JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Tomislav Mihaljevic
Pedro J. del Nido
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mihaljevic, T.
Right arrow Articles by del Nido, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mihaljevic, T.
Right arrow Articles by del Nido, P. J.
Related Collections
Right arrow Congenital - acyanotic
Right arrow Great vessels
Right arrow Minimally invasive surgery

J Thorac Cardiovasc Surg 2003;125:1163-1164
© 2003 The American Association for Thoracic Surgery


Brief Communications

Robotically assisted division of a vascular ring in children

Tomislav Mihaljevic, MD, Jeremy W. Cannon, MD, Pedro J. del Nido, MD Boston, Mass

From the Department of Cardiovascular Surgery, Children's Hospital-Boston and Harvard Medical School, Boston, Mass.

Supported in part by National Institutes of Health grant F32 HL68404-01 (J.W.C.) and a Research Development Grant, Children's Hospital-Boston.

Received for publication July 17, 2002. Accepted for publication July 25, 2002. Address for reprints: Pedro J. del Nido, MD, Department of Cardiovascular Surgery, Children's Hospital-Boston, 300 Longwood Ave, Boston, MA 02115 (E-mail: pedro.delnido{at}tch.harvard.edu).

Over the past decade, technical advances, including the evolution of thoracoscopic instruments and high-resolution cameras, have contributed to the widespread use of video-assisted thoracoscopic techniques in the pediatric population. Introduction of robotic surgical systems represents a further step in the evolution of endoscopic instrumentation. These computer-enhanced systems offer 3-dimensional visualization and significantly improved instrumentation, with motion scaling and a wrist mechanism that allow the performance of fine microsurgical tasks by using an endoscopic approach. These specific advantages make the use of this technology potentially beneficial for the treatment of pediatric patients. This report describes the use of a robotic surgical system for the division of a vascular ring in 2 patients.

Clinical summary

The first patient was a 10-year-old girl (height, 150 cm; weight, 48 kg) who presented with the complaint of recurrent vomiting; a barium swallow showed evidence of esophageal compression. The second patient was an 8-year-old girl (height, 120 cm; weights 27 kg) who presented with a history of recurrent upper respiratory tract infections and dysphagia. Chest magnetic resonance imaging in both patients confirmed the presence of a vascular ring comprised of a right-sided aortic arch, an aberrant left subclavian artery, and compression of the trachea and esophagus consistent with a left-sided ligamentum arteriosum. Institutional informed consent for robotically assisted vascular ring division was obtained for both patients.

After achievement of general anesthesia with single lung ventilation, both patients were positioned in an exaggerated right lateral decubitus position (15°-20° slightly prone) to allow easier retraction of the left lung and better visualization of the surgical field. Routine monitoring included transcutaneous oxygen saturation, continuous end-tidal carbon dioxide, and serial blood gas measurements.

The robotic surgical cart (da Vinci; Intuitive Surgical, Inc, Sunnyvale, Calif) was positioned at the cranial end of the operating table angled 30° to the patient's left side (Figure 1). Three thoracoscopic trocars were placed in the left hemithorax to accommodate the camera and 2 robotic manipulators (Figure 1Go, inset). An additional small utility incision was placed between the left instrument and camera incisions for insertion of a lung retractor. After thoracoscopic verification of the anatomy, the camera was attached to the robotic cart, and the robotic instruments were placed through the left and right trocars.



View larger version (48K):
[in this window]
[in a new window]
 
Fig. 1. Intraoperative setup for robot-assisted vascular ring division. The patient is positioned in an exaggerated right lateral decubitus position, with the left arm extended above the head. The robotic arms are brought in over the patient's shoulder to allow optimal access to the upper thorax. The inset shows the port sites used for the cases reported here. The left instrument port (L) is placed in the third interspace along the anterior axillary line, whereas the camera port (C) is placed in the fifth intercostal space and the right instrument port in the posterior sixth intercostal space behind the scapula.

 
The dissection was performed with the surgeon at the master console, which was remote from the operating table, and using a grasper in the left robotic arm and a hook-tip cautery at a low setting in the right robotic arm. Once the dissection of the ligamentum was completed, 2 clips were placed at each end of this structure by using a thoracoscopic clip applier (Figure 2, A). Division of the ligamentum and complete dissection of the fibrous bands along the esophagus were performed with robotic scissors (Figure 2Go, B). Finally, the left recurrent nerve was identified by using an intrathoracic stimulating probe with electromyographic monitoring.Go 1 A single chest tube was placed through the utility thoracostomy at the completion of the procedure. Operative times were 180 and 165 minutes, respectively, with procedure times of 115 and 98 minutes. Both patients were extubated in the operating room. The postoperative recovery was uneventful in both patients, who were discharged to home on the first postoperative day.



View larger version (59K):
[in this window]
[in a new window]
 
Fig. 2. Intraoperative thoracoscopic views of a robot-assisted vascular ring division. The ligamentum was exposed just above the first intercostal vein (small arrow). Dissection around this structure freed it from the esophagus (arrowheads), and endoscopic clips were applied proximally and distally (A). Dividing the ligamentum adjacent to its origin from the diverticulum of the aberrant left subclavian artery (large arrow) relieved the esophageal compression (B).

 
Discussion

Surgical treatment of patients with a vascular ring has evolved from the standard approach through posterolateral thoracotomy to a closed-chest video-assisted thoracoscopic approach.Go Go 2-4 This article documents the first reported use of a telerobotic surgical system for the division of vascular rings in children.

Robotic surgical systems offer significant advantages over the standard thoracoscopic approach because of improved visualization and computer-enhanced instrumentation. An important practical aspect of the successful use of robotic systems is appropriate patient positioning with proper placement of the thoracostomy incisions and the robotic arms. We have found that an exaggerated right lateral decubitus position with slight pronation of the patient allows the left lung to be positioned more anteriorly, affording better exposure of posterior mediastinal structures. Angulation of the surgical cart to the left side at the cranial end of the operating table permits optimal camera and instrument positioning.

Another important technical aspect of the operation for vascular ring division is division of all fibrous bands around the trachea and esophagus. This task was easily accomplished with EndoWrist instruments, including an articulated grasper, a hook-tip cautery on a low energy setting, and articulated scissors. Enhanced intracorporeal dexterity, optimized hand-eye alignment, and tremor filtering made tissue handling and dissection easy and accurate. The total operative time was somewhat longer than is usually required for conventional thoracoscopic division of a vascular ring, with positioning of the surgical cart and placement of the robotic arms accounting for the majority of the time difference. The dissection time, however, was slightly shorter.

Although instrument size has limited the use of robotic systems in the pediatric population, application of this technology for the treatment of patent ductus arteriosus has proved to be a safe alternative in children.Go 5 Furthermore, this report illustrates the utility of these systems for performing a precise dissection for vascular ring division in pediatric patients. Future advances, including decreased instrument size, use of imaging for procedure guidance, and incorporation of tactile feedback,Go 6 promise to further expand the applications for robotic technology in the treatment of patients with congenital heart disease.

References

  1. Odegard KC, Kirse DJ, del Nido PJ, Laussen PC, Casta A, Booke J, et al. Intraoperative recurrent laryngeal nerve monitoring during video-assisted thoracoscopic surgery for patent ductus arteriosus. J Cardiothorac Vasc Anesth. 2000;14:562-4.[Medline]
  2. Burke RP, Wernovsky G, van der Velde M, Hansen D, Castandeda AR. Video-assisted thoracoscopic surgery for congenital heart disease. J Thorac Cardiovasc Surg. 1995;109:499-507.[Abstract/Free Full Text]
  3. Burke RP, Chang AC. Video-assisted thoracoscopic division of a vascular ring in an infant: a new operative technique. J Card Surg. 1993;8:537-40.[Medline]
  4. Burke RP, Rosenfeld HM, Wernovsky G, Jonas RA. Video-assisted thoracoscopic vascular ring division in infants and children. J Am Coll Cardiol. 1995;25:943-7.[Abstract]
  5. Le Bret E, Papadatos S, Folliguet T, Carbognani D, Pétrie J, Aggoun Y, et al. Interruption of patent ductus arteriosus in children: robotically assisted versus videothoracoscopic surgery. J Thorac Cardiovasc Surg. 2002;123:973-6.[Abstract/Free Full Text]
  6. Cannon JW, Howe RD, Dupont PE, Triedman JK, Marx GR, del Nido PJ. Application of robotics in congenital cardiac surgery. Semin Thorac Cardiovasc Surg. In press.



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
D. G. Pennington
The Impact of New Technology on Cardiothoracic Surgical Practice
Ann. Thorac. Surg., January 1, 2006; 81(1): 10 - 18.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Suematsu, B. N. Mora, T. Mihaljevic, and P. J. del Nido
Totally Endoscopic Robotic-Assisted Repair of Patent Ductus Arteriosus and Vascular Ring in Children
Ann. Thorac. Surg., December 1, 2005; 80(6): 2309 - 2313.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Tomislav Mihaljevic
Pedro J. del Nido
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mihaljevic, T.
Right arrow Articles by del Nido, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mihaljevic, T.
Right arrow Articles by del Nido, P. J.
Related Collections
Right arrow Congenital - acyanotic
Right arrow Great vessels
Right arrow Minimally invasive surgery


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS