|
|
||||||||
J Thorac Cardiovasc Surg 1997;114:46-52
© 1997 Mosby, Inc.
SURGERY FOR ACQUIRED HEART DISEASE |
Supported in part by a grant from Heartport, Inc., Redwood City, Calif. G.H.R. has a small equity position in Heartport, Inc.
Received for publication August 30, 1996 revisions requested Dec. 20, 1996; revisions received Feb. 3, 1997. accepted for publication Feb. 3, 1997. Address for reprints: Greg H. Ribakove, MD, New York University Medical Center, 530 First Ave., Suite 6D, New York, NY 10016.
Abstract
Objectives: Although minimally invasive coronary artery bypass grafting is now feasible, using this technique to perform anastomoses on the beating or fibrillating heart may yield poorer graft patency than the standard open techniques that use cardioplegic arrest. This study tested the feasibility and anastomotic reproducibility of minimally invasive coronary bypass using newly developed port-access coronary artery bypass technology (Heartport, Inc., Redwood City, Calif.), which allows endovascular cardiopulmonary bypass, cardiac venting, aortic occlusion, and cardioplegic arrest for internal thoracic arterycoronary artery anastomoses. Methods: Nineteen dogs had thoracoscopic takedown of either single (n = 14) or bilateral (n = 5) internal thoracic arteries followed by minimally invasive coronary bypass with cardioplegic arrest, done by means of the port-access system. The anastomotic technique was modified after the fourth animal by switching from a microscope to a 2.5 cm oval port and performing a conventional anastomosis with operative loupes. The adequacy of delivery of cardioplegic solution, ventricular decompression, and anastomotic patency was assessed. Results: The crossclamp and bypass times were 50 ± 15 minutes and 87 ± 28 minutes (mean ± standard deviation), respectively. The mean myocardial temperature after cardioplegia was 17° ± 1° C and the aortic pressure (3 ± 9 mm Hg) and pulmonary artery pressure (4 ± 1 mm Hg) were low throughout the procedure. All animals were weaned from bypass without inotropic agents. Angiograms and autopsies demonstrated successful thoracic artery takedown and anastomotic patency in 18 of 19 animals, with 100% anastomotic patency after the technique had been modified after the fourth animal. Conclusion: This study describes a reproducible technique for minimally invasive coronary bypass that allows myocardial protection, anastomotic precision, and predictable thoracic artery graft patency. Clinical trials are indicated
Although conventional coronary artery bypass grafting (CABG) is far more invasive than procedures performed in the cardiac catheterization laboratory, such as percutaneous transluminal coronary angioplasty, coronary atherectomy, or coronary stenting, the advantages of conventional CABG include excellent long-term patency rates of the internal thoracic artery (ITA) graft of 90% to 95% at 10 years and improved occurrence-free survival.
1-8 Long-term results with conventional CABG are favorable when compared with the 30% to 40% early restenosis rate after angioplasty and the 20% early restenosis rate found after coronary stenting.
1,3,9-14 Despite the long-term benefits of CABG, however, most patients with single or double vessel disease are treated initially with catheter-based intervention,
1,9,10 primarily because it is less invasive with less pain and a shorter recovery time.
Several groups have described less invasive techniques of limited-thoracotomy coronary operations that involve ITA grafting on the beating or fibrillating heart, with or without cardiopulmonary bypass (CPB).
15-19 Unfortunately, such anastomoses are predictably less precise than obtainable when operating on an arrested heart, which may neutralize the long-term benefits of using the ITA graft. Until recently, minimally invasive CABG with cardioplegic arrest was not possible because of limitations in percutaneous perfusion technology, operative exposure, suturing techniques through the closed chest, and, most important, the lack of a percutaneous myocardial protection system. Recent studies by Stevens and coworkers
20,21 at Stanford University and from our laboratory,
22 however, have demonstrated the effectiveness of closed chest cardioplegic arrest using a newly developed endovascular CPB system (EndoCPB, Heartport, Inc., Redwood City, Calif.) with an endovascular aortic occluder (Endoaortic Clamp, Heartport) and determined that minimally invasive CABG is possible with this technology. The present study was done to test in animals the reproducibility of the port-access CABG system (Heartport) in combination with thoracoscopic ITA dissection and CABG to the left anterior descending (LAD) artery and to determine if a high degree of anastomotic precision and graft patency is achievable with this approach.
Materials and methods
Nineteen heartworm-free mongrel dogs (25 to 30 kg) were supported with CPB with the use of the EndoCABG System and Endoaortic Clamp for aortic occlusion and endovascular delivery of cardioplegic solution and an endovascular pulmonary artery venting catheter (EPV, Heartport) for pulmonary artery venting. All animals were given humane care in compliance with the "Principles of Laboratory Animal Care" formulated by the National Society for Medical Research and the "Guide for the Care and Use of Laboratory Animals" prepared by the Institute of Laboratory Animal Resources and published by the National Institutes of Health (NIH Publication No. 86-23, revised 1985). Results are presented as the mean ± one standard deviation.
Surgical preparation.
All animals were initially anesthetized with a 4% solution of thiamylal (0.5 mg/kg) and maintained on metacurine iodide (0.5 mg/kg) and isoflurane after endotracheal intubation with a double-lumen tube. The animals were supported by a mechanical ventilator with oxygen, and the isoflurane was titrated to blood pressure and heart rate. The condition of all animals was monitored throughout the entire procedure with electrocardiography and measurement of carotid arterial pressure with a micromanometer (Konigsberg Instruments Inc., Pasadena, Calif.), pulmonary artery and central venous pressures with a pulmonary artery catheter (Arrow, Reading, Pa.), and oxygen saturation with an external pulse oximeter.
ITA dissection.
After induction of anesthesia, each animal was positioned in a 30-degree left lateral thoracotomy position. By means of an endotracheal tube with a bronchial blocker, the left lung was selectively deflated. A thoracoscope was placed through a 10 mm thoracic port, which was inserted into the sixth intercostal space (ICS) in the anterior axillary line. Instruments for performing the ITA dissection were placed through 10 mm thoracic ports inserted into the left third and fourth ICSs in the midaxillary line. The left ITA pedicle was dissected from its origin to its bifurcation as follows (Fig. 1, A). An incision with a thoracoscopic cautery was made longitudinally lateral to the ITA pedicle. The ITA was dissected by means of a combination of blunt and sharp dissection with the blade of the cautery. When branches were identified, small hemoclips or the electrocautery, or both, were used to divide them. The thoracoscope was moved to the third or fourth ICS ports, if necessary, for distal dissection. In five animals the right ITA was taken down in a similar fashion. Exposure was facilitated, however, by intermittent decreases in the tidal volume. The animals were systemically heparinized (100 U/kg), and, with the aid of a large endoscopic hemoclip applier, two hemoclips were placed on the most distal portions of the ITA pedicle. Before division of the ITAs from their distal attachments, an atraumatic bulldog clamp was placed thoracoscopically on the proximal portion of the artery. With the use of diathermy scissors, the ITA pedicles were divided between the large hemoclips and were withdrawn through the third or fourth ICS ports and injected with papaverine. The distal end of the pedicle was prepared outside the chest in a standard beveled fashion for anastomosis to the LAD or circumflex artery (Fig. 1, B).
|
An endovascular aortic catheter (Endoaortic Clamp, Heartport) was positioned under fluoroscopic guidance via the femoral artery into the ascending aorta with the use of a guide wire and dilator. The endovascular aortic catheter is a triple-lumen catheter with an inflatable balloon at its distal end. Positioning of the balloon was initially confirmed with instillation of a small aliquot of dilute radiopaque contrast medium (Hypaque sodium, Sanofi Winthrop Pharmaceuticals, New York, N.Y.) through the central lumen, which communicates with the tip of the catheter positioned in the aortic root. The balloon, inflated by means of the second lumen, provided an endovascular "crossclamp" by occluding the ascending aortic outflow tract (Fig. 2, A). The balloon was positioned so that it rested in the aorta without occlusion of the coronary ostia or aortic arch vessels (Fig. 2, B). Proper placement of the balloon was confirmed by the instillation of approximately 10 ml of 50% radiopaque contrast material through the central lumen into the aortic root while the balloon was inflated. The position of the endovascular aortic catheter was also reevaluated before deflation of the balloon at the end of crossclamping. Cardioplegic solution was delivered through the central lumen, which also acted as an aortic root vent. Aortic root pressure was monitored through a third separate lumen.
|
Coronary artery anastomosis.
After the institution of CPB and cardioplegic arrest, the pericardium was opened longitudinally by means of the thoracoscope and an endoscopic grasper and diathermy scissors (Fig. 1, C). Care was taken so that the phrenic nerve was not injured. In the beginning of this study the coronary artery anastomosis was performed with the aid of an operating microscope placed through a thoracic port via the anterior chest wall. Two sets of operating instrument were placed on either side of the microscope, and the anastomosis was completed through these small ports. After the initial four studies, the microscope was abandoned because it proved labor intensive and awkward. The LAD or the circumflex artery, or both, was visualized through a 20 mm port incision made in the anterior chest wall with operating loupes (Fig. 1 D). The skin, subcutaneous tissues, and ribs were separated with an 20 mm oval thoracic port (Oval Port, Heartport). The pericardium was elevated with sutures brought out through the anterior chest incision. Elevating the pericardium brought the LAD or circumflex artery into view through the anterior chest port. The left ITA, and in five animals both the left and right ITAs, was passed back into the chest and positioned over the corresponding coronary artery. The anastomosis was completed by means of standard suturing techniques with 7-0 polypropylene sutures. Using standard open operative techniques through the oval port offered the advantages of better operative exposure and visualization and better operative precision; the techniques were comfortable and less labor intensive than other methods.
During the final anastomosis, the blood temperature was warmed to above 35° C and the aorta was unclamped at completion of the anastomosis. If necessary, the heart was defibrillated with external paddles. The heart was then allowed to rewarm to 37° C, while the pulmonary artery and aortic root were still being vented. After the animal was weaned from CPB, coronary angiograms were performed by means of an ITA Angiocath catheter (Deseret Medical, Sandy, Utah) to assess patency of the ITA grafts. All angiograms were digitized and recorded on videotape.
Results
Operative data.
Eighteen of 19 animals underwent successful port-access CABG with CPB and cardioplegic arrest. One of 23 ITAs was unsuccessfully dissected and proved too short to allow performance of an anastomosis. Two adverse events occurred in our early studies. In one animal the ITA was short and there was excessive tension on the anastomosis. During a separate case, the balloon of the endovascular aortic clamp ruptured. This problem was immediately identified by several monitoring parameters: the differential pressure between the aortic root and systemic pressure was lost, the balloon pressure fell to zero, the left ventricle distended, and an increased amount of blood was noted at the LAD arteriotomy. The endovascular aortic clamp was removed, replaced, and properly positioned. The remainder of the operation continued uneventfully.
The mean operative times and monitoring data are summarized in
Table I. The mean crossclamp time was 50 ± 15 minutes, and our operative times improved with experience. By the end of the study we were able to perform bilateral ITA harvest and anastomosis in the same amount of time as was required to perform single ITA harvest and anastomosis in the earlier portion of the experimental series.
|
Myocardial temperature.
The blood temperature during CPB was cooled to 28° C and the temperature of the cardioplegic solution was 10° C. The mean left and right ventricular temperatures during CPB were 17° ± 1° C. At the conclusion of aortic crossclamping, the myocardium was rewarmed to 35° ± 1° C, and the blood temperatures were all rewarmed to above 37° C.
Angiographic and pathologic examination.
Completion angiograms were performed in 18 of the 19 cases (95%) and all grafts were widely patent (Fig. 3). All grafts were studied at autopsy and were noted to be freely patent without gross technical errors.
|
A number of early preliminary clinical experiences with minimally invasive CABG have been reported, with little follow-up data
15-19 and without angiographic studies to determine graft patency. The majority of these procedures use minithoracotomies or anterior mediastinotomies and involve operating on the beating or fibrillating heart with the aid of CPB. However, the suitability of these procedures for achieving predictable anastomotic patency and adequate myocardial protection remains uncertain. Thus the data reported here on anastomotic patency are important, because they demonstrate that by using cardioplegic arrest with the port-access CABG system and endovascular aortic clamp (Endoaortic Clamp, Heartport), the surgeon can achieve a highly reproducible ITAcoronary artery anastomosis. Whichever technique is used to preform minimally invasive CABG, the graft patency must compare favorably with the results obtainable with conventional open chest procedures and cardioplegic arrest if the technique is to be of long-term value. The present results suggest that these standards are met when using the port-access CABG system with cardioplegic arrest.
The methods described in this study maintain the fundamental principles of conventional coronary surgery, including myocardial protection and anastomotic accuracy, while fulfilling the potential to limit the pain, complications, and extended recovery associated with median sternotomy. With these methods patients can be offered a minimally invasive procedure with a greater potential for long-term success than is obtainable with catheter-based invasive cardiology procedures or surgical procedures performed on the beating heart. The system and techniques tested in this study provide the surgeon with the technology necessary to perform a meticulous coronary anastomosis on a stationary operative field, which may avoid the inaccuracies inherent with other methods.
The technical aspects of the minimally invasive procedure and use of the EndoCPB System (Heartport) became routine with training and experience. Early on we abandoned use of the operating microscope and began to use a small 2.5 cm anterior port to facilitate coronary visualization with standard operating loupes. This approach allowed a more conventional suturing technique for the coronary anastomoses. Both myocardial ischemia time and total operative time decreased as our operative experience progressed, even while we advanced to successful bilateral ITA grafts. As has been demonstrated previously, the myocardial protection provided with the EndoCPB System and Endoaortic Clamp is equivalent to that obtained with conventional open chest techniques.
22 In the current study, cardiac arrest was prompt and myocardial cooling was excellent in each zone of the heart tested, suggesting uniform delivery of cardioplegic solution to both the left and right ventricles. Likewise, the ability to vent the heart and keep the field dry was very good, because the catheter system allowed gentle suction on the aortic root, proximal to the Endoaortic Clamp, and on the pulmonary artery vent (EPV). Each animal was weaned from CPB without the need for inotropic agents and with excellent myocardial contractility.
Most significantly, postoperative angiography and postmortem autopsy studies revealed 100% anastomotic patency in each animal in which the anastomosis was completed (18 of 19 animals). This includes every animal after case 4, when the technique was modified. The anastomosis in case 3 was not completed because of a combination of inadequate takedown length on the ITA and poor visualization while we were using the 0.5 cm port and operative microscope called for in the initial protocol. This problem highlighted the need for complete ITA takedown and resulted in a protocol change to a slightly larger port with a more conventional anastomosis. Subsequently, both ITA length and anastomotic visualization were excellent in every case. These data suggest that coronary anastomoses can be performed accurately and reproducibly in a minimally invasive fashion using the port-access CABG and EndoCPB systems. Excellent late graft patency should be achievable with this method.
The limitations of minimally invasive coronary surgery may include less ability to provide treatment for complicated, multivessel coronary disease, and the procedure may not be applicable to patients requiring reoperative surgery. Nevertheless, a minimally invasive approach with cardioplegic arrest can be offered as an alternative to catheter-based therapy with the high expectation of achieving excellent graft patency. For example, a patient who previously might have been treated with coronary artery stenting for proximal LAD stenosis may now be offered a minimally invasive ITA bypass. It is our expectation that this procedure will offer patency and late results superior to those obtained either with catheter-based therapy or with surgery on the beating heart. If successful, such a procedure might result in significant cost savings, because the subsequent need for intervention may be diminished.
In summary, minimally invasive CABG with single and bilateral ITAs was successfully and reproducibly performed in a canine model by means of video-assisted ITA takedown, endovascular CPB, cardiac venting, and cardioplegic arrest through an Endoaortic Clamp (Heartport). The operative technique is based on a technologically advanced port-access CABG system that allows an accurate anastomosis to be performed on a still heart while using small ports for exposure without sternotomy. We anticipate that many of the techniques described in this article may be applicable to CABG in patients in the future. Clinical trials are now in progress.
References
This article has been cited by other articles:
![]() |
D. de Canniere, G. Wimmer-Greinecker, R. Cichon, V. Gulielmos, F. Van Praet, U. Seshadri-Kreaden, and V. Falk Feasibility, safety, and efficacy of totally endoscopic coronary artery bypass grafting: Multicenter European experience J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 710 - 716. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Dogan, K. Graubitz, T. Aybek, M. F. Khan, P. Kessler, A. Moritz, and G. Wimmer-Greinecker How safe is the port access technique in minimally invasive coronary artery bypass grafting? Ann. Thorac. Surg., November 1, 2002; 74(5): 1537 - 1543. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Shennib, S. J. Korkola, N. Bousette, and A. Giaid An automated interrupted suturing device for coronary artery bypass grafting: automated coronary anastomosis Ann. Thorac. Surg., September 1, 2000; 70(3): 1046 - 1048. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. A. Grossi, P. K. Zakow, G. Ribakove, K. Kallenbach, P. Ursomanno, C. E. Gradek, F. G. Baumann, S. B. Colvin, and A. C. Galloway Comparison of post-operative pain, stress response, and quality of life in port access vs. standard sternotomy coronary bypass patients Eur J Cardiothorac Surg, November 1, 1999; 16(Supplement_2): S39 - S42. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. A. Eagle, R. A. Guyton, R. Davidoff, G. A. Ewy, J. Fonger, T. J. Gardner, J. P. Gott, H. C. Herrmann, R. A. Marlow, W. C. Nugent, et al. ACC/AHA guidelines for coronary artery bypass graft surgery: A report of the American College of Cardiology/ American Heart Association task force on Practice Guidelines (Committee to revise the 1991 Guidelines for Coronary Artery Bypass Graft Surgery) J. Am. Coll. Cardiol., October 1, 1999; 34(4): 1262 - 1347. [Full Text] [PDF] |
||||
![]() |
E. A. Grossi, M. A. Groh, E. A. Lefrak, G. H. Ribakove, R. A. Albus, A. C. Galloway, and S. B. Colvin Results of a prospective multicenter study on port-access coronary bypass grafting Ann. Thorac. Surg., October 1, 1999; 68(4): 1475 - 1477. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. R. Stephenson Jr, C. T. Ducko, S. Sankholkar, E. M. Hoenicke, G. A. Prophet, and R. J. Damiano Jr Computer-assisted endoscopic coronary artery bypass anastomoses: a chronic animal study Ann. Thorac. Surg., September 1, 1999; 68(3): 838 - 843. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Galloway, R. J. Shemin, D. D. Glower, J. H. Boyer Jr, M. A. Groh, R. E. Kuntz, T. A. Burdon, G. H. Ribakove, B. A. Reitz, and S. B. Colvin First report of the port access international registry Ann. Thorac. Surg., January 1, 1999; 67(1): 51 - 58. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. R. Stephenson Jr, S. Sankholkar, C. T. Ducko, and R. J. Damiano Jr Robotically assisted microsurgery for endoscopic coronary artery bypass grafting Ann. Thorac. Surg., September 1, 1998; 66(3): 1064 - 1067. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |