JTCS Speed Up Your Browser
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Justus T. Strauch
Ulrich F.W. Franke
Martin Breuer
Jens Wippermann
Thorsten Wittwer
Thorsten Wahlers
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strauch, J. T.
Right arrow Articles by Wahlers, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strauch, J. T.
Right arrow Articles by Wahlers, T.
Related Collections
Right arrow Extracorporeal circulation
Right arrow Mechanical Circulatory Assistance
Right arrow Myocardial infarction

J Thorac Cardiovasc Surg 2005;130:1715-1716
© 2005 The American Association for Thoracic Surgery


Brief Communications

Technical feasibility of Impella Recover 100 microaxial left ventricular assist device placement after biologic aortic valve replacement (21 mm) for postcardiotomy failure

Justus T. Strauch, MD * , Ulrich F.W. Franke, MD, Martin Breuer, MD, Jens Wippermann, MD, Thorsten Wittwer, MD, Navid Madershahian, MD, Mirko Kaluza, Thorsten Wahlers, MD

Department of Cardiothoracic and Vascular Surgery, Friedrich-Schiller University, Jena, Germany

Received for publication June 24, 2005; accepted for publication August 1, 2005.

* Address for reprints: Justus T. Strauch, MD, Friedrich-Schiller University of Jena, Department of Cardiothoracic and Vascular Surgery, Erlanger Allee 101, D-07747 Jena, Germany (Email: justus.strauch{at}med.uni-jena.de).

The Impella Recover 100 (Impella CardioSystems AG, Aachen, Germany) is an intravascular microaxial blood pump intended to provide short-term mechanical support for acutely reduced left ventricular function in the setting of postcardiotomy heart failure refractory to high-dose inotropic support and intra-aortic balloon pump support. The low-cost device is fast to insert across the aortic valve through a 10-mm vascular graft sewn to the ascending aorta, avoiding the use of cardiopulmonary bypass, is simple to remove, and is associated with good properties for weaning. 1-3 Go However, the Impella has just recently been introduced into clinical practice, and no information is available about its use in patients who have previously undergone biologic aortic valve replacement, especially with small prosthesis sizes.

This report summarizes our initial clinical experience with such a patient. It should encourage the surgical community to take the device into consideration for borderline indications as a last resort.

Clinical Summary

A 69-year-old woman was admitted to our hospital after a diagnosis of coronary artery disease and severe aortic valve stenosis. The patient's history showed myocardial infarction of the anterior wall weeks previously, with multiple coronary artery interventions to the left anterior descending coronary artery, including stent implantation. In addition, aortic valve stenosis was diagnosed, with a peak-to-peak gradient of 61 mm Hg, an effective valve orifice area of 0.64 cm2, and left ventricular end-diastolic pressure of 30 mm Hg. Left ventricular ejection fraction was 25%, and EuroSCORE at the time of the operation was 12.

The patient underwent technically uneventful coronary artery revascularization with thoracic artery grafting to the left anterior descending coronary artery and aortic valve replacement with a 21 mm sized stented biological prosthesis. Weaning from cardiopulmonary bypass was accomplished with moderate catecholamine support. Shortly after coming off cardiopulmonary bypass, the patient had low cardiac output syndrome with an increase in left atrial pressure, decline of cardiac output, and an increased need for inotropic support. Subsequently, the patient underwent implantation of an intra-aortic balloon pump to control postcardiotomy failure. The patient's clinical condition deteriorated further, with a rise in inotropic support (epinephrine at 0.39 µg/[kg·min] and norepinephrine of 1.1 µg/[kg·min]). We therefore considered further left ventricular support; however, we hesitated to insert an Impella left ventricular assist device because with a 21-mm stented biologic valve it is said to be impractical to get through the biologic stented valve prosthesis. The pump body in its current existing form shows 7.3-mm diameter at the level of the outflow area located directly above the aortic valve area, and surgeons are commonly afraid of injuring the leaflet tissue of the valve.

After further impairment in the patient's condition, we decided to implant the Impella as final supportive therapy, after balancing all the pros and cons. After rethoracotomy, a 10-mm vascular graft was sewn to the ascending aorta (Figure 1). Without cardiopulmonary bypass, the device was inserted in a retrograde fashion across the stented aortic bioprosthesis from the ascending aorta into the cavity of the left ventricle. There were no technical difficulties regarding the previously described small orifice area of the 21-mm stented bioprosthesis for the device insertion. Under transesophageal echocardiographic guidance, only one attempt was necessary to get the device through the prosthesis (Figure 2). During the surgical procedure, transesophageal echocardiography played an essential role in the anatomic evaluation of the heart and correct intraventricular positioning of the device, 4 Go as did the careful observation of the pressure-differential curve on the device control. Device implantation resulted in a flow of 4.9 L/min, and the patient's condition stabilized throughout the next 24 hours, with a decline in catecholamine support. The patient died 4 days later with signs of multiorgan failure resistant to therapy, dominated by liver failure with a missing neogenesis of glucose and a loss of coagulation.


Figure 1
View larger version (100K):
[in this window]
[in a new window]
 
Figure 1. Impella Recover 100 device introduced in retrograde fashion into left ventricle through 10-mm prosthetic graft sewn to ascending aorta.

 

Figure 2
View larger version (74K):
[in this window]
[in a new window]
 
Figure 2. Intraoperative transesophageal echocardiographic guidance for correct intraventricular positioning of Impella Recover 100 across 21-mm stented aortic bioprosthesis.

 
Discussion

We encourage cardiac surgeons in the situation of critically ill patients in the setting of postcardiotomy heart failure, even after stented biologic aortic valve prosthesis implantation, to take the Impella Recover 100 device into consideration. We advise surgeons to embrace the use of this device as soon as possible for special borderline indications and not to waste any time in particularly life-threatening situations.

References

  1. Siegenthaler MP, Brehm K, Strecker T, Hanke T, Nötzold A, Olschewski M, et al. The Impella Recover microaxial left ventricular assist device reduces mortality for postcardiotomy failure: a three-center experience. J Thorac Cardiovasc Surg 2004;127:812-822.[Abstract/Free Full Text]
  2. Garatti A, Colombo T, Russo C, Lanfranconi M, Milazzo F, Catena E, et al. Different applications for the left ventricular mechanical support with the Impella Recover 100 microaxial blood pump. J Heart Lung Transplant 2004;24:481-485.
  3. Jurmann MJ, Siniawski H, Erb M, Drews T, Hetzer R. Initial experience with miniature axial flow ventricular assist devices for postcardiotomy heart failure. Ann Thorac Surg 2004;77:1642-1647.[Abstract/Free Full Text]
  4. Catena E, Milazzo F, Pittella G, Paino R, Colombo T, Garatti A, et al. Echocardiographic approach in a new left ventricular assist device: Impella Recover 100. J Am Soc Echocardiogr 2004;17:470-473.[Medline]



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Garatti, T. Colombo, and E. Vitali
Placement of the Impella Recover LD microaxial blood pump through a bioprosthesis is technically feasible
J. Thorac. Cardiovasc. Surg., October 1, 2006; 132(4): 989 - 990.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Justus T. Strauch
Ulrich F.W. Franke
Martin Breuer
Jens Wippermann
Thorsten Wittwer
Thorsten Wahlers
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strauch, J. T.
Right arrow Articles by Wahlers, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strauch, J. T.
Right arrow Articles by Wahlers, T.
Related Collections
Right arrow Extracorporeal circulation
Right arrow Mechanical Circulatory Assistance
Right arrow Myocardial infarction


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS