| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
With the identification of NOS II in the bronchial epithelium and the advent of technology to measure exhaled NO interest arose in the role of exhaled NO during homeostatic, as well as pathologic conditions. Specifically, it was hypothesized that changes in exhaled NO levels in conditions associated with altered pulmonary mechanics and gas exchange might be a direct result of restricted bronchial epithelial function and NOS activity. Our model of acute hypoxia with reoxygenation resulted in acute lung injury.
7 We hypothesized that exhaled NO might serve as a marker for lung injury in our model and furthermore that exhaled NO does not correlate with plasma nitrite levels. We reasoned that changes in exhaled NO were associated with altered pulmonary mechanics seen during hypoxia-reoxygenation. This study investigated these hypotheses by using an established neonatal piglet model of hypoxia and reoxygenation.
| Materials and methods |
|---|
|
|
|---|
An established model of hypoxia-reoxygenation from our laboratory was used.
7 The piglets were anesthetized with ketamine, intubated with a cuffed endotracheal tube, and mechanically ventilated by using a volume-controled ventilator (Siemens 900B; Siemens-Elema, Solna, Sweden). A constant inhaled tidal volume of 18 mL/kg was maintained with an initial fraction of inspired oxygen (FIO 2) of 40%. Femoral arterial and venous lines were placed. Deep sedation and paralysis were maintained by an infusion of nembutal (20 mg · kg1 · h1), intermittent fentanyl (10 µg · kg1 · h1), and pancuronium (0.2 mg · kg1 · h1). Arterial blood gasses were measured, and co-oximetry was performed every 15 minutes (Chiron Diagnostics Co, East Walpole, Mass).
Transducer-tipped catheters (Millar Instruments Inc, Houston, Tex) were placed in the pulmonary artery and in the right and left ventricles for measuring right ventricular end-diastolic pressure and left ventricular end-diastolic pressure. A Doppler flow probe placed around the pulmonary arterial trunk (T206; Transonic Systems, Inc, Ithaca, NY) was used to monitor cardiac output.
The alveolar PO 2 at an FIO 2 of 40% was calculated by the alveolar gas equation to allow determination of alveolar-arterial gradient. Dynamic airway compliance (Cdyn) and inspiratory airway resistance (RaW) were measured by using the CO2SMO Plus Respiratory Profile Monitor (Novametrix Medical Systems, Inc, Wallingford, Conn). Inspiratory tidal volume was kept constant, and measurements from 10 consecutive breaths were averaged to determine RaW and Cdyn.
Exhaled NO was measured by a Sievers chemiluminescence NO monitor (NOA 270B; Sievers Medical Instruments Inc, Boulder, Colo). Exhaled NO was measured throughout the exhalation cycle with both a peak and a mean value determined by the NOA software (Breath-By-Breath Exhaled NO Software, Version 2.11, Sievers Instruments, Inc). Chemiluminescence NO measurement involved an electrical signal proportional to the light generated from a reaction between NO and ozone. Other laboratories have validated this technique for measuring exhaled NO.
8 The mean exhaled NO value was the average peak value over 10 breaths.
After a 30-minute equilibration period, baseline hemodynamic measurements and arterial blood samples were obtained. The inhaled FIO 2 was decreased to 12% to induce hypoxia, resulting in a systemic saturation of 65% to 70%. Hemodynamic measurements and arterial blood samples were taken at 5, 15, 30, 45, 60, 75, and 90 minutes of hypoxia. Animals were administered fluid boluses of 5 to 10 mL/kg of 0.9% sodium chloride as needed to maintain a mean arterial pressure above 35 mm Hg, with a volume limit of 40 mL/kg. Sodium bicarbonate was given, if needed, to maintain blood pH above 7.3. The ventilator rate was adjusted to maintain the PCO 2 between 38 and 42 mm Hg. The tidal volume remained at 18 ± 1 mL/kg to ensure that changes in pulmonary mechanics accurately reflected alterations in the lungs and were not caused by ventilator manipulation.
After 90 minutes of hypoxia, animals were placed on cardiopulmonary bypass (CPB) with a bypass circuit PO 2 greater than 450 mm Hg. CPB was incorporated to simulate a newborn undergoing repair of congenital heart defects. Arterial cannulation was through the right carotid artery, and venous cannulation was through the right atrial appendage. The ventilator FIO 2 was increased to 100% during CPB, and the rate decreased to 4 breaths per minute to prevent atelectasis. Animals were not actively cooled and were not allowed to drift below a rectal body temperature of 32°C to minimize the effects of hypothermia. Flow rates on CPB were maintained at 100 mL · kg1 · min1, with a minimum mean arterial pressure of 35 mm Hg.
After 1 hour of CPB, animals were warmed to 38°C, weaned from CPB, and returned to normoxic conditions (FIO 2 = 40%). The animals were maintained under similar conditions as baseline for 2 hours. Blood samples were obtained for the measurement of aortic and pulmonary arterial nitrite, and exhaled NO and hemodynamics were recorded at 15, 30, 60, and 120 minutes of recovery.
An additional 5 animals (group II) were instrumented, maintained at normoxia (FIO 2 = 40%) for 90 minutes, placed on CPB for 1 hour, and allowed to recover for an additional 2 hours. These animals served as controls to demonstrate any changes from CPB alone. Other investigators have confirmed the minimal effect of bypass in similar models.
9
Tissue myeloperoxidase assay
Frozen lung samples collected at baseline, end hypoxia, and end recovery were homogenized in 1 mL of a solution containing 0.5% hexadecyltrimethyl-ammonium bromide dissolved in 10 mmol/L 3-[N -morpholino]propanesulfonic acids and then centrifuged at 21,000g for 20 minutes at 4°C. The supernatant (100 µL) was mixed with 700 µL of sodium phosphate (80 mmol/L, pH 5.5) and 100 µL of tetramethyl benimide (16 mmol/L) and incubated at 25°C for 5 minutes. Then 100 µL of 1 mmol/L hydrogen peroxide was added and incubated for exactly 3 minutes at 25°C. A blank without hydrogen peroxide was also analyzed for each tissue. The reaction was stopped by the addition of 1 mL of cold acetic acid (2 mol/L). The optical density was measured at 650 nm on a spectrophotometer (Labsystems Multiscan MCC/340, Franklin, Mass). Myeloperoxidase (MPO) activity was expressed as units per 50 mg of tissue per 3 minutes. MPO activity is representative of leukocyte activity in the tissue.
Tissue lipid peroxidase assay
Frozen lung tissue was homogenized in 10 volumes (1 mL/100 mg) of 10% (vol/vol) 1.15% potassium chloride on ice. A modified thiobarbituric acid reaction technique was used. The optical density at 532 nm was measured, and concentration was determined by using a Spectronic Genesys spectrophotometer (Spectronic Instruments, Rochester, NY). Concentrations were calculated with the use of standard solutions of malondialdehyde-dimethylacetate (0.5-16 nmol) and expressed as nanomoles per 100 mg of wet tissue. Tissue lipid peroxidase measurements are an indication of membrane peroxidation, a marker of free radicalmediated injury.
Nitrite assay
Blood levels of NO were estimated by measurement of aortic and pulmonary arterial nitrate and nitrite by using a 2-part assay converting nitrate to nitrite by the Griess reaction.
10,11 The optical density of each well was read at 550 nm, with correction at 650 nm (Labsystems Multiscan MCC/340). The data were analyzed by using GENESIS software (Fisher Scientific Co, Pittsburgh, Pa), and total nitrite levels (in micromoles per liter) were reported. Pulmonary arterial nitrite values were not obtained from 2 animals, and values from 2 other animals were several SDs from the mean and were excluded secondary to presumed collection or processing error. Hence, pulmonary arterial nitrite values are reported from 6 animals compared with 10 animals for the aortic nitrite values.
Statistical analysis
Data were reported as the mean ± SD. Analysis of variance and the 2-tailed paired Student t test were used to compare values at different time points. A P value of less than or equal to .05 was considered significant (Statview 4.01 software; Abacus Concepts Inc, Berkeley, Calif).
| Results |
|---|
|
|
|---|
|
|
Impairment in exhaled NO production was associated with alterations in pulmonary function and mechanics. Dynamic pulmonary compliance decreased significantly from 6.6 ± 0.9 mL/cm H2O at baseline to 5.0 ± 0.7 mL/cm H2O at end hypoxia and 5.4 mL/cm H2O at end recovery (P = .05 compared with baseline; Fig 2). Concomitant with the decrease in Cdyn, RaW increased over baseline during hypoxia and reoxygenation (41 ± 4 cm of H2O · L1 · s1 at baseline, 56 ± 4.9 cm H2O · L1 · s1 at end hypoxia, and 50 ± 5 cm H2O · L1 · s1 at end recovery; Fig 2
). Gas exchange in group I, as determined by alveolar-arterial gradient, was significantly lower after reoxygenation than at baseline (84 vs 32 mm Hg, P = .005). In contrast, the alveolar-arterial gradient was only slightly above the baseline level in group II animals after CPB (41 vs 53 mm Hg, P = .11). RaW and Cdyn were not significantly changed from baseline at end recovery in group II (Table I
).
|
|
| Discussion |
|---|
|
|
|---|
The current study demonstrated that marked decreases in exhaled NO were associated with changes in pulmonary mechanics and increased MPO and LPO in pigs subjected to hypoxia and subsequent reoxygenation on CPB. In addition, to test whether changes in exhaled NO correspond to decreased pulmonary vascular or systemic NO production, both aortic and pulmonary arterial nitrite levels were measured as an estimate of NO production. No association was found between aortic or pulmonary arterial nitrite levels and exhaled NO after reoxygenation.
Our findings supported the proposed concept that exhaled NO correlates poorly with plasma nitrite levels.
17,18 There was a persistent decline in exhaled NO after reoxygenation, whereas both aortic and pulmonary arterial nitrite measurements returned to baseline levels. The significance of exhaled NO and the relationship to plasma nitrite levels remains controversial. One explanation for the divergence in exhaled NO and plasma nitrite levels is that exhaled NO reflects airway NO production generated by NOS II, which is constitutively expressed in bronchial epithelium,
19 whereas plasma nitrite presumably reflects NO produced either from the pulmonary endothelium, systemic NO production, or both. In support of this concept is the fact that hemoglobin binds NO with high affinity and reduces it to nitrate and nitrate, thereby curtailing the crossing of pulmonary arterial NO into the bronchial tree.
17,18
Acute pulmonary injury from hypoxia-reoxygenation might adversely affect bronchial NOS II activity, whereas vascular NOS, which is derived from many sources in the body, might not be affected to the same degree. The decrease in both aortic and pulmonary arterial nitrite during hypoxia was associated with decreases in exhaled NO. This is consistent with what is known regarding the effect of hypoxia on NOS activity. However, once normoxic condition returned, both pulmonary arterial and aortic nitrite levels increased back to baseline values, suggesting recovery of pulmonary endothelial NOS activity and NO production. In contrast, exhaled NO remained depressed, actually decreasing further after reoxygenation. Because NO produced by vascular endothelium is rapidly reduced by hemoglobin rather than readily passing into the alveolus, we believe that the changes occurring in exhaled NO represented a distinct process.
17,18 Studies are currently underway to look specifically at bronchial NOS II activity compared with pulmonary NOS activity in this model.
Although measurement of plasma nitrite and nitrate is an accepted method of estimating blood levels of NO, this method somewhat limits the attempts to compare changes in exhaled NO with blood NO levels. Inferences from nitrite measurements must be viewed cautiously because nitrite measurements are only a marker of NO levels. The lack of an easily applied in vivo method to directly measure NO levels in the blood is a limiting factor in studies looking at in vivo NO changes. Furthermore, because of the longer half-life of nitrite compared with NO itself and because of the difference in sample number for the pulmonary arterial and aortic nitrite values, no conclusions can be inferred from attempts to determine a transpulmonary gradient of nitrite. However, the postreoxygenation increase in both pulmonary arterial and aortic nitrite compared with the continued decline of exhaled NO does appear significant.
In our model the dual insults of hypoxia and subsequent reoxygenation on CPB resulted in more pronounced acute lung injury than CPB alone, which resulted in trivial alterations in pulmonary mechanics and PVR and no change in exhaled NO. There is significant variation, especially in animal studies, regarding the effect of CPB on pulmonary function. However, the absence of significant injury after CPB alone in our model is supported both by other animal studies
20,21 and clinical experience in which patients are commonly extubated within 12 hours of surgery with minimal pulmonary changes. The use of an identical bypass circuit and oxygenator to those used clinically in our institution, the lack of significant cooling, the use of proper donor blood handling and storage, and the participation of a clinical perfusionist minimized the effect of CPB in our model and provided a clinically relevant and consistent method of reoxygenation. It has been suggested that CPB alone might decrease exhaled NO levels. Beghetti and colleagues
22 demonstrated a modest decrease in exhaled NO from children undergoing CPB. However, inhalational anesthetics that are known to decrease exhaled NO are often used in clinical settings and might contribute to a decrease in exhaled NO production. In the current study exhaled NO levels did not change during or after CPB in the control animals.
Baseline exhaled NO levels in the current study were within the range of 20 to 35 ppb, which was previously measured in human beings and animals.
12,23 With the onset of hypoxia, exhaled NO progressively decreased with reduced inspired oxygen. This was consistent with the findings of Nelin and associates,
12 who demonstrated decreased exhaled NO during hypoxia in an isolated piglet lung model. A similar decrease in exhaled NO was also seen when the NOS inhibitor N -nitro-L -arginine methyl ester (L -NAME) was administered to normoxic control lungs. Other researchers have shown a similar, although more modest, decrease in exhaled NO with moderate hypoxia and a more marked decrease when FIO 2 was below 5%. The rapid decrease in exhaled NO associated with hypoxia might be a direct inhibitory effect of inspired FIO 2 (alveolar PO 2) or pulmonary arterial PO 2 on NOS II activity.
24 In contrast, the continued decrease in exhaled NO detected during reoxygenation and recovery might be due to bronchial epithelial injury.
Decreased exhaled NO levels have been associated with altered pulmonary mechanics in numerous pathologic conditions.
4,12-14 Changes in exhaled NO might be a marker of airway disease and injury, as well as an indicator of the effectiveness of therapy. In this study decreased exhaled NO was associated with decreased pulmonary compliance and increased airway resistance despite a fixed tidal volume.
A unifying explanation of the data is that hypoxia-reoxygenation injury resulted in bronchial epithelial injury and dysfunction, led to decreased exhaled NO production, and contributed to altered airway resistance and pulmonary compliance. Increased MPO activity and LPO levels after reoxygenation implied that leukocyte-mediated reoxygenation injury occurred. It was notable that animals subjected to CPB without preceding hypoxia did not have increased MPO activity or LPO levels. It is likely that reoxygenation injury was not limited to the bronchial epithelium and that other areas of the lung, such as the pulmonary vascular endothelium, might also have been affected.
This study demonstrated that decreased exhaled NO was associated with altered pulmonary mechanics during hypoxia. Furthermore, there was a poor association between plasma nitrite levels and exhaled NO, suggesting two distinct entities. After reoxygenation, exhaled NO levels remained depressed, possibly indicating bronchial epithelial injury. Bronchial epithelial dysfunction and decreased bronchial NO production might contribute to the persistent changes in pulmonary mechanics detected after hypoxia and reoxygenation.
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
M. M.H. Cheung, R. K. Kharbanda, I. E. Konstantinov, M. Shimizu, H. Frndova, J. Li, H. M. Holtby, P. N. Cox, J. F. Smallhorn, G. S. Van Arsdell, et al. Randomized Controlled Trial of the Effects of Remote Ischemic Preconditioning on Children Undergoing Cardiac Surgery: First Clinical Application in Humans J. Am. Coll. Cardiol., June 6, 2006; 47(11): 2277 - 2282. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Oishi, A. Azakie, C. Harmon, R. K. Fitzgerald, A. Grobe, J. Xu, K. Hendricks-Munoz, S. M. Black, and J. R. Fineman Nitric oxide-endothelin-1 interactions after surgically induced acute increases in pulmonary blood flow in intact lambs Am J Physiol Heart Circ Physiol, May 1, 2006; 290(5): H1922 - H1932. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Pearl, S. M. Schwartz, D. P. Nelson, C. J. Wagner, J. M. Lyons, S. M. Bauer, and J. Y. Duffy Preoperative glucocorticoids decrease pulmonary hypertension in piglets after cardiopulmonary bypass and circulatory arrest Ann. Thorac. Surg., March 1, 2004; 77(3): 994 - 1000. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kovesi, D. Royston, M. Yacoub, and N. Marczin Basal and nitroglycerin-induced exhaled nitric oxide before and after cardiac surgery with cardiopulmonary bypass Br. J. Anaesth., May 1, 2003; 90(5): 608 - 616. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. L. Starnes, B. W. Duncan, C. H. Fraga, S. Y. Desai, T. K. Jones, S. K. Mathur, G. L. Rosenthal, and F. M. Lupinetti Rat model of pulmonary arteriovenous malformations after right superior cavopulmonary anastomosis Am J Physiol Heart Circ Physiol, November 1, 2002; 283(5): H2151 - H2156. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. H. Cuthbertson, S. A. Stott, and N. R. Webster Exhaled nitric oxide as a marker of lung injury in coronary artery bypass surgery Br. J. Anaesth., August 1, 2002; 89(2): 247 - 250. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Pearl, D. P. Nelson, C. J. Wagner, J. P. Lombardi, and J. Y. Duffy Endothelin receptor blockade reduces ventricular dysfunction and injury after reoxygenation Ann. Thorac. Surg., August 1, 2001; 72(2): 565 - 570. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. KHARITONOV and P. J. BARNES Exhaled Markers of Pulmonary Disease Am. J. Respir. Crit. Care Med., June 1, 2001; 163(7): 1693 - 1722. [Full Text] [PDF] |
||||
![]() |
T. D. Le Cras and I. F. McMurtry Nitric oxide production in the hypoxic lung Am J Physiol Lung Cell Mol Physiol, April 1, 2001; 280(4): L575 - L582. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Pearl, D. W. Thomas, G. Grist, J. Y. Duffy, and P. B. Manning Hyperoxia for management of acid-base status during deep hypothermia with circulatory arrest Ann. Thorac. Surg., September 1, 2000; 70(3): 751 - 755. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |