JTCS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Randall K. Wolf
Michael P. Caskey
Allen R. Raczkowski
Mercedes K. Dullum
Dwight C. Lundell
Nan Wang
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wolf, R. K.
Right arrow Articles by Daniel, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wolf, R. K.
Right arrow Articles by Daniel, M. A.
Related Collections
Right arrow Coronary disease
Right arrow Minimally invasive surgery
Right arrowRelated Article

J Thorac Cardiovasc Surg 2003;126:168-177
© 2003 The American Association for Thoracic Surgery


Cardiopulmonary support and physiology

Clinical and six-month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self-closing clip device: a multicenter prospective clinical trial

Randall K. Wolf, MDa,*, Edwin L. Alderman, MDb, Michael P. Caskey, MDc, Allen R. Raczkowski, MDd, Mercedes K. Dullum, MDe, Dwight C. Lundell, MDd, Arthur C. Hill, MDf, Nan Wang, MDg, Michael A. Daniel, MS, MBAh

a Ohio State University, Columbus, Ohio, USA
b Stanford University Medical Center, Palo Alto, Calif, USA
c St Joseph’s Hospital, Phoenix, Ariz, USA
d Desert Samaritan Hospital, Mesa, Ariz;USA,
e Washington Hospital Center, Washington, DC, USA
f University of Nebraska, Omaha, Neb, USA
g King Fahad Hospital, Riyadh, Saudi Arabia
h Daniel & Daniel Consulting, Orinda, Calif, USA

Read at the Eighty-second Annual Meeting of The American Association for Thoracic Surgery, Washington, DC, May 5-8, 2002.

Received for publication May 20, 2002; revisions received July 22, 2002; * Address for reprints: Randall K. Wolf, MD, The Ohio State University, N816 Doan Hall, 410 W 10th Ave, Columbus, OH 43210, USA
wolf-4{at}medctr.osu.edu


    Abstract
 Top
 Abstract
 Materials and methods
 Results
 Discussion
 Conclusions
 Appendix. Exclusion criteria
 References
 
OBJECTIVES: To evaluate the safety and effectiveness of a self-closing surgical clip with an interrupted technique in left internal thoracic artery to left anterior descending artery bypass grafting.

METHODS: Eighty-two patients were enrolled and treated (February 2000 through August 2001) in a prospective, nonrandomized, multicenter trial. Left internal thoracic artery to left anterior descending artery anastomoses were performed in 60 off-pump coronary artery bypasses (73%), 12 conventional coronary artery bypass grafting (15%), and 10 minimally invasive direct coronary artery bypass (12%) procedures. Angiograms (64 to 383 days, mean 200 days) were obtained on 63 patients (77%). Qualitative and quantitative angiographic assessment was performed by an independent core laboratory.

RESULTS: The self-closing surgical clip was used for 82 left internal thoracic artery to left anterior descending artery interrupted anastomoses without the requirement for knot tying or primary suture management. Minimum left internal thoracic artery to left anterior descending artery anastomosis time was 3 minutes. There was one perioperative and one late death (both not heart related) and one reexploration for bleeding unrelated to the anastomotic site. FitzGibbon grades were as follows: A (n = 60, 95.2%), B (n = 3, 4.8%) including one kinked left internal thoracic artery, and O (n = 0, 0%). Quantitative analysis (n = 57) showed mean lumen diameters of left internal thoracic artery proximal to the anastomosis of 2.1 mm, at anastomosis of 2.0 mm, and in the left anterior descending artery distal to the anastomosis of 1.9 mm. The average ratio of the anastomosis to the left anterior descending artery diameter was 1.14 (0.45 to 1.93). Anastomotic stenosis as a percentage of average left internal thoracic artery to left anterior descending artery diameter was -2.3%, comparing favorably with results (23% to 24%) reported from the Patency, Outcomes, Economics, Minimally invasive direct coronary artery (POEM) bypass study.

CONCLUSIONS: The interrupted technique, facilitated by a self-closing anastomotic clip, yields favorable 6-month angiographic results when compared with other published studies.



Dr Wolf


The frequent presumption of a long-term (> 10 years) left internal thoracic artery (LITA) to left anterior descending artery (LAD) patency rate of 96% by many heart surgeons has recently been called into question. Results of 96% patency rates at 5 and 10 years, reported by Lytle,1 Loop,2 and their associates at the Cleveland Clinic in 1985 and 1986, were obtained by use of a compliant, interrupted suture technique in conjunction with cardiopulmonary bypass. Extrapolation of these benchmark Cleveland Clinic results to the continuous suture technique and to current minimally invasive procedures including off-pump or beating heart surgery is not supported by other published studies3-5 (Table 1). These studies have invariably used the more expedient continuous suture technique.3,4 Reintervention rates for coronary artery bypasses have recently been reported to be as high as 39% within 8 years.6


View this table:
[in this window]
[in a new window]
 
TABLE 1. 100+ patient ITA patency studies with >= 5-year angiographic follow-up

 
The emergence of beating heart surgery has resulted in a widespread reassessment of anastomotic quality. This is illustrated by the significant upswing in the number of articles about coronary artery bypass grafting (CABG) published with reference to "patency" or "quality" (Figure 1) since the introduction of the off-pump technique. It is clear that the raison d’etre of heart surgery must be a high-quality anastomosis, and the fact that this must frequently be achieved on a beating heart while working through smaller incisions continues to motivate the development of improved surgical techniques and facilitating surgical technology.



View larger version (22K):
[in this window]
[in a new window]
 
Figure 1. The number of studies that come up each year from the MEDLINE search "(patency or quality) and CABG."

 
One of the issues that recently has emerged again in this context is the question of continuous versus interrupted suture technique. The vascular anastomosis originally developed by Alexis Carrel, 1912 Nobel Laureate in Medicine, used a modified interrupted technique. This interrupted suture technique was initially adopted by heart surgeons as surgical revascularization became the standard of care in the late 1970s. Results published in now-seminal articles by Loop1 and Lytle2 and associates have been based on this interrupted approach. Subsequently, as CABG procedures became more prevalent, there occurred a shift in basic anastomotic methods away from the established interrupted technique to a more expedient, continuous suture approach in response to pressures associated with resource use and operating time. Microvascular, pediatric and neurovascular surgeons have demonstrated that there are significant advantages to using an interrupted technique.7,8 However, until recently, issues of suture management, manpower, and resource use continued to inhibit adoption of this interrupted technique.

This study was intended to formally revisit the use of the interrupted technique to improve anastomotic patency and quality by use of a now well-established self-closing clip technology. The Investigational Device Exemption– (IDE) based clinical trial was designed in consultation with the Food and Drug Administration (FDA) with the objective of demonstrating the safety and effectiveness of the Coalescent Surgical U-Clip anastomotic device (Sunnyvale, Calif) for specific cardiovascular/CABG indications.


    Materials and methods
 Top
 Abstract
 Materials and methods
 Results
 Discussion
 Conclusions
 Appendix. Exclusion criteria
 References
 
This was a prospective, nonrandomized study designed to compare interrupted anastomotic technique facilitated by the U-Clip study device with historically published results obtained by use of continuous suture. The requirement for approximately 60, 6-month postoperative angiograms was established by use of an FDA-suggested method. Enrollment continued until it was clear that the minimum number of required 6-month angiograms would be obtained.

The U-Clip (Figure 2) comprises four basic components: a self-closing clip, a release mechanism, a flexible member, and a needle. Surgical application consists of (1) piercing the desired tissue with the needle and placement of the clip by pulling the flexible member and release mechanism through the tissue (Figure 3, a), and (2) closure of the clip and release of the delivery mechanism by the application of pressure (Figure 3, b). Once released, the needle and flexible member are removed and discarded (Figure 3, c). Anastomoses are formed in the usual manner with a number of clips applied in a circular fashion around the anastomotic site (Figure 3, d). Individual placement of U-Clips results in a desired "cobra-head" appearance of the completed anastomosis (Figure 4).



View larger version (147K):
[in this window]
[in a new window]
 
Figure 2. Photograph of the study device (Coalescent U-Clip device).

 


View larger version (33K):
[in this window]
[in a new window]
 
Figure 3. a, Placement of U-Clip device; b, pressure applied to release; c, U-Clip closure and removal of needle and flexible member; d, finished anastomosis.

 


View larger version (96K):
[in this window]
[in a new window]
 
Figure 4. Completed LITA-LAD anastomosis with "cobra-head" appearance.

 
Study inclusion and exclusion criteria were adopted from the joint American College of Cardiology and American Heart Association practice guidelines for coronary artery bypass graft surgery9 and coronary artery angiography.10 Other inclusion criteria were ages between 18 and 80 years, body mass index (BMI) of less than 35 kg/m2, and left ventricular ejection fraction of 30% or greater. The exclusion criteria of this study are listed in the Appendix.

A total of six clinical sites and eight principal investigators participated in the study. Investigators were allowed to use either arrested heart or beating heart techniques, depending on their individual preference and the operative situation. Each investigator was given the opportunity to use the study device to complete anastomoses on a porcine heart ex vivo before the device was used clinically. This was the only training that each investigator received before beginning the study. Patients meeting all inclusion criteria and signing informed consent were enrolled into the study. The study device was used to complete a LITA-LAD interrupted anastomosis in the same basic manner as suture, with the exception of knot tying. Case report forms were completed per protocol. Patients were treated after operation in the usual and customary fashion, with no additional anticoagulation administered. All patients were followed up at approximately 2 weeks and then again at 6 months after discharge.



View larger version (159K):
[in this window]
[in a new window]
 
Figure 5. Anastomotic dimensions determined during QCA. A, portion of LITA graft immediately proximal to anastomosis; B, anastomosis dimension (typically defined as MLD); C, native LAD immediately distal to anastomosis site. Calculation for average percent diameter stenosis is shown.

 
The core angiographic laboratory at Stanford University Medical Center, under the direction of Edwin Alderman, was used to independently evaluate all LITA-LAD anastomoses. Alderman (using standard angiographic computer software) personally completed the quantitative analysis of all of the postoperative angiograms obtained during this study. Standard measurements taken are shown in Figure 5 along with the calculation described below.


    Results
 Top
 Abstract
 Materials and methods
 Results
 Discussion
 Conclusions
 Appendix. Exclusion criteria
 References
 
Enrollment, demographics, and follow-up
Seventy men and 12 women with a mean age of 65.2 years (43 to 81) and a mean BMI of 28.8 kg/m2 (19.7 to 40.6 kg/m2) were enrolled and treated (Table 2). All patients had follow-up office visits, and a total of 63 (77%) consented to return for detailed angiographic study at an average of 200 days after operation (64 to 383 days). Two angiograms (3%) were completed before 160 days (64 and 110 days), 47 (74%) were completed between 160 and 200 days after operation, 11 (17%) were completed between 200 and 300 days, and 4 (6%) were completed at more than 300 days after operation.


View this table:
[in this window]
[in a new window]
 
TABLE 2. Enrollment, demographics, and follow-up

 
Intraoperative summary
LITA-to-LAD interrupted anastomoses were completed by use of the U-Clip in 82 total procedures; 70 (85%) were completed off-pump on the beating heart (Table 3). A total of 72 (88%) were completed by median sternotomy approach including 60 (73%) off-pump coronary artery bypass (OPCAB) procedures and 12 (15%) classic CABG (median sternotomy, on pump) procedures. The remaining 10 (12%) were completed by use of a minimally invasive direct coronary artery bypass (beating heart) (MIDCAB) or video-assisted direct coronary artery bypass procedure.


View this table:
[in this window]
[in a new window]
 
TABLE 3. Procedural summary (core lab measurements)

 
The average LITA diameter (immediately proximal to the anastomosis) and LAD (immediately distal to the anastomosis) lumen diameters (measured quantitatively at time of follow-up angiography) were 2.1 and 1.9 mm, respectively (Table 3), with 30% of LADs less than 1.5 mm. Two cases were excluded during operation per the protocol exclusion requirement of "unexpected intraoperative findings creating an unreasonable intraoperative risk, an increased probability of postoperative complications in terms of recovery or later completion of postoperative angiogram." As reported earlier,11 one of these two patients undergoing an OPCAB procedure required an unusually long onlay patchlike anastomosis because of a severely calcified target vessel. The second patient (the first case attempted at one of the institutions) was excluded during operation because of what the surgeon reported as a "LAD and LITA wall thickness mismatch."

The average number of U-Clips used was 11.8 with a minimum of six and a maximum of 24. Mean LITA-LAD anastomosis time was 12.4 minutes (3 to 35 minutes) overall and averaged less than 10 minutes after the first 8 cases. These post initial learning curve times are entirely consistent with typical times required for completing anastomoses on beating hearts by use of a continuous suture technique. Each investigator reported the occasional requirement for the removal of one or more clips and subsequent replacement without problem or difficulty. There was one perioperative death (duodenal perforation) and one late death (respiratory failure at 11 days after operation). One reexploration was performed for bleeding found to be unrelated to any of the anastomotic sites. One perioperative myocardial infarction occurred in 1 patient. This adverse event was reported to be unrelated to the LAD target distribution. No adverse events, either during operation, before discharge, or at follow-up, were attributed to the U-Clip. There were 2 cases of arrhythmia, 1 transient ischemic attack, and 1 case of pleural effusion reported during the 6-month follow-up period. Including all treated patients, the reported 6-month major adverse cardiac events (MACE) rate was 2.4% (2/82), both unrelated to the use of the study device. There were no differences in morbidity or mortality rates or obvious clinical outcome among the 63 patients who returned for follow-up angiography and the 19 patients who refused.

Core laboratory analysis
The core angiographic laboratory at Stanford used both qualitative and quantitative methods to evaluate each anastomosis. Qualitative methods included estimates of Thrombosis In Myocardial Infarction (TIMI) trial flow and general assessments of patency. More definitive, quantitative techniques included assignment of FitzGibbon score that included not only the quality of the anastomosis (greater or less than 50% stenosed) but graft quality and patency as well. Finally, the most quantitative analysis was completed by measuring the luminal diameters of the LITA distal and immediately proximal to the anastomosis, the anastomosis itself, and the luminal diameter of the native LAD immediately distal to the anastomosis. These dimensions made it possible to calculate the ratio of the anastomosis to the LAD and also the average percent diameter stenosis, as used in the Patency Outcomes Economics MIDCAB (POEM) study (see discussion below).

Angiograms were completed on a total of 63 out of 82 treated patients (76.8%). All 63 (100%) LITA-LAD anastomoses completed with the U-Clip device were found to be patent at follow-up (Table 4). The core angiographic laboratory graded 60 (95%) of the 63, 6-month postoperative angiograms as FitzGibbon grade A (< 50% stenosis of either graft trunk or anastomosis when compared with LAD) and three (5%) as FitzGibbon grade B (> 50% stenosis), including one kinked LITA graft unrelated to the anastomosis. There were no occlusions (FitzGibbon grade O) observed. Detailed quantitative analysis (n = 57) showed mean lumen diameters of the LITA proximal to the anastomosis of 2.1 mm, at the anastomosis of 2.0 mm, and in the LAD distal to the anastomosis of 1.9 mm (Table 3). The average ratio of the anastomosis to the LAD diameter was 1.14 (0.45 to 1.93). Anastomotic stenosis as a percentage of average LITA/LAD diameter was -2.3%, excluding the one FitzGibbon grade B result that could not be quantified because of competing native vessel flow and including 30 instances (48%) where the anastomosis was found to be larger than the reference vessel diameter. * Fifty-nine cases (93.7%) were graded TIMI grade 3, one (1.6%) was graded TIMI grade 2, and three (4.7%) were graded TIMI grade 1 because of poor distal bed runoff (Table 4). There was very poor correlation between these subjective TIMI flow measurements and objective quantitative analysis (Table 5). Again, this highlights the importance of quantitative angiographic analysis (QCA) for evaluating new techniques and technologies in CABG procedures.


View this table:
[in this window]
[in a new window]
 
TABLE 4. Core lab results

 

View this table:
[in this window]
[in a new window]
 
TABLE 5. Analysis of FitzGibbon grade B results

 
Further analysis of the three instances of FitzGibbon grade B results (Table 5) revealed that 2 of these 3 cases represented the first cases completed by each of two surgeons. In two instances the ratio of the anastomosis to LAD was just under 50% (0.45 and 0.48). In the third case the ratio was greater than 50% (0.83); however, a kink in the LITA was measured at less than half of the LAD luminal diameter and, consequently, the result was categorized as grade B. There was no correlation with TIMI flow because two of the three grade B results showed perfect TIMI grade 3 flow.


    Discussion
 Top
 Abstract
 Materials and methods
 Results
 Discussion
 Conclusions
 Appendix. Exclusion criteria
 References
 
The results from this clinical study can be compared with three different categories of published studies: (1) studies (both on and off pump) reporting simple qualitative patency only (with or without TIMI flow) between 6 and 12 months after operation (Figure 6); (2) studies reporting more quantitative FitzGibbon scores between 6 and 12 months after operation (Figure 7); and, (3) the one recent study reporting highly quantitative specific "percent diameter stenosis" values at 6 months (POEM study, Table 6).



View larger version (32K):
[in this window]
[in a new window]
 
Figure 6. Patency comparison among studies with angiographic analysis at 6 months.

 


View larger version (43K):
[in this window]
[in a new window]
 
Figure 7. Studies reporting results by use of FitzGibbon patency classification scale.

 

View this table:
[in this window]
[in a new window]
 
TABLE 6. Quantitative angiographic results: comparison to POEM* study

 
Of the 17 CABG and 28 OPCAB studies reviewed (3368 and 2743 patients, respectively) only four were multicenter studies, 12 included angiographic follow-up at 6 months, five reported quantitative coronary angiography, three used an independent core angiographic laboratory, and only one study reported percent average diameter stenosis for both conventional CABG and OPCAB.1-6,12-49

Only one study (single-center, single surgeon)31 of a total of 12 reporting angiographic patency results at 6 months showed the same 100% patency rate as was observed in the U-Clip study (Figure 6).2,5,32-39,49 All other available studies at the same 6-month follow-up period reported occlusion rates of between 1.5% and 10%. Study sample sizes ranged from 38 to 452 patients, and the overall average patency rate for all 12 studies was the same 95% reported by FitzGibbon5 in the largest single study.

On the more quantitative FitzGibbon scale, there were three reports35-37 out of 20 other studies reporting Fitzgibbon scores that were marginally better than those observed in this U-Clip study (Figure 7).5,35-48 However, these three studies reported the observation of total occlusions not experienced in the U-Clip study.

Finally, when the results are compared with the most quantitative study available, the POEM study35 (Table 6), a significant improvement in overall patency and average percent diameter stenosis (calculations shown in Figure 5) using the U-Clip device is evident. The POEM trial represents an example of the next generation of anastomotic clinical study. It was a multicenter study of on- and off-pump CABG that used an independent core angiographic laboratory [Cardiovascular Research Foundation (CRF)] that used QCA, ensuring representative sampling of surgical skill and nonbiased review of angiographic data. CRF reported an average of 23% and 24% average percent diameter stenosis (63% 6-month angiographic follow-up) in the POEM study for CABG and MIDCAB, respectively (Table 6). This average percent diameter stenosis value (a calculation favored by CRF) compares the size of the anastomosis with the average of the LITA immediately proximal to the anastomosis and the LAD immediately distal to the anastomosis. The U-Clip study by comparison showed anastomotic stenosis as a percentage of average LITA and LAD diameter to be -2.3%. This result is significantly superior to what was reported in the POEM study (P < .001).

Limitations of this study include a modest sample size and a nonrandomized patient population selected for conformance to prespecified inclusion and exclusion criteria. Given these limitations, however, the results appear to support the hypothesis that an interrupted technique results in a superior vascular anastomosis. This is believed to be due to two primary factors. Firstly, increased anastomotic compliance and flow rate resulting from the interrupted technique, and, secondly, the elimination of the potential for purse-string and puckering effects encountered when attempting to achieve hemostasis by use of a continuous piece of conventional suture.47-49 An additional advantage of the U-Clip is the availability of a fresh, sharp needle with each clip, decreasing target vessel needle injury, especially in the less than ideal target.

We believe that it is important to carefully and objectively assess achieved anastomotic quality rather than make the potentially incorrect assumption of a 96% patency rate (shown by the Cleveland Clinic when an interrupted technique is used). This is best done with objective 6- to 12-month postoperative QCA as a benchmark. This is consistent with the adoption of QCA as the standard of care by the American Heart Association50 and the establishment of QCA as a requirement by the FDA for evaluation of any new interventional and surgical anastomotic device.

To date, more than 100,000 interrupted coronary anastomoses have been completed worldwide by use of the U-Clip device. This possible trend toward returning to the interrupted suture technique will allow further assessment of the impact on both individual graft patency and the continued viability of surgical revascularization.

In relationship to cost, any significant increase in procedure cost in this era of managed care would be of concern. After an initial learning curve, 8 to 10 clips are typically used per anastomosis for a cost of approximately $150. Suture costs per anastomosis vary widely, depending on several factors, including technique (interrupted versus continuous), suture material (silk, polypropylene, etc), needle configuration, hospital volume, and overall group purchasing organization affiliation. Silk sutures, often used for the interrupted technique, vary in price from $7 to $15 per strand, yielding a price per anastomosis ranging from $84 to $180 (assuming 12 sutures per anastomosis).51

Polypropylene sutures, most frequently used in a single-stranded continuous technique, vary in price from $15 to $120, yielding a similar price per anastomosis.

In 1998 average cost of CABG was reported as $44,820.52 With this used as a benchmark, conversion of three distal anastomoses from suture to the U-Clip anastomotic device would result in an incremental procedural cost of $405 (less than 1% of overall procedural cost) at worst and would be cost neutral at best.


    Conclusions
 Top
 Abstract
 Materials and methods
 Results
 Discussion
 Conclusions
 Appendix. Exclusion criteria
 References
 
Use of the U-Clip device to facilitate an interrupted anastomosis resulted in excellent and unequaled long-term graft patency and anastomotic quality as objectively assessed by use of quantitative, 6-month postoperative angiographic analysis. These results were obtained in spite of the variables associated with a multicenter, multisurgeon, multitechnique study that included the learning curve associated with the use of a new device.

The results of this study show that the U-Clip device is capable of facilitating the use of the interrupted technique in both on- and off-pump CABG procedures and, as such, represent an important next step in the effort to continuously improve the quality of cardiovascular anastomosis.


    Appendix. Exclusion criteria
 Top
 Abstract
 Materials and methods
 Results
 Discussion
 Conclusions
 Appendix. Exclusion criteria
 References
 


Preoperative exclusion criteria

Severe cerebrovascular disease, including history of stroke within 1 month
History of renal insufficiency (serum creatinine level >2 mg/dL)
Active gastrointestinal bleeding
Active infection or fever (>38.3°C), which may be caused by infection
Short life expectancy (<2 years) as a result of cancer or pulmonary, hepatic, or renal disease
Significant anemia (hemoglobin level <8.0 g)
Severe, uncontrolled systemic hypertension (systolic pressure >240 mm Hg within 1 month)
Severe electrolyte imbalance
Documented anaphylaxis during previous exposure to angiographic contrast media
Congestive heart failure
Severe systemic disease
History of pericarditis, median sternotomy, or chest irradiation
Uncontrollable diabetes (>=2 glucose levels >350 mg/dL within 7 days)
Bleeding diathesis
Vasculitis
History of intravenous drug use within prior year
Participating in another investigational protocol
Unwilling or unable to comply with any protocol requirements
Intraoperative exclusion criteria
Inadequate estimated LITA flow
Small LAD size at anastomotic site (<1 mm)
Inadequate or damaged LITA
Severe intramyocardial LAD (off-pump cases)
Other presenting complications prohibiting use of either LITA or LAD
Unexpected findings of any intraoperative exclusion
Unexpected findings creating an unreasonable intraoperative risk or an increased probability of postoperative complications


    Footnotes
 
This work was funded by the clinical trial sponsor Coalescent Surgical, Inc.


    References
 Top
 Abstract
 Materials and methods
 Results
 Discussion
 Conclusions
 Appendix. Exclusion criteria
 References
 

  1. Lytle BW, Loop FD, Cosgrove DM, Ratliff NB, Easley K, Taylor PC. Long-term (5 to 12 years) serial studies of internal mammary artery and saphenous vein coronary bypass grafts. J Thorac Cardiovasc Surg. 1985;89:248–258[Abstract]
  2. Loop FD, Lytle BW, Cosgrove DM, Stewart RW, Goormastic M, Williams GW, et al. Influence of the internal-mammary-artery graft on 10-year survival and other cardiac events. N Engl J Med. 1986;314:1–6[Medline]
  3. Tyras DH, Barner HB, Kaiser GC, Codd JE, Pennington DG, Willman VL. Bypass grafts to the left anterior descending coronary artery: saphenous vein versus internal mammary artery. J Thorac Cardiovasc Surg. 1980;80:327–333[Abstract]
  4. Ivert T, Huttunen K, Landou C, Bjork VO. Angiographic studies of internal mammary artery grafts 11 years after coronary artery bypass grafting. J Thorac Cardiovasc Surg. 1988;96:1–12[Abstract]
  5. Fitzgibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1388 patients during 25 years. J Am Coll Cardiol. 1996;28:616–626[Medline]
  6. King SB III, Kosinski AS, Guyton RA, Lembo NJ, Weintraub WS. Eight-year mortality in the Emory Angioplasty versus Surgery Trial (EAST). J Am Coll Cardiol. 2000;35:1116–1121[Medline]
  7. Hattori H, Killen DA, Green JW. Influence of suture materials and technic on patency of anastomosed arteries of less than 1.5 mm. diameter. Am Surg. 1970;36:352–354[Medline]
  8. Cobbett JR. Microvascular surgery. Surg Clin N Am. 1962;47:521
  9. American College of Cardiology (ACC) and American Heart Association (AHA) practice guidelines for coronary artery bypass graft surgery. J Am Coll Cardiol. 1991;17:543–589[Medline]
  10. American College of Cardiology (ACC) and American Heart Association (AHA) practice guidelines for coronary angiography. J Am Coll Cardiol. 1987;10:935–949[Medline]
  11. Ono M, Wolf RK, Angouras D, Schneeberger EW. Early experience of coronary artery bypass grafting with a new self-closing clip device. J Thorac Cardiovasc Surg. 2002;123:783–787[Abstract/Free Full Text]
  12. Geha AS, Baue AE. Early and late results of coronary revascularization with saphenous vein and internal mammary artery grafts. Am J Surg. 1979;137:456–463[Medline]
  13. Goldman S, Copeland J, Moritz T, Henderson W, Zadina K, Ovitt T, et al. Internal mammary artery and saphenous vein graft patency-effects of aspirin. Circulation. 1990;82(Suppl):IV237–242
  14. Grondin CM, Campeau L, Lesperance J, Enjalbert M, Bourassa MG. Comparison of late changes in internal mammary artery and saphenous vein grafts in two consecutive series of patients 10 years after operation. Circulation. 1984;70(Pt 2):I208–212
  15. Higami T, Yamashita T, Nohara H, Iwahashi K, Shida T, Ogawa K. Early results of coronary grafting using ultrasonically skeletonized internal thoracic arteries. Ann Thorac Surg. 2001;71:1224–1228[Abstract/Free Full Text]
  16. Wendler O, Hennen B, Demertzis S, Markwirth T, Tscholl D, Lausberg H, et al. Complete arterial revascularization in multivessel coronary artery disease with 2 conduits (skeletonized grafts and T grafts). Circulation. 2000;102(Suppl 3):III79–83
  17. Amano A, Hirose H, Takahashi A, Nagano N. Off-pump coronary artery bypass. Mid-term results. Jpn J Thorac Cardiovasc Surg. 2001;49:67–78[Medline]
  18. Bhan A, Choudhary SK, Mathur A, Sharma R, Sahoo M, Agrawal R, et al. Surgical myocardial revascularization without cardiopulmonary bypass. Ann Thorac Surg. 2000;69:1216–1221[Abstract/Free Full Text]
  19. Detter C, Reichenspurner H, Boehm DH, Thalhammer M, Schutz A, Reichart B. Single vessel revascularization with beating heart techniques: minithoracotomy or sternotomy. Eur J Cardiothorac Surg. 2001;19:464–470[Abstract/Free Full Text]
  20. Douville EC, Handy JR Jr, Tsen AC, Ott GY, Gilbert M, Asaph JW. MIDCAB: impact of epicardial stabilization upon outcomes. Heart Surg Forum. 1999;2:41–46[Medline]
  21. Elbeery JR, Brown PM, Chitwood WR Jr. Intraoperative MIDCABG arteriography via the left radial artery: a comparison with Doppler ultrasound for assessment of graft patency. Ann Thorac Surg. 1998;66:51–55[Abstract/Free Full Text]
  22. Katz WE, Zenati M, Mandarino WA, Cohen HA, Gorcsan J III. Assessment of left internal mammary artery graft patency and flow reserve after minimally invasive direct coronary artery bypass. Am J Cardiol. 1999;84:795–801[Medline]
  23. Kim KB, Lim C, Lee C, Chae IH, Oh BH, Lee MM, Park YB. Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts. Ann Thorac Surg. 2001;72:S1033–1037[Abstract/Free Full Text]
  24. Schaff, Cable, Rihal, Daly, Orszulak. Minimal thoracotomy for coronary artery bypass: value of immediate postprocedural graft angiography. Circulation 1996
  25. Subramanian VA, McCabe JC, Geller CM. Minimally invasive direct coronary artery bypass grafting: two-year clinical experience. Ann Thorac Surg. 1997;64:1648–1653[Abstract/Free Full Text]
  26. Verkkala K, Voutilainen S, Jarvinen A, Keto P, Voutilainen P, Salmenpera M. Minimally invasive coronary artery bypass grafting: one-year follow-up. J Card Surg. 1999;14:231–237[Medline]
  27. Wiklund L, Johansson M, Bugge M, Radberg LO, Brandup-Wognsen G, Berglin E. Early outcome and graft patency in mammary artery grafting of left anterior descending artery with sternotomy or anterior minithoracotomy. Ann Thorac Surg. 2000;70:79–83[Abstract/Free Full Text]
  28. Zehr KJ, Handa N, Bonilla LF, Abel MD, Holmes DR Jr. Pitfalls and results of immediate angiography after off-pump coronary artery bypass grafting. Heart Surg Forum. 2000;3:293–299[Medline]
  29. Wiklund L, Johansson M, Brandrup-Wognsen G, Bugge M, Radberg G, Berglin E. Difficulties in the interpretation of coronary angiogram early after coronary artery bypass surgery on the beating heart. Eur J Cardiothorac Surg. 2000;17:46–51[Abstract/Free Full Text]
  30. Holubkov R, Zenati M, Akin JJ, Erb L, Courcoulas A. MIDCAB characteristics and results: the CardioThoracic Systems (CTS) registry. Eur J Cardiothorac Surg. 1998;14(Suppl 1):S25–30[Medline]
  31. Jansen EW, Borst C, Lahpor JR, Grundeman PF, Eefting FD, Nierich A, et al. Coronary artery bypass grafting without cardiopulmonary bypass using the Octopus method: results in the first 100 patients. J Thorac Cardiovasc Surg. 1998;116:60–67[Abstract/Free Full Text]
  32. Ura M, Sakata R, Nakayama Y, Arai Y, Saito T. Long-term results of bilateral internal thoracic artery grafting. Ann Thorac Surg. 2000;70:1991–1996[Abstract/Free Full Text]
  33. Barner HB, Mudd JG, Mark AL, Ahmad N, Dickens JF. Patency of internal mammary-coronary grafts. Circulation. 1976;54(Suppl):III70–73
  34. Calafiore AM, Vitolla G, Iaco AL, Fino C, Di Giammarco G, Marchesani F, et al. Bilateral internal mammary artery grafting: midterm results of pedicled versus skeletonized conduits. Ann Thorac Surg. 1999;67:1637–1642[Abstract/Free Full Text]
  35. Diegeler A, Matin M, Kayser S, Binner Ch, Autschbach R, Battellini R, et al. Angiographic results after minimally invasive coronary bypass grafting using the minimally invasive direct coronary bypass grafting (MIDCAB) approach. Eur J Cardiothorac Surg. 1999;15:680–684
  36. Calafiore AM, Di Giammarco G, Teodori G, Gallina S, Maddestra N, Paloscia L, et al. Midterm results after minimally invasive coronary surgery (LAST Operation). J Thorac Cardiovasc Surg. 1998;115:763–771[Abstract/Free Full Text]
  37. Possati G, Gaudino M, Alessandrini F, Zimarino M, Glieca F, Luciani N. Systematic clinical and angiographic follow-up of patients undergoing minimally invasive coronary artery bypass. J Thorac Cardiovasc Surg. 1998;115:785–790[Abstract/Free Full Text]
  38. Poirier NC, Carrier M, Lesperance J, Cote G, Pellerin M, Perrault LP, et al. Quantitative angiographic assessment of coronary anastomoses performed without cardiopulmonary bypass. J Thorac Cardiovasc Surg. 1999;117:292–297[Abstract/Free Full Text]
  39. Goldstein JA, Safian RD, Aliabadi D, O’Neill WW, Shannon FL, Bassett J, et al. Intraoperative angiography to assess graft patency after minimally invasive coronary bypass. Ann Thorac Surg. 1998;66:1978–1982[Abstract/Free Full Text]
  40. Gill IS, FitzGibbon GM, Higginson LA, Valji A, Keon WJ. Minimally invasive coronary artery bypass: a series with early qualitative angiographic follow-up. Ann Thorac Surg. 1997;64:710–714[Abstract/Free Full Text]
  41. Possati G, Gaudino M, Alessandrini F, Luciani N, Glieca F, Trani C, et al. Midterm clinical and angiographic results of radial artery grafts used for myocardial revascularization. J Thorac Cardiovasc Surg. 1998;116:1015–1021[Abstract/Free Full Text]
  42. Jatene FB, Pego-Fernandes PM, Hueb AC, Marques de Oliveira P, Dallan LA, Fontes R, et al. Angiographic evaluation of graft patency in minimally invasive direct coronary artery bypass grafting. Ann Thorac Surg. 2000;70:1066–1069[Abstract/Free Full Text]
  43. Puskas JD, Thourani VH, Marshall JJ, Dempsey SJ, Steiner MA, Sammons BH, et al. Clinical outcomes, angiographic patency, and resource utilization in 200 consecutive off-pump coronary bypass patients. Ann Thorac Surg. 2001;71:1477–1483[Abstract/Free Full Text]
  44. Berger PB, Alderman EL, Nadel A, Schaff HV. The IMAGE trial: frequency of early occlusion and stenosis in a left internal mammary artery to left anterior descending artery bypass graft after surgery through a median sternotomy on conventional bypass. Circulation. 1999;100:2353–2358[Abstract/Free Full Text]
  45. Mack MJ, Magovern JA, Acuff TA, Landreneau RJ, Tennison DM, Tinnerman EJ, et al. Results of immediate angiography for graft patency in minimally invasive coronary artery bypass surgery. Ann Thorac Surg. 1999;68:383–389[Abstract/Free Full Text]
  46. Mehran R. The POEM Study, TCT Presentation and TCT MD Web Site 2001. www.tctmd.com/expert_presentations. Accessed May 11, 2003
  47. Shioi K, Washizu T, Kawamura M, Abe T, Iyomasa Y. A study of sequential anastomoses in aortocoronary bypass surgery: internal configuration by the casting injection technique. Thorac Cardiovasc Surg. 1984;32:18–22[Medline]
  48. Young JN, MacMillan JC, May IA, Iverson LI, Ecker RR. Internal configuration of saphenous-coronary anastomoses as studied by the cast-injection technique. J Thorac Cardiovasc Surg. 1978;75:179–185[Abstract]
  49. Gerdisch MW, Hinkamp TJ, Ainsworth SD. Improved anastomotic quality using the U-Clip interrupted technique. Poster session, 2002 New Era Conference. Jan 5, 2002, Dana Point (CA)
  50. American College of Cardiology (ACC)/American Heart Association (AHA) ACC/AHA Guidelines for Coronary Angiography. 1999. Product code 71-0163
  51. Loop F. Technique for performance of internal mammary artery-coronary artery anastomosis. J Thorac Cardiovasc Surg. 1979;78:460–463[Medline]
  52. Anderson JG, Harshbarger W, Weng HC, Jay SJ, Anderson MM. Modeling the costs and outcomes of cardiovascular surgery. Health Care Manag Sci. 2002;5:103–111[Medline]

Related Article

Discussion
J. Thorac. Cardiovasc. Surg. 2003 126: 177-178. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Eur J Cardiothorac SurgHome page
A. K. Bigdeli, I. Kaczmarek, S. Eifert, A. Beiras-Fernandez, S. Kober, K. Nikolaou, M. Oberhoffer, and C. Vicol
Interrupted nitinol U-Clips versus standard running suture for the central arterial T-graft anastomosis: a prospective randomized study
Eur J Cardiothorac Surg, August 1, 2011; 40(2): e93 - e97.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
W. J.L. Suyker, J. P. Matonick, P. T.W. Suyker, A. Brutel de la Riviere, M. P. Buijsrogge, R. P.J. Budde, C. W.J. Verlaan, G. Pasterkamp, P. F. Grundeman, and C. Borst
S2 Connector Versus Suture: Distal Coronary Anastomosis Remodeling, Patency, and Function in the Pig
Circulation, July 4, 2006; 114(1_suppl): I-390 - I-395.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
K. E. Matschke, J. F. Gummert, S. Demertzis, U. Kappert, M. B. Anssar, F. Siclari, V. Falk, E. L. Alderman, C. Detter, H. Reichenspurner, et al.
The Cardica C-Port System: Clinical and angiographic evaluation of a new device for automated, compliant distal anastomoses in coronary artery bypass grafting surgery--A multicenter prospective clinical trial
J. Thorac. Cardiovasc. Surg., December 1, 2005; 130(6): 1645 - 1652.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
D. Y. Loisance, K. Nakashima, and M. Kirsch
Computer-assisted coronary surgery: lessons from an initial experience
Interact CardioVasc Thorac Surg, October 1, 2005; 4(5): 398 - 401.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Vicol, S. Eifert, M. Oberhoffer, P. Boekstegers, A. Knez, F. Christ, and B. Reichart
Early Clinical Results With a Magnetic Connector for Distal Coronary Artery Anastomoses
Ann. Thorac. Surg., May 1, 2005; 79(5): 1738 - 1742.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. L. Hamman and C. H. White
Interrupted distal anastomosis: the interrupted "porcupine" technique
Ann. Thorac. Surg., August 1, 2004; 78(2): 722 - 724.
[Abstract] [Full Text] [PDF]


Home page
SURG INNOVHome page
R. M. Satava
Future Trends in the Design and Application of Surgical Robots
Surgical Innovation, June 1, 2004; 11(2): 129 - 135.
[Abstract] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Randall K. Wolf
Michael P. Caskey
Allen R. Raczkowski
Mercedes K. Dullum
Dwight C. Lundell
Nan Wang
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wolf, R. K.
Right arrow Articles by Daniel, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wolf, R. K.
Right arrow Articles by Daniel, M. A.
Related Collections
Right arrow Coronary disease
Right arrow Minimally invasive surgery
Right arrowRelated Article


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS