JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Stefano Saccani
Francesco Nicolini
Andrea Agostinelli
Tiziano Gherli
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Saccani, S.
Right arrow Articles by Gherli, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Saccani, S.
Right arrow Articles by Gherli, T.
Related Collections
Right arrow Great vessels

J Thorac Cardiovasc Surg 2004;127:1821-1823
© 2004 The American Association for Thoracic Surgery


Brief communication

New technologies for the treatment of type A aortic dissection: A case report

Stefano Saccani, MDa, Francesco Nicolini, MDa,*, Bruno Borrello, MDa, Andrea Agostinelli, MDa, Pietro Larini, MDb, Carla Marcato, MDb, Tiziano Gherli, MDa

a Cardiac Surgery Department, University of Parma, Parma, Italy
b Radiology Department, University of Parma, Parma, Italy

Received for publication November 24, 2003; revisions received December 31, 2003; accepted for publication January 13, 2004.

* Address for reprints: Francesco Nicolini, MD, Cattedra e Divisione di Cardiochirurgia, Università degli Studi, Via A. Gramsci 14, 43100 Parma, Italy
francesconicolini{at}libero.it

Aortic arch replacement in the treatment of type A aortic dissection is justified in emergency settings to prevent later complications,1 even if it is technically demanding and affected by mortality and morbidity.2,3 Evolution of residual false lumen remains unpredictable, requiring further high-risk surgical procedures. We report a case of type A aortic dissection treated with ascending aortic replacement associated with a new stent graft positioned in the aortic arch and completed with thoracic endovascular stent graft placement.

Clinical summary

A 78-year-old woman was admitted for acute type A aortic dissection. Preoperative transesophageal echocardiography showed a primary tear located above the aortic cusps and extending to the descending thoracic aorta. Cardiopulmonary bypass was established between the right subclavian artery and the right atrium. At mild hypothermia, the ascending aorta was crossclamped, and cold blood cardioplegia was administered through the coronary ostia. The proximal aortic stump was reconstructed with continuous mattress sutures and Teflon collars after gelatin-resorcin-formol glue application to the false channel. At a nasopharyngeal temperature of 24°C, general circulation was arrested, and cerebral protection was obtained by means of right common carotid artery perfusion at a rate of 10 mL · kg–1 · min–1 through the right subclavian artery. Another tear was found near the origin of the brachiocephalic trunk. The Djumbodis dissection system (Saint Come-Chirurgie, Marseille, France), 9 cm long, was inserted in the aortic arch and fixed to the aortic wall with 4 transfixed stitches. The device consists of an uncovered stent made of Steel 316 L provided in 3 lengths (4, 9, and 14 cm) and mounted on a compliant balloon (Figure 1). The balloon is inflated to adapt the stent to the shape of the aortic arch and to coapt aortic layers. The deployed device presents a large-meshed web and can be superimposed at the origin of the epiaortic vessels without any danger of obstruction. A 30° 5-mm endoscope positioned in the aortic arch allowed us to control the correct deployment of the Djumbodis system. The distal end of a Dacron graft was anastomosed to the distal aortic stump and reconstructed with the same technique as used with the proximal one. Extracorporeal circulation was restored, and proximal anastomosis of the Dacron graft was performed during rewarming of the patient. Selective antegrade cerebral perfusion time was 28 minutes, and aortic arch inspection requires 4 minutes of total circulatory arrest. Contrast-enhanced computed tomographic (CT) scanning showed no patent false lumen in the aortic arch. The patient was discharged in an asymptomatic state 12 days after the operation. At 2 months' follow-up CT scanning, a dilation of the false lumen with an aortic isthmian pseudoaneurysm was found: the patient underwent endovascular thoracic stent graft insertion (2 segments, 32 x 32 x 230; Talent World Medical Manufacturing Corp, Sunrise, Fla) through the left femoral artery. Stent grafts were proximally positioned with partial overlapping to the distal end of the Djumbodis dissection system and deployed distally up to the origin of the celiac trunk (Figure 2). The postoperative course was uneventful.



View larger version (150K):
[in this window]
[in a new window]
 
Figure 1. Djumbodis dissection system consisting of an uncovered stent made of Steel 316 L provided in 3 lengths (4, 9, and 14 cm).

 


View larger version (104K):
[in this window]
[in a new window]
 
Figure 2. A, Postoperative chest radiograph showing complete correction after placement of a Djumbodis stent and deployment of a thoracic aortic stent graft. B, Postoperative CT scan after complete correction.

 
Discussion

The treatment of a type A aortic dissection with aortic arch replacement is reserved for situations in which an intimal tear is located in the transverse arch. Ascending aorta replacement alone remains at considerable risk of future complications (50%-70% rate of patent false lumen in the arch and 23% rate of redo).1 Recent reports have shown encouraging results in extended aortic replacement in acute type A dissection, even if this procedure remains a complex technique with a high mortality rate.2,3 Roux and colleagues4 have reported the use of surgical technique plus stent positioning to treat 2 patients affected by type A aortic dissection. In this patient we used a 2-step combined technique: first, positioning of the Djumbodis stent with traditional ascending aorta replacement to avoid surgical aortic arch correction with a relatively easy and reproducible technique; second, transfemoral artery stent grafting of the thoracic aorta to correct pseudoaneurysm and residual dissection. It appears to be a useful procedure mainly in high-risk situations, such as elderly patients with comorbidities in whom aortic arch replacement has a prohibitive surgical risk. The Djumbodis system has also facilitated distal aortic procedures because the long steel stent permits a safe proximal landing zone for deployment of thoracic aortic stent grafts. Control CT scans 2 and 5 months after the last procedure showed the perfect position of the Djumbodis and thoracic stent grafts; the aortic arch was not dilated, and the resulting pseudoaneurysm false lumen was thrombosed. At 7 months' follow-up, the patient is alive and asymptomatic. This combined surgical and endovascular approach might be a valuable adjunct to the treatment of type A aortic dissection, even if midterm follow-up studies will define the clinical outcome of patients subjected to combined solutions for complex aortic disease.

Footnotes

Dr Borrello was supported by a research grant from Compagnia di S. Paolo-Torino and MIUR.

References

  1. Bachet JE, Termignon J, Dreyfus G, Goudot B, Martinelli L, Piquois A, et al. Aortic dissection: prevalence, cause, and results of late reoperations. J Thorac Cardiovasc Surg. 1994;108:199–206[Abstract/Free Full Text]
  2. Kazui T, Yamashita K, Washiyama N, Terada H, Bashar AHM, Suzuki T, et al. Impact of an aggressive surgical approach on surgical outcome in type A aortic dissection. Ann Thorac Surg. 2002;74(suppl):S1844–1847[Abstract/Free Full Text]
  3. Urbanski PP, Siebel A, Zacher M, Hacker RW. Is extended aortic replacement in acute type A dissection justifiable? Ann Thorac Surg. 2003;75:525–529[Abstract/Free Full Text]
  4. Roux D, Brouchet L, Concina P, Elghobary T, Glock Y, Fournial G. Type-A acute aortic dissection: combined operation plus stent management. Ann Thorac Surg. 2002;73:1616–1618[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. Leobon, D. Roux, S. Saccani, A. Mugniot, F. Muscari, Y. Glock, and G. Fournial
Type A aortic dissection: New surgical strategy using intra-operative stenting
J. Thorac. Cardiovasc. Surg., February 1, 2006; 131(2): 482 - 483.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Stefano Saccani
Francesco Nicolini
Andrea Agostinelli
Tiziano Gherli
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Saccani, S.
Right arrow Articles by Gherli, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Saccani, S.
Right arrow Articles by Gherli, T.
Related Collections
Right arrow Great vessels


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS