JTCS Tips for Better Browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Sidney Chocron
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chocron, S.
Right arrow Articles by Etievent, J.-P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chocron, S.
Right arrow Articles by Etievent, J.-P.
Related Collections
Right arrow Great vessels

J Thorac Cardiovasc Surg 2002;124:1239-1241
© 2002 The American Association for Thoracic Surgery


Brief Communications

Is endovascular stent grafting for descending thoracic aortic disease recommendable in patients with dysphagia?

Sidney Chocron, MD, PhDa, Lucian Stoica, MDa, Stephane Koch, MDb, Jean-François Bonneville, MDc, Djamel Kaili, MDa, Bruno Heyd, MD, PhDd, Joseph-Philippe Etievent, MDa Besançon, France.

From the Departments of Thoracic and Cardiovascular Surgery,a Gastroenterology,b Radiology,c and Surgery, Transplant Unit,d J. Minjoz Hospital, Besançon, France.

Received for publication Feb 20, 2002. Accepted for publication March 27, 2002. Address for reprints: Sidney Chocron, MD, PhD, Department of Cardiac Surgery, J. Minjoz Hospital, Besançon, France 25030 (E-mail: chocron{at}ufc-chu.univ-fcomte.fr).

Endoluminal stent graft repair is an alternative to conventional surgical intervention. Perioperative complications associated with the endoluminal technique are arterial injury, maldeployment, aortic perforation, left upper limb ischemia, and paraplegia. Secondary complications are leaking, graft migration, aortoesophageal fistula, and aortobronchial fistula.Go 1

There are various conditions associated with aortoesophageal fistula: foreign bodies, malignancy, primary fistula of thoracic aortic aneurysm, or secondary fistula after surgical repair of these aneurysms.Go 2 We report 2 cases of an uncommon condition: aortoesophageal fistula after stenting of a descending thoracic aneurysm and of a spontaneous aortic rupture with a periaortic hematoma.

Clinical summary

The first patient is a 79-year-old man whose medical history is limited to inguinal hernia repair. He presented with a persistent cough, left pulmonary hilar mass, progressive complete aphagia, and weight loss. Esophageal fiberoptic endoscopy revealed erosive lesions with alimentary residue in a midesophageal tumefaction area 30 cm from the dental arch. Biopsies were done and revealed nonspecific lesions. Computed tomographic (CT) scans performed for the left pulmonary hilar mass showed a 94-mm-diameter aortic aneurysm compressing the left main bronchus, the esophagus, and the left atrium (Figure 1). The aortogram showed a saccular aneurysm, 84 mm high and 94 mm wide in its largest portion, with a 30-mm postsubclavian neck.



View larger version (63K):
[in this window]
[in a new window]
 
Fig. 1. Patient 1: left, CT scan before aortic stenting; right, CT scan 45 days later, when the aortoesophageal fistula was diagnosed. Note the retraction of the aneurysm from 94 to 60 mm in diameter.

 
Because of the age and the general status of the patient, we opted for endovascular repair. The anatomy of the aneurysm and the aortoiliac arteries allowed the endovascular procedure.

A Talent endoluminal stent graft (World Medical Corp, Sunrise, Fla) was deployed through the right femoral artery. The cover part of the stent was 100 mm long and 34 mm wide. The proximal and distal edges of the graft were dilated with a 34-mm-diameter balloon for better stent expansion and exclusion of the aneurysm. There was no leaking and no adverse event at the time of the procedure.

The patient started to eat 10 days later and was discharged on day 14. Forty-five days later, he returned with anemia and melena. Over this period, the patient had eaten normally and gained weight. Injected CT scanning showed no leak, no stent migration, and no kinking. The aneurysm decreased to 60 mm in its widest part (Figure 1Go). Esophageal fiberoptic endoscopy revealed an aortoesophageal fistula on the posterior part of the middle third of the esophagus with a tissue loss 50 mm high and 30 mm wide, which allowed us to view the superior part of the endoprothesis. Because the patient's condition precluded another operation, we proposed palliative treatment. The lack of substance was covered by an esophageal prosthesis, but the patient still required one packed red cell unit transfusion per day. Finally, we complied with the patient's request to stop treatment and send him home. He died 10 days later.

The second case is a 59-year-old woman with a medical history of arterial hypertension, obesity, and smoking. She had persistent fever, asthenia, and dysphagia. The medical investigations for fever were not conclusive. Three weeks later she returned with dyspnea, left pleural effusion, fever, and aphagia. A CT scan, performed for suspicion of a pulmonary embolism, revealed a spontaneous aortic rupture with a periaortic hematoma compressing the esophagus and the left atrium (Figure 2).



View larger version (64K):
[in this window]
[in a new window]
 
Fig. 2. Patient 2: left, CT scan before aortic stenting; right, CT scan 7 days later, when the aortoesophageal fistula was diagnosed. Note the unchanged diameter of the periaortic hematoma.

 
The patient was immediately transferred to our unit, where we performed an endovascular covering of the aortic rupture by deploying a 25-mm-diameter Talent endoluminal stent graft. Because the right femoral artery was too small, we proceeded through the right common iliac artery. The procedure went well, with no leaking or adverse medullary effect. On day 7, the patient had a hematemesis. An upper esophageal fiberoptic endoscopy showed an aortoesophageal fistula 30 cm from the dental arch and an esophageal ulcer covered with clots (Figure 3). The injected CT scan revealed no leak, no stent migration, and no kinking and showed no regression of the periaortic hematoma (Figure 2Go). The aortoesophageal fistula was managed with esophagectomy with bilateral exclusion by means of right thoracotomy, cervical esophagostomy, and gastrostomy. The patient had a promising outcome in the early postoperative period but developed sepsis and died 2 months later.



View larger version (53K):
[in this window]
[in a new window]
 
Fig. 3. Fibroscopic views of the aortoesophageal fistula in patient 2.

 
Discussion

Aortoesophageal fistula is a well-known complication of descending thoracic aortic grafting.Go 3 Cases after esophagealGo Go 4,5 and bronchialGo 6 stenting have also been described. To the best of our knowledge, no case of aortoesophageal fistula after endovascular repair of descending thoracic aortic diseases has been reported to date. We report 2 cases of patients with aphagia at the time of diagnosis, evidenced by the compression of the esophagus by the aneurysm or the hematoma and confirmed by the CT scan.

The first patient had an upper esophageal fiberoptic endoscopy with biopsies before discovery of the aneurysm. Obviously, the biopsies might have facilitated the disclosure of the fistula, but the retraction of the aneurysm after exclusion worsened the fistula at the least. This hypothesis is supported by the 45-day interval between the operation and the apparition of the fistula.

The second patient had no upper esophageal fiberoptic endoscopy. In this case the fistula was most likely present at the time of the diagnosis. This is supported by 2 facts: (1) the short interval between aortic stenting and diagnosis of the fistula prevented retraction of the hematoma, and (2) the patient described having a rotting taste before being hospitalized. However, compression of the hematoma is likely to have worsened the fistula.

The development of the fistula cannot be linked to the specific stent graft used. In both cases the iterative injected CT scans showed no feature that could incriminate the device, and in particular, there was no evidence of aortic free wall rupture.

These 2 cases highlight the care one should take in proposing endovascular stenting in patients with dysphagia or aphagia. Compared with classic surgical intervention, endovascular stenting does not remove the periaortic hematoma or the intra-aneurysmal thrombosis, and hence the esophagus remains compressed after the procedure, thus allowing the ischemic lesions of the esophagus to develop. Moreover, this fragile ischemic zone is subject to mechanical aggression caused by the retraction of the aneurysm or the hematoma. The result is that a small fistula, which can recover with the removal of the compression, is likely to be worsened and enlarged by leaving compression to do its work.

Acknowledgments

We are grateful to Nancy Richardson-Peuteuil for her editorial assistance.

References

  1. Dake MD, Miller DC, Mitchell RS, et al. The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta. J Thorac Cardiovasc Surg. 1998;116:689-703.[Abstract/Free Full Text]
  2. Reardon MJ, Brewer RJ, Le Maire SA, et al. Surgical management of primary aortoesophageal fistula secondary to thoracic aneurysm. Ann Thorac Surg. 2000;69:967-70.[Abstract/Free Full Text]
  3. Wickstrom PH, Streitz JM, Erickson RV, et al. Repair of aortoesophageal fistula after aortic grafting. Ann Thorac Surg. 1997;64:253-5.[Abstract/Free Full Text]
  4. Grundy A, Glees JP. Aorto-oesophageal fistula: a complication of oesophageal stenting. Br J Radiol. 1997;70:846-9.[Medline]
  5. Allgaier HP, Schwacha H, Technau K, et al. Fatal esophagoaortic fistula after placement of a self-expanding metal stent in a patient with esophageal carcinoma. N Engl J Med. 1997;337:1778.[Free Full Text]
  6. Nouraei SM, Pillay T, Hilton CJ. Emergency management of aorto-bronchial fistula after implantation of a self-expanding bronchial stent. Eur J Cardiothorac Surg. 2001;20:642-4.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
L. Stoica, S. Chocron, P.-E. Falcoz, and J.-P. Etievent
Endovascular stent grafting for contained rupture of the descending thoracic aorta
Eur. J. Cardiothorac. Surg., June 1, 2003; 23(6): 1068 - 1070.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Sidney Chocron
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chocron, S.
Right arrow Articles by Etievent, J.-P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chocron, S.
Right arrow Articles by Etievent, J.-P.
Related Collections
Right arrow Great vessels


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS