J Thorac Cardiovasc Surg 1998;115:528-535
© 1998 Mosby, Inc.
SURGERY FOR CONGENITAL HEART DISEASE |
Supported in part by a grant from the Duke Children's Hospital Miracle Network Telethon. LiquiVent was supplied by Alliance Pharmaceutical Corp. (San Diego, Calif.) and Hoechst Marion Roussel (Bridgewater, N.J.).
Read at the Seventy-seventh Annual Meeting of The American Association for Thoracic Surgery, Washington, D.C., May 4-7, 1997.
Received for publication May 5, 1997; revisions requested June 30, 1997; revisions received Oct. 23, 1997; accepted for publication Oct. 29, 1997. Address for reprints: Ira M. Cheifetz, MD, Duke University Medical Center, Box 3046, Durham, NC 27710.
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
Organ-protective strategies have traditionally been targeted at myocardial and cerebral function. With improvements in myocardial and cerebral protection, operative techniques, and perioperative care, early neonatal or infant repair is recommended for most repairable congenital heart lesions.
9,10 Long-term results are encouraging; however, without a strategy for lung protection, the pulmonary vasculature and parenchyma may suffer severe injury after CPB, resulting in increased morbidity and mortality, abnormal convalescence, and prolonged ventilatory requirements. Many neonates and infants have a prolonged intensive care unit (ICU) admission because of this postoperative respiratory insufficiency.
1,9 The main determination of the length of stay of infants and children in the ICU is the need for mechanical ventilation.
These pathophysiologic changes that occur in the pulmonary system of neonates and pediatric patients after exposure to CPB also have an impact on the cardiovascular system.
4-6,8,11,12 The effects of respiratory insufficiency and mechanical ventilation on cardiorespiratory interactions are well described and are of increasing importance after CPB. The overall cardiorespiratory adverse effects of CPB may be significantly reduced if the initial lung injury can be minimized.
The mechanism of the pulmonary vascular and parenchymal injuries is multifactorial. CPB with hypothermia may result in a variety of injuries, including those related to oxygenation/reoxygenation, hypoxemia, ischemia, and reperfusion. Exposure of blood to nonendothelialized surfaces activates the immune system, including the complement cascade. These injuries often result in decreased pulmonary compliance, increased PVR, and, potentially, decreased cardiac output. These abnormalities of cardiorespiratory function may result in decreased oxygen delivery.
Liquid ventilation with perflubron (LiquiVent; Alliance Pharmaceutical Corp., San Diego, Calif.) may be beneficial in treating acute lung injury.
13-21 The beneficial effects of liquid ventilation include its antiinflammatory properties, alveolar distending properties, surfactant-like function, and oxygen delivery capability. During CPB, the lungs are bypassed and are usually not ventilated. Thus liquid ventilation may provide an opportunity to access and to protect the lungs during CPB. As a result, administering perflubron to the lungs during CPB might benefit the patient by modifying the adverse pulmonary response to bypass.
At present, no clinical data are available on the use of liquid ventilation in association with CPB for cardiac operations. Thus the focus of our study was to define the role of liquid ventilation on cardiac and respiratory function after CPB. We hypothesized that liquid ventilation initiated before CPB would improve post-CPB pulmonary function and cardiac output in a neonatal model of CPB. The beneficial effects of liquid ventilation include exerting effects similar to surfactant, functioning as a liquid positive end-expiratory pressure to reduce atelectasis, providing antiinflammatory properties, and acting as an oxygen carrier at the alveolar level. The physiologic benefits of liquid ventilation would include improved pulmonary compliance, decreased regional hypoxic pulmonary vasoconstriction, improved cardiac output, and increased oxygen delivery.
| Materials and methods |
|---|
|
|
|---|
Anesthesia was maintained with a continuous infusion of fentanyl. Intermittent boluses of pancuronium bromide were administered for neuromuscular blockade. A femoral artery catheter was placed for systemic blood pressure monitoring and blood sampling. After a median sternotomy, the pericardium was incised, and a pericardial cradle created. An ultrasonic transit-time flow probe (Transonic Systems, Inc., Ithaca, N.Y.) was placed around the pulmonary artery at the level of the right ventricular (RV) outflow tract. Micromanometer pressure catheters (Millar Instruments, Inc., Houston, Tex.) were placed in the right ventricle and in the pulmonary artery at the level of the ultrasonic flow probe.
CPB and liquid ventilation
(Fig. 1). The animals randomized to the control group were ventilated conventionally at the settings described. The animals randomized to the intervention group received liquid ventilation before CPB. Perflubron was administered to approximate the functional residual capacity as determined by the presence of perflubron in the endotracheal tube at a positive end-expiratory pressure of 0 cm H2O. The perflubron dose was limited to a maximum of 20 ml/kg. The perflubron was administered over 15 to 20 minutes by use of standard technique through the side-port of an adapter on the endotracheal tube.
13,15-19 Perflubron administration was completed before cannulation for CPB. No further doses of perflubron were administered.
|
Data collection.
Data were collected for the control group at baseline before bypass. Baseline data for the liquid ventilation group were obtained at baseline before both CPB and the administration of perflubron. Post-CPB data were collected for both groups at 30, 60, and 90 minutes after separation from CPB.
Measurements.
The determination of the pulmonary parenchymal injury consisted of evaluating respiratory mechanics and gas exchange. All respiratory mechanics measurements were obtained using a pneumotachometer and a stand-alone respiratory mechanics monitor (Ventrak, Novametrix Medical Systems; Wallingford, Conn.). Measurements included peak inspiratory pressure, plateau pressure, mean airway pressure, dynamic compliance, and total airways resistance. Static compliance was calculated as delivered tidal volume divided by the difference between the plateau pressure and the positive end-expiratory pressure.
Cardiac output was determined by the ultrasonic pulmonary artery flow probe. Oxygen delivery was determined by the standard calculation of cardiac output x (1.34 x hemoglobin x oxygen saturation + 0.003 x Pao2).
In addition to the standard measures of pulmonary artery pressure and pulmonary blood flow, the pulmonary vascular injury was assessed by pulmonary input resistance and pulmonary characteristic impedance. To calculate the impedance spectrum, the data sets were individually separated into cardiac cycles and waveform averaged.
22 Characteristic impedance, which is derived from the impedance spectrum, describes the physical properties of the pulmonary vascular bed and is inversely related to its compliance and cross-sectional area.
22-24 Characteristic impedance describes the resistance of the larger, proximal pulmonary vessels. In contrast, pulmonary input resistance (mean pulmonary artery pressure/mean pulmonary blood flow) evaluates the entire pulmonary vasculature (large proximal vessels and small distal vessels).
22-24 The measurements of both pulmonary characteristic impedance and input resistance allow for a comprehensive evaluation of the reactivity of the pulmonary vasculature.
Statistical analysis.
The pre-CPB baseline data for each group were compared with the data 30 minutes after CPB by paired t test. The data at baseline were compared between the two groups by unpaired t test to ensure appropriate randomization. The post-CPB data (30, 60, and 90 minutes) were compared between the two groups using a linear regression model of analysis of variance with repeated measures. All data are indicated as mean ± standard error of the mean.
| Results |
|---|
|
|
|---|
|
|
|
The post-CPB data (30, 60, and 90 minutes) were compared between the two groups using a linear regression model of analysis of variance with repeated measures at 30, 60, and 90 minutes after CPB to characterize the degree of lung protection offered by the liquid ventilation. At 30 minutes after separation from CPB, animals receiving liquid ventilation had increased cardiac output (54%), increased oxygen delivery (50%), decreased input pulmonary resistance (52%), decreased characteristic impedance (32%), and improved static compliance (26%) compared with control animals not receiving liquid ventilation. These statistically and clinically significant differences were maintained throughout the 90-minute data acquisition period, although to a lesser degree (Tables I
and II
).
At baseline and at 30, 60, and 90 minutes after separation from CPB, no statistically or clinically significant differences were observed in pH, Paco2, systemic pressures, mean airway pressure, or total airways resistance (Tables II
and III
). Oxygenation was higher after CPB in the control group but not to a clinically significant degree. At baseline and at 30 minutes after CPB, peak inspiratory pressure and dynamic compliance were similar. However, at 60 and 90 minutes after CPB, peak inspiratory pressure trended lower and dynamic compliance trended higher in the group treated with liquid ventilation (Table II
).
| Discussion |
|---|
|
|
|---|
After operation for congenital heart disease, pulmonary insufficiency can significantly alter cardiovascular performance. These changes may be significant and cause abnormal ventricular function in neonates and young children because the required repair can disrupt the normal myocardial architecture, resulting in direct myocardial injury, whereas CPB contributes to myocardial edema and changes in loading conditions.
9,10 In the postoperative period, the right ventricle may be unable to increase its work load when presented with increased RV afterload resulting from pulmonary vasoconstriction. In addition, a deterioration in respiratory parenchymal function after bypass may result in the need for increased airway pressures. This increased ventilatory support may further compromise RV function by limiting RV preload and/or further increasing RV afterload. Decreased RV output would decrease left ventricular preload and therefore decrease systemic cardiac output.
Mechanisms of CPB-induced lung injury.
The pathophysiology of the CPB-induced pulmonary injury is not well understood. This pulmonary injury is most probably multifactorial with causes including oxygenation/reoxygenation, hypoxemia, ischemia, reperfusion, and surfactant dysfunction.
5,11,12,26-29A systemic inflammatory response occurs during CPB as blood contacts nonphysiologic surfaces.
5,11,26-28 This inflammatory response is characterized by complement activation, leukocyte degranulation, neutrophil activation, increased capillary permeability, and membrane injury.
5,11,26-28 Complement activation may compromise lung function by altering airways resistance and pulmonary compliance.
5 Surfactant function has been shown to decrease with CPB in children.
29 Surfactant dysfunction correlates with increased atelectasis and decreased pulmonary compliance. Hypothermia and nonpulsatile perfusion may induce pulmonary injury by altering the patterns of pulmonary blood flow.
4,5,11
Sequelae of the CPB-induced pulmonary injury.
Management of the pulmonary insufficiency during the postoperative period requires an understanding of the physiologic consequences of CPB. Capillary leak with alveolar edema resulting from pulmonary endothelial cell injury reduces pulmonary compliance and functional residual capacity and increases the alveolar-arterial oxygen gradient
7,8,30 In addition, atelectasis causes ventilation-perfusion mismatch, the development of intrapulmonary shunting, and pulmonary vasoconstriction that manifests clinically as increased PVR, increased pulmonary artery pressure, decreased arterial saturation, and reduced arterial oxygen content.
2,3,7,31 Therapy for pediatric patients with pulmonary insufficiency is directed at reducing and/or preventing endothelial cell injury and alveolar collapse.
Our study data confirm these bypass-associated vascular and parenchymal pulmonary injuries. The increases in input pulmonary resistance and characteristic impedance were associated with a decrease in cardiac output and oxygen delivery. Decreased static compliance supports the presence of the parenchymal injury.
Liquid ventilation.
Liquid ventilation has the potential to be beneficial in both clinical and animal evaluations of acute lung injury.
13,21 In liquid ventilation perflubron is instilled into the injured lungs at a volume that approximates the functional residual capacity of the lungs.
13 The patient is then conventionally ventilated. Perflubron may have antiinflammatory properties and may eliminate the air-fluid interface, decreasing surface tension and providing a surfactant-like effect. In addition, the presence of liquid in the alveoli maintains alveolar patency by exerting a continuous alveolar distending pressure during the expiratory phase ("liquid positive end-expiratory pressure"). These effects of perflubron would decrease alveolar atelectasis and maintain the functional residual capacity of the lungs.
32 Thus liquid ventilation should improve pulmonary compliance while reducing PVR and improving cardiac output and oxygen delivery.
13-21
In our study, the use of liquid ventilation improved post-bypass pulmonary function. Therefore the degree of lung injury seen after CPB may have been less in the animals receiving perflubron therapy than in the control animals. After CPB, the animals receiving liquid ventilation did have a modest increase in input pulmonary resistance and decrease in static compliance. However, a significant change in cardiac output, oxygen delivery, or characteristic impedance was not observed. When comparing the liquid ventilation group with the control group, a significant reduction in pulmonary parenchymal and vascular injury was seen at 30, 60, and 90 minutes after CPB. These data suggest that liquid ventilation may have helped to protect the lungs from the deleterious effects of CPB in this neonatal model.
An improvement in static compliance implies the ability to deliver the same tidal volume at a lower airway pressure. Postoperatively, this decrease in airway pressure should correlate with a decreased risk for barotrauma, potentially a decreased length of mechanical ventilation, and an improvement in cardiorespiratory interactions.
Although the exact mechanisms of the pulmonary vascular protection offered by liquid ventilation remain uncertain, the relationship of various physiologic changes can be hypothesized. Some combination of the beneficial effects of liquid ventilation, including its antiinflammatory properties, alveolar distending properties, surfactant-like function, and oxygen delivery capability, resulted in a decrease in pulmonary reactivity. This improvement was demonstrated by a decrease in both input resistance and characteristic impedance. Presumably, this decrease in the afterload to the right ventricle resulted in improved RV function and, subsequently, increased global cardiac output. The increased cardiac output resulted in a clinically significant improvement in oxygen delivery.
Potential adverse effects.
Liquid ventilation is not without theoretical risks.
13-19,33 The presence of perflubron in the alveolar space may result in adverse effects on cardiorespiratory function. As a liquid, perflubron is an excellent carrier of oxygen; however, it is not as efficient as gas in transporting oxygen. When perflubron is placed in the alveoli, the maximum alveolar-arterial oxygen tension obtainable is 350 to 400 mm Hg versus 713 mm Hg for a gas at standard temperature and pressure.
32 This results in an obligatory alveolar-arterial oxygen gradient when perflubron is instilled into normal lungs. Thus in normal lungs this has the potential to decrease the arterial oxygen content and lead to hypoxemia. However, in the early operative period, ventilating a patient with normal lung function and without a right-to-left shunt with an Fio2 of 1.0 would result in a arterial oxygen tension of 300 to 400 mm Hg, and this should not pose any risk to the patient. If the patient does have underlying lung disease, previous animal studies have demonstrated that when lung injury is present perflubron increases the systemic arterial oxygen content compared with conventional ventilation at similar settings.
13-19,33 In situations in which the concern over possible hypoxia exists, the perflubron may be administered immediately after cannulation for bypass.
Theoretically, perflubron may alter cardiorespiratory performance by altering intrathoracic pressure. When perflubron is instilled into the lungs, the weight of the liquid (1.92 gm/ml) may increase intrathoracic pressure.
32 This increase in intrathoracic pressure may limit preload and decrease cardiac output by decreasing RV filling. Our data do not support this theoretical risk. In addition, perflubron has the potential to expand the alveolus and compress the pulmonary vasculature. Potentially, this may lead to an increase in pulmonary artery resistance and a worsening of RV function if RV afterload is significantly increased. The results from this study indicate that PVR and cardiac output are, in fact, improved with perflubron therapy. Therefore the theoretical concern that perflubron may adversely affect cardiorespiratory performance does not seem valid under the conditions of this study.
Limitations of the study.
Perflubron has been shown to evaporate over time.
13,32 Therefore the initial dose of perflubron may be inadequate to maintain the improvement in lung function hypothesized. Supplemental doses of perflubron may be needed; however, the effects of maintaining a constant volume of perflubron in the lungs by providing additional dosing was not the intent of this study. Additionally, this study was an acute study and did not answer the question of the effects of liquid ventilation on the length of mechanical ventilation.
By administering the perflubron before CPB, it cannot be determined from our data whether liquid ventilation prevented the pulmonary lung injury or treated the lung injury as it was occurring. In either case, the net result was improved pulmonary function with liquid ventilation after bypass. Future experiments with perflubron dosing before and after bypass can be performed to determine whether liquid ventilation prevents or treats the lung injury associated with CPB and to identify the exact mechanisms involved.
Our evaluation of liquid ventilation immediately after bypass represents a time period of increased vulnerability for the neonate because the cardiorespiratory abnormalities that develop are at their peak. Data obtained during this "high-risk" phase can be extrapolated to clinical practice and are essential to design future clinical and laboratory investigations. The long-term effects of liquid ventilation may be a subject of future research.
We have demonstrated that the lung protection strategy of liquid ventilation improved pulmonary vascular and parenchymal function and cardiac output in a neonatal model of CPB. The morbidity associated with CPB may be significantly reduced if the adverse pulmonary sequelae of CPB can be diminished. Liquid ventilation may become an important technique for protecting the lungs from the deleterious effects of CPB.
| Appendix: Discussion |
|---|
|
|
|---|
The second question centers around the lung mechanics that you observed in the treated group versus the untreated group. Because the static compliance was better in the treated animals but the Pco2 was the same in each of the two groups, it seems that the ventilatory management would have to have been altered to keep those same parameters. I wonder whether you could comment on how you think the compliance changes affected the pulmonary hemodynamic parameters that you measured. Along those same lines, clearly some relationship exists between PVR parameters and lung volumes, and traditionally it has been taught that lowest PVR occurs at functional residual capacity. So I wonder whether you might tell us if you measured any lung volume parameters, such as functional residual capacity, in your treated and untreated animals and if you have any idea where you were operating in the range between residual volume and total lung capacity.
The last question that I have relates to the hypothesis that somehow pulmonary vascular endothelial function is preserved. I wonder whether you have done any studies to demonstrate any differences in pulmonary endothelial function or whether you have any evidence that the perflubron is actually absorbed intravascularly and therefore would be a way that pulmonary vascular endothelial protection might be present.
Dr. Cheifetz. Thank you, Dr. Mayer, for reviewing the manuscript and providing some very thoughtful questions.
In terms of the RV filling pressure, we have data that demonstrate that RV end-diastolic pressures were maintained constant throughout the protocol. This was our best approximation of preload. In addition, the volume management of the animals was the same for both groups. So to the best that we can determine from our data, the preload was identical between the two groups. Therefore our assumption is that the improvement in cardiac output is a result of the decrease in afterload in the liquid ventilation group compared with the control group.
Discussing lung mechanics in more detail, Pco2 was maintained identically between the two groups by maintaining the same tidal volume between the control group and the liquid ventilation group. The improvement in static compliance occurs because the plateau pressure is actually lower in the liquid-treated animals for the same tidal volume. So, we see an improvement in lung mechanics while maintaining the same tidal volume and, therefore, the same Pco2.
In terms of the relationship between the plateau pressure, which is decreased in the liquid-treated animals compared with the control animals, and PVR, we have not done any specific correlations between these values. However, the changes in plateau pressures are small and probably do not relate to a large degree to the changes in PVR.
Discussing lung volumes in more detail, in the liquid-treated animals the perflubron was dosed to functional residual capacity using standard technique that has been performed in both clinical and in animal studies. Our best assumption on the basis of prior studies, is that the liquid animals were maintained at functional residual capacity. In the control animals we did not perform any determinations of lung volume. I do not know whether these animals were functioning at or below functional residual capacity. However, for the purposes of this study we were attempting to determine the difference between liquid and control animals knowing that the liquid-treated animals would probably be functioning at slightly higher lung volumes.
Last, in terms of the endothelial function, in this first pilot study we did not specifically test any markers of endothelial cell injury. However, this topic is a central component to our follow-up studies. We are attempting to determine how much of an antiinflammatory effect the perflubron does have in this animal model and how much improvement we can see, simply because perflubron has some antiinflammatory properties. There is minimal absorption of perflubron intravascularly and that exact amount is still uncertain in this animal model.
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
L. Jiang, Q. Wang, Y. Liu, M. Du, X. Shen, X. Guo, and S. Wu Total liquid ventilation reduces lung injury in piglets after cardiopulmonary bypass. Ann. Thorac. Surg., July 1, 2006; 82(1): 124 - 130. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |