JTCS Speed Up Your Browser
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Michael Poullis
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Poullis, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Poullis, M.

J Thorac Cardiovasc Surg 1999;117:827-828
© 1999 Mosby, Inc.


BRIEF COMMUNICATIONS

FOURIER ANALYSIS OF THE INTRA-AORTIC BALLOON PUMP

Michael Poullis, Bsc(Hons), MBBS, FRCS(Eng), London, United Kingdom

From the Department of Cardiothoracic Surgery, National Heart and Lung Institute, Imperial College of Science, Technology and Medicine, Hammersmith Hospital, London, United Kingdom.

Received for publication Sept 15, 1998. Accepted for publication Nov 5, 1998. In patients with an intra-aortic balloon pump (IABP), maximum blood pressure augmentation occurs with the balloon set to 1:1 mode. However, there is a subset of patients in whom better blood pressure augmentation is obtained when the balloon is set to 1:2 or even 1:3.

Systemic vascular resistance is a commonly used term, but it is misleading because it implies that it is a constant, regardless of heart rate. In practice this is not true, hence the adoption of the term impedance. It has been shown that, when the heart and vasculature are matched for impedance, maximum systolic blood pressure results.Go Go 1,2 The impedance of the vasculature is dependent not just on the heart rate but also on the vascular compliance and the viscosity of the blood.

The arterial waveforms of patients are conventionally viewed with time on the horizontal axis, the time domain. If the arterial waveforms are viewed with the frequency components that make up the arterial waveforms on the horizontal axis, then this is called the frequency domain.

Frequency domain analysis takes into account systemic vascular impedance, blood viscosity, vascular compliance, blood volume, and heart rate because these determine the shape of the arterial pressure waveform. The technique of converting an arterial waveform in the time domain to 1 in the frequency domain is called Fourier analysis, the mathematics of which is beyond the scope of this article.

Matching the heart rate to the fundamental frequencies obtained from frequency domain analysis of the arterial waveforms would have major benefits for patients because of the impedance matching that would result.Go 3

The typical intra-arterial tracing from a patient with a balloon pump inserted that is operating in 1:1, 1:2, and 1:3 are shown in Fig. 1, A, C, and E, respectively (time domain). Fast Fourier analysis (Syntrillium Software Corporation, Phoenix, Ariz) was used to convert the time domain data into the frequency domain.



View larger version (73K):
[in this window]
[in a new window]
 
Fig 1. The intra-atrial tracings from a patient with a balloon pump inserted that is operating in 1:1 mode (A), 1:2 mode (C), and 1:3 mode (E) are shown (time domain analysis). Fast Fourier transforms of IABP intra-arterial trace for 1:1 mode (B), 1:2 mode (D), and 1:3 mode (F) are shown (frequency domain analysis). Vertical scale is in decibels. The sharp upward spikes represent the component frequencies of the arterial waveform, and it is these frequencies for which the impedance should be matched.

 
Fig. 1, B, D, and FGo, shows the frequency spectra obtained from analyzing the intra-arterial pressure traces with a balloon pump inserted that is operating in 1:1, 1:2, and 1:3 mode, respectively (frequency domain). The frequency has been expressed as heart rate normalized to a rate of 60 beats/min to aid interpretation. The term decibel (dB) is the logarithm to the base 10 of a ratio; thus the vertical scales of the graphs are basically logarithmic scales. From Fig. 1,B, D, and FGo, it can be seen that there is at least a 30 dB fall off (which equates to a factor of about 1000) on either side of the frequency peaks, which would relate to a highly significant mismatch (P < .001). Optimal heart rate with the IABP in 1:1 mode was 77 beats/min, in 1:2 mode was 69, 101, and 135 beats/min, and in 1:3 mode 66, 89, 111, and 134 beats/min.

Intraoperative pacing wire placement is routine, especially in high-risk patients. This makes manipulation of the heart rate very easy. Patients have been paced often at a rate that has been found to be their optimal rate, that is, matched impedance, before a decision has been made to insert the IABP.

The data provided proves that there are certain specific optimal rates at which the heart will provide a maximal systolic blood pressure, because of impedance matching. This rate will vary depending on whether the IABP is operating in 1:1, 1:2, or 1:3 mode, because of the different associated harmonic spectra. Multiple potential optimal heart rates occur in 1:2 mode and in 1:3 mode because of harmonic overtones, which are created by the IABP.

Only the case of a patient in sinus rhythm has been considered, but the technique remains valid if the rhythm is regular (this includes atrial flutter and ventricular tachycardia). This means that patients with atrial fibrillation should be ventricular overdrive paced to artificially create a regular rhythm. Irregular waveforms and waveforms with ectopics are unsuitable for this method of analysis.

Thus instead of just adjusting the inflation and deflation times and leaving the heart rate alone, as long as it falls within the physiologic range, we have shown that the heart rate can have a major impact on the functioning, through systolic blood pressure augmentation, of an IABP because of the heart rate dependence of impedance matching.

References

  1. Little WC, Cheng CP. Left ventricular-arterial coupling in conscious dogs. Am J Physiol 1991;261(1 Pt 2):H70-6. [Abstract/Free Full Text]
  2. Burkhoff D, Sagawa K. Ventricular efficiency predicted by an analytical model. Am J Physiol 1986;250(6 Pt 2):R1021-7.
  3. Ross J Jr. Afterload mismatch and preload reserve: a conceptual framework for the analysis of ventricular function. Circ Res 1974;35;117-26.



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Poullis
Fourier analysis of the intra-aortic balloon pump
J. Thorac. Cardiovasc. Surg., September 1, 1999; 118(3): 568 - 568.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Michael Poullis
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Poullis, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Poullis, M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS