. Previous attemptsGo Go 21,22 at determining which patients are at greatest risk of death with intraoperative IABP insertion include a prospectively validated model developed by Baldwin, Slogoff, and Noon.Go 22 Their model describes the need for pacing, preoperative renal dysfunction, advanced age, female sex, and prolonged cardiopulmonary bypass as positive predictors of death. Our analysis had similar findings although sex was not found to be an independent predictor. Among the other variables we found not to be predictive of mortality with IABP insertion were preoperative or postoperative myocardial infarction, number or dose of inotropic agents, preoperative left ventricular function, cardiac output before or after the operation, peripheral vascular disease, diabetes, reoperation, and left main disease.

The independent predictors of death with intraoperative insertion shown in GoTable V can be combined into a prediction formula that has an 80% sensitivity and specificity in this retrospective population but has not been prospectively validated. The practical usefulness of such a model is limited in that some of the predictive elements are generalized risk factors for death after heart surgery and do not clarify which portion of the population at risk is most likely to be salvaged by VAD support. For example, elderly patients with prior renal dysfunction and long bypass runs may be just as likely to do poorly with VAD support as with an IABP. Ideally, we would like to be able to identify the subgroup of patients who are both at high risk of death with IABP and have the best likelihood of survival with a VAD.

Theoretically, the subset of patients that would be best served by temporary VAD support are those with profound hemodynamic compromise but a technically corrective cardiac operation with reversible injury. In our limited institutional experience, 14 patients were supported with a VAD after cardiac operations between 1986 and 1995. Four were successfully bridged to transplantation, and three of these survived. A fifth patient was weaned from the VAD and is a long-term survivor. As experience with VAD support after cardiotomy is acquired in greater numbers, the question can be addressed more substantially.

In conclusion, the use of IABP support has steadily become more prevalent although still with a significant associated mortality and complication rate. The data presented are limited by being uncontrolled and retrospective, but it is our impression that liberal preoperative balloon use to quiet unstable coronary syndromes can reduce surgical mortality and the need for IABP placement during and after the operation. The risk of death with IABP use remains high, but models to predict death in this setting may not identify the best candidates for VAD support.

Appendix: Discussion

Dr. D. Glenn Pennington
(Winston-Salem, N.C.). Dr. Torchiana and his colleagues at the MGH have presented a superb report of one of the oldest and largest IABP experiences in the world, and they have demonstrated an encouraging decline in the overall mortality and vascular complication rate. Furthermore, their criteria for use indicate a dramatic decrease in the hemodynamic indication and a sharp increase in the indication for unstable angina, a fact that probably accounts for most of the improvement in the mortality rate.

Our interest centers more around the group of patients who required IABPs in conjunction with cardiac surgery. The authors report a higher frequency of perioperative use, 12%, than most other centers. Moreover, more than 70% of the cardiac surgery IABPs were placed before the patient was taken to the operating room. We assume that most of those patients were not in cardiogenic shock and had balloons placed prophylactically or to stabilize unstable angina. Might some of these patients without hemodynamic compromise have done just as well without a balloon? However, hemodynamic stabilization of patients before coming to the operating room makes inherently good sense, and this practice has probably been underused in many of our centers. We are indebted to the MGH group for bringing this to our attention.

Because a large number of our patients are currently referred for unstable angina, I wish to ask what criteria should be used in a patient group with such wide variations. If every patient with so-called unstable angina received an IABP before the operation, the cost would become significant.

In the last subset of patients analyzed, there are 193 patients who did receive their balloons in the operating room or intensive care unit. In this group the 32% mortality rate was more in keeping with that reported from other centers. The authors tried to determine whether VADs might have been more helpful than IABPs in this group, and they could project a potential 40% survival in this group if they had received VADs. Perhaps that would be significant. In any case, I believe that the 32% mortality rate in patients requiring operative IABP placement is still unacceptable and that we are obligated to evaluate the effect of a more complete form of circulatory support, such as a VAD, in these desperately ill patients.

I would put forward four questions. One, how many of the patients without hemodynamic compromise might have done well without IABPs? Two, which patients with unstable angina should receive preoperative IABPs? Three, what role should VADs play? Four, would the authors support a randomized study of IABP versus VAD for patients requiring intraoperative support for hemodynamic compromise?

Dr. Torchiana.
I would like to thank Dr. Pennington for his questions. The answers to these questions are a matter of opinion and practice rather than a matter of definitive fact. I think the fact that the percentage of balloons used at MGH is around a quarter to a third higher than at other comparable institutions but the mortality rate significantly lower suggests that we are not overusing balloons, but, rather, that they are being underused in the preoperative period at other institutions. Undoubtedly, a certain percentage of patients brought to the operating room at our institution with a preoperative IABP did not need to have it placed. However, prophylactic use is not a major indication for balloon use at our institution, because only 7% of the patients in this report had prophylactic balloons.

In general, the major use of the balloon was for the stabilization of unstable angina. These are patients in whom angina cannot be controlled by intravenous nitroglycerin and other attempts at medical therapy. If a balloon is placed in these patients and the angina subsides, it is our conviction that allowing the patient 24 to 48 hours of IABP support rather than an immediate operation is preferable.

Which patients might best be benefited by a VAD insertion in the operating room is a difficult question. When you identify the patients most likely to die with an IABP insertion, you have really identified a very sick group of patients who are unlikely to do well with a VAD either. The most logical way to approach this, as Dr. Pennington suggests, is to randomize the insertion of an IABP or a VAD in this group.

Dr. Robert A. Guyton
(Atlanta, Ga.). I lived in the MGH from 1970 until 1980 and think that I have probably inserted 100 or so of these balloons. My question has to do with the patients who had balloons inserted who did not come to the operating room. You report between 1980 and the present a 16% mortality in patients who were operated on with IABP support, but you report about a 21% mortality overall for balloon usage. That means that the mortality of the patients who had the balloon inserted and did not go to the operating room must be 30% or 35%. Did patients, for example, who had a major catastrophe at the time of IABP insertion in the preoperative period not get operated on and therefore not enter into the numerator of your perioperative deaths of patients with IAPBs?

Dr. Torchiana.
That is an excellent point, Dr. Guyton, and I do not think there is any way that I can prove or refute what you are saying. The patients in whom a balloon is placed who do not respond with relief of ischemia or patients in whom a balloon is placed for an acute mechanical complication of myocardial infarction, like papillary muscle rupture or postinfarction ventricular septal defect, go immediately to the operating room, as do patients with a balloon in an ischemic limb. Those groups are not turned away from surgical treatment. However, I agree that it is possible that surgical selection is at play and some patients who receive an IABP and do very, very badly therefore die without surgical treatment. Yours is a valid observation and probably may still be the correct way to do things. Not all patients in whom a balloon is placed are candidates for surgery.


View this table:
[in this window]
[in a new window]
 
Table 1. Data form for all balloon insertions, 1968 to 1995
 

View this table:
[in this window]
[in a new window]
 
Table 2. IABP insertion data form
 
Footnotes

Read at the Seventy-sixth Annual Meeting of The American Association for Thoracic Surgery, San Diego, Calif., April 28–May 1, 1996. Back

References

  1. Clauss RH, Birtwell WC, Albertal G. Assisted circulation. I. The arterial counterpulsator. J Thorac Cardiovasc Surg 1961;41:447-58.
  2. Moulopoulos SD, Topaz S, Kolff WJ. Diastolic balloon pumping (with carbon dioxide) in the aorta: a mechanical assistance to the failing circulation. Am Heart J 1962;63:669-75.[Medline]
  3. Powell WJ Jr, Daggett WM, Magro AE. Effects of intraaortic balloon counterpulsation on cardiac performance, oxygen consumption and coronary blood flow in dogs. Circ Res 1970;26:753.[Abstract/Free Full Text]
  4. Bolooki H. Physiology of balloon pumping. In: Bolooki H, editor. Clinical application of the intra-aortic balloon pump. Mt. Kisco [NY]: Futura, 1984:57-126.
  5. Kantrowitz A, Tjonneland S, Freed PS. Initial clinical experience with intraaortic balloon pumping in cardiogenic shock. JAMA 1968;203:135-40.
  6. Buckley MJ, Leinbach RC, Kastor JA. Hemodynamic evaluation of intraaortic balloon pumping in man. Circulation 1970;41,42:130-36.
  7. Kantrowitz A. Origins of intraaortic balloon pumping. Ann Thorac Surg 1990;50:672-4.[Abstract/Free Full Text]
  8. Buckley MJ, Craven JM, Gold HK. IABP assist for cardiogenic shock after cardiopulmonary bypass. Circulation 1972;46(Suppl):II76.
  9. Concato J, Feinstein AR, Holford TR. The risk of determining risk with multivariable models. Ann Intern Med 1993;118:201-10.[Medline]
  10. Braitman LE, Davidoff F. Predicting clinical states in individual patients. Ann Intern Med 1996;125:406-12.[Medline]
  11. Bregman D, Nichols AB, Weiss MB, et al. Percutaneous intraaortic balloon insertion. Am J Cardiol 1980:46;261-4.
  12. Subramanian VA, Goldstein JE, Sos TA, et al. Preliminary clinical experience with percutaneous intraaortic balloon pumping. Circulation 1980;62(Suppl)I123-9.
  13. Leinbach RC, Goldstein J, Gold HK. Percutaneous wire-guided balloon pumping. Am J Cardiol 1982:49:1707-10.
  14. McEnany MT, Kay HR, Buckley MJ. Clinical experience with intraaortic balloon pump support in 728 patient. Circulation 1978;58:3:I124-31.[Abstract/Free Full Text]
  15. Pinkard J, Utley JR, Leyland SA. Relative risk of aortic and femoral insertion of intraaortic balloon pump after coronary artery bypass grafting procedures. J Thorac Cardiovasc Surg 1993;105:721-8.[Abstract]
  16. Barnett MG, Swartz MT, Peterson GJ. Vascular complications from intraaortic balloons: risk analysis. J Vasc Surg 1994;19:81-9.[Medline]
  17. Martin RS, Moncure AC, Buckley MJ. Complications of percutaneous intra-aortic balloon insertion. J Thorac Cardiovasc Surg 1983;85:186-90.[Medline]
  18. Creswell LL, Rosenbloom M, Cox JL. Intraaortic balloon counterpulsation: patterns of usage and outcome in cardiac surgery patients. Ann Thorac Surg 1992;54:11-20.[Abstract/Free Full Text]
  19. Naunheim KS, Swartz MT, Pennington DG. Intraaortic balloon pumping in patients requiring cardiac operations: risk analysis and long-term follow-up. J Thorac Cardiovasc Surg 1992;104:1654-61.[Abstract]
  20. Dziuban SW, McIlduff JB, Miller SJ. How a New York cardiac surgery program uses outcomes data. Ann Thorac Surg 1994:58:1871-6.
  21. Pi K, Block PC, Warner MG. Major determinants of survival and nonsurvival of intraaortic balloon pumping. Am Heart J 1995;130:849-53.[Medline]
  22. Baldwin RT, Slogoff S, Noon GP. A model to predict survival at time of postcardiotomy intraaortic balloon pump insertion. Ann Thorac Surg 1993:55:908-13.



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
V. Mannacio, L. Di Tommaso, V. De Amicis, P. Stassano, F. Musumeci, and C. Vosa
Preoperative Intraaortic Balloon Pump for Off-Pump Coronary Arterial Revascularization
Ann. Thorac. Surg., March 1, 2012; 93(3): 804 - 809.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Miceli, S. M. J. Duggan, R. Capoun, F. Romeo, M. Caputo, and G. D. Angelini
A Clinical Score to Predict the Need for Intraaortic Balloon Pump in Patients Undergoing Coronary Artery Bypass Grafting
Ann. Thorac. Surg., August 1, 2010; 90(2): 522 - 526.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
I. D. Gregoric, P. Loyalka, R. Radovancevic, Z. Jovic, O.H. Frazier, and B. Kar
TandemHeart as a Rescue Therapy for Patients With Critical Aortic Valve Stenosis
Ann. Thorac. Surg., December 1, 2009; 88(6): 1822 - 1826.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. Nardi, A. Pellegrino, A. Scafuri, D. Colella, C. Bassano, P. Polisca, and L. Chiariello
Long-Term Outcome of Coronary Artery Bypass Grafting in Patients With Left Ventricular Dysfunction
Ann. Thorac. Surg., May 1, 2009; 87(5): 1401 - 1407.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
E. C. McGee Jr., P. M. McCarthy, and N. Moazami
Temporary Mechanical Circulatory Support
, January 1, 2008; 3(2008): 507 - 534.
[Full Text]


Home page
CirculationHome page
A. F. Hernandez, J. D. Grab, J. S. Gammie, S. M. O'Brien, B. G. Hammill, J. G. Rogers, M. T. Camacho, M. K. Dullum, T. B. Ferguson, and E. D. Peterson
A Decade of Short-Term Outcomes in Post Cardiac Surgery Ventricular Assist Device Implantation: Data From the Society of Thoracic Surgeons' National Cardiac Database
Circulation, August 7, 2007; 116(6): 606 - 612.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovascular and Thoracic AnnalsHome page
H. Kazaz, E. Hazan, O. Oto, N. Sariosmanoglu, and N. A. Dereli
Postcardiotomy Extracorporeal Life Support
Asian Cardiovascular and Thoracic Annals, December 1, 2006; 14(6): 485 - 488.
[Abstract] [Full Text] [PDF]


Home page
 Journal of International Medical ResearchHome page
O. Hein, J. Birnbaum, K. Wernecke, W. Konertz, and C. Spies
Intensive Care Unit Stay of More than 14 Days after Cardiac Surgery is Associated with Non-cardiac Organ Failure
Journal of International Medical Research, November 1, 2006; 34(6): 695 - 703.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. D. Adams, L. M. Fedoruk, C. A. Tache-Leon, B. B. Peeler, J. A. Kern, C. G. Tribble, J. D. Bergin, and I. L. Kron
Does Preoperative Ejection Fraction Predict Operative Mortality With Left Ventricular Restoration?
Ann. Thorac. Surg., November 1, 2006; 82(5): 1715 - 1720.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. V. Hein, J. Birnbaum, K. Wernecke, M. England, W. Konertz, and C. Spies
Prolonged Intensive Care Unit Stay in Cardiac Surgery: Risk Factors and Long-Term-Survival
Ann. Thorac. Surg., March 1, 2006; 81(3): 880 - 885.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovascular and Thoracic AnnalsHome page
M. Pawar, Y. Mehta, A. Ansari, R. Nair, and N. Trehan
Nosocomial Infections and Balloon Counterpulsation: Risk Factors and Outcome
Asian Cardiovascular and Thoracic Annals, December 1, 2005; 13(4): 316 - 320.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. Onorati, L. Cristodoro, P. Mastroroberto, A. di Virgilio, A. Esposito, M. Bilotta, and A. Renzulli
Should We Discontinue Intraaortic Balloon During Cardioplegic Arrest? Splanchnic Function Results of a Prospective Randomized Trial
Ann. Thorac. Surg., December 1, 2005; 80(6): 2221 - 2228.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
I. R. Ramnarine, A. D. Grayson, W. C. Dihmis, N. K. Mediratta, B. M. Fabri, and J. A. C. Chalmers
Timing of intra-aortic balloon pump support and 1-year survival
Eur J Cardiothorac Surg, May 1, 2005; 27(5): 887 - 892.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. J. F. Baskett, G. T. O'Connor, G. M. Hirsch, W. A. Ghali, K. Sabadosa, J. R. Morton, C. S. Ross, F. Hernandez, W. C. Nugent Jr, S. J. Lahey, et al.
A multicenter comparison of intraaortic balloon pump utilization in isolated coronary artery bypass graft surgery
Ann. Thorac. Surg., December 1, 2003; 76(6): 1988 - 1992.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
R. Salenger, J. S. Gammie, and T. J. Vander Salm
Postoperative Care of Cardiac Surgical Patients
, January 1, 2003; 2(2003): 439 - 469.
[Full Text]


Home page
Card Surg AdultHome page
N. Moazami and P. M. McCarthy
Temporary Circulatory Support
, January 1, 2003; 2(2003): 495 - 520.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
J. T. Christenson, M. Cohen, J. J. Ferguson III, R. J. Freedman, M. F. Miller, E. M. Ohman, R. C. Reddy, G. W. Stone, and P. M. Urban
Trends in intraaortic balloon counterpulsation complications and outcomes in cardiac surgery
Ann. Thorac. Surg., October 1, 2002; 74(4): 1086 - 1090.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. J.F. Baskett, W. A. Ghali, A. Maitland, and G. M. Hirsch
The intraaortic balloon pump in cardiac surgery
Ann. Thorac. Surg., October 1, 2002; 74(4): 1276 - 1287.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
D. Bainbridge and D. Cheng
Initial Perioperative Care of the Cardiac Surgical Patient
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2002; 6(3): 229 - 236.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. Hedayati, J. T. Sherwood, S. J. Schomisch, J. L. Carino, and B. L. Cmolik
Circulatory benefits of diastolic counterpulsation in an ischemic heart failure model after aortomyoplasty
J. Thorac. Cardiovasc. Surg., June 1, 2002; 123(6): 1067 - 1073.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
Z. S. Meharwal and N. Trehan
Vascular complications of intra-aortic balloon insertion in patients undergoing coronary reavscularization: analysis of 911 cases
Eur J Cardiothorac Surg, April 1, 2002; 21(4): 741 - 747.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. A. Pinkney, L. L. Minich, L. Y. Tani, G. B. Di Russo, L. G. Veasy, E. C. McGough, and J. A. Hawkins
Current results with intraaortic balloon pumping in infants and children
Ann. Thorac. Surg., March 1, 2002; 73(3): 887 - 891.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Kang, M. Edwards, and R. Larbalestier
Preoperative intraaortic balloon pumps in high-risk patients undergoing open heart surgery
Ann. Thorac. Surg., July 1, 2001; 72(1): 54 - 57.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. G. Smedira and E. H. Blackstone
Postcardiotomy mechanical support: risk factors and outcomes
Ann. Thorac. Surg., March 1, 2001; 71(2007): S60 - S66.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. E. Gutfinger, R. A. Ott, M. Miller, A. Selvan, M. A. Codini, H. Alimadadian, and T. M. Tanner
Aggressive preoperative use of intraaortic balloon pump in elderly patients undergoing coronary artery bypass grafting
Ann. Thorac. Surg., March 1, 1999; 67(3): 610 - 613.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. L. Minich, L. Y. Tani, G. M. Pantalos, B. L. Bolland, B. K. Knorr, and J. A. Hawkins
Neonatal piglet model of intraaortic balloon pumping: Improved efficacy using echocardiographic timing
Ann. Thorac. Surg., November 1, 1998; 66(5): 1527 - 1532.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. V. Mulay, S. Zacharias, S. D. Hansbro, R. W. Catchpole, and R. U. Nair
Should intraaortic balloon counterpulsation be continued during cardiopulmonary bypass?
J. Thorac. Cardiovasc. Surg., December 1, 1997; 114(6): 1128 - 1129.
[Full Text]


This Article
Right arrow Abstract Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
David F. Torchiana
Mortimer J. Buckley
Cary W. Akins
W. Gerald Austen
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Torchiana, D. F.
Right arrow Articles by Austen, W. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Torchiana, D. F.
Right arrow Articles by Austen, W. G.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS