J Thorac Cardiovasc Surg 2002;124:999-1006
© 2002 The American Association for Thoracic Surgery
Surgery for Congenital Heart Disease (CHD) |
From the Heart Institute University of São Paulo Medical School, São Paulo, Brazil.
Read at the 9th Biennial Meeting of the Society of Pediatric Cardiovascular Surgery Aldo R. Castañeda, Boston, Mass, April 2000.
Received for publication Oct 18, 2001. Revisions requested Jan 2, 2002; revisions received Feb 8, 2002. Accepted for publication Feb 16, 2002. Address for reprints: Renato Assad, MD, Heart Institute University of São Paulo, Division of Surgery, Ave Dr Eneas de Carvalho Aguiar, 44, São Paulo, SP 05403-000, Brazil (E-mail: rsassad{at}cardiol.br).
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
|
We still have a considerable number of patients with late referral for the Jatene operation. However, we were not able to reproduce the excellent Boston experience of rapid left ventricular (LV) preparation,
4 probably related to the lack of pulmonary trunk (PT) banding adjustment, which has been done empirically. The degree of PT banding might be inadequate or imprecise, causing an important acute systolic overload on the left ventricle, which in turn would impair late ventricular function.
5-8
We developed an experimental model designed to adjust PT banding percutaneously and to induce rapid pulmonary ventricular hypertrophy. The RV changes caused by the PT banding device were evaluated according to hemodynamic, echocardiographic, and morphologic aspects after 96 hours of uninterrupted gradual systolic overload.
| Materials and methods |
|---|
|
|
|---|
PT banding device
Figure 1 shows the 3 components of the banding device: banding ring, extension tube, and insufflation button. The banding ring (Hazen Everett Co) is a U-shaped hydraulic cuff with a 10-mm internal diameter and a 5-mm width. Its outer layer consists of 1-mm-thick rigid silicone, which keeps it from deforming. The inner surface has a deformable layer of silicone, which expands, compressing the lumen of the vessel according to the volume injected into the inflation button. At the 2 ends of the cuff, there are small orifices that are used for securing the ring to the PT. The extension tube, also made of silicone, links the banding ring with the insufflation button. It has a 2-mm inner diameter and is 25 cm long. The inflation button (Bard Access System) is a circular reservoir made of self-sealing silicone, the base of which includes a metal plate. The reservoir has a port, which is connected to the extension tube. This button is implanted subcutaneously, thus permitting the inflation or deflation of the banding ring percutaneously.
|
Echocardiographic studies
All examinations included 2-dimensional and M-mode echocardiographic imaging of the ventricles from the right parasternal view with 2.5- and 5-MHZ transducers (Ultramark 4, Advanced Technology Laboratories). Initial evaluation confirmed a RV free wall thickness smaller than that of the left ventricle. Postoperative evaluation of induced hypertrophy was performed with intervals of 24 hours. The following parameters were observed: (1) RV, LV, and septal wall thicknesses; (2) RV/PT pressure gradient; and (3) presence of effusions.
Protocol
All animals received humane care in compliance with the "Principles of Laboratory Animal Care" formulated by the National Society for Medical Research and the "Guide for the Care and Use of Laboratory Animals" prepared by the National Academy of Sciences and published by the National Institutes of Health. Digoxin was given to all goats (0.5 µg · kg-1 · d-1 administered intramuscularly). The inflation protocol of progressive RV systolic overload was begun after full surgical recovery. After taking baseline pressure measurements, the PT banding device was initially inflated by means of percutaneous injection of saline solution with a 1-mL syringe under sterile conditions to achieve a 0.7 RV/LV systolic pressure ratio, as long as it did not cause more than a 10% systemic pressure drop. The amount of water used for cuff inflation varied from 0.1 to 0.4 mL. The volume in the banding device was progressively incremented at 24-hour intervals, according to animal tolerance to the pressure load. If systemic hypotension, respiratory distress, or both developed after inflation of the banding device, it was deflated to the previous volume compatible with maintenance of goat hemodynamics. Hemodynamic evaluation was performed every 24 hours. The RV systolic overload was carried out for 96 hours. The animals were then killed for morphologic evaluation of the heart.
Morphologic studies
Baseline myocardial samples (3 mm maximal diameter) from the subepicardial layer of the RV outflow tract were collected for optical microscopic studies just before catheter insertion. After 96 hours of RV systolic overload, the animals were killed, and the positions of the catheters were checked in the right ventricle, PT, and aorta. The hearts were then removed from the thorax. Similarly, the control group animals were also killed to measure the ventricular and septal weights.
Weight determinations
The ventricular and septal weights were taken according to the Fulton technique (METTLER AE-200, Mettler-Toledo AG).
9 The weight measurements were indexed to the body weight of the animal (in grams per kilogram), as suggested by Bishop and Cole.
10
Optical microscopy
After weight measurements, the hearts were fixed in 10% buffered formalin for 24 hours. A transverse cut of the ventricular mass was made 1 cm below the level of the atrioventricular junction. Sections from the ventricular septum, right ventricle, and left ventricle were obtained. After routine histologic processing, 5-µm sections were stained with hematoxylin and eosin. The perimeter and area of transversely sectioned cardiomyocytes were measured at the level of the nucleus by means of an image analysis system (Quantimet-Leica, Leica Cambridge Ltd) at a magnification of 400x. Data were collected from 140 myocytes of baseline samples and from 105 myocytes of the ventricles subjected to 96 hours of RV systolic overload.
Statistical analysis
Values are expressed as means ± SD. The paired Student t test was used to compare the baseline data with the 96-hour data of the RV systolic overload group under hemodynamic, echocardiographic, and optical microscopy aspects. The unpaired Student t test was used (GB-STAT, Dynamic Microsystems) to compare the septal and ventricular weights. The statistical significance was set at 5% level.
| Results |
|---|
|
|
|---|
Hemodynamic measurements
All the animals presented with tachycardia at the end of the protocol (baseline, 127.9 ± 12.5 beats/min; after 96 hours of systolic overload, 150.0 ± 8.7 beats/min; P = .003). We noticed a 13.6% decrease in the aortic systolic pressure during the protocol, although no changes in LV function were observed with echocardiography (P = .005).
After 96 hours of systolic overload, the right ventricle showed a 217.0% increase in systolic pressure, from 22.4 ± 4.1 mm Hg to 71.0 ± 10.0 mm Hg, surpassing the systolic pressure of the left ventricle (P = .0001). The RV/PT systolic gradient varied from 10.1 ± 4.3 mm Hg to 60.0 ± 11.0 mm Hg (P = .0001), whereas the RV/LV pressure ratio increased from 0.29 ± 0.06 (before RV systolic overload) to 1.04 ± 0.14 (after the 96-hour protocol, P = .0001). The hemodynamic data are summarized in Table 1.
|
|
|
Weight of the ventricles
The RV weight from the studied animals was 74% greater than that from the control group (0.99 ± 0.17 vs 1.72 ± 0.24 g/kg, P = .0001). There was no difference between the septal and LV weights from the studied animals compared with those in the control group. These weight measurements are summarized in Table 4.
|
|
|
| Discussion |
|---|
|
|
|---|
Critique of the preparation
This protocol analyzes some aspects of the acute RV hypertrophy in a young animal model. At the present time, it is not clear whether the response to the stimulus of the variable systolic overload on the subpulmonary ventricle of adult animals would be the same. In the clinical setting the hypertrophic response of the subpulmonary ventricle has been demonstrated to take a longer time. According to Mavroudis and Backer,
12 patients with TGA and failed atrial inversion aged from 1.9 to 23 years took an average of 15.6 months to retrain the subpulmonary ventricle for the 2-stage Jatene operation. Ongoing studies in our laboratory are assessing this protocol in an adult model. Blood oximetry changes induced by PT banding were not evaluated in this study. However, no clinical signs of significant hypoxia, acidosis, or both were observed. Although a more precise adjustment of RV systolic overload could be achieved, this model does not reflect the clinical reality of patients with TGA and a functionally intact ventricular septum. PT banding might not be tolerated in patients with significant hypoxia without a Blalock-Taussig shunt. Nevertheless, the adjustability of PT banding could favor a balanced interatrial shunt in patients with TGA, thus avoiding the Blalock-Taussig shunt. Furthermore, the device could be disinsufflated at any time if serious hypoxia occurs.
Historical notes
Some of the historical aspects conceptually related to our prototype are described here. The idea of an adjustable banding device composed of a hydraulic cuff and a self-sealing button was first proposed in 1957. In fact, Jacobson and McAllister
14 proposed a device that consisted of a rubber cuff with a lateral opening connected to a reservoir protected by self-sealing rubber. It was used on the great vessels of dogs, aiming at a congestive heart failure model. Complications in handling the device were observed. In 1969, Bishop and Cole
10 improved Jacobson and McAllister's device by covering the cuff with silicone, with the aim of reducing local tissue reaction. They induced RV hypertrophy and congestive heart failure in a dog model. In 1972, Edmunds and associates
15 introduced 2 main changes: an external, nondeformable layer on the hydraulic cuff and use of silicone instead of rubber. However, they observed asymmetric inflation or rupture of the cuff, and leakage of the injected material prevented clinical use. In 1985, a new device made of biologically stable material (medical grade silicone) was introduced by Park and colleagues.
16 The cuff was covered with reinforced braid and coated with silicone. The self-sealing button had a silicone diaphragm that did enable repeated needle puncture, avoiding leakage through the button. The device implanted in dogs and lambs was easily and effectively adjusted. In that same year, Solis and coworkers,
17 for the first time in the literature, proposed a similar device to the previous one that was intended to prepare the subpulmonary ventricle for the 2-stage Jatene operation. Nevertheless, when the system was submitted to a high gradient pressure, as in the systemic circulation, dilation of the reservoir and the connecting tube occurred. In addition, there was a tendency of the cuff to bulge laterally under high pressure. In another study the same group improved the strength of the material by reinforcing the cuff and the connecting tube with a spiral of 4-0 silk to withstand systemic arterial pressure.
18 Again, they experienced bulging of the cuff caused by a loosening silk. In our study the gradient imposed by the cuff was steady, and such deformation was not observed because of a rigid and thick cuff outer layer, which avoided centrifugal distortion when insufflated.
Echocardiographic aspects
In our protocol the calculated pressure gradients from Doppler velocities overestimated the directly measured gradients from implanted catheters. This situation could be compared with the Venturi effect, which allows almost complete pressure recovery after the stenotic area at the vena contracta. Our data are corroborated by the in vitro studies of Levine and associates,
19 which have demonstrated a greater poststenotic pressure recovery, measured directly with a catheter, related to the extent of the obstruction, which in turn lowers the pressure gradient. These data suggest an important advantage for Doppler gradient estimation, which uses the peak velocity and provides the maximum gradient at the vena contracta, which determines the load imposed on the proximal chamber.
Morphologic aspects
The important increase in the overloaded RV weight could reflect an increase in water content of the myocardium. Under microscopic analysis, however, there was no evidence of significant edema or interstitial fibrosis. Studies by Katayama and coworkers
20 showed that the increase in the ventricular weight subjected to a 4-day period of intermittent systolic overload was associated with an increase in the dry weight of the myocardium, relating such findings to hypertrophy of the cardiac myocyte rather than edema. However, the magnitude of hypertrophy needed for the Jatene operation remains unclear. Regarding the microscopic analysis, the myocyte perimeter and area measurements at the level of the nucleus are based on the studies of Anversa and colleagues.
21 These authors analyzed cardiac myocytes of rats subjected to 20 hours of constriction of the abdominal aorta. It was noted that in addition to the increase in the protein synthesis in the myocytes, there was a 20% increase in their area. During a longer period (13 days) of similar systolic overload, those authors found an increase of more than 200% in the average cross-sectional area of the cardiac myocytes of rats.
22 Data obtained in our laboratory
23 using a balloon catheter to induce the RV hypertrophy of young goats for a variable period of 9 to 20 days showed a 20% increase in the diameter (not the area) of the cardiac myocytes. In the present study the 96 hours of RV systolic overload induced a 69% increase in the myocyte area, which was enough to generate systemic pressures in the right ventricle. Actually, the ideal time and way of preparing the subpulmonary ventricle for the 2-stage Jatene operation remains controversial. There is evidence that nongradual and abrupt banding, causing sudden and acute systolic overload, could induce significant damage to the myocardium. A subpulmonary ventricle training program in a fashion tailored to the ventricle response should be established similarly to a fitness program tailored to an athlete, as mentioned by Redington,
24 thus avoiding the pathologic hypertrophy. Therefore an adjustable banding device would be advantageous for optimal ventricular training.
Implications
In our protocol a 0.7 RV/LV pressure ratio, a maximum 10% decrease in systemic systolic pressure, or both were used as parameters for device inflation. Other authors have used subjective criteria, such as animal clinical condition or signs of RV failure. Clinically, other parameters to indicate primary correction of TGA include a systolic subpulmonary ventricular pressure of greater than 65 mm Hg
25 or an LV/RV systolic pressure ratio of greater than 0.75,
26 although Däbritz and associates
27 have performed primary Jatene operations in a series of 7 patients aged 4 weeks or older with a pulmonary/systemic pressure ratio of 0.2 to 0.5 after submitting a trial of PT banding to systemic pressure for 15 to 30 minutes. Previous studies from our laboratory have demonstrated an equalization of ventricular thickness over a short interval of 6 to 10 days of more gradual balloon inflation
24 compared with the 96-hour period of the systolic overload of the present study. It is noteworthy that some of the animals had systemic pressure in the subpulmonary ventricle with only 48 hours of systolic overload. However, Boutin and coworkers
5 associate the late LV dysfunction with an extremely acute overload in patients undergoing the 2-stage Jatene operation. Such dysfunction was inversely proportional to more rapid hypertrophy and to more serious dysfunction after PT banding. On the other hand, patients who present with systemic ventricular failure in corrected TGA or after failed atrial baffle operations almost always have associated tricuspid regurgitation. It is not clear whether this association is a cause or a consequence of ventricular failure. Different groups have demonstrated clinical recovery of RV function and resolution of tricuspid regurgitation after the 2-stage Jatene operation as an alternative to cardiac transplantation.
12,13,28,29 However, reoperations to tighten or loosen the band were necessary in some cases to prepare the left ventricle to tolerate systemic pressure. We believe that the adjustability of the hydraulic cuff might be more effective in training the subpulmonary ventricle in a shorter time, not only by avoiding reoperations for band adjustment but also by allowing the fine tuning of the systolic overload over that ventricle in response to a patient's hemodynamic status. Perhaps our model of variable and progressive systolic overload could favor a healthier hypertrophy of the subpulmonary ventricle when compared with the conventional stationary banding, in which the systolic stress is abrupt and constant. The gradual increase of the RV overload allowed not only progressive tolerance to the PT banding but also generated pressures even greater than that of the left ventricle after the training period. Future studies using molecular biology as a tool to assess markers of pathologic hypertrophy might compare several training programs for the subpulmonary ventricle. The main goal would be minimum cellular damage and maximum efficiency of the pulmonary banding.
Conclusion
The device proposed in this article is biocompatible and easily implanted. It was efficient in performing the adjustable PT banding percutaneously. The systolic overload imposed by the device enabled the rapid hypertrophy (96 hours) of the subpulmonary ventricles of the animals studied. This treatment might allow the preparation of the subpulmonary ventricle for the 2-stage Jatene operation not only in patients with TGA beyond the neonatal period but also in those who present with systemic ventricular failure in corrected TGA or after failed atrial baffle operations.
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
R. S. Assad, M. M. Zamith, M. F. Silva, P. G. Thomaz, L. A. Miana, V. C. Guerra, C. A. Pedra, and M. B. Marcial A Novel Adjustable Pulmonary Artery Banding System for Hypoplastic Left Heart Syndrome Ann. Thorac. Surg., December 1, 2007; 84(6): 2081 - 2084. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Pokreisz, G. Marsboom, and S. Janssens Pressure overload-induced right ventricular dysfunction and remodelling in experimental pulmonary hypertension: the right heart revisited Eur. Heart J. Suppl., December 1, 2007; 9(suppl_H): H75 - H84. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. C.D. Abduch, R. S. Assad, M. Q. Rodriguez, A. S. Valente, J. L. Andrade, L. M.M. Demarchi, M. B. Marcial, and V. D. Aiello Reversible pulmonary trunk banding III: Assessment of myocardial adaptive mechanisms--contribution of cell proliferation J. Thorac. Cardiovasc. Surg., June 1, 2007; 133(6): 1510 - 1516. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. F. Voelkel, R. A. Quaife, L. A. Leinwand, R. J. Barst, M. D. McGoon, D. R. Meldrum, J. Dupuis, C. S. Long, L. J. Rubin, F. W. Smart, et al. Right Ventricular Function and Failure: Report of a National Heart, Lung, and Blood Institute Working Group on Cellular and Molecular Mechanisms of Right Heart Failure Circulation, October 24, 2006; 114(17): 1883 - 1891. [Full Text] [PDF] |
||||
![]() |
A. F. Corno, D. Bonnet, N. Sekarski, D. Sidi, P. Vouhe, and L. K. von Segesser Remote control of pulmonary blood flow: initial clinical experience J. Thorac. Cardiovasc. Surg., December 1, 2003; 126(6): 1775 - 1780. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||