JTCS Speed Up Your Browser
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Volker Kühlkamp
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mewis, C.
Right arrow Articles by Seipel, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mewis, C.
Right arrow Articles by Seipel, L.

J Thorac Cardiovasc Surg 1997;114:1121-1122
© 1997 Mosby, Inc.


BRIEF COMMUNICATIONS

LEAD FAILURE CAUSED BY TWIDDLER'S SYNDROME IN SUBPECTORALLY IMPLANTED UNIPOLAR SINGLE-LEAD CARDIOVERTER-DEFIBRILLATORS

Christian Mewis , MDa, Volker Kühlkamp , MDa, Volker Dörnberger , MDa, Koroush Kalighi , MDb, Ludger Seipel , MDa


Tübingen, Germany

Received for publication May 6, 1997 Accepted for publication June 24, 1997 Address for reprints: Christian Mewis, MD Department of Cardiology, University Hospital Tübingen, Otfried-Müller-Str. 10, 72076 Tübingen, Germany.

Twiddler's syndrome, first described in 1968 by Bayless, Beanlands, and BairdGo 1 as a rare complication in patients with pacemakers, is characterized by dislodgment of transvenous leads by the twisting of pulse generators in the subcutaneous pocket, resulting in lead malfunction. As might be expected, similar complications could arise in the case of subpectorally placed implantable cardioverter-defibrillators (ICDs). Especially in unipolar defibrillation systems, which use the housing of the ICD itself as the second active defibrillation electrode, device migration could have a fatal influence on the defibrillation field. We report two cases of this rare complication.

PATIENT 1

A 66-year-old male patient (body index 24.5 kg/m2) with severe coronary artery disease and ventricular tachycardia was referred to our clinic. Bypass surgery was performed. Three weeks later, after full recovery, programmed ventricular stimulation induced sustained monomorphic ventricular tachycardia. An ICD (Jewel Plus 7220 active can, 80 cm2, 129 gm; Medtronic, Inc., Minneapolis, Minn.) was implanted with a unipolar single lead (Transvene 6936, length 65 cm; Medtronic, Inc.) positioned in the right ventricle because drug testing failed to suppress the ventricular tachycardia.

A skin incision was performed parallel and approximately 2 cm inferior to the left clavicle. A subpectoral pocket was created by bluntly separating the transverse muscle fibers of the pectoralis major muscle that insert in the clavicle and sternum. Thereafter, the patient stayed well without any shock deliveries for 3 months. At the routine 3-month visit, an exit block of the pacing lead with an increased impedance to 1366 {Omega} was noted. The patient did not report any device manipulation, local discomfort, or excessive device mobility. Surgical exploration of the ICD pocket revealed a ninefold twirling of the pulse generator around its longitudinal axis (Fig. 1), causing a tight twisting of the electrode near the aggregate. The intraoperative defibrillation threshold of 9 J was unchanged from the initial one. The pulse generator was disconnected and removed, and the lead was untwisted and replaced with a new lead. The generator was reimplanted in a pocket more medial than the former one and also anchored at the underlying muscle fascia. Twelve months later, chest radiography showed a stable generator position.



View larger version (119K):
[in this window]
[in a new window]
 
Fig. 1. The intraoperative situs of patient 1 revealed the twisted lead near the aggregate. On further exploration, the pulse generator was seen to have twirled nine times around its longitudinal axis.

 
PATIENT 2

In a 59-year-old obese male patient (body index 33.5 kg/m2) with aborted cardiac arrest and dilated cardiomyopathy, a unipolar ICD (Ventak Mini 1742 HC, 125 gm, volume 68 cm2; Cardiac Pacemakers, Inc., St. Paul) was implanted in left subpectoral position with a tripolar silicone lead (Endotak CR 0125, length 70 cm; Cardiac Pacemakers, Inc.) in the apex of the right ventricle. The implantation technique was performed as described for patient 1. Three months later, patient 2 had a routine visit to our outpatient clinic. In the meantime, he had lost approximately 8 kg weight. The test of the ICD revealed a rise in the pacing threshold of 5 V, with impulse width of 0.6 msec. The remaining parameters, including the defibrillation threshold, were unchanged from the values of the predischarge test. Surgical exploration showed a laterally dislocated pulse generator that was rotated 22 times around its longitudinal axis in a loose, subpectoral pocket. The lead was disconnected, untwisted, and removed. The pocket was plicated, and the generator was anchored with sutures at the underlying muscle fascia to prevent further generator movements. A new lead was inserted. The patient was discharged, and follow-up 6 months later showed a stable function and position of the device.

Discussion

The twiddler's syndrome may remain asymptomatic as in these cases, but lead fracture or dislodgement in an ICD can cause inadequate shock deliveries or even sudden cardiac death.Go 2 This syndrome has been described in some patients with abdominal ICDsGo 3 and 5 weeks after implantation in one patient with an ICD in subpectoral position who palpated his pulse generator for hours at time because of moderate discomfort.Go 4 To our knowledge, these two cases of twiddler's syndrome are the first reported with unipolar devices. In this type of ICD, the defibrillation field depends on a stable position of the shell. The defibrillation threshold thus could increase significantly with device migration. In our cases, however, the defibrillation threshold remained stable. This may be because the devices migrated mainly laterally and not in the longitudinal axis, influencing the defibrillation field less. In both cases, the implantation technique was as generally recommended.Go 5 However, these two patients may have had predisposing factors for increased device mobility. Patient 1's long period of hospitalization caused atrophy of both pectoralis muscles, which may have contributed to an increased generator mobility. In the case of patient 2, obesity was a risk factor for device mobility. Furthermore, this patient lost significant weight after ICD implantation, which may have caused a loose generator pocket. In both cases, suturing of the generator to the underlying muscle fascia led to sufficient device stability.

Increasing numbers of this complication of subpectorally implanted ICDs must be expected, because the devices are still larger and heavier than modern pacemakers. The use of the Parsonnet pouch, as suggested by Furman,Go 6 may be effective in preventing twiddler's syndrome in patients with risk factors such as obesity or pectoral atrophy.

Footnotes

From the Departments of CardiologyaCardiothoracic Surgery,b University Hospital Tübingen, Tübingen, Germany. Back

References

  1. Bayless CE, Beanlands DS, Baird RJ. The pacemaker-twiddler's syndrome: a new complication of implantable transvenous pacemakers. Can Med Assoc J 1968;99:371-3. [Medline]
  2. Avitall B, Stormo A, Barragry T, Axtel K, Hare J. Sudden cardiac death: twiddler's syndrome with an implantable cardioverter defibrillator. Am Heart J 1994;128:833-6. [Medline]
  3. Robinson LA, Windle JR. Defibrillator twiddler's syndrome. Ann Thorac Surg 1994;58:247-9. [Abstract]
  4. Crossley GH, Gayle DD, Bailey JR, Haisty WK, Simmons TW, Fitzgerald DM. Defibrillator twiddler's syndrome causing device failure in a subpectoral transvenous system. PACE Pacing Clin Electrophysiol 1996;19:376-7. [Medline]
  5. Foster AH. Technique for implantation of cardioverter defibrillators in the subpectoral position. Ann Thorac Surg 1995;59:764-7. [Abstract/Free Full Text]
  6. Furman S. Defibrillator twiddler's syndrome. Ann Thorac Surg 1995;59:544-6.[Free Full Text]




This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Volker Kühlkamp
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mewis, C.
Right arrow Articles by Seipel, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mewis, C.
Right arrow Articles by Seipel, L.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS