|
|
||||||||
J Thorac Cardiovasc Surg 2005;129:1395-1404
© 2005 The American Association for Thoracic Surgery
Cardiopulmonary Support and Physiology |
a Brody School of Medicine at East Carolina University, Pitt County Memorial Hospital, Greenville, NC
b Advocate Christ Medical Center, Oak Lawn, Ill
c Columbia Presbyterian Hospital, New York, NY
d University of Southern California, Los Angeles, Calif
e Hoag Heart and Vascular Institute, Hoag Memorial Hospital, Newport Beach, Calif
Received for publication May 1, 2003; revisions received June 21, 2004; accepted for publication July 9, 2004. * Address for reprints: L. Wiley Nifong, MD, Department of Surgery, East Carolina University School of Medicine, 600 Moye Blvd, LSB 248, Greenville, NC 27858 (Email: nifongL{at}mail.ecu.edu).
| Abstract |
|---|
|
|
|---|
METHODS: After institutional review board approval, informed consent was obtained. Patients had moderate to severe mitral regurgitation. Operative technique included peripheral cardiopulmonary bypass, a 4- to 5-cm right minithoracotomy, a transthoracic aortic crossclamp, and antegrade cardioplegia. The successful study end point was grade 0 or 1 mitral regurgitation by transthoracic echocardiography at 1 month after surgery.
RESULTS: Valve repairs included quadrangular resections, sliding plasties, edge-to-edge approximations, and both chordal transfers and replacements. The average age was 56.4 ± 0.09 years (mean ± SEM). There were 77 (68.8%) men and 35 (31.2%) women. Valve pathology was myxomatous degeneration in 105 (91.1%), and 103 (92.0%) had type II leaflet prolapse. Leaflet repair times averaged 36.7 ± 0.2 minutes, with annuloplasty times of 39.6 ± 0.1 minutes. Total robot, aortic crossclamp, and cardiopulmonary bypass times were 77.9 ± 0.3 minutes, 2.1 ± 0.1 hours, and 2.8 ± 0.1 hours, respectively. On 1-month transthoracic echocardiography, 9 (8.0%) had grade 2 mitral regurgitation, and 6 (5.4%) of these had reoperations (5 replacements and 1 repair). There were no deaths, strokes, or device-related complications.
CONCLUSIONS: Multiple surgical teams performed robotic mitral valve repairs safely early in development of this procedure, with a reoperation rate of 5.4%. Advancements in robotic design and adjunctive technologies may help in the evolution of this minimally invasive technique by decreasing operative times.
Telemanipulation of tissues has become possible through recent advances in surgical robotic systems, which provide a combination of 3-dimensional vision and microinstrumentation providing a full range of motion in tiny spaces, no tremor, and motion scaling. In 1998, Carpentier and Mohr independently performed the first MV repairs by using an early prototype of the da Vinci surgical system (Intuitive Surgical, Inc, Sunnyvale, Calif).6,7 Mohr and colleagues8 then reported the first operative series of robotic MV procedures. Mehmnesh and colleagues9 have performed the only closed-chest endoscopic MV repair to date. Using the Zeus system, Grossi and colleagues10 performed a posterior leaflet repair in 2000. A month later, with the da Vinci system, Chitwood and colleagues11 performed a posterior leaflet resection with reconstruction and implanted an annuloplasty band.
A phase I clinical trial (G000023) approved by the Food and Drug Administration (FDA) was begun at East Carolina University (ECU) to evaluate safety and efficacy in robot-assisted MV repair surgery. In this initial series, patients were between 18 and 80 years of age and had isolated grade 3/4 mitral regurgitation. All 10 patients had successful MV repairs, with no deaths or complications.12 The FDA extended this trial to 20 patients to provide training observation at ECU in preparation for the forthcoming phase II trial. In October 2000, an FDA-approved multicenter phase II trial (G000295) was initiated to evaluate the system in a variety of institutional environments. This report describes results from this 10-center multicenter phase II clinical trial evaluating the da Vinci surgical system in 112 MV repair patients.
| Patients and Methods |
|---|
|
|
|---|
|
|
da Vinci instrument arms (7 mm) were inserted through two 10-mm trocar incisions. The right instrument arm generally was positioned 4 to 6 cm lateral to the chest incision in either the fourth or fifth ICS. The left instrument arm was positioned medial and cephalad to the right arm in the second or third ICS. Arm trocar sites were maintained 6 cm apart at chest entry. Care was taken to establish optimal arm-vector alignment with the valve plane to ensure full, unrestricted instrument excursion. A specialized 30° stereoscopic endoscope was placed through the medial portion of the minithoracotomy. A patient-side surgeon facilitated instrument changes and needle/suture passing and retrieval. All valve repair and annuloplasty sutures were placed with the da Vinci robot. All left atriotomies were closed either under direct vision or with videoscopic assistance. After crossclamp release, meticulous intracardiac deairing and weaning from cardiopulmonary bypass (CPB) was performed, and pacing wires and chest tubes were inserted. In each patient, a postrepair TEE was performed for analysis by the outside echocardiographic core laboratory.
Clinical information for enrolled patients was collected and verified by trained study monitors. All data were abstracted onto FDA case report forms and entered into a database. Case report forms were completed for the following points: (1) before surgery, (2) during surgery, (3) after surgery (including the intensive care unit), (4) at discharge, and (5) 1 month after surgery. All adverse events were recorded and reported immediately. All echocardiograms were reviewed by an independent core laboratory (Hoag Memorial Hospital, Newport Beach, Calif). These included preoperative TTE, intraoperative TEE before and after each MV repair, and a TTE 1 month after surgery. Intraoperative TEE was performed before institution of CPB and after the valve repair after weaning from bypass. The core laboratory was blinded to echocardiogram findings at each site, and individual sites were blinded to the core laboratory findings. Significant discrepancies were resolved by reanalysis of the echocardiography tapes in question. The core laboratory assessment was used in the final analysis.
All final data analyses were conducted with SAS (SAS Institute, Cary, NC). All continuous variables were analyzed with nonparametric tests, the Wilcoxon ranked sum test for 2-group comparisons, and Kruskal-Wallis analysis of variance for multigroup comparisons. Categorical data were analyzed with
2 tests. Data are shown as mean ± SD and range.
| Results |
|---|
|
|
|---|
The average age of all patients was 56.4 ± 10.2 years, with a range of 37 to 81 years. The average body mass index was 26.6 ± 4.0 kg/m2 (18.5 to 40.9 kg/m2). Of the 112 patients, 77 were male (68.8%), and 102 (91.1%) were white. The most prevalent comorbid conditions were a family history of coronary artery disease (n = 59; 52.7%), smoking (n = 39; 34.8%), cardiac arrhythmias (n = 33; 29.5%), hypertension (n = 39; 34.8%), congestive heart failure (n = 22; 19.6%), and cardiomegaly (n = 20; 17.9%). There was a significantly lower prevalence of peripheral vascular disease (n = 5; 4.5%), infectious endocarditis (n = 6; 5.6%), diabetes (n = 3; 2.6%), and rheumatic fever (n = 6; 5.6%). No statistically significant differences in demographic characteristics were found among the patients enrolled.
Table 3 shows both the pathologies and etiologies of regurgitation in these patients. As expected, most patients had myxomatous MV degeneration (n = 105; 91.1%), resulting primarily in Carpentier classification type II leaflet prolapse (n = 103; 92.0%).15 Although prolapse was observed most often, approximately half of the patients had other reasons for valvular insufficiency, including chordal rupture (n = 65; 56.3%) and isolated annular dilatation (n = 6; 5.4%). Of the 112 patients, 101 (90.2%) had a valvuloplasty, and all 112 (100%) had a posterior band annuloplasty. As seen in Table 4, the most common valvuloplasty performed was a leaflet resection (n = 81; 72.3%). In addition, 15 (13.4%) patients had a chordal repair, prosthetic replacement, or transfer.
|
|
|
|
|
Of the 9 patients with more than grade 1 insufficiency at the follow-up TTE, 6 (5.3%) had either grade 2 or 3 regurgitation and required reoperations. Four of the 6 patients had a type II leaflet prolapse repaired with a leaflet resection and annuloplasty band. Three of these 4 had grade 1 regurgitation by TEE after repair, and the fourth had systolic anterior motion. All 4 patients had MV replacements with a mechanical valve. At reoperation, 1 had a dehiscence of the repair, but the other 3 repairs were intact but with new leakage. One of the 6 patients who required reoperation had a type II prolapse with a chordal rupture. The valve was repaired initially with a chordal replacement and annuloplasty band insertion. The postrepair TEE for this patient showed no regurgitation. However, a follow-up TTE showed a grade 2 leak at the posterior annulus. Four months after the first operation, the patient presented with a partial band dehiscence that caused hemolysis necessitating valve replacement. The remaining patient initially had grade 3 mitral regurgitation secondary to type 3 posterior leaflet restriction. The robotic repair consisted of a band annuloplasty, and the initial postrepair TEE showed only trace mitral regurgitation. However, the follow-up TTE showed grade 2 regurgitation with a central jet. Because the patient was symptomatic, the valve was replaced with a bioprosthesis.
There were no operative or midterm deaths; however, there were 11 major adverse events. The 6 that necessitated reoperations were discussed previously. Other complications included bleeding (re-exploration, n = 3), a pericardial effusion (drainage, n = 1), and a myocardial infarction (n = 1). There were no intraoperative conversions to alternative surgical techniques (eg, sternotomy or thoracotomy enlargement), and there were no da Vinci system-related adverse events. All procedures that were started with the da Vinci system were completed with robotic assistance.
Generalized estimating equations were used to analyze the learning curves associated with da Vinci system MV repairs. This model considers the correlation structure involved with repeated measures for a given surgeon/site participating in the trial. In patients requiring resections, CPB times decreased by 4.3 minutes per progressive case (Figure 1, A). In this same group, the mean aortic crossclamp time decreased by 3.7 minutes per case, and total operative times decreased by 4.4 minutes per case (Figure 1, B and C).
|
| Discussion |
|---|
|
|
|---|
Despite these and other successful minimally invasive valve operations, most surgeons have not embraced endoscopic methods for MV surgery. Onnasch and associates19 and Chitwood and Nifong18 independently showed that endoscopic MV surgery can be performed safely and with "gold standard" results, but in most instances their operations were video assisted rather than totally endoscopic.5 In contradistinction, Schroeyers and associates20 have shown that excellent MV repairs can be performed endoscopically by using 2-dimensional visualization and endoaortic occlusion. Few surgeons to date have adopted these methods because of the difficult transition from a wide-access, direct-vision cardiac operation to a completely endoscopic one that requires a combination of new technologies.
By limiting direct access to the valve, visualization becomes impaired, instrument manipulation is encumbered, and surgeon confidence in the safety and quality of the operation may wane. Surgical telemanipulation seems the ideal method for operating accurately through the small incisions and in restricted spaces. Robotic technology can provide many potential benefits to cardiac surgeons. Cutaneous incisions can be smaller because of improved optics and instrumentation. Moreover, wristlike articulations transfer the dexterous actions of instrument tips to the plane of the annulus and the papillary muscle level. With the addition of tremor filtration, there is improved precision in tight intracardiac spaces. Moreover, ambidexterity can become a reality for all surgeons. With these devices, leaflet resections, chordal transfers, and sliding plasties can be combined with a band or ring annuloplasty to perform complete repairs.12
The results reported herein represent an FDA-approved robotic MV surgery multicenter trial in which experienced MV repair surgeons from 10 centers enlisted patients into a standardized IRB- and FDA-approved protocol. In each patient, the major portion of each operation was performed robotically from a console removed from the operating table. The robotic system performed safely and efficiently, with no operative deaths or conversions due to a system malfunction. Moreover, there were no incision conversions either to a larger thoracotomy or to a median sternotomy.
These patients benefited from minimal musculoskeletal trauma, a low transfusion rate, and early discharge. Although there were no operative mortalities and few complications, 6 patients required reoperations, of which 5 had valve replacements and 1 had a second band annuloplasty. Although these patients had either no or less than grade 1 regurgitation on the postrepair TEE, they presented within 4 months with grade 3/4 regurgitation and symptoms. Repair failures were spread over 4 institutions, all of which had enrolled at least 10 patients in the study. Compared with the STS database, patients in the multicenter robotic trial had significantly lower mortality, fewer neurologic complications, and shorter lengths of hospital stay. Moreover, robotic MV patients tended to have fewer reoperations and overall complications than those in the STS cohort. Transfusion requirements were low (22.3%) and paralleled those of other minimally invasive valve operative series.21 Despite these benefits, crossclamp and perfusion times were significantly longer in the robot trial patients. The most significant complication, other than recurrent leakage, was a myocardial infarction in a patient secondary to right coronary artery air embolism.
In previous studies, residual regurgitation has been reported as an independent risk factor for reoperation.15 Lim and colleagues22 showed that approximately 59% of patients have clinically insignificant regurgitation after a repair. As seen in this series, most repair failures occur, are detected, and are addressed in the early postoperative period. Other authors have shown a mean regurgitant grade of 0.7 after a minimally invasive MV repair.21,23 In the 112 patients described herein, the mean grade of mitral regurgitation was 3.7 before surgery and 0.5 after surgery on the TTEs analyzed by the core laboratory.
Operative times were longer in this series compared with conventional sternotomy procedures. However, the learning curves demonstrate a progressive decline in crossclamp, CPB, and resection times, as well as overall operative times, in patients having repairs with or without leaflet resections. One can expect that operations performed early in the series would require longer times than those performed after both the surgeon and team have become familiar with the procedure. This same occurrence has been found in video-assisted MV repair series.24 As surgical teams become even more facile in using these devices, perioperative times can be expected to continue to decrease. Moreover, evolving adjunctive technology, such as annuloplasty band clips, may speed these operations even more.
Study limitations were primarily related to the investigation of an optimal study population with few comorbidities in the patients enrolled. FDA inclusion/exclusion criteria resulted in the exclusion of any patients with conditions such as coronary artery disease, mitral stenosis, bileaflet disease, significant aortic or tricuspid valve pathology, mitral annular calcification, morbid obesity, recent myocardial infarction or stroke, and poor ventricular function.
In summary, this multicenter study has shown that MV repairs can be performed safely in low-risk patients with potential patient benefits by multiple surgeons and teams. Despite the prearranged expertise of these surgeons, this series does suggest a higher early reoperative rate with the robotic methods than with other direct-vision, limited-access MV repairs. However, these data compare favorably to conventional repairs performed by multiple surgeons through a sternotomy. With the evolution of robotic surgical systems, surgeons and their patients can expect to gain the benefits shown in this study.
| Discussion |
|---|
|
|
|---|
In our own series, we have completed 26 of 28 successful MV repairs, including very complex repairs. We had to learn that the current technology still is suboptimal, and it was very hard to manage simple techniques such as the implantation of a complete remodeling ring and time-consuming knot tying.
During the past 3 years, we favored video-assisted surgery for routine use. However, we are working together with Intuitive on a concept for better teaching and training in endoscopic MV repair by using 2 consoles to apply computer simulation.
This article demonstrates very nicely that this type of MV surgery has been successfully introduced in the United States and has been further developed, especially by Dr Chitwoods group. I want to congratulate all the centers and authors for this tremendous work.
One has to understand that the results being presented reflect the situation of a completely new operation, and one has to accept that every surgeon has had to learn how to do it. There was no mortality, and there were no major intraoperative complications or neurologic deficits. The initial success rate of MV repair was very high: 99.1%.
I would like to ask 3 questions. You were mentioning that every team went through a special training for robotic MV surgery before clinical application. Can you elaborate on this and describe what was deemed to be necessary? Did all the centers have experience in minimally invasive video-assisted MV surgery?
Ten centers contributed to the study. Patient enrollment varied between 3 and 22 patients depicting different stages in the learning curves. Furthermore, you could demonstrate a clear improvement per given case concerning mean times of surgery, mean crossclamp times, and so on. How many patients should one operate on to feel comfortable?
The failure rate of successful MV repair was 9 (8%) of 112 within 1 month; 6 patients needed reoperation. Even if this reoperation rate compares favorably to the STS database rates, it seems high to me, because you were dealing with highly selected patients with uncomplicated MV disease. Do you think this may be due to the compromise of using a posterior band instead of a remodeling ring in such patients or inadequate compression by the suture technique?
Dr Nifong. Professor Mohr, thank you very much for your kind words and also legitimate criticisms. It is an honor to have our article reviewed by a pioneer in the field of robotic and minimally invasive cardiac surgery. Your team in Leipzig has contributed a great deal to this field.
To answer your first question regarding training for robotic mitral valve surgery, we have an intense 2-day program for training surgical teams. This occurs after teams have completed the "system" training, which is when they learn how to use the system and perform troubleshooting for potential problems. Valve training includes live case observation in the operating room followed by didactic discussion and review of the case. Issues related to peripheral cardiopulmonary bypass, aortic occlusion, cardioplegia administration, and deairing are reviewed and discussed.
We then spend a day and a half in the robotic laboratory using inanimate models, porcine hearts, and cadavers. We review each step of the procedure, including patient positioning, incisions, exposure, cannulation, retraction, and positioning of both the robotic surgical cart and instruments. All centers involved in the multicenter trial had experience in minimally invasive mitral valve surgery. However, at this time we are training teams with less minimally invasive or videoscopic experience, and they perform very well.
To answer your second question, we have performed 81 robotic mitral valve procedures and recently reviewed all the data with learning curves. In our experience, one should expect to complete approximately 15 cases before times begin to decrease.
To answer your third question, we are very sensitive to the issue regarding the 6 patients who required reoperation. One concerning issue is that none of those patients had more than grade 1 mitral regurgitation by postrepair transesophageal echocardiography, and these readings were by an off-site cardiologist blinded to the institution and procedure performed. At follow-up, these patients had advanced to grade 2 or worse mitral regurgitation.
As you are aware, it is quite difficult to manage a more rigid ring in the small space of the left atrium by using the robotic system; however, it can be done, and we have recently performed 2 valve replacements. We are currently working on ideas related to a new type of annuloplasty ring that may answer this problem and allow one to perform a full remodeling annuloplasty, if needed.
We do not believe that the suturing technique is a problem. The high magnification of vision systems allows the surgeon to see the compression and tightness of the knots. Air knots are easily seen and avoided.
Thank you again for reviewing our article.
| Footnotes |
|---|
Read at the Eighty-third Annual Meeting of The American Association for Thoracic Surgery, Boston, Mass, May 47, 2003.
1 (see Table 1 for a complete listing of participants and institutions ![]()
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
R. Umakanthan, M. Leacche, M. R. Petracek, S. Kumar, N. V. Solenkova, C. A. Kaiser, J. P. Greelish, J. M. Balaguer, R. M. Ahmad, S. K. Ball, et al. Safety of minimally invasive mitral valve surgery without aortic cross-clamp. Ann. Thorac. Surg., May 1, 2008; 85(5): 1544 - 1549. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. K. Rosengart, T. Feldman, M. A. Borger, T. A. Vassiliades Jr, A. M. Gillinov, K. J. Hoercher, A. Vahanian, R. O. Bonow, and W. O'Neill Percutaneous and Minimally Invasive Valve Procedures: A Scientific Statement From the American Heart Association Council on Cardiovascular Surgery and Anesthesia, Council on Clinical Cardiology, Functional Genomics and Translational Biology Interdisciplinary Working Group, and Quality of Care and Outcomes Research Interdisciplinary Working Group Circulation, April 1, 2008; 117(13): 1750 - 1767. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Rodriguez, L. W. Nifong, M. W.A. Chu, W. Wood, P. W. Vos, and W. R. Chitwood Robotic Mitral Valve Repair for Anterior Leaflet and Bileaflet Prolapse Ann. Thorac. Surg., February 1, 2008; 85(2): 438 - 444. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. E. Reiley, T. Akinbiyi, D. Burschka, D. C. Chang, A. M. Okamura, and D. D. Yuh Effects of visual force feedback on robot-assisted surgical task performance J. Thorac. Cardiovasc. Surg., January 1, 2008; 135(1): 196 - 202. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. R. Chitwood Jr. and E. Rodriguez Minimally Invasive and Robotic Mitral Valve Surgery Card. Surg. Adult, January 1, 2008; 3(2008): 1079 - 1100. [Full Text] |
||||
![]() |
M. J. Davidson and D. S. Baim Percutaneous Catheter-Based Mitral Valve Repair Card. Surg. Adult, January 1, 2008; 3(2008): 1101 - 1108. [Full Text] |
||||
![]() |
B. Kiaii, D. Bainbridge, and P. Fernandes Surgical, Anesthetic, Perfusion-Related Advances in Minimal Access Surgery Seminars in Cardiothoracic and Vascular Anesthesia, December 1, 2007; 11(4): 282 - 287. [Abstract] [PDF] |
||||
![]() |
J. M. Smith, H. Stein, A. M. Engel, S. McDonough, and L. Lonneman Totally Endoscopic Mitral Valve Repair Using a Robotic-Controlled Atrial Retractor Ann. Thorac. Surg., August 1, 2007; 84(2): 633 - 637. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Mihaljevic, E. H. Blackstone, and B. W. Lytle Folding Valvuloplasty Without Leaflet Resection: Simplified Method for Mitral Valve Repair Ann. Thorac. Surg., December 1, 2006; 82(6): e46 - e48. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Wimmer-Greinecker, O. Dzemali, T. Aybek, H. Keller, S. Mierdl, A. Moritz, and S. Dogan Perfusion strategies for totally endoscopic cardiac surgery MMCTS, October 9, 2006; 2006(1009): 1206. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. R. Chitwood Jr Our destination and our destiny: Real endoscopic cardiac surgery J. Thorac. Cardiovasc. Surg., October 1, 2006; 132(4): 753 - 754. [Full Text] [PDF] |
||||
![]() |
M. Argenziano, M. Katz, J. Bonatti, S. Srivastava, D. Murphy, R. Poirier, D. Loulmet, L. Siwek, U. Kreaden, D. Ligon, et al. Results of the prospective multicenter trial of robotically assisted totally endoscopic coronary artery bypass grafting. Ann. Thorac. Surg., May 1, 2006; 81(5): 1666 - 1675. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. A. D'Amico Robotics in thoracic surgery: Applications and outcomes J. Thorac. Cardiovasc. Surg., January 1, 2006; 131(1): 19 - 20. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |