JTCS Sign the Guestbook
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Cornelius Borst
Paul F. Gründeman
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Budde, R. P.J.
Right arrow Articles by Gründeman, P. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Budde, R. P.J.
Right arrow Articles by Gründeman, P. F.
Related Collections
Right arrow Minimally invasive surgery

J Thorac Cardiovasc Surg 2005;129:1078-1083
© 2005 The American Association for Thoracic Surgery


Evolving Technology

Detection of construction errors in ex vivo coronary artery anastomoses by 13-MHz epicardial ultrasonography

Ricardo P.J. Budde, MSc, Rudy Meijer, Thomas C. Dessing, MSc, Cornelius Borst, MD, PhD, Paul F. Gründeman, MD, PhD*

Heart Lung Center Utrecht, University Medical Center, Utrecht, The Netherlands.

Received for publication July 4, 2004; revisions received September 1, 2004; accepted for publication September 7, 2004.

* Address for reprints: Paul F. Gründeman, MD, PhD, Associate Professor, Cardiothoracic and Vascular Research, Large Animals, University Medical Center Utrecht (Room G02.523), Heidelberglaan 100, 3584 CX Utrecht, The Netherlands. (E-mail: p.f.grundeman{at}hli.azu.nl).


    Abstract
 Top
 Abstract
 Material and methods
 Results
 Discussion
 Limitations
 Conclusion
 References
 
OBJECTIVE: Intraoperative detection of suboptimal coronary anastomoses allows revision before chest closure. We evaluated an epicardial 13-MHz ultrasound minitransducer as a means to detect three different coronary anastomosis construction errors.

METHODS: In total, 120 internal thoracic arter-t-coronary artery anastomoses were constructed correctly (n = 60) or incorrectly (n = 60) with one technical error: suture crossover, purse-string or deep toe stitch (n = 20 each). Anastomoses were performed on ex vivo pressure-perfused porcine (96 anastomoses) and human hearts (24 anastomoses). Two blinded observers scanned and scored the anastomoses with epicardial ultrasonography. In 24 human and 24 porcine anastomoses, angiograms were made of 24 correct and 24 incorrect anastomoses and scored by two other blinded observers. Angioscopy and cast injection served as a reference.

RESULTS: Overall, 119 of 120 anastomoses were accurately scored as correct or incorrect within a median of 67 seconds (8–381 seconds) by both observers (sensitivity 0.98, specificity 1.00, {kappa} 1.00 (1.00, 1.00, and 1.00 in angiography subset, respectively). One deep toe stitch that induced outflow corner stenosis was spotted by both observers but regarded as insignificant and thus inaccurately scored as correct. In 5 anastomoses, unintended irregularities were detected. By angiography, anastomoses were accurately scored with a sensitivity of 0.75 and a specificity of 0.81 (P < .001 vs ultrasonography) and {kappa} of 0.54. Angioscopy and cast confirmed ultrasonographic findings and did not reveal irregularities other than detected by ultrasonography.

CONCLUSION: Ex vivo epicardial 13-MHz ultrasonography allowed rapid and accurate evaluation of coronary anastomoses and detected technical construction errors with higher sensitivity and specificity than angiography.


There is concern about the increased risk of anastomosis construction errors in (minimally invasive) off-pump coronary artery bypass grafting (CABG) because the suturing process is technically more demanding than surgery on the arrested heart.1 In on-pump CABG, total occlusion or stenosis greater than 50% is seen in as many as 9% of grafts at short-term angiographic follow-up.1 Angioscopy reveals irregularities and technical errors that include purse-string effect, intimal flaps, thrombus formation, and misplaced sutures in as many as 24% of anastomoses.2,3

An intraoperative technique to assess anastomotic quality could improve patency rates in all approaches to CABG, because suboptimal anastomoses might be revised before chest closure.4 Currently, angiography is the gold standard, but it is rarely used intraoperatively.5 Epicardial ultrasonography for anastomosis visualization and assessment was described in the 1980s.6 Despite promising results,6 technical limitations prevented widespread use. Recently, we described a new high-frequency epicardial ultrasound minitransducer (15 x 9 x 6 mm) for assessment of the left anterior descending coronary artery (LAD) in patients7 and geometry assessment of anastomoses.8,9 Because of its small size and high frequency (up to 13 MHz in B-mode), this minitransducer has potential for routine intraoperative assessment of anastomoses at all locations on the heart.

The aim of this study was to investigate the ability of two blinded observers to detect and characterize three different standardized construction errors in coronary anastomoses on ex vivo hearts with the 13 MHz minitransducer and compare the results against the gold standard of angiography.


    Material and methods
 Top
 Abstract
 Material and methods
 Results
 Discussion
 Limitations
 Conclusion
 References
 
Ex vivo porcine and postmortem human hearts
On 46 ex vivo porcine hearts, 96 internal thoracic artery (ITA)–to-LAD anastomoses were constructed. On 4 isolated postmortem human hearts, a total of 24 anastomoses were constructed on the LAD, diagonal branches, right coronary artery, and circumflex coronary artery. All grafts were porcine ITAs. The coronary arteries were cannulated proximally to pressurize (80 mm Hg) the anastomoses with saline solution through a Langendorff setup.

Anastomosis construction
All 120 anastomoses were randomly constructed by a single investigator (R.P.J.B.) deliberately either correctly (n = 60) or with a single, standardized construction error (n = 60), either suture crossover, purse-string, or deep toe stitch (n = 20 each). The distribution of anastomosis types is summarized in Table 1. The crossover anastomosis was constructed by interlocking two suture bites on opposite sides of the arteriotomy approximately a third of the anastomotic orifice length from the toe. The purse-string anastomosis was made by pulling heavily on the suture ends before fashioning the suture. In the deep toe suture bite anastomosis, the suture was passed through the posterior wall of the coronary artery at the toe.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Number and distribution of anastomosis types
 
Anastomotic sites on the porcine LAD were chosen at random. In the human hearts (24 anastomoses), the anastomosis was deliberately placed in sites with (n = 12) and without (n = 12) atherosclerotic disease, as determined by digital palpation and epicardial ultrasonographic scanning (Table 1).

Ultrasonographic equipment
As in our previous work,8,9 a commercially available, high-frequency (up to 13 MHz in B-mode), linear-array minitransducer (15 x 6 x 9 mm; Aloka Co, Ltd, Tokyo, Japan) was used. The image scan width was 10 mm. The minitransducer was placed in a handling tool that could be held like a pencil.7 Imaging was performed with an Aloka SSD 5000 Prosound ultrasound system (Aloka Co, Ltd). Ultrasound transmission gel (Parker Laboratories, Fairfield, NJ) was applied directly onto the anastomosis for proper contact.

Ultrasonographic scanning
Two observers (R.M. and T.C.D.) blinded to the anastomosis type scanned and scored all anastomoses as described. Both had extensive experience in echocardiographic scanning of coronary anastomoses. Scan time needed to obtain sufficient information for scoring was recorded.

Angiography
In a subgroup of 24 porcine anastomoses (12 correct, 4 of each type of error) and all 24 human heart anastomoses (12 correct, 4 of each type of error), angiography (C-arm, Pulsera; Philips Nederland BV Medical Systems, Eindhoven, The Netherlands) of the graft and anastomosis was performed in at least two different oblique projections by selectively injecting contrast media through the ITA (Table 1). Two independent observers (J.M.P.G.E. and C.B.) blinded to the anastomosis type scored the angiograms as described.

Anastomosis scoring by ultrasonography and angiography
Anastomoses were scored as either correct or a construction error. The location and appearance of detected technical errors and irregularities were indicated in a schematic drawing of the anastomosis. The location was categorized in one or more of the following categories: ITA, anastomotic orifice, inflow corner, outflow corner, and recipient coronary artery.

Angioscopy and cast
During perfusion, a 2.4-mm angioscope (11281A; Karl Storz GmbH & Co, Tüttlingen, Germany) was introduced through the free proximal end of the ITA to visualize the anastomosis.2,3 A polyvinylsiloxane impression material (Kerr Co, Romulus, Mich) was injected into the ITA to fill the coronary artery, the anastomosis, and the ITA itself. The resulting 3-dimensional cast of the anastomosis was removed from the vessels after hardening and visually inspected at 3.5x magnification. Angioscopic and cast findings combined served as a reference for ultrasonographic and angiographic findings.

Statistical analysis
The {kappa} value was calculated to rate the agreement between observers and interpreted according to Landis and Koch.10 Sensitivity and specificity were calculated for the scoring of both observers combined. Scores were compared with the {chi}2 test. Scan times are presented as median with range and were compared with the Wilcoxon rank sum test.


    Results
 Top
 Abstract
 Material and methods
 Results
 Discussion
 Limitations
 Conclusion
 References
 
Anastomosis construction
External inspection could not discriminate incorrect from correct anastomoses.

Ultrasonographic scanning and scoring
All 120 anastomoses were easily visualized within a median of 67 seconds (range 8–381 seconds). Visualization of the porcine anastomoses (median 61 seconds, range 8–381 seconds) was faster than that of the human anastomoses (median 92 seconds, range 14–256 seconds, P < .001). Representative ultrasonographic images of a control anastomosis are presented in Figure 1.


Figure 1
View larger version (51K):
[in this window]
[in a new window]
 
Figure 1. Correctly constructed control anastomosis: transverse (left panels) and longitudinal ultrasonographic (right panels) images. Dist, Distal; Prox, proximal.

 
Both observers accurately scored 119 of 120 (99%; Table 2) anastomoses as correct or construction error (sensitivity 0.98, specificity 1.00, {kappa} 1.00). In most anastomoses, the presence of a construction error was detected directly on first visualization of the anastomosis. In the single inaccurately scored anastomosis (deep toe stitch anastomosis), slight narrowing of the outflow corner was spotted but considered insignificant and thus scored as correct by both observers.


View this table:
[in this window]
[in a new window]
 
TABLE 2. Scoring results of both observers combined
 
Each of the construction errors had a distinct appearance on the ultrasonographic image. The crossover anastomosis had an echodense spot in the anastomotic orifice (Figure 2). In the purse-string anastomosis, the anastomotic orifice was narrowed (Figure 3). In the deep toe stitch anastomosis, narrowing of the outflow corner was seen (Figure 4). All errors were seen in both the longitudinal and transverse scan planes.


Figure 2
View larger version (42K):
[in this window]
[in a new window]
 
Figure 2. Suture crossover anastomosis: panels from left to right, transverse and longitudinal ultrasonographic images, angiogram, and angioscopic image taken from ITA toward outflow corner. Note in the longitudinal ultrasonographic image the suture traversing the anastomotic orifice twice (arrow). The transverse image was taken at the level of the overcrossing suture. The anastomosis appeared normal on the angiogram. Dist, Distal; Prox, proximal.

 

Figure 3
View larger version (39K):
[in this window]
[in a new window]
 
Figure 3. Purse-string anastomosis: panels from left to right, transverse and longitudinal ultrasonographic images, angiogram, and cast. Note in the transverse and longitudinal ultrasonographic images severe narrowing of the anastomotic orifice (arrow) and the small resulting lumen (arrowhead). Dist, Distal; Prox, proximal.

 

Figure 4
View larger version (64K):
[in this window]
[in a new window]
 
Figure 4. Deep toe stitch anastomosis: longitudinal ultrasonographic image (left panel) and angioscopic image from ITA toward outflow corner (right panel). Note in the angioscopic image the suture passing through the posterior wall of the LAD (arrow). Dist, Distal; Prox, proximal.

 
One purse-string anastomosis appeared the same as a control anastomosis on ultrasonography and was scored as such by both observers. In 5 anastomoses, unintended irregularities were detected by both observers: outflow corner narrowing with LAD disruption in a purse-string anastomosis, additional purse-string effect of various degrees in 3 anastomoses, and an inflow corner narrowing in 1 anastomosis. All these findings were confirmed by angioscopy and cast and analyzed as such.

In several anastomoses, tissue was detected in the anastomosis only by the second observer. It is conceivable that sometimes tissue was introduced during the angioscopy procedure that was performed between scans by the two observers. This is a known complication of angioscopy.2 Those findings were not used in the analysis.

In all anastomoses scored as construction error, the error location was accurately scored by both observers ({kappa} 1.0). The sort of error was correctly identified in 58 of 60 anastomoses by observer 1 and in 54 of 60 anastomoses by observer 2 (93% overall).

Presence of calcifications in the human hearts was not a confounding factor for image interpretation. Calcifications showed clear echocardiographic shadowing (Figure 5), making them easy to discriminate from construction errors.


Figure 5
View larger version (133K):
[in this window]
[in a new window]
 
Figure 5. Composite longitudinal ultrasonographic image of calcification in a purse-string anastomosis (arrowhead). Note its bright appearance and distinct echo shadowing. In the anastomotic orifice, the lateral wall can be seen because of narrowing by the purse-string effect (arrow). Dist, Distal; Prox, proximal.

 
Angiography
Of the 48 anastomoses in which angiography was performed, 36 and 39 were accurately scored as correct or construction error by observers 3 and 4, respectively (sensitivity 0.75, specificity 0.81, {kappa} 0.54; Table 2). In these 48 anastomoses, the sensitivity and specificity of ultrasonography were both 1.0 (P < .001 vs angiography). The suture crossover error proved to be particularly difficult to detect by angiography (Figure 2). Of the inaccurately scored anastomoses, 5 were inaccurately scored by both observers.

The error location in anastomoses accurately scored as construction error was accurately identified in 10 of 18 and 14 of 18 anastomoses (68% accurate overall) by observers 3 and 4, respectively. Three anastomoses were inaccurately scored because of the presence or presumed presence of plaque and calcification.

Angiographically, the specific kind of construction error could not be determined reliably. Only a distinction between outflow corner and orifice narrowing could be made.

Angioscopy and cast
Angioscopy and cast findings corresponded with ultrasonographic findings, and no irregularities other than those detected by ultrasonography were noted.


    Discussion
 Top
 Abstract
 Material and methods
 Results
 Discussion
 Limitations
 Conclusion
 References
 
The principal findings of this study were as follows: (1) Epicardial ultrasonography enabled detection of construction errors in coronary anastomoses with significantly higher sensitivity and specificity than angiography. (2) With epicardial ultrasonography, the location and type of error could be accurately determined in 100% (vs 68% by angiography) and 93%, respectively, of the anastomoses in which an error was detected. (3) Ultrasonographic scanning required only a median of 67 seconds for assessment of an anastomosis.

Anastomosis quality control
With the advent of off-pump and minimally invasive CABG, there has been a renewed interest in techniques for intraoperative assessment of distal anastomosis quality.4,11,12 Currently, only graft flow measurement is used on a large scale.11 Graft flow measurement, however, can only detect severe stenosis (>75%) and provides no information about its location. Furthermore, there is no clear cutoff point for adequate graft flow, and thus it may underestimate the number of suboptimal anastomoses. For various reasons, the gold standard of angiography is not used frequently, most importantly because it is invasive, not readily available in the operating room, and time-consuming.5

The potential of epicardial ultrasonography for coronary anastomosis assessment was recognized almost 20 years ago.6 Technical transducer limitations, however, have prevented widespread clinical introduction. The current minitransducers allow easier access. To date, no detailed evaluation has been reported regarding the ability of epicardial ultrasonography to detect and characterize different technical errors in coronary anastomoses relative to the gold standard of angiography.

In the subgroup of 48 anastomoses evaluated with angiography, epicardial ultrasonography enabled detection of construction errors with significantly higher sensitivity (1.00) and specificity (1.00) than achieved with angiography (0.75 and 0.81, respectively). When calculated from all 120 anastomoses in the study, the sensitivity and specificity of epicardial ultrasonography were 0.98 and 1.00, respectively.

In addition, epicardial ultrasonography enabled discrimination between narrowing caused by suture errors or by calcifications, that present with a distinct echo shadowing (Figure 5). This was not possible with angiography.

Anastomosis evaluation with epicardial ultrasonography required only a median of 92 seconds in human anastomoses, which is clinically acceptable. In most cases, the detection of the error was instantaneous, and subsequent scanning time was spent characterizing the error and looking for additional irregularities. Clinically, revision would be performed directly after a serious error was spotted.

As we have shown before,7 the minitransducer can also be used to locate the coronary artery and select the optimal anastomotic site. Combined with its use for anastomotic quality assessment and possibly epiaortic scanning as well, the ultrasound minitransducer may prove a multipurpose diagnostic tool to improve the quality of CABG surgery.

A concern with the use of epicardial ultrasonography for anastomosis quality assessment is that image interpretation is subjective and operator dependent.4 In this study, however, the two observers scored all anastomoses identically with regard to the presence of a construction error ({kappa} 1.0), indicating an almost perfect agreement,10 whereas the {kappa} for angiography was 0.54, indicating only moderate agreement. The observers did have extensive previous experience with the interpretation of ultrasonographic images of anastomoses. Preferably, the surgeon would be trained in a laboratory setting, including scanning of anastomoses on ex vivo hearts perfused with saline solution and image interpretation of off-line images on a computer. This might take a couple of hours. Alternatively, the surgeon might teach himself or herself by starting to acquire images during cardioplegic arrest and later studying the images off-line. This would permit peer review by a radiologist.


    Limitations
 Top
 Abstract
 Material and methods
 Results
 Discussion
 Limitations
 Conclusion
 References
 
The experimental setup in ex vivo hearts presents several limitations relative to the in vivo situation. First, exposure of the anastomosis for ultrasonographic scanning was not hampered by motion artifacts. We have experience, however, with scanning ITA-LAD anastomoses on the beating porcine heart. Image quality has been comparable to that in this study and has allowed successful detection of anastomotic irregularities in comparable scan times.9 Second, buildup of angiographic contrast in the ex vivo hearts as a result of lack of washout made the angiograms less easy to interpret. Third, 96 of 120 anastomoses were constructed on healthy porcine coronary vessels. However, 12 of the 24 human anastomoses were deliberately constructed in a diseased part of the coronary artery. The plaque and calcification did not impair the ability to assess the anastomosis by ultrasonography.


    Conclusion
 Top
 Abstract
 Material and methods
 Results
 Discussion
 Limitations
 Conclusion
 References
 
With an epicardial 13-MHz ultrasound minitransducer, three technical errors in coronary anastomoses constructed ex vivo were detected in about 1 minute with a higher sensitivity (1.00) and specificity (1.00) than with angiography (0.75 and 0.81, respectively). Epicardial ultrasonography is a promising technique for routine, clinical, intraoperative, noninvasive quality control of coronary anastomoses.


    Acknowledgments
 
We acknowledge the technical contributions of C. W. J. Verlaan and M. Emons and the statistical advice of M. Schipper, PhD. We thank H. Vosmeer for making the angioscope available. Special thanks to J. M. P. G. Ernst, MD, PhD, for scoring the angiograms.


    References
 Top
 Abstract
 Material and methods
 Results
 Discussion
 Limitations
 Conclusion
 References
 

  1. Berger PB, Alderman EL, Nadel A, Schaff HV. Frequency of early occlusion and stenosis in a left internal mammary artery to left anterior descending artery bypass graft after surgery through a median sternotomy on conventional bypass. Benchmark for minimally invasive direct coronary artery bypass. Circulation. 1999;100:2353-2358.[Abstract/Free Full Text]
  2. Chaux A, Lee ME, Blanche C, Kass RM, Sherman TC, Hickey AE, et al. Intraoperative coronary angioscopy. Technique and results in the initial 58 patients. J Thorac Cardiovasc Surg. 1986;92:972-976.[Abstract]
  3. Siegel SB, White GH, Colman PD, Nelson RJ. Intraoperative angioscopy for coronary bypass surgery. J Card Surg. 1995;10:210-220.[Medline]
  4. Wolf RK, Falk V. Intraoperative assessment of coronary artery bypass grafts. [editorial] J Thorac Cardiovasc Surg. 2003;126:634-637.[Free Full Text]
  5. Izzat MB, Khaw KS, Atassi W, Yim AP, Wan S, El-Zufari MH. Routine intraoperative angiography improves the early patency of coronary grafts performed on the beating heart. Chest. 1999;115:987-990.[Abstract/Free Full Text]
  6. Hiratzka LF, McPherson DD, Brandt 3rd B, Lamberth Jr WC, Sirna S, Marcus ML, et al. The role of intraoperative high-frequency epicardial echocardiography during coronary artery revascularization. Circulation. 1987;76(Suppl V):V33-V38.[Medline]
  7. Eikelaar JH, Meijer R, van Boven WJ, Klein P, Gründeman PF, Borst C. Epicardial 10-MHz ultrasound in off-pump coronary bypass surgery. a clinical feasibility study using a minitransducer. J Thorac Cardiovasc Surg. 2002;124:785-789.[Abstract/Free Full Text]
  8. Dessing TC, Budde RP, Meijer R, Bakker PF, Borst C, Gründeman PF. Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound. Eur J Cardiothorac Surg. 2004;26:257-261.[Abstract/Free Full Text]
  9. Budde RP, Dessing TC, Meijer R, Bakker PF, Borst C, Gründeman PF. Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses. Interactive Cardiovascular and Thoracic Surgery. DOI:0.1016/j.icvts.2004.07.009, August 5, 2004. http://www.icvts.org.pdf/icvts380.pdf..
  10. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174.[Medline]
  11. D’Ancona G, Karamanoukian HL, Ricci M, Schmid S, Bergsland J, Salerno TA. Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting. Eur J Cardiothorac Surg. 2000;17:287-293.[Abstract/Free Full Text]
  12. Reuthebuch O, Haussler A, Genoni M, Tavakoli R, Odavic D, Kadner A, et al. Novadaq SPY. intraoperative quality assessment in off-pump coronary artery bypass grafting. Chest. 2004;125:418-424.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. K. Hol, K. Andersen, H. Skulstad, P. S. Halvorsen, P. S. Lingaas, R. Andersen, J. Bergsland, and E. Fosse
Epicardial Ultrasonography: A Potential Method for Intraoperative Quality Assessment of Coronary Bypass Anastomoses?
Ann. Thorac. Surg., September 1, 2007; 84(3): 801 - 807.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. P.J. Budde, P. F. A. Bakker, R. Meijer, C. Borst, and P. F. Grundeman
Ultrasound Mini-Transducer with Malleable Handle for Coronary Artery Surgery
Ann. Thorac. Surg., January 1, 2006; 81(1): 322 - 326.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. P.J. Budde, W. J.L. Suyker, P. T.W. Suyker, C. W.J. Verlaan, R. Meijer, C. Borst, and P. F. Grundeman
Quality assessment of distal S2AS connector anastomosis by 13MHz epicardial ultrasound
Eur. J. Cardiothorac. Surg., December 1, 2005; 28(6): 833 - 837.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Cornelius Borst
Paul F. Gründeman
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Budde, R. P.J.
Right arrow Articles by Gründeman, P. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Budde, R. P.J.
Right arrow Articles by Gründeman, P. F.
Related Collections
Right arrow Minimally invasive surgery


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS