J Thorac Cardiovasc Surg 2002;123:973-976
© 2002 The American Association for Thoracic Surgery
Evolving Technology (ET) |
From the Institut Mutualiste Montsouris, Paris, France.
Received for publication Aug 9, 2001. Revisions requested Sept 25, 2001; revisions received Oct 4, 2001. Accepted for publication Oct 9, 2001. Address for reprints: Emmanuel Le Bret, MD, Departement Cardio-Vasculaire, L'Institut Mutualiste Montsouris, 42 Boulevard Jourdan, 75014 Paris, France (E-mail: emmanuel.lebret{at}imm.fr).
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
| Material and methods |
|---|
|
|
|---|
Children were distributed into 2 groups (Table 1).
In group 1, 28 infants (age, 3 weeks-15 years; mean age, 33 months; weight, 2.3-57 kg; mean weight, 13.3 kg; sex ratio, 5:1 girls/boys) underwent the videothoracoscopic procedure. In group 2, 28 infants (age 2 months-5
years; mean age, 20 months; weight, 3.2-22.5 kg; mean weight, 10.7 kg; sex ratio, 6:1 girls/boys) underwent a robotically assisted procedure.
|
After induction of general anesthesia and standard intubation, the patient is positioned as for a left posterolateral thoracotomy. The surgeon and the scrub nurse are on the left side of the patient, and the assistant is on the right. The monitor is placed on the right side of the patient, facing the surgeon. Instruments used for videothoracoscopy include an electrocautery hook, a clip applier, and three 60° angled hooks for lung retraction.
Two small incisions with a No. 11 blade are made in the left hemithorax: the first incision is made just posterior to the scapula in the third intercostal space for the videothoracoscope (4 mm in diameter) to be introduced through a 5-mm trocar. A second incision is performed in the fourth intercostal space underneath the angle of the scapula for the electrocautery hook to be introduced through a 5-mm trocar. Three 60° angled hooks of 1 mm in diameter are introduced directly through the third intercostal space in its middle part, just in front of the scapula, for lung retraction (Figure 1).
|
Group 2
The Zeus System (Computer Motion, Inc, Goleta, Calif) includes 1 voice-controlled robotic arm (automated endoscope system for optimal positioning [AESOP]), 2 instrument positioners, 1 surgeon console, and 1 interface controller. The instruments and the videoscope are coupled to the robotic arm with adjustable magnetic couplers. The telemanipulation system and technical details have been described elsewhere.
3 For PDA closure, the voice-controlled robotic arm is positioned on the foot side on the left rail, and instrument positioners are installed on the head side on the left rail and the foot side on the right rail.
Preparation, installation of the patient, anesthesia, incisions, and introduction of instruments are the same as in group 1.
The videoscope is attached to the AESOP arm, the 2 first 60° angled hooks for lung retraction are held by the assistant, the third hook is connected to the left arm of the robot, and the electrocautery hook is held by the right arm of the robot. Once instruments are installed and connected to the robot, the surgeon leaves the table and moves to the console. Seated in front of the console, the surgeon works with 2 instruments: a hook retractor controlled with the right hand and an electrocautery hook controlled with the left hand. Using a foot-switch pedal, the tips of the instruments can be temporarily disconnected from the master handles, which can be repositioned in the working space to achieve the most convenient ergonomic position.
The whole dissection of the pleural reflection, of the aorta, and of the ductus is carried out from the console. When the ductus is completely dissected from the surrounding tissues, the surgeon goes back to the operating table and places the 2 clips in the same way as in group 1.
Postoperative care
Color flow Doppler echocardiography is performed in the operating room or in the recovery room before extubation to assess the completeness of closure of the PDA. If a persistent shunt is noted, the patient is taken back immediately to the operating room for application of a new clip by means of videothoracoscopy. If complete interruption is obtained, the child is extubated and placed either in the intensive care unit (ICU) or in the pediatric ward according to his or her age and the possible previous symptoms of pulmonary hypertension. The pleural suction catheter is removed a few hours after extubation, a routine chest radiograph is obtained, and a transthoracic echocardiogram is done before the patient is discharged. All patients are then regularly followed up by the referring pediatric cardiologist on the 10th day after discharge and after 6 months.
Data analysis
In both groups total operating room time, surgical procedure time, conversion for technical failure or surgical problems, and accidents of dissection were analyzed. The following postoperative data were analyzed: duration of ICU and hospital stay, continuance of persistent shunt, reoperation, temporary or permanent laryngeal nerve injury, chylothorax, pneumothorax, wound infections, hemorrhages, and blood transfusions.
This study was approved by the ethics committee of our institution, and informed consent was obtained from the parents of the patients.
| Results |
|---|
|
|
|---|
|
Postoperative data
Postoperative data are listed in Table 3.
There was no difference between the 2 groups in terms of ICU and hospital length of stay. In both groups the mean ICU stay was less than 6 hours, and the postoperative ventilation time was less than 2 hours.
|
A persisting shunt was observed in 3 patients (1 in group 1 and 2 in group 2). The 3 children were reoperated on the same day by means of the thoracoscopic approach. In all patients the persisting shunt was related to an incomplete dissection of the ductus and misplacement of the clips.
No residual shunt was noted at discharge. No chylothorax, no wound infection, and no hemorrhage were observed. One pneumothorax in group 1 required percutaneous drainage. No midterm complications, including recurrence of ductal shunting, were observed.
| Discussion |
|---|
|
|
|---|
The Zeus system (Computer Motion) used in this study is a master-slave telemanipulator, the modular units of which can be freely mounted on the operating table. The voice-activated robotic arm, AESOP, is used to guide a videoscope, which obeys simple 1- or 2-word commands.
In 1998, Carpentier and colleagues
4 performed the first robotic cardiac surgical procedures in adults, including an atrial septal defect closure and several mitral valve repairs. Recently, Mohr and associates
5 published their experience, in which they brought mitral valve surgery to a near-endoscopic procedure. In 1999, endoscopic robotic coronary operations were described.
6,7 Despite the elegance of the robotic technique, the authors insisted on the difficulty of achieving the dissection and the anastomosis.
The current study demonstrates that endoscopic PDA closure with robotically assisted instrumentation is technically feasible in children, even in low-weight babies. The dissection of the aorta, of the subclavian artery, and of the ductus can be safely achieved. Indeed, neither accident nor particular difficulties were observed in our experience. The exposure of the duct and lung retraction was obtained by using 2 angled hooks held by an assistant in the same way as in the videothoracoscopic technique. As a matter of fact, failure in exposition was the cause of the unique conversion to thoracoscopy in our experience.
Intraoperative data show that the operating room time and the surgical procedure duration were significantly higher in the robotic group, with the difference remaining constant throughout the whole experience and therefore regardless of the learning curve. This difference is not due to specific surgical difficulties but rather to the technical complexity of the robot placement. In this experience an engineer was present in the operating room during the procedure to take care of the possible technical failures and breakdowns. Despite our increasing experience and the permanent maintenance of the machine, technical flaws could not be totally eliminated.
Our experience was extremely useful because it allowed us to demonstrate that, after a learning period during which the exact position of the robotic tools had to be determined, the robotic arms could be installed and mobilized easily and safely and could perform all the maneuvers required by the surgical procedure. In addition, because no case of infection had been observed in this experience, we may state that those cumbersome tools can be safely decontaminated and protected and that their use does not increase the risk of infection.
In conclusion, our experience with the robotic approach for PAD interruption in children did not prove to be either superior or inferior to the videothoracoscopic technique used in our institution since 1991 in terms of safety, quality of outcome, and reduction of complication. It appears more complicated, demanding, and time-consuming and presently has no particular advantage over the regular technique. The next step will be to improve the technology to provide the robot with a certain degree of autonomy. This will be a real additional value in the performance of a certain surgical task.
| References |
|---|
|
|
|---|
kur ouvert assisté par ordinateur. Premier cas opéré avec succès. CR Acad Sci III. 1998;321:437-42.This article has been cited by other articles:
![]() |
P. Modi, E. Rodriguez, and W. R. Chitwood Jr. Robot-assisted cardiac surgery Interactive CardioVascular and Thoracic Surgery, September 1, 2009; 9(3): 500 - 505. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Dexter, E. U. Dexter, D. Masursky, and N. A. Nussmeier Systematic Review of General Thoracic Surgery Articles to Identify Predictors of Operating Room Case Durations Anesth. Analg., April 1, 2008; 106(4): 1232 - 1241. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Nezafati, G. Soltani, and A. Vedadian Video-Assisted Ductal Closure With New Modifications: Minimally Invasive, Maximally Effective, 1,300 Cases Ann. Thorac. Surg., October 1, 2007; 84(4): 1343 - 1348. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Folliguet, F. Vanhuyse, X. Constantino, M. Realli, and F. Laborde Mitral valve repair robotic versus sternotomy Eur. J. Cardiothorac. Surg., March 1, 2006; 29(3): 362 - 366. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. A. Russell, K. Rouine-Rapp, G. Stratmann, and W. C. Miller-Hance Congenital heart disease in the adult: a review with internet-accessible transesophageal echocardiographic images. Anesth. Analg., March 1, 2006; 102(3): 694 - 723. [Full Text] [PDF] |
||||
![]() |
Y. Suematsu, B. N. Mora, T. Mihaljevic, and P. J. del Nido Totally Endoscopic Robotic-Assisted Repair of Patent Ductus Arteriosus and Vascular Ring in Children Ann. Thorac. Surg., December 1, 2005; 80(6): 2309 - 2313. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. A. Folliguet, F. Vanhuyse, Z. Konstantinos, and F. Laborde Early experience with robotic aortic valve replacement Eur. J. Cardiothorac. Surg., July 1, 2005; 28(1): 172 - 173. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hashizume and K. Tsugawa Robotic Surgery and Cancer: the Present State, Problems and Future Vision Jpn. J. Clin. Oncol., May 1, 2004; 34(5): 227 - 237. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Villa, F. V. Eynden, E. Le Bret, T. Folliguet, and F. Laborde Paediatric video-assisted thoracoscopic clipping of patent ductus arteriosus: experience in more than 700 cases Eur. J. Cardiothorac. Surg., March 1, 2004; 25(3): 387 - 393. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Berman, A. Stamler, B. A. Vidne, and M. Saute Computer-enhanced thoracoscopic thymectomy with the Zeus telemanipulation surgical system Interactive CardioVascular and Thoracic Surgery, September 1, 2003; 2(3): 262 - 264. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Mihaljevic, J. W. Cannon, and P. J. del Nido Robotically assisted division of a vascular ring in children J. Thorac. Cardiovasc. Surg., May 1, 2003; 125(5): 1163 - 1164. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |