JTCS Click here to go to SJM website.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Thomas G. Gleason
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gleason, T. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gleason, T. G.
Related Collections
Right arrow Coronary disease
Right arrow Valve disease

J Thorac Cardiovasc Surg 2006;131:502-503
© 2006 The American Association for Thoracic Surgery


Letter to the Editor

Aortic annuloplasty and valve-sparing root replacement: Details of the primary suture line

Thomas G. Gleason, MD

Northwestern University Feinberg School of Medicine, Galter 10-105, 201 East Huron St, Chicago, IL 60611-3056

To the Editor:

I greatly appreciate Dr David's poignant editorial comments 1 Go regarding graft sizing and tailoring during reimplantation of the aortic valve. There is no question that the anatomic components of the aortic valve amid a root aneurysm are abnormal. My primary hypothesis is that if we can restore proportional geometry to as close to normal as possible, we will be left with a more durable reimplanted valve—a concept that is also relevant to mitral valve repair. Dr David raised several concerns, notably the importance of (1) supporting the subcommissural triangles, (2) supporting the aortic annulus to prevent dilatation, and (3) restoring cusp coaptation height relative to the annular plane at the nadirs. With my technique, the subcusp suture line follows the coronet shape as it passes through the graft, but below the commissures there is a redundant triangular area of graft that juxtaposes the subcommissural triangle from one nadir to the next. With David's technique, the base of this triangle is where the primary suture line is placed. In my technique this area is similarly covered by overlying graft, but the affixing sutures sit higher and higher on the graft as the commissure is approached—this can often be 12 to 25 mm above the plane of the nadirs and above the edge of the graft directly below the commissure. The depth of dissection to achieve this graft position is the same for both techniques. The proximal end of the graft is necked down at the very base (positioned in the same plane as David's technique), but it is secured via non–pledget-supported subcusp mattress sutures that are passed through the annulus for greater structural support rather than through the fibrous subcommissural triangle—an area that is quite thin near the membranous septum. There is no need to have the subcommissural triangle actually sutured to the graft at the level of the nadirs because this fibrous triangle will quickly scar to the adjacent graft, affixing its diameter indefinitely after reimplantation. The area in question is a potential space that is easily dissected and is not normally supported by anything but the adjacent cardiac chambers. Therefore, the graft does circumferentially support both the subcommissural fibrous triangles and the annulus, and unlike the remodeling technique, a truly complete aortic annuloplasty is achieved. To date there has been no sign of any dilatation at the annular level or below.

I agree that cusp coaptation height is extremely important, and this is the reason why aortic annuloplasty is so important in a pathologic root. If the annulus and commissural resuspensions are not correctly reconstructed, there will be prolapse of one or more cusps below the optimal coaptation zone—5 to 6 mm above the annular plane, as Dr David explains. The impetus for developing my modifications was both to optimize the coaptation point (prevent prolapse) and to reduce the stress on the cusps by restoring a higher percentage of laminar flow through the valve during late systole (accommodate the cusps with optimally sized sinuses to prolong durability). Using M-mode echocardiography to evaluate leaflet opening and closing characteristics, 2 Go magnetic resonance–based magnitude masked flow images to evaluate anatomic detail, and magnetic resonance–based phase contrast flow images to evaluate flow dynamics, 3 Go we have been carefully studying all of the issues raised above to prove that these goals are being met. For example, Figure 1 shows still-frames from dynamic images extracted from phase contrast magnetic resonance studies all timed to peak opening at late systole. Note that in using this modified David technique, the reimplanted aortic valve of a Marfan patient has an effective orifice with flow dynamics that have been restored to normal in stark contrast to its preoperative state. More comprehensive quantitative and qualitative imaging studies are ongoing.


Figure 1
View larger version (57K):
[in this window]
[in a new window]
 
Figure 1. Dynamic magnetic resonance-based phase contrast flow images taken at a level 2 to 3 mm above the plane of the nadirs of the cusp hinge points (ie, the valvular portion of the root) frozen at peak opening (late systole) in a normal volunteer (A), preoperative Marfan patient (B), and postoperative Marfan patient (C). Note that white areas represent blood flowing perpendicular to the plane of the image out toward the viewer or laminar, antegrade flow.

 


    References
 Top
 References
 

  1. David TE. Sizing and tailoring the Dacron graft for reimplantation of the aortic valve. J Thorac Cardiovasc Surg. 2005;130:243-244.[Free Full Text]
  2. Aybek T, Sotiriou M, Wohleke T, Miskovic A, Simon A, Doss M, Dogan S, Wimmer-Greinecker G, Moritz A. Valve opening and closing dynamics after different aortic valve-sparing operations. J Heart Valve Dis 2005;14:114-120.[Medline]
  3. Kvitting JP, Ebbers T, Wigstrom L, Engvall J, Olin CL, Bolger AF. Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging. implications for aortic valve-sparing surgery. J Thorac Cardiovasc Surg 2004;127:1602-1607.[Abstract/Free Full Text]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Thomas G. Gleason
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gleason, T. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gleason, T. G.
Related Collections
Right arrow Coronary disease
Right arrow Valve disease


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS