JTCS Speed Up Your Browser
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kumar, A. S.
Right arrow Articles by Choudhary, S. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kumar, A. S.
Right arrow Articles by Choudhary, S. K.
Related Collections
Right arrow Great vessels
Right arrow Valve disease

J Thorac Cardiovasc Surg 2001;122:378-379
© 2001 The American Association for Thoracic Surgery


Evolving Technology (ET)

Mitral valve replacement with the pulmonary autograft: The Ross II procedure

A. Sampath Kumar, MCh, Saket Aggarwal, MS, Shiv Kumar Choudhary, MCh, New Delhi, India

From the Cardiothoracic Centre, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India.

Received for publication Nov 30, 2000. Accepted for publication Jan 2, 2001. Address for reprints: A. Sampath Kumar, Professor, Department of Cardiothoracic & Vascular Surgery, Ansari Nagar, New Delhi—110 029, India (E-mail: askumar{at}medinst.ernet.in asampath_kumar@hotmail.com).

The search for an ideal valve substitute continues. Although RossGo 1 described the use of a pulmonary autograft for mitral valve replacement in 1967, interest in this operation only now is being renewed because of the many advantages.Go Go 2,3 We report one such operation with a technique that was developed in our center.

Patient and methods

A 35-year-old man had had progressive shortness of breath and palpitations for 6 years. Clinical examination showed classic features of severe mitral stenosis with severe pulmonary arterial hypertension. The transthoracic echocardiogram showed severe calcific mitral stenosis with a mitral valve area of 0.6 cm2. There was no other valvular involvement. He was admitted for mitral valve replacement.

Transesophageal echocardiography was performed soon after intubation. The pulmonary valve anulus measured 29 mm in diameter with a normal structure. The heart was approached through a median sternotomy and vertical pericardiotomy. The pulmonary artery was carefully dissected free of the aorta and looped. A marker suture was placed on the pulmonary artery just at the distal end of the sinuses. Moderately hypothermic (28°C) cardiopulmonary bypass was established with aortic and bicaval cannulation. Cold blood cardioplegia and topical ice slush were used for myocardial protection. The left atrium was opened and retracted with a Cooley retractor. The mitral valve was severely stenosed and calcified. No thrombus was found in the atrium or in the appendage. The valve was excised, preserving the subvalvular apparatus.

The pulmonary artery was incised just distal to the marker stitch and transected, with care taken to leave a 2-mm rim of pulmonary artery beyond the commissural pillars. The pulmonary valve was inspected and found to be tricuspid and competent. The right ventricular outflow tract was incised 3 to 4 mm proximal to the pulmonary anulus. With careful dissection, the autograft was explanted and hemostasis was secured. The pulmonary anulus measured 29 mm. Three sutures were then passed through the mitral anulus at equidistant points. These sutures were then passed through the top of the autograft commissures with the autograft in an upside-down position. The sutures were tied. The autograft was inverted into the left ventricle, and the distal end of the autograft was sutured completely to the mitral anulus in a continuous fashion. An appropriate sized stent was fashioned with thick nonporous Teflon felt(Figure 1). The circumference was measured with a 29-mm valve sizer, and the height of the pillars was the height of the pulmonary valve commissures. Three additional sutures were placed at the point of the commissural sutures, and these were passed through the top of the pillars of the stent. The stent ends were closed with a suture to form a ring support to the pulmonary autograft at its proximal end. Three sutures were passed through the pulmonary autograft at the commissures about 2 mm below the pillars. These sutures were passed through the ring of the stent at the appropriate points and though the left atrial wall, which was gathered 2 cm upstream of the mitral anulus. These were tied and run continuously as the proximal suture line for the autograft, incorporating the ring stent. The sutures were tightened with a nerve hook and tied. Figure 2 shows the anatomy after completion of autograft insertion. The valve was tested for competence by injection of saline solution into the left ventricle with a bulb syringe and was found to be competent.



View larger version (62K):
[in this window]
[in a new window]
 
Fig. 1. The stent, designed from thick nonporous Teflon felt.

 


View larger version (91K):
[in this window]
[in a new window]
 
Fig. 2. Diagram of the completed autograft implantation.

 
The right ventricular outflow tract was reconstructed with a cryopreserved pulmonary homograft obtained from our own tissue valve bank. The heart was deaired, the patient was rewarmed to 37°C, and bypass was discontinued.

Results

The cardiopulmonary bypass time was 130 minutes and the aortic clamp time was 100 minutes. Transesophageal echocardiography confirmed good autograft function with no mitral regurgitation and no gradient across the valve (Figure 3). The postoperative recovery was smooth, and the patient was discharged on the 10th postoperative day. Transthoracic echocardiography before discharge showed a functioning autograft without any stenosis or regurgitation. The patient is doing well 3 months after the operation.



View larger version (56K):
[in this window]
[in a new window]
 
Fig. 3. Two-dimensional transesophageal echocardiogram showing the pulmonary autograft in the left atrium.

 
Discussion

The renewed interest in the use of the pulmonary autograft for the mitral valve as reported by Kabbani and associatesGo 2 prompted us to attempt this in our patients because of the many advantages offered by the autograft. Our technique differs from those reported by Ross,Go 1 Yacoub and Kittle,Go 4 and Kabbani and associatesGo 2 in that we have not used a top-hat technique. Instead, we fashioned a stent with Teflon felt, which was used to support the autograft and provided certain advantages. The stent is completely buried and does not come in contact with the bloodstream. The stent is somewhat similar in shape and size to the stent used for bioprosthetic valves and is easily fashioned on the table with the measurements taken from the autograft itself. The autograft sinuses are intact and free to billow during valve closure, as was observed during echocardiography after the operation, providing physiologic function to the valve. Unlike the top-hat technique, here the valve is not restrained within a prosthetic graft tube.

Acknowledgments

We thank Dr Akhil Govil forFigure 2Go.

References

  1. Ross DN. Replacement of aortic and mitral valves with a pulmonary autograft. Lancet. 1967;2:956-8.[Medline]
  2. Kabbani SS, Ross DN, Jami H, Hammoud A, Nabhani F, Hariri R, et al. Mitral valve replacement with a pulmonary autograft: initial experience. J Heart Valve Dis. 1999;8:359-67.[Medline]
  3. Al Hales ZA, Awad MM, Pielers F, Shahid MS, Al Amri MA. Six-year follow-up of a pulmonary autograft in the mitral position: the Ross II procedure. J Thorac Cardiovasc Surg. 1999;117:614-6.[Free Full Text]
  4. Yacoub MH, Kittle CF. A new technique for replacement of the mitral valve by a semilunar valve homograft. J Thorac Cardiovasc Surg. 1969;58:859-69.[Medline]



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Kabbani, H. Jamil, F. Nabhani, A. Hamoud, K. Katan, N. Sabbagh, A. Koudsi, L. Kabbani, and G. Hamed
Analysis of 92 mitral pulmonary autograft replacement (Ross II) operations.
J. Thorac. Cardiovasc. Surg., October 1, 2007; 134(4): 902 - 908.e7.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
L. Ma, P. Tozzi, C. H. Huber, S. Taub, G. Gerelle, and L. K. von Segesser
Double-crowned valved stents for off-pump mitral valve replacement
Eur. J. Cardiothorac. Surg., August 1, 2005; 28(2): 194 - 198.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Athanasiou, A. Cherian, and D. Ross
The Ross II Procedure: Pulmonary Autograft in the Mitral Position
Ann. Thorac. Surg., October 1, 2004; 78(4): 1489 - 1495.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
T. Gudbjartsson, S. Aranki, and L. H. Cohn
Mechanical/Bioprosthetic Mitral Valve Replacement
Card. Surg. Adult, January 1, 2003; 2(2003): 951 - 986.
[Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J.-P. Chang, H.-I Lu, C.-L. Kao, M.-S. Lu, and M.-J. Hsieh
Combination of the Ross II operation with stentless bioprosthesis and radiofrequency maze IV operation
J. Thorac. Cardiovasc. Surg., December 1, 2002; 124(6): 1252 - 1253.
[Full Text]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kumar, A. S.
Right arrow Articles by Choudhary, S. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kumar, A. S.
Right arrow Articles by Choudhary, S. K.
Related Collections
Right arrow Great vessels
Right arrow Valve disease


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS