JTCS Speed Up Your Browser
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Walter Benno Eichinger
Bernhard M. Kemkes
Niels Bleese
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eichinger, W. B.
Right arrow Articles by Bleese, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eichinger, W. B.
Right arrow Articles by Bleese, N.
Related Collections
Right arrow Valve disease

J Thorac Cardiovasc Surg 2002;124:333-339
© 2002 The American Association for Thoracic Surgery


Surgery for Acquired Cardiovascular Disease (ACD)

European experience with the Mosaic bioprosthesis

Walter Benno Eichinger, MDa, Florian Botzenhardta, Ralf Gunzinger, MDa, Bernhard M. Kemkes, MDa, Andrzej Sosnowski, MDb, Dominique Maïza, MDc, Eduardo Otero Coto, MDd, Niels Bleese, MDe

From Krankenhaus München Bogenhausen, München, Germanya; Glenfield General Hospital, Leicester, United Kingdomb; CHR Cote De Nacre, Caen, Francec; Clinico Universitario, Valencia, Spaind; and Albertinen Krankenhaus, Hamburg, Germany.e

Received for publication Sept 6, 2001. Revisions requested Nov 20, 2001; revisions received Dec 14, 2001. Accepted for publication Dec 18, 2001. Address for reprints: Walter B. Eichinger, MD, Deutsches Herzzentrum München, Department of Cardiovascular Surgery, Lazarettstrasse 36, D-80636, München, Germany (E-mail: eichinger{at}dhm.mhn.de).


    Abstract
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
Objective: The purpose of this study was to prospectively evaluate the clinical and hemodynamic performance of the Mosaic bioprosthesis (Medtronic, Inc, Minneapolis, Minn).
Methods: The stented porcine bioprosthesis combines the amino-oleic acid antimineralization treatment and the zero-pressure differential fixation technique for improved tissue durability. From February 1994 to May 1999, a total of 561 patients underwent valve replacement with the Mosaic bioprosthesis at 5 centers in Europe: 461 in the aortic and 100 in the mitral position. There were 261 women and 300 men; mean age at implantation was 70 years (range, 23-89 years). Mean follow-up was 2.9 years (range, 0-6.2 years), with a total follow-up of 1710.1 patient-years.
Results: Postoperative mortality was 4.2% per patient-year, including a valve-related mortality of 0.4% per patient-year. The freedom from event rates in the aortic position at 5 years and in the mitral position at 4 years were, respectively, 96.6% ± 1.1% and 94.9% ± 3.3% for primary thromboembolism, 96.4% ± 5.0% and 87.1% ± 4.8% for antithromboembolic-related hemorrhage, 99.1% ± 0.5% and 100% for thrombosed prosthesis, 98.8% ± 1.2% and 100% for structural valve deterioration, 98.8% ± 0.7% and 100% for nonstructural dysfunction, 98.4% ± 0.6% and 94.4% ± 3.8% for endocarditis, and 95.4% ± 1.6% and 95.3% ± 3.7% for explant and reoperation. Mean pressure gradient values at 5 years ranged from 7.5 to 15.9 mm Hg in the aortic position and at 4 years from 2.0 to 6.9 mm Hg in the mitral position across all valve sizes.
Conclusions: Clinical and hemodynamic performance of the Mosaic bioprosthesis were very satisfactory during the first 6 years after clinical introduction.


    Introduction
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
The Mosaic bioprosthesis (Medtronic Inc, Minneapolis, Minn) is a porcine heart valve with a low-profile stent fixed with glutaraldehyde combining zero-pressure and root-pressure techniques and treated with {alpha}-amino-oleic acid (AOA) to reduce tissue calcification. This European multicenter study was intended to evaluate the hemodynamic and clinical performance of the Mosaic valve in the aortic and mitral positions within the first 6 years after clinical introduction in 1994.


    Patients and methods
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
This prospective, nonrandomized, multicenter clinical trial of the Mosaic bioprosthesis began in February 1994. Patients given a diagnosis of valvular heart disease who required replacement of their aortic or mitral heart valve were eligible to enter the study. Patients undergoing concomitant procedures and those having active endocarditis at the time of implantation were entered into the study. Patients who required concomitant valve replacement or who already had a preexisting prosthetic valve in another position were excluded from enrollment. The study was approved by the respective institutional ethics committees, and all patients gave informed consent to participate. The study was supported by Medtronic, Inc, the manufacturer of the Mosaic bioprosthesis.

Until May 2000, a total of 461 patients (268 male and 193 female patients) underwent isolated aortic valve replacement (AVR) and 100 patients (32 male and 68 female patients) underwent isolated mitral valve replacement (MVR) with the Mosaic bioprosthesis. The age at implantation ranged from 23 to 89 years (mean, 70 years) in the aortic group and from 41 to 84 years (mean, 69 years) in the mitral group. Table 1 summarizes the preoperative and operative data.


View this table:
[in this window]
[in a new window]
 
Table 1. Preoperative and operative data
 
Valve replacement was undertaken by means of standard cardiopulmonary bypass at mild hypothermia with cold crystalloid cardioplegia. When the size of the bioprosthesis is being assessed, it is important to use the manufacturer-supplied Mosaic sizer. Because of the possibility of the so-called Supra-x placement, the specific construction of the Mosaic sizer and of the bioprosthesis often allow the implantation of a one-size-larger valve compared with the conventional supra-annular placement. This makes a significant increase in the effective flow orifice possible, as mentioned previously.Go 1

The clinical follow-up was done during the initial hospitalization for valve replacement, 6 months after the operation, and at annual intervals. The examination included a hematologic check and a hemodynamic assessment by means of transthoracic echocardiography. Mean systolic pressure gradients were calculated with the modified Bernoulli equation. Effective orifice areas were calculated with the continuity equation:
AVR = [(LVOTDiameter2 x 0.785 x TVILVOT)/TVIAortic Valve]
and
MVR = [(LVOTDiameter2 x 0.785 x TVILVOT)/TVIMitral Valve]
with LVOT defined as left ventricular outflow tract and TVI defined as time velocity integral.

Prosthetic insufficiency was graded on the basis of color Doppler assessment as mild, moderate, or severe. The echocardiographic examination has been documented in detail previously.Go 2

In the aortic group 3.7% (n = 17) and in the mitral group 2.0% of the patients (n = 2) were lost to follow-up. The mean follow-up was 3.2 years (range, 0-6.2 years) in the aortic and 2.6 years (range, 0-6.1 years) in the mitral position. The total follow-up included 1453.9 patient-years in the aortic group and 256.2 patient-years in the mitral group, respectively.

The guidelines of the Society of Thoracic Surgeons and The American Association of Thoracic Surgeons were followed for the reporting of mortality and valve-related morbidity.Go 3 Linearized complication rates were calculated by dividing the number of events by the sum of patient-years expressed as a percentage. Survival analyses with the Kaplan-Meier product-limit method were used to estimate survival and the freedom from valve-related adverse events.


    Results
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
Hemodynamic evaluation
In Table 2 the echocardiographically obtained mean pressure gradients and effective orifice areas of the different valve sizes are depicted.


View this table:
[in this window]
[in a new window]
 
Table 2. Echocardiographic data
 
Postoperative echocardiographic examination revealed prosthetic regurgitation in 7.6% of the patients after AVR (34/449, 31 mild and 3 moderate) and in 4.0% (4/100, all mild) of the patients after MVR. The regurgitation was transvalvular in 11 (all mild), paravalvular in 17 (15 mild and 2 moderate), and indeterminate (ie, not assessable by the echocardiographer) in 6 (5 mild and 1 moderate) patients in the aortic group and transvalvular and paravalvular each in 2 patients in the mitral group. Six years after implantation of the Mosaic bioprosthesis, 11.1% (2/18, 1 mild and 1 moderate, both transvalvular) of the aortic patient group and no patients in the mitral group showed prosthetic insufficiency.

Prosthetic valve-related adverse events
The actuarial rates of freedom from prosthetic valve-related adverse events and the linearized frequencies are shown in Table 3.


View this table:
[in this window]
[in a new window]
 
Table 3. Freedom from prosthetic valve-related adverse events
 
Mortality
The early mortality (ie, <30 days after the operation), if the patient was discharged from the hospital or at any time after implantation if the patient was not discharged from the hospital, was 2.4% for the aortic group and 1.0% for the mitral group. The late mortality (ie, >30 days after the operation), if the patient was discharged from the hospital, was 11.8% with a linearized rate of 3.7% per patient-year in the aortic group (on the basis of 1416.6 late patient-years) and 9.1% with a linearized rate of 3.6% per patient-year in the mitral group (on the basis of 248.1 late patient-years), respectively, including valve-related mortality of 0.5% per patient-year in the aortic group (n = 7) and 0.4% per patient-year in the mitral group (n = 1).

The Kaplan-Meier survival functions after AVR and MVR with the Mosaic bioprosthesis are depicted in Figure 1.



View larger version (31K):
[in this window]
[in a new window]
 
Fig. 1. Survival function: Top, After AVR; bottom, after MVR.

 
Clinical improvement
Before implantation of the Mosaic bioprosthesis, 79.0% of the patients with aortic valve lesions and 81.0% of those with mitral valve lesions were classified in New York Heart Association (NYHA) classes III and IV. Six months after the operation 98.4% in the aortic group and 94.7% in the mitral group were classified in NYHA classes I and II; 6 years after the operation 100% of the patients in both groups were so classified. Comparing preoperative state and results of the 1-year evaluation, 91.0% of the patients in the aortic group and 83.0% of those in the mitral group had an improvement in NYHA classification.


    Discussion
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
The Mosaic bioprosthesis is a stented porcine heart valve designed to minimize the biomodal failure mechanisms of bioprostheses, mechanical wear, and chemically induced intrinsic mineralization by means of the combination of several technologies. It is fitted to a low-profile acetal polymer stent, which is covered with polyester fabric. The prosthetic tissue is treated with glutaraldehyde to minimize the consequences of antigenicity after porcine valve implantation.Go 4 The fixation of the Mosaic bioprosthesis is a combination of the so-called zero-pressure and root-pressure methods: equal pressure is applied to the inflow and outflow ends of the valve. By this method, the aortic root is pressurized to maximize the flow area, and no pressure is exerted on the leaflets. The natural shape generally is preserved, and the disadvantages of low- and high-pressure fixation (ie, the changed arrangement of collagen and elastic fibers in the porcine leaflets that leads to altered tissue extensibility and pliability) can be reduced.Go Go 5,6 The bioprosthetic tissue is treated with AOA to mitigate chemical calcification. AOA is strongly bound to the tissue by forming Schiff base covalent linkages with aldehydes remaining from the fixation with glutaraldehyde. Chen and associatesGo 7 and Duarte and coworkersGo 8 proved the effective retardation of calcium ion diffusion into the tissue by means of AOA. Long-term results will show whether the anticalcific competence of the treatment with AOA is effective.

Aortic position
The mean systolic pressure gradients are very low (ie, 7.5 to 15.9 mm Hg across all sizes). Comparing these results with those with other established stented bioprostheses, the Mosaic performance is equivalent to that of the Hancock modified orifice II bioprosthesisGo 2 (Medtronic) and the Carpentier-Edwards pericardial valve (Edwards Lifesciences, Irvine, Calif),Go 9 with the larger sizes (27 and 29 mm) showing excellent hemodynamic function. Our results corresponded to the data published by Thomson and colleaguesGo 10 and Wong and associatesGo 11 in other Mosaic studies. Because the construction and implantation of stentless bioprostheses comprise a different technique, a direct comparison of the hemodynamic performance would be flawed. However, generally these Mosaic results approach the results obtained with stentless devices: Yun and coworkersGo 12 reported mean systolic pressure gradients of the Freestyle bioprosthesis of 6.7 ± 3.4 mm Hg (21 mm), 2.9 ± 2.3 mm Hg (23 mm), 3.7 ± 2.6 mm Hg (25 mm), and 6.0 ± 4.2 mm Hg (27 mm) after 4 years, and Westaby and associatesGo 13 showed Freestyle results 6 months after the operation of 9.2 ± 3.3 mm Hg (21 mm), 5.2 ± 2.3 mm Hg (23 mm), 4.3 ± 2.0 mm Hg (25 mm), and 4.0 ± 1.9 mm Hg (27 mm). Mohr and coworkersGo 14 described mean systolic pressure gradients of the Toronto SPV bioprosthesis (St Jude Medical, Inc, St Paul, Minn) of 11.1 mm Hg (21 mm and 23 mm), 8.4 mm Hg (25 mm), 8.9 mm Hg (27 mm), and 7.7 mm Hg (29 mm) 1 week after the operation.

The effective orifice areas of the Mosaic bioprosthesis after 5 years (1.6-3.0 cm2 across all sizes) are also very satisfactory. Our results corresponded to the measurements obtained during other Mosaic studies.Go Go 11,15 They exceed the results of Hancock modified orifice II,Go 2 Carpentier-Edwards Perimount,Go 9 and Medtronic Intact.Go 16 Again, under consideration of the different conditions of stented and stentless bioprostheses, the 23-mm (2.16 ± 0.65 cm2), 25-mm (2.38 ± 1.17 cm2), and 27-mm (2.70 ± 0.73 cm2) Freestyle valves in the series of Yun and colleaguesGo 12 4 years after the operation exceeded our Mosaic results, whereas the Freestyle study of Dumesnil and coworkersGo 15 1 year after the operation revealed lower effective orifice areas in comparison with these Mosaic results (21 mm, 1.35 ± 0.21 cm2; 23 mm, 1.48 ± 0.33 cm2; 25 mm, 2.00 ± 0.39 cm2; 27 mm, 2.32 ± 0.48 cm2).

As a limitation of the hemodynamic comparisons, it has to be stated that the sizes of the bioprostheses were taken over by the definitions given by each manufacturer. The fact that the manufacturers have chosen to size their prostheses in different ways can complicate the comparisons of pressure gradients and effective orifice areas because a 23-mm prosthesis of one manufacturer's type may not fit the same anulus as a 23-mm prosthesis from another manufacturer. This complication should be minimized in further studies by grouping the valves according to the intraoperative measured anulus instead of the manufacturer's description. In this study the measurements are also referred to the manufacturer's valve size and not to the patients' anulus. The actuarial freedom rates from valve-related adverse events after 5 years are satisfactory. The low incidence of structural valve deterioration, endocarditis, thromboembolism, and nonstructural valve dysfunction was especially convincing. The causes of valve-related death were antithromboembolism-related hemorrhage, valve thrombosis, reoperation for valve thrombosis (the patient died of multiorgan failure 2 days after reoperation), and reoperation for structural valve deterioration each in 1 patient and cerebrovascular attack in 3 patients. The cause of the relatively high rate of antithromboembolism-related hemorrhage (freedom after 5 years, 96.4% ± 0.9%; linearized rate, 0.8% per patient-year) might be found in the high quota of patients in the aortic group receiving anticoagulants throughout the 6 postoperative years (61.5% in the 5-year follow-up). The majority (50.7%) took acetylsalicylic acid (100 mg/d), which was indicated because of coronary artery disease. Some patients (10.8%) constantly received warfarin for reasons like atrial fibrillation and left atrial and ventricular dilation and dysfunction. There certainly were some patients taking warfarin without any reasonable indication but because of missing information from the general practitioner about the need for anticoagulation in patients with heart valve bioprostheses. Combinations of different types of anticoagulants (warfarin, heparin, acetylsalicylic acid, and ticlid) were seen in 14.6% of all patients only during the early postoperative period. The freedom rates from reoperation and explantation of the Mosaic bioprosthesis (95.4% ± 1.6% after 5 years; linearized rate, 0.8% per patient-year) are average results when compared with those of other bioprostheses. The reason for reoperation was primary valve thrombosis in 4 patients, endocarditis in 4 patients, primary paravalvular leak in 2 patients, and nonstructural valve dysfunction and structural valve deterioration each in 1 patient.

Mitral position
The hemodynamic performance of the Mosaic bioprosthesis in the mitral position is satisfactory. The mean diastolic pressure gradients after 4 years ranged from 2.7 to 6.0 mm Hg across all sizes. Lemieux and associatesGo 16 reported pressure gradients of the Intact valve in the mitral position 1 year after the operation of 6.18 ± 2.60 mm Hg (25 mm), 5.04 ± 1.86 mm Hg (27 mm), 4.69 ± 1.73 mm Hg (29 mm), and 3.28 ± 0.67 mm Hg (31 mm). The Carpentier-Edwards pericardial valve showed pressure gradients of 4.1 mm Hg (27 mm) and 3.0 mm Hg (29-33 mm) in a 10-year series by Aupart and colleagues.Go 17 The effective orifice areas of the Mosaic bioprostheses in the mitral position are quite small (1.5-2.6 cm2 across all sizes at 4 years) compared with those of other biologic valves. The Intact valve showed effective orifice areas of 1.85 ± 0.43 cm2 (25 mm), 1.93 ± 0.39 cm2 (27 mm), 2.33 ± 0.39 cm2 (29 mm), and 2.10 ± 0.26 cm2 (31 mm) 1 year after the operation.Go 16 Aupart and coworkersGo 17 described effective orifice areas of 2.6 cm2 (27 mm), 2.7 cm2 (29 mm), 2.6 cm2 (31 mm), and 3.1 cm2 (33 mm) for the Carpentier-Edwards pericardial valve. There is no obvious explanation for the small Mosaic effective orifice areas in the mitral position, and thus this finding should be critically observed in future studies. The actuarial freedom rates from valve-related adverse events in the mitral position 4 years after implantation show good results: there were no incidences of structural valve deterioration and nonstructural valve dysfunction and a low rate of thromboembolism and valve-related death. Causes of valve-related death were antithromboembolic-related hemorrhage and permanent neurologic event, each in 1 patient. Endocarditis was present in 2 patients, resulting in a low rate of freedom of 94.4% ± 3.8% after 4 years. Because the second incidence occurred during the fourth postoperative year with only 19 patients included in the 4-year follow-up period, the method of Kaplan-Meier estimates, which is based on the number of patients at risk, might have contributed to the unsatisfactory result. The same cause might underlie the relatively low freedom from reoperation and explantation (95.3% ± 3.7% after 4 years) because the 2 valves affected by endocarditis caused the only 2 reoperations and explantations. The relatively low freedom from antithromboembolism-related hemorrhage might be attributed to the high rate of patients in the mitral group receiving anticoagulants postoperatively: 82.5% in the 4-year follow-up period (56.5% for warfarin, 17.4% for acetylsalicylic acid, 4.3% for ticlid, and 4.3% for warfarin and acetylsalicylic acid). Coronary artery disease was the main indication for acetylsalicylic acid (100 mg/d) and ticlid. Left atrial and ventricular enlargement and atrial fibrillation as results of the mitral lesion were the indications for warfarin. Again, the missing knowledge of the general practitioner about the thrombogenicity of bioprostheses might attribute to the high rate of constant warfarin recipients.


    Conclusion
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
In conclusion, the Mosaic bioprosthesis, both in the aortic and in the mitral position, showed very good hemodynamic performance in comparison with that of other stented bioprostheses. Compared with other biologic valves, the freedom from prosthetic valve-related adverse events was very satisfactory. Further investigation and data collection will be necessary to determine long-term results and to decide on the device's inferiority or superiority compared with that of established heart valve devices.


    Footnotes
 
Medtronic, Inc (Minneapolis, Minn), provided financial support to the listed departments to defray research expenses. Back


    References
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 

  1. Eichinger WB, Guenzinger R, Botzenhardt F, Simmerl D, Gansera B, Kemkes BM. The Mosaic bioprosthesis in the aortic position at five years. J Heart Valve Dis. 2000;9:653-60.[Medline]
  2. Eichinger WB, Schütz A, Simmerl D, Gansera B, Breuer M, Haslinger B, et al. The Mosaic bioprosthesis in the aortic position: hemodynamic performance after 2 years. Ann Thorac Surg. 1998;66:S126-9.
  3. Edmunds LH, Clark RE, Cohn LH, Grunkemeier GL, Miller CM, Weisel RD. Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ann Thorac Surg. 1996;62:932-5.[Abstract/Free Full Text]
  4. Carpentier A, Lemaigre G, Robert L, Carpentier S, Dubost C. Biological factors affecting long-term results of valvular heterografts. J Thorac Cardiovasc Surg. 1969;58:467-83.[Medline]
  5. Vesley I. Analysis of the Medtronic Intact bioprosthesis valve. Effects of "zero-pressure" fixation. J Thorac Cardiovasc Surg. 1991;101:90-9.[Abstract]
  6. Vesley I, Lozon A, Talman E. Is zero-pressure fixation of bioprosthetic valves truly stress free? J Thorac Cardiovasc Surg. 1993;106:288-98.[Abstract]
  7. Chen W, Schoen FJ, Levy RJ. Mechanism of efficacy of 2-amino oleic acid for inhibition of calcification of glutaraldehyde-pretreated porcine bioprosthetic heart valves. Circulation. 1994;90:323-9.[Abstract/Free Full Text]
  8. Duarte IG, MacDonald M J, Cooper WA. In vivo hemodynamic, histologic and antimineralization characteristics of the Mosaic bioprosthesis. Ann Thorac Surg. 2001;71:92-9.[Abstract/Free Full Text]
  9. Aupart MR, Neville P, Dreyfus X, Meurisse Y, Sirinelli A, Marchand M. The Carpentier-Edwards pericardial aortic valve: intermediate results in 420 patients. Eur J Cardiothorac Surg. 1994;8:277-80.[Abstract]
  10. Thomson D, Jamieson WRE, Dumesnil J, Busse E, Peniston C, Mbtras J, et al. Medtronic Mosaic porcine bioprosthesis satisfactory early clinical performance. Ann Thorac Surg. 1998;66:122-5
  11. Wong SP, Legget ME, Greaves SC, Barratt-Boyes BG, Milsom FP, Raudkivi PJ. Early experience with the Mosaic bioprosthesis: a new generation porcine valve. Ann Thorac Surg. 2000;69:1846-50.[Abstract/Free Full Text]
  12. Yun KL, Sintek CF, Fletcher AD, Pfeifer TA, Kochamba GS, Hyde MR, et al. Aortic valve replacement with the Freestyle stentless bioprosthesis: five-year experience. Circulation. 1999;100(suppl):II-17-23.
  13. Westaby S, Amarasena N, Long V, Prothero A, Amarasena GA, Banning AP, et al. Time-related hemodynamic changes after aortic replacement with the Freestyle stentless xenograft. Ann Thorac Surg. 1995;60:1633-8.[Abstract/Free Full Text]
  14. Mohr FW, Walther T, Baryalei M, Falk V, Autschbach R, Scheidt A, et al. The Toronto SPV bioprosthesis: one-year results in 100 patients. Ann Thorac Surg. 1995;60:171-5.[Abstract/Free Full Text]
  15. Dumesnil J, LeBlanc MH, Cartier P, Métras J, Desaulniers D, Doyle D, et al. Hemodynamic features of the Freestyle aortic bioprosthesis compared with stented bioprosthesis. Ann Thorac Surg. 1998;66:S130-3.
  16. Lemieux MD, Jamieson WRE, Landymore RW, Dumesnil JG, Metras J, Munro Al, et al. Medtronic Intact porcine bioprosthesis: Clinical performance to seven years. Ann Thorac Surg. 1995;60:258-63.
  17. Aupart MR, Neville PH, Hammami S, Sirinelli AL, Meurisse YA, Marchand MA. Carpentier-Edwards pericardial valves in the mitral position: ten-year follow-up. J Thorac Cardiovasc Surg. 1997;113:492-8.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
CirculationHome page
D. J. Ruzicka, I. Hettich, A. Hutter, S. Bleiziffer, C. C. Badiu, R. Bauernschmitt, R. Lange, and W. B. Eichinger
The Complete Supraannular Concept: In Vivo Hemodynamics of Bovine and Porcine Aortic Bioprostheses
Circulation, September 15, 2009; 120(11_suppl_1): S139 - S145.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. Pibarot and J. G. Dumesnil
Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Circulation, February 24, 2009; 119(7): 1034 - 1048.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Guenzinger, W. B. Eichinger, I. Hettich, S. Bleiziffer, D. Ruzicka, R. Bauernschmitt, and R. Lange
A prospective randomized comparison of the Medtronic Advantage Supra and St Jude Medical Regent mechanical heart valves in the aortic position: is there an additional benefit of supra-annular valve positioning?
J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 462 - 471.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
T. Gudbjartsson, T. Absi, and S. Aranki
Mitral Valve Replacement
Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068.
[Full Text]


Home page
ICVTSHome page
M. J. Dalmau, J. Maria Gonzalez-Santos, J. Lopez-Rodriguez, M. Bueno, A. Arribas, and F. Nieto
One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: a prospective randomized study
Interactive CardioVascular and Thoracic Surgery, June 1, 2007; 6(3): 345 - 349.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. Nowell, E. Wilton, H. Markus, and M. Jahangiri
Antithrombotic therapy following bioprosthetic aortic valve replacement
Eur. J. Cardiothorac. Surg., April 1, 2007; 31(4): 578 - 585.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Magne, P. Mathieu, J. G. Dumesnil, D. Tanne, F. Dagenais, D. Doyle, and P. Pibarot
Impact of Prosthesis-Patient Mismatch on Survival After Mitral Valve Replacement
Circulation, March 20, 2007; 115(11): 1417 - 1425.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. A. Weber, J. Jouan, A. Matsunaga, E. Pettenazzo, T. Joudinaud, G. Thiene, and C. M.G. Duran
Evidence of mitigated calcification of the Mosaic versus Hancock Standard valve xenograft in the mitral position of young sheep.
J. Thorac. Cardiovasc. Surg., November 1, 2006; 132(5): 1137 - 1143.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Guenzinger, W. B. Eichinger, F. Botzenhardt, S. Bleiziffer, I. Wagner, R. Bauernschmitt, S. M. Wildhirt, and R. Lange
Rest and Exercise Performance of the Medtronic Advantage Bileaflet Valve in the Aortic Position
Ann. Thorac. Surg., October 1, 2005; 80(4): 1319 - 1326.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
F. Botzenhardt, W. B. Eichinger, S. Bleiziffer, R. Guenzinger, I. M. Wagner, R. Bauernschmitt, and R. Lange
Hemodynamic Comparison of Bioprostheses for Complete Supra-Annular Position in Patients With Small Aortic Annulus
J. Am. Coll. Cardiol., June 21, 2005; 45(12): 2054 - 2060.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
W. B. Eichinger, F. Botzenhardt, A. Keithahn, R. Guenzinger, S. Bleiziffer, I. Wagner, R. Bauernschmitt, and R. Lange
Exercise hemodynamics of bovine versus porcine bioprostheses: A prospective randomized comparison of the mosaic and perimount aortic valves
J. Thorac. Cardiovasc. Surg., May 1, 2005; 129(5): 1056 - 1063.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
S. H. Daebritz, B. Fausten, B. Hermanns, J. Schroeder, J. Groetzner, R. Autschbach, B. J. Messmer, and J. S. Sachweh
Introduction of a flexible polymeric heart valve prosthesis with special design for aortic position
Eur. J. Cardiothorac. Surg., June 1, 2004; 25(6): 946 - 952.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. Seitelberger, J. Bialy, R. Gottardi, G. Seebacher, R. Moidl, M. Mittelbock, P. Simon, and E. Wolner
Relation between size of prosthesis and valve gradient: comparison of two aortic bioprosthesis
Eur. J. Cardiothorac. Surg., March 1, 2004; 25(3): 358 - 363.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. H. Daebritz, J. S. Sachweh, B. Hermanns, B. Fausten, A. Franke, J. Groetzner, B. Klosterhalfen, and B. J. Messmer
Introduction of a Flexible Polymeric Heart Valve Prosthesis With Special Design for Mitral Position
Circulation, September 9, 2003; 108(90101): II-134 - 139.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Walter Benno Eichinger
Bernhard M. Kemkes
Niels Bleese
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eichinger, W. B.
Right arrow Articles by Bleese, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eichinger, W. B.
Right arrow Articles by Bleese, N.
Related Collections
Right arrow Valve disease


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS