J Thorac Cardiovasc Surg 2001;122:257-269
© 2001 The American Association for Thoracic Surgery
Surgery for Acquired Cardiovascular Disease (ACD) |
From the Divisions of Cardiothoracic Surgery,b Cardiology,a and Biostatistics,c Departments of Surgeryb and Medicine,a The Cedars-Sinai Medical Center Burns & Allen Research Institute, University of California at Los Angeles School of Medicine, Los Angeles, Calif, and the Division of Cardiothoracic Surgery, St John's Hospital,c Santa Monica, Calif.
Received for publication June 29, 1999. Revisions requested Sept 8, 1999; revisions received Jan 22, 2001. Accepted for publication Feb 19, 2001. Address for reprints: Steven S. Khan, MD, Division of Cardiothoracic Surgery, Cedars-Sinai School of Medicine, 8700 Beverly Blvd, Room 6215, Los Angeles, CA 90048 (E-mail: khan{at}cshs.org).
Abstract
Objective: We sought to compare outcomes with tissue and St Jude Medical mechanical valves over a 20-year period.
Methods: Valve-related events and overall survival were analyzed in 2533 patients 18 years of age or older undergoing initial aortic, mitral, or combined aortic and mitral (double) valve replacement with a tissue valve (Hancock, Carpentier-Edwards porcine, or Carpentier-Edwards pericardial) or a St Jude Medical mechanical valve. Total follow-up was 13,390 patient-years. There were 666 St Jude Medical aortic valve replacements, 723 tissue aortic valve replacements, 513 St Jude Medical mitral valve replacements, 402 tissue mitral valve replacements, 161 St Jude Medical double valve replacements, and 68 tissue double valve replacements. The mean age was 68 ± 13.3 years (St Jude Medical valve, 64.5 ± 12.9; tissue valve, 72.0 ± 12.6).
Results: There were no overall differences in survival between tissue and mechanical valves. Multivariable analysis indicated that the type of valve did not affect survival. Analysis by age less than 65 years or 65 years or older and presence or absence of coronary disease revealed similar long-term survival in all subgroups. The risk of hemorrhage was lower in patients receiving tissue aortic valve replacements but was not significantly different in patients receiving mitral valve or double valve replacements. Thromboembolism rates were similar for tissue and mechanical valve recipients. However, reoperation rates were significantly higher in patients receiving both aortic and mitral tissue valves. The reoperation hazard increased progressively with time both in patients receiving aortic and in those receiving mitral tissue valves. Overall valve complications were initially higher with mechanical aortic valves but not with mechanical mitral valves. However, valve complication rates later crossed over, with higher rates in tissue valve recipients after 7 years in patients undergoing mitral valve replacement and 10 years in those undergoing aortic valve replacement.
Conclusions: Tissue and mechanical valve recipients have similar survival over 20 years of follow-up. The primary tradeoff is an increased risk of hemorrhage in patients receiving mechanical aortic valve replacements and an increased risk of late reoperation in all patients receiving tissue valve replacements. The risk of tissue valve reoperation increases progressively with time.
Treatment options in patients with valvular heart disease have expanded significantly in the past decade to include procedures like the Ross procedure, homograft aortic and mitral valves, stentless tissue valves, and more widespread use of mitral valve repair. Despite these newer procedures, valve replacement with a prosthetic mechanical valve or with porcine or pericardial xenograft valves remains the standard procedure for most patients with significant valvular heart disease. Although several randomized studies have examined differences in outcomes between patients with tissue and mechanical valves,
1,2 in clinical practice valve selection is not random. Instead, the selection of a type of prosthetic valve is made primarily on the basis of patient age,
3 valve position, patient comorbidity, and the risks and benefits of anticoagulation. Significant insights into the performance of tissue and mechanical prosthetic valves in real-life settings can be gained by analysis of a large series of patients receiving these valves. Therefore, the primary purpose of this article is to provide long-term outcome data on the results of prosthetic heart valve replacement, stratifying by valve position (aortic vs mitral) and type of valve received (tissue vs St Jude Medical mechanical valve replacement), over a 20-year period.
Methods
Data on patients undergoing valve replacement at Cedars-Sinai Medical Center, a private, university-affiliated, tertiary-care medical center, have been prospectively entered into a computerized database since 1969. Patients are mailed annual questionnaires, and those reporting possible events are contacted by a research nurse. If a questionnaire is not returned, a protocol of repeat mailings followed by telephone calls to the patient or his or her physician is followed. The National Death Index is queried for patients whose status cannot be determined. The percentage of patients classified as lost to follow-up was 2.6% (66/2533). However, another 3.6% (92/2533) of patients are in the midst of the follow-up protocol, and some of these may eventually be classified as lost to follow-up. The recommendations of The American Association for Thoracic Surgery and Society of Thoracic Surgeons for reporting valve-related morbidity and mortality
4 were used as guidelines to analyze patient outcomes. However, operative mortality in this study was defined to include all deaths occurring during the hospitalization for the operation or within 30 days of the operation. Deaths within 30 days of reoperation on an operated valve were included as valve-related deaths and as valve complications.
Patient selection
Patients over the age of 18 years who had either a porcine or pericardial tissue valve or St Jude Medical bileaflet mechanical valve (St Jude Medical, Inc, St Paul, Minn) implanted in the mitral or aortic positions were included in this study. The analysis was restricted to patients operated on during or after 1976. Tissue valve recipients received either a standard (models 242 [aortic] or 342 [mitral]) or modified-orifice aortic (model 250H) Hancock porcine valve (Medtronic, Inc, Minneapolis, Minn) or a Carpentier-Edwards porcine (model 2625 [aortic] or model 6625 [mitral]) or Carpentier-Edwards bovine pericardial aortic valve (model 2700) (Edwards Lifesciences Corporation, Irvine, Calif). Patients were excluded if they received homografts or a combination of both porcine and mechanical valves or if they had any prior valve replacement.
Postoperative management
Patients with mechanical valves were started on a regimen of warfarin after the operations. Before 1987, warfarin was adjusted to maintain the prothrombin time (PT) ratio (patient PT/control PT) at 1.5 to 2.5 times the control value. From 1987 to 1992, the PT ratio was maintained at 1.5 to 2.0 times the control value. Since 1992, warfarin has been titrated to a target international normalized ratio of 2.5 to 3.5. Patients with mitral tissue valves routinely received warfarin for 3 months after the operation. Before 1992, the dose was adjusted to 1.3 to 1.5 times the control value and subsequently adjusted to an international normalized ratio of 2.0 to 3.0. Warfarin therapy in patients with aortic tissue valves was optional and determined by factors such as patient age and risk factors for bleeding or thromboembolism. Tissue valve recipients received long-term aspirin (325 mg orally each day) postoperatively once warfarin was discontinued. Management of anticoagulation after hospital discharge was performed by the patient's own physician but generally followed these guidelines.
Statistical methods
Comparisons between continuous variables were made by means of t tests or analysis of variance as appropriate. Comparisons between categorical variables were made by the Fisher exact test or the
2 test. All baseline factors that differed between tissue and mechanical valve groups were used to test whether valve type was predictive of overall survival after adjusting for baseline differences in risk factors. A stepwise Cox proportional hazards regression analysis was used to select a set of covariates predictive of survival by using a P-to-enter value of .10. The final covariate model was then compared with the same model plus valve type. Valve type was considered predictive of survival if the likelihood ratio test was significant at the .05 level. Survival was estimated by using actuarial life-table methods. Survival curve plots inFigures 1 to 3, 5, and 6 are stopped when the population is less than 8 patients. Because of the small number of double valve recipients, the survival analysis and Cox multivariable analyses were only performed in the patients receiving aortic and mitral valve replacements. However, linearized event rates are presented for the patients receiving double valve replacements.
|
|
|
|
|
|
In the comparison of valve complications, the survival curves for the tissue and mechanical valves cross over each other, complicating the analysis of statistical significance. Therefore, 2 tests of statistical significance are presented for these event rates, both calculated with BMDP 2L (BMDP Software, Los Angeles, Calif).
7 The first, the Generalized Wilcoxon-Breslow (Breslow) statistic, weights early events to a greater extent and will therefore be more sensitive to early divergence of the valve event curves. The second test, the Generalized Savage (Mantel-Cox), is similar to the log-rank test and weights early and late events equally.
Results
Patient characteristics
Basic preoperative patient characteristics are presented in Table 1 stratified by valve type. Mechanical valve recipients were younger than tissue valve recipients (P = .0001) and more often female. Patients receiving tissue and mechanical valves also differed in the cause of valve disease. Patients with papillary muscle infarction or ischemia were more likely to receive mechanical valves than porcine valves (P = .0006). However, degenerative aortic valve disease was the most common cause for both tissue and mechanical aortic valve replacement.
|
Valve-related complications
The 2 most common and most clinically significant long-term complications of valve replacement are embolic events and hemorrhage. There were no significant differences in embolic events for either the aortic or the mitral tissue and mechanical valve recipients(Figure 1
, A and B). At 15 years, between 71% and 75% of all patients were free of embolic events after tissue and mechanical valve replacement, respectively, regardless of valve position. The linearized rates of valve-related events are shown in Table 2 for aortic, mitral, and double valve recipients. The overall rate of in situ valve thrombosis was 0.21% per year for mechanical valves and 0.02% per year for tissue valves. The overall linearized embolism rate was 2.3% per year for all tissue valves and 2.8% per year for the St Jude Medical mechanical valves.
|
Other valve complications were less common. No structural valve failure occurred in the St Jude Medical valve recipients (7463 patient-years of exposure). However, 107 of the tissue valve recipients had documented structural valve failure (5928 patient-years). Perivalvular leak occurred in 13 mechanical valve recipients and in 6 tissue valve recipients. Significant hemolysis occurred in 3 of the St Jude Medical valve recipients (linearized rate, 0.04% per year) but not in any of the tissue valve recipients. Endocarditis occurred in 61 patients overall, 24 receiving mechanical valves and 37 receiving tissue mitral valves. Erosion (left ventricular rupture) occurred infrequently: 4 mechanical and 6 tissue valve recipients had erosion, all early after the operation and most in the setting of a recent acute myocardial infarction.
8 Pannus formation (tissue ingrowth) was only reported in 2 mechanical valve recipients, with a linearized rate of 0.027% for mechanical valve recipients and 0% for tissue valve recipients.
Reoperation
As would be expected, actuarial reoperation rates were significantly higher for tissue valve recipients(Figure 3
). Examination of these curves reveals similar freedom from reoperation for tissue and mechanical valves until approximately 7 years after the operation, when the curves rapidly begin to diverge. As Figure 4
, A and B, demonstrate, the annual risk (hazard) of undergoing reoperation increases progressively with time for the tissue valves. For both aortic and mitral tissue valves, the hazard is low until approximately 6 years and then rises at a progressively faster rate.
Trend analysis of the hazard function for tissue valve reoperation between 6 months and 19 years reveals a significant trend for the hazard to rise progressively over time (correlation of 0.91, P < .01) for the combined aortic and mitral valve replacement data, indicating that the risk of reoperation does not level off but progressively increases the longer a patient has had a tissue valve implanted. As can be seen by comparing panels A and B ofFigure 4
, there are 2 effects driving tissue valve reoperation: (1) a valve position effect in which mitral valve reoperation rates are about twice as high as those for aortic valves and (2) a progressively increasing risk of tissue valve failure with time that appears to be intrinsic to tissue valves.
Reoperation rates were also analyzed by using the actual or cumulative method. This technique provides an answer to the following question: What proportion of the patients will require reoperation before they die? The actual freedom from reoperation is graphed inFigure 3
, A and B, and also listed in Table 3. At 5, 10, and 15 years, 1.45%, 1.75%, and 1.82% of mechanical valve recipients had actually undergone reoperation. However, in the tissue valve recipients, at 5, 10, and 15 years 1.89%, 10.5%, and 21.4%, respectively, had required reoperation. Thus, although at 5 years actual reoperation rates were similar, by 10 and 15 years there were clear differences in actual reoperation rates between tissue and mechanical valves.
|
Multivariable survival analysis
A Cox multivariable analysis was performed to adjust for differences in the baseline patient characteristics between the tissue and mechanical valve groups. Variables considered for inclusion were those found to differ significantly between the tissue and mechanical valve recipients in the univariate analysis. These variables included patient age, sex, type of valve (tissue or mechanical), presence of coronary disease, and New York Heart Association class IV status. In addition, diabetes was included in the models, although it was not a significant univariate predictor. Initially, the aortic and mitral valve recipients were analyzed together along with terms testing for interactions between risk factors and valve position. This revealed significant interactions between the presence of coronary disease and valve position (P = .03) and between age and valve position (P < .001). Therefore, the Cox model analyses were then conducted separately for the aortic and mitral valve recipients, and the results are shown in Table 4. The final Cox model indicated that age, New York Heart Association class IV status, and diabetes mellitus were significant predictors of survival for both the aortic and mitral valve recipients. Coronary disease was a significant predictor only for the mitral valve recipients. Importantly, tissue or mechanical valve type was not a significant predictor of survival in either the combined analysis or in the separate aortic or mitral analysis. The type of tissue valve implanted (porcine vs pericardial) and the type of porcine valve implanted (Carpentier-Edwards porcine vs Hancock porcine) did not affect survival.
|
Overall valve complications
The analysis of all valve complications is plotted inFigure 6
, A and B, and includes valve thrombosis, embolism, hemorrhage, perivalvular leak, structural failure, endocarditis, pannus formation, annular erosion, reoperation, valve-related death, death within 30 days of reoperation, valve failure, and hemolysis. Early valve complication rates were initially slightly higher for mechanical valves in both the aortic and mitral positions, although the differences were of borderline significance only for the aortic valves (P = .03, Breslow). This early difference is probably the result of the higher hemorrhage rate seen in the mechanical aortic valve recipients.
However, the valve complication curves inFigure 6
demonstrate a crossover point for both the aortic and mitral valve recipients. For the mitral valve recipients, this crossover point occurs at approximately 7 to 8 years, and for the aortic valve recipients, it occurs at 10 years. Before this point, freedom from valve complications is better for tissue valve recipients than for mechanical valve recipients, whereas after the crossover point, freedom from complications is better for mechanical valve recipients. Statistical testing confirmed that late complication rates were significantly higher for the mitral tissue valve recipients (P = .04, Mantel Cox statistic). This crossover likely occurs as the rate of tissue valve reoperation accelerates and outweighs the constant ongoing risk of anticoagulant-related hemorrhage with mechanical valves.
Discussion
This study demonstrates similar outcomes in tissue and mechanical valve recipients over a 20-year period. The small difference in survival of younger (<65 year of age) patients with mechanical mitral valves was of borderline significance and disappeared after adjustment for age. The risk of embolism did not differ between tissue and mechanical valves for either the aortic or mitral valve recipients. The primary difference in outcomes seen between these valve types was a higher risk of hemorrhage in the aortic mechanical valve recipients and a higher risk of structural failure in all tissue valve recipients. The crossover point in overall valve complications between tissue and mechanical valves is logical and follows from the progressively increasing rate of tissue valve reoperation balanced against a constant higher risk of hemorrhage in the mechanical valve recipients. The later crossover point of aortic valve recipients compared with that of mitral valve recipients is consistent with the higher rate of mitral valve recipient reoperation.
One of the most interesting observations in this study is the data set on the annual risk (hazard) of tissue valve reoperation. Analysis of the hazard (annualized rate) of tissue valve reoperation suggests that the risk of valve reoperation begins to rise in years 6 to 8 and increases progressively with time. No leveling off or reduction in risk of tissue valve failure was seen, and in fact, the plots of the hazard functions suggest a steady acceleration in the risk of tissue valve failure with time. These data provide a real-world estimate of the performance of these commonly implanted heart valves in a relatively elderly general population and demonstrate that the choice of a tissue or mechanical valve is primarily a balance of the risk of anticoagulation against the risk of reoperation.
Comparison of the linearized rates of hemorrhage and embolism for our St Jude Medical valve recipients with the literature demonstrates that our findings are consistent with series from the United States reported by Kratz,
9 Fernandez,
10 and their colleagues and with the hemorrhage rates reported by Ibrahim and coworkers
11 from Ireland. However, our embolism rates are higher than those from Japan reported by Aoyagi,
12 Nakano,
13 and their associates and from Arom and coworkers
14 in the United States and Baudet and colleagues
15 in France. The higher rates of embolic events may be related to the greater age of our patients compared with those in these other series. For example, our overall mean patient age was 68 ± 13 years, whereas the mean patient ages in the series from Japan by Aoyagi and colleagues
12 and Nakano and coworkers
13 were 52 and 48 years, respectively. Our previous data suggest that the variation in thromboembolism rates in prosthetic valve recipients is strongly associated with nonvalvular patient risk factors for stroke, such as age and the presence of coronary disease.
16
The embolism rates in our tissue valve recipient population are also somewhat higher than those observed by other authors, whereas our reoperation rates are lower. Fann and associates
17 reported freedom from thromboembolism at 15 years of 87% for aortic valve recipients and 77% for mitral valve recipients compared with that in our series, in which 70% of aortic valve recipients and 73% of mitral valve recipients were free of embolism. However, the average patient ages in this series were 60 and 58 years for aortic and mitral valve recipients, respectively, compared with an average age for tissue valve recipients in our series of 72 years. As might be expected from this difference in patient age, freedom from reoperation was higher in our series. Thus, at 15 years, freedom from reoperation in the series of Fann and colleagues was 53% for aortic valve recipients and 33% for mitral valve recipients compared with 67% for aortic valve recipients and 52% for mitral valve recipients in our series. In a series by Jones and coworkers,
18 74% of aortic valve recipients and 61% of mitral valve recipients were free of reoperation for all causes at 10 years. Jamieson and colleagues,
19 in a series of 1181 patients with Carpentier-Edwards standard porcine valves, reported freedom from structural failure of 40.6% in aortic valve recipients and 8.5% in mitral valve recipients compared with our freedom from reoperation of 48.9% for aortic valve recipients and 26.0% for mitral valve recipients. These figures are not exactly comparable because we are reporting freedom from reoperation compared with freedom from structural failure and the population of Jamieson and coworkers is much younger (mean age of 57.9 years compared with our mean age of 68 years). In a somewhat older series of 1007 patients (all over 70 years; mean age, 75.6 years) receiving tissue valves, Pupello and colleagues
20 reported a better freedom from structural failure: 80.4% at 15 years for aortic valve recipients and 84.6% for mitral valve recipients. Thus, our tissue valve reoperation rates fit between published series with younger and older patient populations.
The rates of other valve complications in our series are comparable with those reported by other authors. For example, the endocarditis rate was 0.3% per year for mechanical valve recipients in our series for both aortic and mitral valve recipients, which is similar to the 0.3% reported by Nitter-Hauge and Abdelnoor
21 in 1104 patients with the Medtronic Hall prosthesis and the 0.3% reported for all patients by Ibrahim and colleagues.
11 The rate of valve thrombosis was 0.3% and 0.2% in our series for aortic and mitral valve recipients compared with 0.1% for aortic and mitral valve recipients in the series by Nitter-Hauge and Abdelnoor.
21
Limitations
Although our conclusions regarding the relative limitations of mechanical and tissue valves agree with conventional thinking about the relative risks of hemorrhage and reoperation, several limitations must be kept in mind. First, our study was not a randomized comparison of tissue and St Jude Medical valves, and this creates the potential for bias in valve selection. Although we have tried to adjust for these differences in the survival analysis by using multivariable methods, there may be variables that were not adjusted for because they were not measured. However, the variables analyzed here completely explain any potential differences in survival, suggesting that other variables would not add to our understanding of survival differences. A second limitation is the use of standard porcine and pericardial valves. Other tissue valves, such as stentless valves and aortic homografts, or the Ross procedure may demonstrate different outcomes and event rates. We have also been unable to differentiate between major and minor thromboembolic events, which is an intrinsic limitation of our database. A final possible limitation is the combination of multiple types of tissue valves in the analysis: the Carpentier-Edwards porcine valve, the Hancock standard or modified orifice valves, and the Carpentier-Edwards pericardial valve. However, a recently published randomized trial with 1369 patient-years of follow-up demonstrated that there are no significant differences in durability between the Hancock and Carpentier-Edwards porcine valves.
22 It remains less clear whether there are differences in event rates and durability between standard porcine valves and the Carpentier-Edwards pericardial valve. However, it is important to point out that because the Carpentier-Edwards pericardial valve has only been used at our institution since 1992, the acceleration of the risk of valve reoperation at 7 to 10 years observed in the overall tissue valve group does not necessarily apply to this valve.
In summary, survival was similar after adjustment for risk factors with tissue and St Jude Medical mechanical valves in both aortic and mitral valve recipients. An increase in hemorrhage was seen in the aortic mechanical valve recipients, but embolism rates did not differ between valve types. Reoperation rates were significantly higher in all tissue valve recipients and appeared to accelerate after about 10 years. These data suggest that outcomes after tissue and mechanical valve replacement are similar, with the primary tradeoff being the risks of anticoagulant-related hemorrhage in mechanical aortic valve recipients versus the risk of reoperation after 8 to 10 years in tissue valve recipients.
Appendix: Discussion
Dr W. R. Eric Jamieson (Vancouver, British Columbia, Canada). Dr Trento, this is a very important contribution because we now have to begin to identify the performance of biologic mechanical prostheses up to at least 15 years and maybe on to 20 years in our decision making with regard to what we offer and recommend to our patients. What you have really shown is that valve-related complications, reoperation, and survival are all very important points. Your summary slide does show that there is some preponderance of performance in aortic position with regard to less hemorrhage and with regard to putting in bioprostheses versus mechanical prostheses. In the mitral position there is not that major differentiation.
I have a number of questions for you, and the first concerns how you handled thromboembolism. You have not defined it. Is it all major events or both major and minor events, and did you include the events that occurred in the first 30 days?
Dr Trento. We included all events, both major and minor, including the first 30 days.
Dr Jamieson. Is there a difference between the major events that occurred with the mechanical prosthesis versus those occurring with the biologic prosthesis?
Dr Trento. We have not analyzed these differences. We had about 250 episodes of hemorrhage, but we did not analyze the major and minor hemorrhages.
Dr Jamieson. There is another point with relation to thromboembolism. In your article you note a number of thrombosis casesI think 6 in the mechanical series and 4 in the tissue series. Could you elaborate on those? Were they aortic or mitral, and how were they managed?
Dr Trento. I do not remember whether they were aortic or mitral. Now we manage valve thrombosis by infusion of streptokinase, and that has been quite successful in our practice.
Dr Jamieson. I was interested because of the 6 cases in the mechanical series and the 4 cases in the biologic series. We have seen similar experience in the mechanical and mitral valves but not in the biologic valves.
You discussed a number of cases as annular erosion or left ventricular rupture. Were these early cases or late cases? Were they atrioventricular groove disruptions?
Dr Trento. The way they were classified is affected by the fact that this is a 20-year data collection. Annular erosion and ventricular disruption are the same thing, the typical atrioventricular groove disruption.
Dr Jamieson. Did you see any cases in which the strut of the prosthesis eroded the ventricular wall? We saw this early in our experience if we inserted too large a mitral prosthesis, depending on the orientation.
Dr Trento. I think that all these events were early events. They were perioperative events.
Dr Jamieson. In your article you relate to the management of ischemic disease and muscle disruption, in which you implant a mechanical prosthesis in these patients. My concern is whether these patients have enough comorbidity to offer them a biologic prosthesis or whether these patients really do very well after muscle disruption in a mechanical prosthesis.
Dr Trento. This is obviously a process that may have changed over time in our practice. There have probably been about 15 surgeons over a period of 20 years performing these procedures. At the present time, it is the surgeon's decision as to what type of prosthesis to use in the presence of acute myocardial necrosis, and therefore we do not have a generalized and unified approach to this type of situation.
Dr Jamieson. Your article deals also with the concept of actual freedom versus actuarial freedom. A proponent of that is Dr Gary Grunkemeier, who is a member of our Association and who is here. One of the ways we are starting to look at our data is the actuarial freedom from mortality and reoperation but also permanent impairment or permanent morbidity to the patients. I know you did not analyze this. You did analyze it for reoperation but with regard to thromboembolism. Do you think that looking at the concept of actual freedomwhich is really better information for our patientswould be more appropriate?
Dr Trento. It is an interesting concept to look at the actual freedom from debilitating events and something that we should probably do. The concept of actual versus actuarial is a difficult concept to grasp. The actuarial concept looks at the valve and tells us how long the valve is going to last. The actual concept looks at the patient and tells us what the chance is for this patient to have a valve reoperation after 15 years. I think that expanding the actual concept to complication events other than reoperation may be very interesting.
Dr Jamieson. I have a question related to your reoperative mortality with regard to biologic prosthesis, specifically with regard to structural valve deterioration. Has that lessened over the years? Would you tend to place biologic prostheses in specific indications as a result?
Dr Trento. I do not think there was a statistical difference in operative mortality between reoperations and first-time reoperation. The operative mortality was slightly higher. We did 108 reoperations. I could not tell whether the incidence of mortality in the recent reoperations was much better.
Dr Jamieson. In our experience in the past 9 years, our mortality with reoperating on aortic or mitral valves is not different, and it was approximately 4%.
It would be nice to see further age stratification of your data and maybe further actuarial analysis, but you did not indicate in your article whether this influenced your current practice. What is your recommended practice?
Dr Trento. I think that this article came out to be quite neutral, and we did not mean it in this way. We are open minded, and after reviewing the article, I think that each of you can probably arrive at different conclusions. I can only tell you my personal approach. Patients over age 65 years get a porcine aortic biologic prosthesis. Patients under age 60 years get either a mechanical prosthesis or some other type of procedure. For mitral valve recipients, patients over age 60 years with coronary artery disease probably get a biologic prosthesis, but that again is my preference. I think there are 8 surgeons in our group, and each of them has his own approach.
Dr Jamieson. Our current approach, according to a recent analysis of our data using the actuarial methodology, is that in the mitral position we place a bioprosthesis for patients over 70 years unless they have extensive comorbid disease. Patients under 70 years receive a mechanical prosthesis if the valve is not being repaired. In the aortic position, using actuarial methodology, our freedom from structural failure in patients over 70 years is 95% at 15 years, and in those patients between 61 and 70 years, the actuarial freedom is 88% at 15 years. Of course, below that you have the role of stentless prosthesis, autografts, and homografts.
Acknowledgments
We thank Dr Timothy Denton and Dr Richard Gray, without whose help this article would not have been possible.
Footnotes
Read at the Twenty-fifth Annual Meeting of The Western Thoracic Surgical Association, Olympic Valley (Lake Tahoe), Calif, June 23-26, 1999. ![]()
*Chairman, Global Healthcare Alliance; Chairman Emeritus, Cardiothoracic Surgery, Cedars-Sinai Medical Center. ![]()
References
This article has been cited by other articles:
![]() |
C. A. Yankah, M. Pasic, M. Musci, J. Stein, C. Detschades, H. Siniawski, and R. Hetzer Aortic valve replacement with the Mitroflow pericardial bioprosthesis: Durability results up to 21 years J. Thorac. Cardiovasc. Surg., September 1, 2008; 136(3): 688 - 696. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. L. Brown, H. V. Schaff, B. D. Lahr, C. J. Mullany, T. M. Sundt, J. A. Dearani, C. G. McGregor, and T. A. Orszulak Aortic valve replacement in patients aged 50 to 70 years: Improved outcome with mechanical versus biologic prostheses. J. Thorac. Cardiovasc. Surg., April 1, 2008; 135(4): 878 - 884. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Sughimoto, K. Nakano, A. Gomi, H. Nakatani, Y. Nakamura, and A. Sato Hancock Valve Deterioration in Tricuspid Position for Ebstein's Anomaly Asian Cardiovasc Thorac Ann, April 1, 2008; 16(2): 157 - 158. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Eitz, S. Schenk, D. Fritzsche, A. Bairaktaris, O. Wagner, H. Koertke, and R. Koerfer International Normalized Ratio Self-Management Lowers the Risk of Thromboembolic Events After Prosthetic Heart Valve Replacement Ann. Thorac. Surg., March 1, 2008; 85(3): 949 - 955. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A.C. Ennker, A. A. Albert, U. P. Rosendahl, I. C. Ennker, F. Dalladaku, and I. Florath Ten-Year Experience With Stentless Aortic Valves: Full-Root Versus Subcoronary Implantation Ann. Thorac. Surg., February 1, 2008; 85(2): 445 - 453. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Emery, A. M. Emery, A. Knutsen, and G. V. Raikar Aortic Valve Replacement with a Mechanical Cardiac Valve Prosthesis Card. Surg. Adult, January 1, 2008; 3(2008): 841 - 856. [Full Text] |
||||
![]() |
T. Gudbjartsson, T. Absi, and S. Aranki Mitral Valve Replacement Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068. [Full Text] |
||||
![]() |
J. L. Svennevig, M. Abdelnoor, and S. Nitter-Hauge Twenty-Five Year Experience With the Medtronic-Hall Valve Prosthesis in the Aortic Position: A Follow-Up Cohort Study of 816 Consecutive Patients Circulation, October 16, 2007; 116(16): 1795 - 1800. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Vicchio, A. Della Corte, M. De Feo, G. Santarpino, L. S. De Santo, G. Romano, G. Caianiello, M. Scardone, and M. Cotrufo Quality of Life After Implantation of Bileaflet Prostheses in Elderly Patients: An Anticoagulation Work Group Experience Ann. Thorac. Surg., August 1, 2007; 84(2): 459 - 465. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Ota, S. Taketani, S. Iwai, S. Miyagawa, M. Furuta, M. Hara, E. Uchimura, Y. Okita, and Y. Sawa Novel Method of Decellularization of Porcine Valves Using Polyethylene Glycol and Gamma Irradiation Ann. Thorac. Surg., April 1, 2007; 83(4): 1501 - 1507. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kulik, P. Bedard, B-K. Lam, F. D. Rubens, P. J. Hendry, R. G. Masters, T. G. Mesana, and M. Ruel Mechanical versus bioprosthetic valve replacement in middle-aged patients. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 485 - 491. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Rizzoli, S. Mirone, P. Ius, E. Polesel, T. Bottio, L. Salvador, C. Zussa, G. Gerosa, and C. Valfre Fifteen-year results with the Hancock II valve: A multicenter experience. J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 602 - 609.e4. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Sawaki, A. Usui, T. Abe, M. Yoshikawa, T. Akita, and Y. Ueda Late Mortality and Morbidity in Elderly Patients with Mechanical Heart Valves Asian Cardiovasc Thorac Ann, June 1, 2006; 14(3): 189 - 194. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Chan, W.R.E. Jamieson, E. Germann, F. Chan, R.T. Miyagishima, L.H. Burr, M.T. Janusz, H. Ling, and G.J. Fradet Performance of bioprostheses and mechanical prostheses assessed by composites of valve-related complications to 15 years after aortic valve replacement J. Thorac. Cardiovasc. Surg., June 1, 2006; 131(6): 1267 - 1273. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. W. Akins, A. D. Hilgenberg, G. J. Vlahakes, J. C. Madsen, T. E. MacGillivray, G. M. LaMuraglia, and R. P. Cambria Late Results of Combined Carotid and Coronary Surgery Using Actual Versus Actuarial Methodology Ann. Thorac. Surg., December 1, 2005; 80(6): 2091 - 2097. [Abstract] [Full Text] [PDF] |
||||
![]() |
I Florath, A Albert, U Rosendahl, T Alexander, I C Ennker, and J Ennker Mid term outcome and quality of life after aortic valve replacement in elderly people: mechanical versus stentless biological valves Heart, August 1, 2005; 91(8): 1023 - 1029. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Emery, C. C. Krogh, K. V. Arom, A. M. Emery, K. Benyo-Albrecht, L. D. Joyce, and D. M. Nicoloff The St. Jude Medical Cardiac Valve Prosthesis: A 25-Year Experience With Single Valve Replacement Ann. Thorac. Surg., March 1, 2005; 79(3): 776 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ruel, A. Kulik, B. K. Lam, F. D. Rubens, P. J. Hendry, R. G. Masters, P. Bedard, and T. G. Mesana Long-term outcomes of valve replacement with modern prostheses in young adults Eur. J. Cardiothorac. Surg., March 1, 2005; 27(3): 425 - 433. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Potter, T. M. Sundt III, K. J. Zehr, J. A. Dearani, R. C. Daly, C. J. Mullany, C. G.A. McGregor, F. J. Puga, H. V. Schaff, and T. A. Orszulak Operative risk of reoperative aortic valve replacement J. Thorac. Cardiovasc. Surg., January 1, 2005; 129(1): 94 - 103. [Abstract] [Full Text] [PDF] |
||||
![]() |
J P A Puvimanasinghe, J J M Takkenberg, M B Edwards, M J C Eijkemans, E W Steyerberg, L A van Herwerden, K M Taylor, G L Grunkemeier, J D F Habbema, and A J J C Bogers Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation Heart, October 1, 2004; 90(10): 1172 - 1178. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Minakata, H. V. Schaff, K. J. Zehr, J. A. Dearani, R. C. Daly, T. A. Orszulak, F. J. Puga, and G. K. Danielson Is repair of aortic valve regurgitation a safe alternative to valve replacement? J. Thorac. Cardiovasc. Surg., March 1, 2004; 127(3): 645 - 653. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Vink, R. A. Kraaijenhagen, B. A. Hutten, R. B. A. van den Brink, B. A. de Mol, H. R. Buller, and M. Levi The optimal intensity of vitamin k antagonists in patients with mechanical heart valves: A meta-analysis J. Am. Coll. Cardiol., December 17, 2003; 42(12): 2042 - 2048. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Ikonomidis, J. M. Kratz, A. J. Crumbley III, M. R. Stroud, S. M. Bradley, R. M. Sade, and F. A. Crawford Jr Twenty-year experience with the St Jude Medical mechanical valve prosthesis J. Thorac. Cardiovasc. Surg., December 1, 2003; 126(6): 2022 - 2031. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Emery, C. A. Erickson, K. V. Arom, W. F. Northrup III, T. E. Kersten, T. J. Von Rueden, and D. M. Nicoloff Replacement of the aortic valve in patients under 50 years of age: long-term follow-up of the St. Jude medical prosthesis Ann. Thorac. Surg., June 1, 2003; 75(6): 1815 - 1819. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Emery, G. J. Van Nooten, and P. J. Tesar The initial experience with the ATS Medical mechanical cardiac valve prosthesis Ann. Thorac. Surg., February 1, 2003; 75(2): 444 - 452. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. L. Grunkemeier and Y. Wu "Our complication rates are lower than theirs": Statistical critique of heart valve comparisons J. Thorac. Cardiovasc. Surg., February 1, 2003; 125(2): 290 - 300. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. D. Desai and G. T. Christakis Stented Mechanical/Bioprosthetic Aortic Valve Replacement Card. Surg. Adult, January 1, 2003; 2(2003): 825 - 856. [Full Text] |
||||
![]() |
T. Gudbjartsson, S. Aranki, and L. H. Cohn Mechanical/Bioprosthetic Mitral Valve Replacement Card. Surg. Adult, January 1, 2003; 2(2003): 951 - 986. [Full Text] |
||||
![]() |
C. W. Akins, A. D. Hilgenberg, G. J. Vlahakes, T. E. MacGillivray, D. F. Torchiana, and J. C. Madsen Results of bioprosthetic versus mechanical aortic valve replacement performed with concomitant coronary artery bypass grafting Ann. Thorac. Surg., October 1, 2002; 74(4): 1098 - 1106. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Cebotari, H. Mertsching, K. Kallenbach, S. Kostin, O. Repin, A. Batrinac, C. Kleczka, A. Ciubotaru, and A. Haverich Construction of Autologous Human Heart Valves Based on an Acellular Allograft Matrix Circulation, September 24, 2002; 106(12_suppl_1): I-63 - I-68. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||