J Thorac Cardiovasc Surg 2001;121:1216-1218
© 2001 The American Association for Thoracic Surgery
Brief Communications |
From the Department of Surgery II, Tokyo Medical University, Tokyo, Japan.
Received for publication Oct 12, 2000. Accepted for publication Oct 23, 2000. Address for reprints: Taro Shimazaki, MD, Department of Surgery II, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo 160-0023, Japan (E-mail: taro-shi{at}pa2.so-net.ne.jp).
The advantages of stent-graft entry closure for aortic dissection were introduced by the Stanford group.
1 Stent-graft placement is expected to be a promising treatment for acute aortic dissection. The purpose is to seal a primary entry by endovascular stent-grafting, thereby decompressing the false lumen and leading to thrombosis in the false lumen. However, in the case of renal or mesenteric artery malperfusion from a false lumen, stent-graft entry closure might result in ischemic organ failure caused by thrombosis of the false lumen. We report on a case of aortic dissection associated with renal and mesenteric artery malperfusion that was treated successfully by stent-graft entry closure and balloon fenestration to secure kidney and intestinal blood flow.
Clinical summary
A 42-year-old man with a chronic Stanford type B dissection was a candidate for stent-graft treatment. A primary entry site was detected at the proximal descending thoracic aorta. The superior mesenteric artery and left renal artery could not be delineated by preoperative angiograms of the true lumen, which indicated that they were perfused from the false lumen(Fig 1). After informed consent was obtained, the endovascular procedure was performed in the operating room with the patient under general anesthesia. An intravascular ultrasonic (IVUS) catheter (6F, 12.5 Mz, Sonicath; Boston Scientific Co, Boston, Mass) was introduced via the right femoral artery into the aorta. On the contralateral femoral artery, a 5F pigtail catheter (Cook Group Incorporated, Bloomington, Ind) was introduced over a 0.035-inch stiff guide wire (Amplatz Super Stiff; Boston Scientific Co). Under IVUS monitoring and fluoroscopic guidance, a guide wire was passed through the intimal flap into the false lumen.
|
Flow of contrast material from the true lumen to the superior mesenteric artery was not detected by digital subtraction angiography (
Fig l, B). We thought that fenestration by means of balloon was necessary to preserve the blood flow to the intestine. A balloon catheter with a balloon diameter of 10 mm (Boston Scientific Co) was advanced over the guide wire from the true lumen to the false lumen and positioned across the intimal flap(Fig 2). A postprocedural digital subtraction angiogram indicated flow to the false lumen through the new entry we had created.
|
|
|
The purpose of stent-graft replacement is to seal the intimal tear and decompress the false lumen. Stent-graft placement is expected to be less invasive than standard open surgery. It is difficult to estimate the amount of thrombus that has formed in the false lumen, because there are many variations of entry and re-entry localizations in each case. Intestinal or leg ischemia and renal failure are all possible complications when the renal or mesenteric arteries are perfused from the false lumen. Particularly in these cases, stent-graft entry closure and balloon fenestration seem to be ideal methods of therapy.
We performed balloon fenestration under IVUS observation. The location of the dissected flap and guide wire could be easily visualized by IVUS monitoring.
Slonim and associates
3 reported that false lumen obliteration was successfully treated with endovascular stent placement and balloon fenestration for aortic dissection. In our experience, stent-graft entry closure after balloon fenestration is a less invasive endovascular treatment in the case of type B dissection associated with organ malperfusion. In this case, we used a 10-mm balloon to effect the fenestration. Further investigation will be necessary to determine the optimal balloon size.
References
This article has been cited by other articles:
![]() |
G. G. Hartnell and J. Gates Aortic Fenestration: A Why, When, and How-to Guide RadioGraphics, January 1, 2005; 25(1): 175 - 189. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Grabenwoger, T. Fleck, M. Czerny, D. Hutschala, M. Ehrlich, M. Schoder, J. Lammer, and E. Wolner Endovascular stent graft placement in patients with acute thoracic aortic syndromes Eur. J. Cardiothorac. Surg., May 1, 2003; 23(5): 788 - 793. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |