J Thorac Cardiovasc Surg 1999;118:998-1005
© 1999 Mosby, Inc.
SURGERY FOR ACQUIRED CARDIOVASCULAR DISEASE |
From The International Heart Institute of Montana Foundation, St Patrick Hospital, 554 West Broadway, Missoula, Mont.
Address for reprints: Carlos M. G. Duran, MD, PhD, The International Heart Institute of Montana Foundation, St Patrick Hospital, 554 West Broadway, Missoula, MT 59801 (E-mail: duran{at}montana.com ).
| Abstract |
|---|
|
|
|---|
-actin and von Willebrandrelated antigen appeared in the fibrin by day 10. By day 30 the flap was fibrotic and retracted whereas the patch and conduit retained their original appearance on the luminal aspect. An endothelium-like layer expressing von Willebrandrelated antigen was present in the patch and conduit but absent in the flap. In contrast, the ethanol-killed implants were free of fibrin by day 10. By day 30, there were no signs of fibrosis or retraction, and a surface layer of cells expressing von Willebrandrelated antigen, characteristic of endothelial cells, was present on all implants. All ethanol-killed implants were repopulated by host cells. | Introduction |
|---|
|
|
|---|
| Methods |
|---|
|
|
|---|
A patch of approximately 1.5 x 2 cm was resected from the harvested pericardium, followed by the construction of a 1.5-cm diameter x 2-cm long conduit. The conduit was constructed by folding the pericardium with the mesothelial surface facing the lumen around a glass cylinder and suturing the free edges with a 5-0 polypropylene continuous running suture. Finally, a 1.5 x 2-cm segment was resected from the pericardium to be used as an intraluminal flap, bisecting the aorta. All these implants were oriented so that the craniocaudal direction of the pericardium was parallel to the aortic flow.
The descending thoracic aorta was isolated with crossclamps placed distal to the arch vessel (in sheep there is only 1 main vessel arising from the arch) and proximal to the takeoff of the first major intercostal or spinal artery. The animals were heparinized to maintain an accelerated clotting time above 300 seconds, after which an apicofemoral shunt was created to bypass the isolated segment of the descending thoracic aorta that received the implants. The patch was used to close a defect created in the aortic wall distal to the crossclamp with a continuous running 5-0 polypropylene suture. The patch was oriented with the mesothelial surface facing the aortic lumen. The aorta was transected distal to the implanted patch and incised longitudinally along its anterior margin for a distance of 2 cm. One edge of the intraluminal flap was sutured to the aortic wall directly opposite the longitudinal incision and the opposite edge was sandwiched under tension between the walls of the aortic incision as the aorta was being closed with a continuous running 5-0 polypropylene suture. Finally, the pericardial conduit was positioned between the proximal and distal ends of the transected aorta with continuous running 5-0 polypropylene sutures (Fig 1). On completion of the operation, protamine was administered at 1.5 times the total heparin dosage with further adjustments determined by the accelerated clotting time. The chest was closed in layers and a chest tube was inserted. After extubation, the chest tube was removed and the animal transferred to its pen.
|
All animals were cared for in accordance with the "Principles of Laboratory Animal Care" formulated by the National Society of Medical Research and the "Guide for the Care and Use of Laboratory Animals" prepared by the Institute of Laboratory Animal Resources, National Research Council, and published by the National Academy Press, revised 1996. The use of the animals for this research was also reviewed and approved by the Institutional Animal Care and Use Committee (IACUC) of the University of Montana.
Histology
The specimens were fixed in Histo-Choice fixative (Amresco Inc, Solon, Ohio), embedded, and sectioned for histologic study. The patch and conduit were sectioned parallel to the direction of blood flow and included the junction between the implants and the aortic wall. Cross sections of the flap and aortic wall were made perpendicular to the blood flow to observe the aortic wall and edges of the flap. Sections were stained with hematoxylin and eosin, which stains nuclei blue and collagen pink, and Massons trichrome, which stains collagen blue and muscle red.
Immunohistochemistry
Sections were cleared of paraffin and treated with 1% hydrogen peroxide in methyl alcohol for 30 minutes to remove endogenous peroxidases. The sections were blocked with 0.05% Tween-20 in phosphate buffered saline solution (PBS-T) for 30 minutes to prevent nonspecific antibody binding. The sections were incubated with either antismooth muscle cell
-actin (clone 1A4) or anti-human von Willebrandrelated antibodies for 30 minutes. Sections were then washed with PBS-T. The sections were incubated for 30 minutes with protein Ahorseradish peroxidase. Sections were washed with PBS-T and visualized with the use of the horseradish peroxidase substrate DAB (Sigma Fast DAB, Sigma Chemical Co, St Louis, Mo). Horseradish peroxidase is an enzyme and, in the presence of hydrogen peroxide, converts DAB into an insoluble dark brown precipitate on the specimens. The development was stopped with water and the slides counterstained with hematoxylin and eosin. Controls included replacing either the antibody or protein A-horseradish peroxidase with PBS-T followed by DAB development. Sections were probed for von Willebrandrelated antigen, a known endothelial cell marker, and smooth muscle cell
-actin, which is expressed in smooth muscle cells and myofibroblasts. The antibodies, protein Ahorseradish peroxidase, Tween-20, and the DAB substrate were obtained from Sigma Chemical Co, St Louis, Missouri, and used according to the manufacturers recommendations.
| Results |
|---|
|
|
|---|
|
Histologic findings
Fresh
DAY 1
Thin fibrin deposits containing polymorphonuclear leukocytes (PMNs) were seen on the luminal surface of the patch and conduit, as well as both surfaces of the flap.
DAY 5
Fibrin deposition and PMNs were present in all fresh implants with the contiguous aorta similarly affected. At all 3 sites, PMNs and spindle-shaped cells that stained weakly for
-actin were observed near the interface between the implant and the fibrin clot.
DAY 10
The luminal surfaces of the patch and conduit showed increased fibrin deposition with cellular debris. Cells that were weakly positive for
-actin were observed near the luminal aspect of the patch and conduit oriented perpendicular to the implant surface. Several layers of cells strongly expressing
-actin were present in the fibrin layers on the surface of the implants. A layer of cells expressing von Willebrand related antigen was observed on the luminal surface of the fibrin. In the flap, different layers of fibrin deposition with various degrees of cellularity were observed on both sides. More cellular activity was apparent at the interface between the implant surface and the fibrin clot than in the interior of the pericardial implant. Cells expressing von Willebrandrelated antigen and
-actin were present at the junction of the fresh flap and aortic wall, but no cells expressing von Willebrandrelated antigen were present on the surface or within the implant.
DAY 15
Multiple layers of cells strongly expressing
-actin were seen at the junctions of the host upstream aorta and the 15-day patch and conduit (Fig 3, A ). Between these cells and the original implant was a layer of organized fibrin with a high degree of cellularity. A discontinuous layer of cells expressing von Willebrandrelated antigen was present on the luminal surface of the implants. Trichrome staining showed that the collagen bundles within the pericardium appeared to be dispersed by cells and new matrix. In the flap, numerous cells expressing moderate levels of
-actin were present at the fibrin-implant interface. Similar to the patch and conduit, multiple layers of
-actinpositive cells were present at the junction between the aortic wall and the fibrin layers of the flap (Fig 3
, B ). No cells expressing von Willebrandrelated antigen were seen on the flap. Trichrome staining indicated the collagen in the original pericardial tissue was dispersed by the deposition of new matrix.
|
-actinpositive cells, also seen in the day 15 implants, extended across the entire implant (Fig 4, A ) and were covered by a layer of endothelium-like cells expressing von Willebrandrelated antigen (Fig 5, A ). Similar to day 15, trichrome staining revealed that newly deposited collagen separated collagen bundles of the original implants (Fig 6). While the patch and conduit were incorporated into a functional structure, the flap was retracted and fibrotic. The fibrotic tissue of the flap was vascularized and contained randomly oriented cells that stained for
-actin with various intensities (Fig 4
-actinpositive cells from the aortic wall onto the implant appeared to be interrupted by the deposition of new fibrin. No endothelium-like cells were present on any portion of the flap (Fig 5
|
|
|
|
-actin-expressing cells in the thin fibrin layer of the luminal side of the implant close to the aortic wall. Cells expressing von Willebrandrelated antigen were present on the luminal surface of the implants but had not formed a continuous monolayer.
No new fibrin deposition was seen on the ethanol-killed flap. Cells positive for
-actin were present at the junction of the aortic wall and implant. An occasional cell staining positive for von Willebrandrelated antigen was seen on both luminal sides of the implant.
DAY 15
The patch and conduit contained multiple layers of spindled-shaped
-actinpositive cells within the remodeled fibrin with few cells seen within the original implant (Fig 3
, C ). A discontinuous layer of cells expressing von Willebrandrelated antigen was also present on the luminal surface of the implants. Trichrome staining showed the collagen bundles of the original implant to be separated by new matrix.
A thin fibrin layer was present on the flap with no new fibrin deposition. The fibrin layer had been remodeled and contained cells, but the implant itself had very few cells. Cells strongly expressing
-actin bridged from the aortic wall into the fibrin layer of the implant (Fig 3
, D ). A layer of cells expressing von Willebrand related antigen was beginning to cover the implant. Trichrome staining revealed that new collagen was produced at the junction of the implant and aorta and within the fibrin layer.
DAY 30
The luminal surface of the patch and conduit had multiple layers of spindle-shaped
-actinpositive cells (Fig 4
, C ) with a continuous surface layer of cells expressing von Willebrandrelated antigen (Fig 5
, C ). Cells were present within the implant, and trichrome staining showed remodeled fibrin with new collagen deposition. The ethanol-killed flap was repopulated by a multilayer of spindle-shaped
-actinexpressing cells that presumably came from the aortic wall (Fig 4
, D ). In contrast to the fresh flap implant, there was a continuous layer of cells expressing von Willebrandrelated antigen on both surfaces of the ethanol-killed flap implant (Fig 5
, D ). Trichrome staining showed the surface fibrin was replaced by collagen.
| Discussion |
|---|
|
|
|---|
The current study was designed in 2 parts. The fresh group provided a picture of the variability of host responses to identical, nonantigenic and viable tissue implanted in the same location but with different configurations. The ethanol-killed group was studied to alleviate the activation of cell types intrinsic to the fresh tissue, which may be responsible for the fibrotic reactions seen in the fresh flap. This experiment was performed to determine whether autologous pericardium transplants, devoid of vital cells, would resist fibrosis in the sheep, a model used in many preclinical studies of cardiovascular implants.
Histologic and immunohistologic examination of the recovered fresh implants indicated that the initial events of the host and the cells in the implants were similar. However, the outcomes of the implants were clearly different. In the fresh patch and conduit, a discontinuous layer of cells expressing von Willebrand related antigen, was present on the surface of the implants covering several layers of
-actinpositive cells. Once these multiple layers of cells were established on the implant, there was no new fibrin deposition. In contrast, the fresh flap had a continuous deposition of new fibrin, which seemed to block movement of cells from the aortic wall into the implant. The cells present within the implant expressed
-actin and remained randomly oriented. It is likely that the activation of these cells was responsible for the contraction and distortion of the original flap implant. No cells expressing von Willebrandrelated antigen were present at any time on the surface of the flap.
Comparison of the fresh and ethanol-killed pericardial implants showed significantly different results, particularly with respect to the flap. The ethanol-killed tissue allowed for ordered recolonization of the implant, formation of a surface layer of cells expressing von Willebrandrelated antigen, characteristic of an endothelium, and completely alleviated the fibrosis seen in the fresh flap. Whether these differences are due to the absence of living cells or to the extraction of factors from the pericardium is not known.
In our study, 50% ethanol treatment for 5 minutes effectively killed all intrinsic cells, as indicated by the absence of vital cells in recovered implants at early time points. Ethanol treatment for 5 minutes was adequate to penetrate the pericardium without causing the tissue shrinkage seen with higher concentrations of ethanol. Recent studies indicated that 80% ethanol may change the structure of the tissue.
17,18 We have not found evidence that 50% ethanol significantly alters tissue structure.
These findings open a new field of possible clinical applications for the use of freshly obtained autologous pericardium treated with ethanol, particularly as an alternative material for valve reconstruction. Additional experimentation is needed to better understand the development of fibrosis observed with fresh autologous pericardial implants. Larger sample numbers, more frequent time points, and growth factor studies may allow for identification of the initial stages of fibrosis. In addition, long-term and calcium content studies need to be performed to ensure the stability of ethanol-killed implants. This laboratory is currently devising methods to isolate fresh and ethanol-killed pericardial flap implants from the aortic wall to prevent fibrotic contributions from host cells.
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
W. A. Goetz, T. E. Tan, K. H. Lim, S. L. H. Salgues, N. Grousson, F. Xiong, Y. L. Chua, and J. H. Yeo Truly stentless molded autologous pericardial aortic valve prosthesis with single point attached commissures in a sheep model Eur. J. Cardiothorac. Surg., April 1, 2008; 33(4): 548 - 553. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Goetz, T. E. Tan, K. H. Lim, F. Xiong, S. L. H. Salgues, N. Grousson, Y. L. Chua, and J. H. Yeo Autologous pericardial pulmonary conduit with single point attached commissures in a sheep model Eur. J. Cardiothorac. Surg., January 1, 2008; 33(1): 48 - 52. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Adachi, T. Yagihara, K. Kagisaki, I. Hagino, T. Ishizaka, M. Koh, H. Uemura, and S. Kitamura Fontan operation with a viable and growing conduit using pedicled autologous pericardial roll: Serial changes in conduit geometry J. Thorac. Cardiovasc. Surg., December 1, 2005; 130(6): 1517 - 1522. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Shomura, S. A. Tahta, E. Lansac, and C. M.G. Duran Hemodynamic evaluation of a new stentless autologous pericardial mitral valve Ann. Thorac. Surg., May 1, 2001; 71 (2007): S315 - S317. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||