JTCS KCI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Daniel Roux
Stefano Saccani
Yves Glock
Gérard Fournial
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Léobon, B.
Right arrow Articles by Fournial, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Léobon, B.
Right arrow Articles by Fournial, G.
Related Collections
Right arrow Great vessels

J Thorac Cardiovasc Surg 2006;131:482-483
© 2006 The American Association for Thoracic Surgery


Brief Communication

Type A aortic dissection: New surgical strategy using intra-operative stenting

Bertrand Léobon, MD a , * , Daniel Roux, MD a , Stefano Saccani, MD b , Antoine Mugniot, MD a , Fabrice Muscari, MD a , Yves Glock, MD, PhD a , Gérard Fournial, MD a

a Service de Chirurgie Cardiovasculaire B. Centre Hospitalier Universitaire de Rangueil, Toulouse, France
b Divisione di Cardiochirurgia, Università degli Studi, Parma, Italy

Received for publication August 23, 2005; revisions received September 19, 2005; accepted for publication October 7, 2005.

* Address for reprints: Bertrand Léobon, MD, Service de Chirurgie Cardiovasculaire B. Centre Hospitalier Universitaire de Rangueil, 1 avenue Jean Poulhès, 31403, Toulouse Cedex 9, France (Email: leobon.b{at}chu-toulouse.fr).


Figure 1
D. Roux, Y. Glock, B. Léobon, G. Fournial (left to right)


Acute type A aortic dissection is a surgical emergency. After replacement of the ascending aorta, the arch and descending aorta often remain dissected, with a 40% risk of aneurysmal evolution at 5 years. Procedural dissections of arteries (coronary, renal, iliac) are treated with uncovered stents. Experimental studies on aortic dissections report suppression of false lumen and histologic cicatrization of stented aortas after 6 weeks. 1,2 Go On the basis of these facts, our strategy was to support aortic cicatrization and prevent aortic dilatation. During surgical replacement of the ascending aorta with circulatory arrest, we have implanted uncovered stents in the true lumen of the dissected arch or descending aorta as described for the first 5 patients. 3-5 Go Unlike stent grafts that cover entries, these stents were used to join the two dissected layers without compromising perfusion in the collateral arteries, especially in the aortic arch. The aim of our retrospective study was to assess feasibility and to analyze clinical and pathophysiologic results in the first 16 patients treated with this combined procedure.

Patients and Methods

From November 9, 2000, to September 1, 2004, 16 patients with acute type A aortic dissections have been treated with combined procedures. They underwent replacement of the ascending aorta and implantation of Djumbodis stents (Saint Côme Chirurgie, Marseille, France) (Figure 1). Stent implantations were achieved during complete circulatory arrest with deep hypothermia (12 patients) or partial circulatory arrest with antegrade cerebral perfusion (4 patients), according to the practices of the surgeons. Stent implantation took less than 2 minutes and was checked by direct vision (aortic arch) or radioscopy (descending aorta). Three patients were women (19%). Average age was 57.3 years (±10.6). Average EuroSCORE was 9.4 ± 2.9. Before the operation, the patients had important aortic regurgitation (n = 2), pericardial blood effusions (n = 4), myocardial infarctions (n = 2), stroke (n = 1), paraplegias (n = 2), and lower limb ischemia (n = 3). All patients had a dissection involving the whole aorta except for 1 patient without dissection of the descending aorta.


Figure 1
View larger version (66K):
[in this window]
[in a new window]
 
Figure 1. Left, Three sizes of Djumbodis stents (4, 9 and 14 cm). They can adapt from 20 to 50 mm in diameter as they are delivered on compliant Latex balloons. Right, Stent implantation in a cadaver aorta. Note permeability of the supra aortic trunks.

 
Results

Duration of circulatory arrest was 28.9 minutes (±10.8) at 14°C to 23°C for complete circulatory arrest and 25 minutes (±12.5) at 25°C for partial circulatory arrest. Fifteen stents were implanted in aortic arches and 3 stents in descending aortas. There were 2 intraoperative deaths (12.5%), 1 caused by unstoppable hemorrhage and 1 caused by myocardial infarction despite an aorta-coronary bypass. Intensive care unit stay was 9.2 days (±6). Postoperative complications were respiratory (9/16), renal failure (6/16), and stroke (1/16). Two patients died after discharge, on days 15 and 16, and no autopsy was obtained. One patient died 95 days after the operation of a cerebral hemorrhage without cardiac or carotid etiology. After stenting of the arch, all supra-aortic trunks were patent on baseline computed tomographic (CT) scans. Median follow-up was 329 days (±310). Thirty-day mortality was 25% (4/16). Cumulate survival (Kaplan-Meier) was 77.9%.

Both preoperative and postoperative most recent (159 ± 96 days) CT scans were available for 13 of the 16 patients (2 intraoperative deaths and 1 unavailable CT scan). The patient without dissection of the descending aorta was excluded from the following comparisons. In all 12 remaining cases, aortic arches received a stent, whereas none of these descending aortas was treated. Comparison between preoperative and postoperative CT scans showed that the circulating false lumen disappeared in 8 of the stented aortic arches (66.7%) (Figure 2) and only 5 in the nonstented descending aortas (41.7%) ({chi}2, P = .0384). The maximal diameters of the 12 stented aortic arches regressed –3.00 mm (±5.97) whereas the maximal diameters of the 12 nonstented descending aortas increased +1.17 mm (±3.71) (Student t test: P = .0070).


Figure 2
View larger version (72K):
[in this window]
[in a new window]
 
Figure 2. Left, Type A aortic dissection involving aortic arch before treatment. Right, After replacement of the ascending aorta and intra-operative stenting of the aortic arch, the false lumen has disappeared (Università degli Studi, Parma).

 
Comments

Despite the small number of patients, morbidity and mortality are in agreement with standard results in the literature and in our institutions for aortic dissection surgery. Technical feasibility is good, with correct durations of circulatory arrest and no major drawbacks concerning stent implantation taking less than 2 minutes.

Regarding pathophysiology, a favorable effect has been shown on false lumen occlusion and aortic diameter, with significant differences between stented and untreated segments in the same patients.

Mechanisms of action are different between uncovered stents and stent grafts. A stent graft occludes an entry and reduces flow and pressure in the false lumen, leading to its thrombosis. Here, the uncovered stent joins the dissected layers despite entries. It contributes to aortic reinforcement and cicatrization, as shown experimentally. 1,2 Go This cicatrization seems preferable to aortic replacement by a prosthesis or implantation of a stent graft because it preserves collateral arteries and may also restore perfusion in branches closed by dynamic occlusions.

Our conclusion is that this combined procedure is feasible and supports aortic restoration. We think such stenting should be extended to the whole dissected aorta.

Acknowledgments

We thank the Hospital of Rangueil (Toulouse, France), the Paul Sabatier University (Toulouse, France), la Università degli Studi (Parma, Italia), and the experimental surgery laboratory of Rangueil for their support.

References

  1. Trent MS, Parsonnet V, Shoenfeld R, Brener BJ, Eisenbud DE, Novick AS, et al. A balloon-expandable intravascular stent for obliterating experimental aortic dissection. J Vasc Surg. 1990;11:707-717.[Medline]
  2. Marty-Ane C, Serres-Cousine O, Laborde JC, Costes V, Alauzen M, Mary H. Use of endovascular stents for acute aortic dissection. an experimental study. Ann Vasc Surg 1994;8:434-442.[Medline]
  3. Roux D, Brouchet L, Concina P, Elghobary T, Glock Y, Fournial G. Type-A acute aortic dissection. combined operation plus stent management. Ann Thorac Surg 2002;73:1616-1618.[Abstract/Free Full Text]
  4. Saccani S, Nicolini F, Borrello B, Agostinelli A, Larini P, Marcato C, et al. New technologies for the treatment of type A aortic dissection. a case report. J Thorac Cardiovasc Surg 2004;127:1821-1823.[Free Full Text]
  5. Saccani S, Busi M, Fragnito C, Agostinelli A, Borrello B, Nicolini F, et al. Surgical repair and stent positioning for type A acute aortic dissection. a step forward?. Ann Thorac Surg 2005;79:1761-1763.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
R. S. Bonser, A. M. Ranasinghe, M. Loubani, J. D. Evans, N. M. A. Thalji, J. E. Bachet, T. P. Carrel, M. Czerny, R. Di Bartolomeo, M. Grabenwoger, et al.
Evidence, Lack of Evidence, Controversy, and Debate in the Provision and Performance of the Surgery of Acute Type A Aortic Dissection
J. Am. Coll. Cardiol., December 6, 2011; 58(24): 2455 - 2474.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. M. Elahi, M. Jafari Giv, M. Krishnaswamy, C. McLachlan, P. J. Mossop, and I. K. Nixon
Ascending aortic arch replacement with aortic valve resuspension under deep hypothermic arrest combined with endoluminal stenting of the descending thoracic aorta and the entire abdominal aorta
J. Thorac. Cardiovasc. Surg., October 1, 2009; 138(4): 1032 - 1035.
[Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
L. Niclauss and L. K. von Segesser
Total aortic arch stenting - hemodynamical impact of carotid artery perfusion
Interact CardioVasc Thorac Surg, October 1, 2009; 9(4): 562 - 564.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
E. Tireli and M. Ugurlucan
eComment: Fibrin glue reinforced Teflon felt sandwich for the prevention of anastomotic leak in replacement of ascending aorta for acute aortic dissection
Interact CardioVasc Thorac Surg, August 1, 2009; 9(2): 212 - 213.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Daniel Roux
Stefano Saccani
Yves Glock
Gérard Fournial
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Léobon, B.
Right arrow Articles by Fournial, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Léobon, B.
Right arrow Articles by Fournial, G.
Related Collections
Right arrow Great vessels


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS