|
|
||||||||
J Thorac Cardiovasc Surg 1997;114:507-509
© 1997 Mosby, Inc.
BRIEF COMMUNICATIONS |
Leipzig, Germany
Received for publication March 11, 1997; accepted for publication March 17, 1997. Address for reprints: Volkmar Falk, MD, Klinik für Herzchirurgie, Universität Leipzig, Herzzentrum, Russenstraße 19, 04289 Leipzig, Germany.
Intraoperative patency control of internal thoracic artery (ITA) grafts in minimally invasive direct coronary artery bypass graft (MIDCAB) operations is hampered by a limited surgical access. A new method to intraoperatively assess graft patency was developed with the use of an endoscopic thermal scanner that can be operated through a part or inserted directly through a small thoracotomy incision.
Methods.
MIDCAB operations with the ITA to graft the left anterior descending coronary artery (LAD) were performed in six male patients (aged 52 to 68 years) with isolated disease of the LAD. Four patients had a history of single or multiple percutaneous angioplasties. Left ventricular function was within normal limits in all patients (ejection fraction > 50%). Patients were anesthetized and placed in a supine position. Through a small anterolateral thoracotomy (6 to 8 cm) in the fourth intercostal space, the ITA was harvested. Two patients underwent cardiopulmonary bypass with endoaortic clamping and cardioplegic arrest by means of the Port-Access System (Heartport, Inc., Redwood City, Calif.).
1 In the other four patients we operated on the beating heart with temporary LAD occlusion and local ventricular wall immobilization using the CTS system (Cardio Thoracic Systems, Cupertino, Calif.).
2 After completion of the distal anastomosis and before release of the vascular clamp, an endoscopic thermal scanner (Infracam, Inframetrics, North Billerica, Mass.) was introduced through the thoracotomy incision. The scanner based on a platinum silicon (PtSi) focal plane array detector (256 x256 elements) operates at a wavelength of 3.4 to 5.0 µm (mid-infrared spectrum) with a spatial resolution of 0.6 mrad. A 30 cm endoscope with an indium antimony (InSb) lens allows the scanner to operate through a 10 mm port. After placement of the endoscope above the surface of the heart and after local topical cooling, the vascular clamp on the ITA graft was released. The thermal gradient generated by the inflow of warm blood through the graft delineated the anastomosis and the distal vascular bed. The resulting heat picture was transformed online into an angiographic picture on a conventional video screen. In all patients graft flow was also confirmed by transit-time Doppler-flow measurements (Transonic Systems Inc., Ithaca, N.Y.). All patients underwent a second angiogram before discharge (postoperative days 3 to 6).
Results.
All operations were uneventful. Median ITA takedown was 33 minutes and median operation time was 117 minutes. Placement of the endoscope was performed through the thoracotomy incision in all cases. Fig. 1 shows a typical intraoperative thermal angiogram of an ITA graft to the LAD that was performed on the beating heart. Before release of the vascular clamp, the surface of the heart shows a homogeneous temperature distribution. The forceps indicates the site of anastomosis(Fig. 1, a). After release of the vascular clamp, thermal coronary angiography shows immediate antegrade perfusion of the LAD, as well as retrograde filling of a first diagonal branch, documenting graft and anastomotic patency. Thermal coronary angiography revealed patency of the ITA graft in all six patients. Median graft flow as measured by transit-time Doppler ultrasonography was 46 ml/min (32 to 70 ml/min). No patient showed signs of myocardial ischemia in the perioperative period (normal electrocardiogram, no significant elevation of cardiac enzymes). Median intubation time was 10 hours. ICU stay and time of hospitalization were 1 day and 8 days, respectively. On postoperative angiography, all ITA grafts were patent and showed good runoff.
|
Control of intraoperative graft patency is important to avoid the catastrophic consequences that can be caused by ITA graft failure. Especially in MIDCAB operations, in which grafting is technically more demanding and access to the heart is limited, there is a need for intraoperative quality control. Thermal coronary angiography has been developed for intraoperative noninvasive testing of anastomotic patency in conventional coronary artery bypass graft operations.
3 Thermal coronary angiography has been shown to correctly identify anastomotic failures during the operation and has led to graft revision in routine coronary artery operations.
4,5 The method not only provides a noninvasive angiographic picture of the graft and the attached coronary artery but also reflects graft flow by the velocity of the induced temperature changes. Although conventional thermal imaging has been used to document ITA graft flow to the LAD in a MIDCAB procedure, the obtained images were of poor quality and did not visualize the vascular bed completely.
6 Because of the limited surgical access, ceiling or tripod-mounted thermal imaging systems cannot be positioned accurately. The endoscopic thermal scanner that can be directly placed through the thoracotomy incision or through a separate port is therefore far superior. The system allows for optimal imaging in the region of interest. After brief topical cooling, heat contrast was sufficient to demonstrate graft flow even on the beating heart. Intraoperative flow measurement, as well as postoperative angiography, confirmed the results of thermal coronary angiography.
As a noninvasive method, thermal coronary angiography does not require any manipulation of the graft. As again demonstrated in this series, intraoperative flow measurements using transit-time Doppler ultrasonography are awkward in MIDCAB procedures. Because of the limited access, positioning of the flow probe is difficult and also requires skeletonizing of the pedicle, which can be potentially harmful. Furthermore, the Doppler method only provides a flow curve, whereas thermal coronary angiography visualizes the complete vasculature in an angiographic fashion. On the beating heart, generation of a temperature gradient by short-term local topical cooling (sponge soaked in saline solution) immediately before thermal imaging improves image quality. A digital substraction method to further enhance contrast is currently under investigation. If applied during a closed chest technique with cardioplegic cardiac arrest (Port-Access method), endoscopic thermal coronary angiography provides even higher quality images. In conclusion, endoscopic thermal coronary angiography is a useful adjunct in MIDCAB surgery. It allows for a no-touch intraoperative graft patency control.
References
This article has been cited by other articles:
![]() |
J. A. Wolfe The coronary artery bypass conduit: II. Assessment of the quality of the distal anastomosis Ann. Thorac. Surg., December 1, 2001; 72(6): S2253 - 2258. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. McLoitghlin JR Complications of Minimally Invasive Cardiac Surgical Procedures Seminars in Cardiothoracic and Vascular Anesthesia, July 1, 1999; 3(2): 136 - 142. [Abstract] [PDF] |
||||
![]() |
F. W. Mohr, V. Falk, A. Diegeler, and R. Autschback COMPUTER-ENHANCED CORONARY ARTERY BYPASS SURGERY J. Thorac. Cardiovasc. Surg., June 1, 1999; 117(6): 1212 - 1213. [Full Text] [PDF] |
||||
![]() |
A. Diegeler, M. Matin, S. Kayser, Ch. Binner, R. Autschbach, R. Battellini, H. Krankenberg, and F.W. Mohr Angiographic results after minimally invasive coronary bypass grafting using the minimally invasive direct coronary bypass grafting (MIDCAB) approach Eur. J. Cardiothorac. Surg., May 1, 1999; 15(5): 680 - 684. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Cremer, A. Mugge, T. Wittwer, A. Boening, P. Kim, T. Kofidis, H. Drexler, and A. Haverich Early angiographic results after revascularization by minimally invasive direct coronary artery bypass (MIDCAB) Eur. J. Cardiothorac. Surg., April 1, 1999; 15(4): 383 - 388. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Goldstein, R. D. Safian, D. Aliabadi, W. W. O'Neill, F. L. Shannon, J. Bassett, and M. Sakwa Intraoperative angiography to assess graft patency after minimally invasive coronary bypass Ann. Thorac. Surg., December 1, 1998; 66(6): 1978 - 1982. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Diegeler, V Falk, K Krahling, M Matin, T. Walther, R Autschbach, R Battelini, and F.W Mohr Less-invasive coronary artery bypass grafting: different techniques and approaches Eur. J. Cardiothorac. Surg., October 1, 1998; 14(suppl_1): S13 - S19. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Diegeler, V. Falk, M. Matin, R. Battellini, T. Walther, R. Autschbach, and F. W. Mohr Minimally invasive coronary artery bypass grafting without cardiopulmonary bypass: early experience and follow-up Ann. Thorac. Surg., September 1, 1998; 66(3): 1022 - 1025. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Diegeler, V Falk, M Matin, W Wirthle, T. Walther, R Autschbach, and F W Mohr Minimally invasive coronary artery bypass grafting: experience with the CTS system approach Perfusion, July 1, 1998; 13(4): 237 - 242. [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |