Surgical interventions involving the suprarenal inferior vena cava (IVC) are uncommon. They are usually required after the partial or complete resection of the IVC for the management of malignant and nonmalignant diseases.,1,2 Three surgical techniques have been reported: patch angioplasty,,3 replacement with spiral saphenous vein graft,1 and replacement with extended polytetrafluoroethylene (ePTFE) grafts.,1,2,4 We report on an emergency case in which the accidentally transected suprarenal IVC was replaced with an autologous pericardial tube.
Clinical summary
A 42-year-old male man had right-sided flank pain and elevated liver enzymes. Abdominal ultrasonography and computed tomographic scan demonstrated a 5-cm right renal mass (renal cell carcinoma). Results of the metastatic workup were negative, and the patient underwent a laparoscopic right radical nephrectomy.
The laparoscopic dissection of the renal tumor was difficult and eventually complicated by severe bleeding, which could not be controlled laparoscopically. The abdomen was opened, and by manual tamponade of the undersurface of the liver and infusion of blood and intravenous fluids, blood pressure could be maintained.
The cardiothoracic surgical team was consulted. A standard median sternotomy was performed and extended to the laparotomy. The patient was placed on cardiopulmonary bypass (CPB) by cannulation of the aorta, superior vena cava, right atrium, and right femoral vein. Transesophageal echocardiography and aortic venting were used to detect and prevent air embolism in case of a patent foramen ovale. The liver was mobilized by releasing the falciform and right triangular ligaments. This provided excellent visualization of the proximal IVC, transected at the level of the undersurface of the liver. The stapled distal IVC had retracted inferiorly.
A 3 x 5-inch rectangular piece of autologous pericardium was harvested for the reconstruction. The proximal pericardiocaval anastomosis was circumferentially constructed with a running 5-0 Prolene suture (Ethicon, Inc, Somerville, NJ). The retracted distal IVC was then clamped above the renal veins, and the staple lines were resected. The distal pericardiocaval anastomosis was constructed with a 5-0 Prolene suture (Figure 1). The autologous pericardial tube was finally closed longitudinally with a 5-0 Prolene suture, creating a segment of neo-IVC. The IVC was unclamped, and flow was reestablished. The diameter of the neo-IVC was at least 2 cm at its narrowest point. The patient was weaned from CPB without difficulty.
|
Discussion
Transection of the IVC during laparoscopic nephrectomy was a true nightmare, but instant laparotomy and compression provided time to establish CPB. Normothermic CPB was used. The right atrial and femoral vein cannulation, combined with vacuum-assisted venous drainage, eliminated the need for deep hypothermia and circulatory arrest. TEE and aortic venting were used to detect and prevent air embolism. Mobilization of the liver provided exposure, and vacuum-assisted venous atrial drainage provided a bloodless field. End-to-end reanastomosis of the cava was not possible. It turned out to be technically simple and quick to create an IVC tube from a rectangular pericardial patch. Sewing to the intrahepatically retracted and fragile proximal end of the cava was possible because of good exposure and compliant tissue.
Various materials (xenopericardium, hepatic vein, omentum, peritoneofascia, ePTFE) have been used to reconstruct or replace the IVC. Autologous pericardium was our choice in this urgent situation. It is nonallogenic, biologic in origin, malleable, expandable under venous pressure, hemostatic, durable, readily available, and free. In addition, morphologic, immunohistologic, and fibrinolytic features of the autologous pericardium make it a well-suited replacement for the IVC. In their study, Iha and colleagues,5 observed that autologous pericardium differed significantly from other biologic (porcine, equine, and bovine pericardium) and synthetic (ePTFE) grafts. Their animal data showed that autologous pericardium had less endothelial lining contraction and subendothelial fibrosis, along with better fibrinolytic activity. This has led us to believe that an endothelialized autologous pericardial tube graft would be well suited to the low-flow system of the IVC because of its low thrombogenicity and low risk of contracture and narrowing.
Patch angioplasty with autologous pericardium was originally described in patients with Budd-Chiari syndrome.,3 When replacement of the IVC was required, however, ePTFE tube grafts were more commonly used.,1,2 These grafts were patent up to 5 years.1 Our main concern relating to the choice of ePTFE was immediate hemostasis. Spiral saphenous vein grafts are not commonly used for IVC replacement and are time consuming, and early patency rates have been poor.,1 The approach described here (management of CPB and use of autologous pericardium for the reconstruction) has also been successfully used for elective renal tumor resection with IVC tumor thrombus.
References
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||