|
|
||||||||
J Thorac Cardiovasc Surg 2006;131:1036-1044
© 2006 The American Association for Thoracic Surgery
Surgery for Acquired Cardiovascular Disease |
a Division of Cardiac Surgery, University of Ottawa, Ottawa, Ontario, Canada
b Department of Epidemiology, University of Ottawa, Ottawa, Ontario, Canada
c Division of Cardiology, University of Ottawa, Ottawa, Ontario, Canada
Received for publication August 1, 2005; revisions received October 13, 2005; accepted for publication October 20, 2005. * Address for reprints: Marc Ruel, MD, MPH, University of Ottawa Heart Institute, 40 Ruskin St, Suite 3403, Ottawa, Ontario, Canada K1Y 4W7 (Email: mruel{at}ottawaheart.ca).
| Abstract |
|---|
|
|
|---|
METHODS: Preoperative and serial postoperative echocardiograms were performed in 805 adults who underwent aortic valve replacement between 1990 and 2003 and who were subsequently followed up in a dedicated valve clinic (follow-up, mean ± SD, 5.5 ± 3.5 years; maximum, 14.2 years). Preoperative left ventricular function was defined as normal (ejection fraction
50%) in 548 patients and impaired (ejection fraction <50%) in 257 patients.
RESULTS: Patients with impaired preoperative left ventricular function and prosthesispatient mismatch (indexed effective orifice area
0.85 cm2/m2) had a decreased overall late survival (hazard ratio, 2.8; P = .03), decreased freedom from heart failure symptoms or heart failure death (odds ratio of 5.1 at 3 years after aortic valve replacement; P = .009), and diminished left ventricular mass regression compared with patients with impaired preoperative left ventricular function and no prosthesispatient mismatch. These effects of prosthesispatient mismatch were not observed in patients with normal preoperative left ventricular function.
CONCLUSIONS: Prosthesispatient mismatch at an indexed effective orifice area of 0.85 cm2/m2 or less after aortic valve replacement primarily affects patients with impaired preoperative left ventricular function and results in decreased survival, lower freedom from heart failure, and incomplete left ventricular mass regression. Patients with impaired left ventricular function represent a critical population in whom prosthesispatient mismatch should be avoided at the time of aortic valve replacement.
| Introduction |
|---|
|
|
|---|
|
Aortic
valve replacement (AVR) prolongs life, improves symptoms of heart failure, and induces regression of left ventricular hypertrophy in patients with aortic stenosis or aortic insufficiency for whom an operation is indicated. However, controversy exists as to whether the ability of the replacement prosthesis to allow unimpeded blood flow, a potentially modifiable parameter related to the size and type of prosthesis implanted at operation, influences the long-term outcome of patients undergoing AVR. The term prosthesispatient mismatch (PPM) has been used to describe the phenomenon in which the effective orifice area (EOA) of the implanted prosthesis may be inadequate for the patient's body size, potentially resulting in persistent left ventricular outflow tract obstruction. In general, PPM has been defined by a ratio of prosthetic EOA over patient body surface area (BSA), or indexed EOA, of 0.85 cm2/m2 or less
1
and has been observed in 19% to 70% of patients undergoing AVR.
2,3
Smaller mismatch thresholds of 0.80 cm2/m2 or less, 0.75 cm2/m2 or less, and 0.65 cm2/m2 or less have been proposed by some investigators.
2,3
The effect of PPM on survival and left ventricular remodeling after AVR has been controversial. Although some investigators have suggested that PPM results in decreased early and late survival after AVR,
3,4
others have failed to confirm these findings.
2,5-8
However, surgical selection factors confound this issue, because patients with PPM are usually older, are more often female, are more often overweight, and have a higher prevalence of comorbidities than those without PPM.
2,6
Two studies have examined the effect of PPM on freedom from heart failure after AVR, and both have suggested a detrimental effect of PPM.
2,9
There has been conflicting evidence on the effect of PPM on left ventricular hypertrophy regression. Some investigators have suggested that a small prosthesis does not impede left ventricular remodeling,
10-12
whereas others have observed decreased regression of left ventricular masses.
13-15
The relief of aortic obstruction constitutes the main mechanism of clinical improvement and left ventricular mass regression after AVR, and previous data have shown that preexisting left ventricular dysfunction impairs left ventricular mass regression after AVR.
16
It is therefore conceivable that PPM may affect clinical outcome and left ventricular mass regression in patients with abnormal left ventricular function differently than in those with normal left ventricular function. A recent article suggested that the early perioperative effect of PPM is especially significant in patients with preoperative left ventricular dysfunction.
3
To date, however, no study has examined the effect of preoperative left ventricular function on the medium- and long-term outcome of patients with PPM after AVR. Thus, the purpose of this study was to investigate whether the effect of PPM on medium- and long-term survival, freedom from heart failure, and left ventricular mass regression is affected by preoperative left ventricular function in patients undergoing AVR.
| Methods |
|---|
|
|
|---|
Patients received anticoagulation treatment according to guidelines in effect at the time, as previously described.
17
Persistence or recurrence of heart failure after AVR was defined as the composite end point of (1) New York Heart Association functional class III or IV symptoms for more than 4 consecutive weeks or (2) death for which the primary or contributing diagnosis was congestive heart failure.
2,3
Clinical impressions were corroborated with physical examination, chest radiograph, electrocardiogram, and echocardiographic findings. Persistent postoperative hypertension was defined as a systemic blood pressure greater than 140/90 mm Hg for 2 or more follow-up visits. Prosthesis-related complications were recorded according to the "Guidelines for Reporting Morbidity and Mortality after Cardiac Valvular Operations."
18
Prostheses
Prosthesis type and size were recorded for all patients. Prostheses were implanted and oriented according to the manufacturer's instructions. The prostheses used were the Medtronic Hancock II (Medtronic, Inc, Minneapolis, Minn) in 223 patients (28%), St Jude Medical Standard (St Jude Medical, Inc, St Paul, Minn) in 151 patients (19%), Carbomedics (Sulzer CarboMedics, Inc, Austin, Tex) in 137 patients (17%), Medtronic Hall in 89 patients (11%), homograft in 58 patients (7%), Medtronic Hancock I in 47 patients (6%), St Jude Medical HP in 45 patients (6%), Edwards PERIMOUNT (Edwards Lifesciences, Irvine, Calif) in 38 patients (5%), MCRI On-X (Medical Carbon Research Institute, Austin, Tex) in 8 patients (1%), stentless porcine in 5 patients (0.6%), and Carpentier-Edwards Standard in 4 patients (0.5%).
The in vivo EOA for each prosthesis type and size was obtained from the literature from patients with normally functioning prostheses
1
and averaged if more than 1 published value was available. This was supplemented with data provided by the valve manufacturer if published data were insufficient with respect to a specific prosthesis size.
The indexed EOA was obtained by dividing the in vivo EOA by the patient's BSA at the time of operation and was available for all patients. PPM was defined as an indexed EOA of 0.85 cm2/m2 or less for the purpose of examining clinical and echocardiographic outcomes. In addition, echocardiographic outcomes were examined at mismatch thresholds of 0.80 cm2/m2 or less and 0.75 cm2/m2 or less.
Echocardiography Follow-up
Patients underwent a complete M-mode, 2-dimensional, and Doppler transthoracic echocardiogram before AVR and underwent serial echocardiographic examinations on a biannual basis or as clinically indicated after AVR. Left ventricular end-diastolic and end-systolic diameters, septum and posterior wall thicknesses, and left atrial anteroposterior diameters were measured from the M-mode recordings according to the recommendations of the American Society of Echocardiography.
19
Left ventricular mass was calculated by using the modified formula of the American Society of Echocardiography.
20
Left ventricular ejection fraction (LVEF) was quantified by visual estimation by 1 or more of 4 blinded observers.
21
Left ventricular systolic function was graded as 1, normal (LVEF
50%); 2, mildly impaired (LVEF 40%-49%); 3, moderately impaired (LVEF 30%-39%); or 4, severely impaired (LVEF <30%). To assess the effect of preoperative left ventricular function on the effect of PPM, patients were divided into those with normal (LVEF
50%) and impaired (LVEF <50%) left ventricular systolic function. Peak instantaneous and mean transvalvular and transprosthesis pressure gradients were derived by modified Bernoulli equations, and the preoperative aortic valve EOA was calculated with the continuity equation.
22
Statistical Analyses
Data were imported and analyzed in Intercooled Stata 8 (Stata Corp, College Station, Tex). Continuous data are presented as mean ± SD or mean (lower 95% confidence limit, upper 95% confidence limit).
Survival
Potential predictors of survival, including left ventricular function and PPM indicators, were tested for equality with a log-rank test. For multivariate models, the proportional hazard assumption was tested with generalized Cox-Snell residuals. If the assumption was met, Cox proportional hazards models were developed (1) by incorporating variables that had a P value of .05 or less on log-rank testing; (2) by forcing into models the risk factors for decreased survival after AVR identified previously
2
(ie, age, atrial fibrillation, preoperative heart failure functional class, coronary artery disease, smoking, and insulin-dependent diabetes mellitus); and (3) by incorporating into the model patient characteristics that differed between the mismatch and no-mismatch groups. To account for confounding, no automated model selection procedure was used, and all covariates were used simultaneously. Proportional hazards models were subjected to 100 bootstrap replications, as previously described,
2
and estimates of standard error, bias, and 95% confidence intervals (CIs) were derived from the 100 replications by using a bias-corrected method.
Heart failure
The effects of left ventricular dysfunction and PPM on the cumulative incidence of heart failure symptoms or heart failurerelated death within 3 years after AVR were examined by logistic regression. A 3-year period was arbitrarily chosen to allow maximal symptom improvement and left ventricular remodeling in the greatest potential number of cohort patients
2,23
while minimizing the possible confounding effects of early structural valve deterioration on heart failure symptoms.
24
Logistic regression models incorporated (1) the risk factors for decreased freedom from heart failure after AVR identified previously
2
(ie, age, atrial fibrillation, coronary disease, and redo AVR status), and (2) patient characteristics that differed between the PPM and no-PPM groups.
Left ventricular mass regression
Echocardiographic left ventricular mass changes were derived from the lowest postoperative echocardiographically derived left ventricular mass minus the preoperative left ventricular mass. These changes were expressed in absolute fashion in relation to the preoperative left ventricular mass and indexed to the patient's baseline BSA. Changes were compared between PPM and no-PPM patients within the 2 subgroups of normal and impaired preoperative left ventricular function by using an analysis of variance. Bonferroni corrections for multiple tests were applied as appropriate. In addition, the independent effect of PPM on left ventricular mass regression within a left ventricular function subgroup was examined by using linear regression models that also incorporated age, sex, and postoperative hypertension as potential confounders of altered left ventricular mass regression.
25,26
| Results |
|---|
|
|
|---|
|
After surgery, patients with PPM had higher peak and mean instantaneous transprosthesis gradients compared with patients with no PPM (peak, 32.3 ± 16.3 mm Hg vs 27.3 ± 13.6 mm Hg; mean, 17.8 ± 9.5 mm Hg vs 14.7 ± 7.6 mm Hg, respectively; P < .001). There was no significant difference in postoperative peak and mean instantaneous transprosthesis gradients between patients with normal and impaired preoperative left ventricular function (peak, 29.8 ± 15.1 mm Hg vs 27.8 ± 14.4 mm Hg; mean, 16.1 ± 8.4 mm Hg vs 15.4 ± 8.8 mm Hg, respectively; P > .1).
Survival
Figure 1
displays the crude and adjusted survival of the total cohort according to the preoperative left ventricular function and the presence of PPM after AVR. Patients with the combination of impaired preoperative left ventricular function and postoperative PPM had decreased survival after AVR, both crude (Figure 1, A) and after adjustment for age, sex, atrial fibrillation, preoperative heart failure functional class, coronary artery disease, smoking, insulin-dependent diabetes mellitus, predominant valve lesion at operation, and use of a bioprosthesis (Figure 1, B). An independent death hazard ratio of 2.6 (bias-corrected 95% CI, 1.1-7.8; P = .02) was observed in patients with impaired left ventricular function and PPM compared with patients with normal left ventricular function and no PPM. Furthermore, a death hazard ratio of 2.8 (95% CI, 1.1-8.0; P = .03) was observed in patients with impaired left ventricular function and PPM compared with patients with impaired left ventricular function and no PPM. In contrast, there was no difference in crude or adjusted survival between patients with normal preoperative left ventricular function and PPM versus patients with normal preoperative left ventricular function and no PPM (hazard ratio, 1.6; 95% CI, 0.7-3.8; P = .3).
|
|
|
| Discussion |
|---|
|
|
|---|
Conversely, our data also demonstrate that PPM at a threshold of 0.85 cm2/m2 or less does not result in significant detrimental effects on overall long-term survival, freedom from heart failure, and left ventricular mass regression in patients with normal preoperative left ventricular function. Thus, special techniques other than optimized prosthesis selection based on hemodynamics that are used to avoid mismatch and that may occasionally be associated with additional operative risk, such as the use of aortic root enlargement or the implantation of a stentless valve, do not seem justified solely on the basis of potential improvement in late outcome in patients with normal left ventricular function and a predicted indexed EOA of less than 0.85 cm2/m2 at the time of AVR. However, because this study examined only common mismatch thresholds and did not evaluate very severe mismatch, such as 0.65 cm2/m2 or less (a value occasionally chosen by other investigators),
3
we cannot comment on whether more severe PPM might in turn lead to a significant late clinical or echocardiographic effect in patients with normal left ventricular function.
Recently, Blais and colleagues
3
suggested that the early perioperative clinical effect of PPM may be most significant in patients with preoperative left ventricular dysfunction. These investigators observed a 3.7-fold increase in the 30-day mortality rate in patients with PPM and a left ventricular ejection fraction of less than 40% compared with patients with PPM and an ejection fraction greater than 40%. Patients with PPM and a preoperative left ventricular ejection fraction less than 40% had a 77.1 relative risk ratio for mortality at 30 days compared with an 11.3 relative risk ratio for patients with PPM and a left ventricular ejection fraction of 40% or more. To our knowledge, no study to date has evaluated the medium- and long-term effect of PPM after AVR on the basis of the preoperative left ventricular function and separately analyzed patients with normal versus impaired left ventricular function. Our data expand on the observations of Blais and colleagues and demonstrate that PPM at a threshold of 0.85 cm2/m2 or less decreases long-term survival and freedom from heart failure and impairs left ventricular mass regression beyond the perioperative period in patients with impaired preoperative left ventricular function, but not in patients with normal preoperative left ventricular function. It is possible that the interaction between PPM and preoperative left ventricular function identified in this study may have accounted in part for the often-conflicting observations on the effect of PPM in previous studies.
This study examined the outcome of patients who survived AVR and did not focus on early perioperative outcomes, in order to evaluate left ventricular mass regression and heart failure symptoms, which cannot be adequately evaluated in the perioperative period. Furthermore, surgical decision making and confounding by indication may especially bias perioperative outcomes in patients with PPM, because surgeons may tend to avoid the more complex operation required to implant a larger prosthesis and avoid mismatch in patients with poor physical condition and significant comorbidity who are at higher baseline operative risk, thus resulting in an apparent increase in perioperative mortality in patients receiving a smaller prosthesis. This potential perioperative bias may therefore have been minimized by our study design.
Limitations
Our study used the indexed in vivo EOA values derived from normally functioning valves rather than prosthesis size to determine the presence of PPM after AVR.
1
The use of other indices, such as prosthesis label size, which is not standardized, or geometric internal orifice area, which does not account for the many characteristics of a valve that may contribute significantly to the EOA (such as prosthesis height, profile, opening angle, and leaflet inertia), may have played a role in the discrepancies between studies that have examined the effect of PPM. Using the EOA derived by the Doppler-echo continuity equation in individual patients after prosthesis implantation might have better quantified the degree of PPM; however, this method also has several limitations related to difficulties of accurately measuring the left ventricular outflow diameter caused by reverberations from the prosthetic valve and the presence of large localized transprosthetic gradients and nonflat transprosthetic spatial velocity profiles, which frequently result in large discrepancies between Doppler-echo and actual EOA measurements.
28-30
Furthermore, the EOA derived from individual patients has a major drawback because it is not available at the time of surgical decision making and therefore cannot help to avoid PPM during the operation. This EOA can be determined only once the prosthesis has been inserted, the patient has been weaned from cardiopulmonary bypass, and the preload, afterload, and contractility have normalized. Therefore, the EOA of an individual patient has little or no role in predicting whether PPM will be avoided by using a given prosthesis and size and whether another prosthesis or size should be selected and/or aortic root enlargement be performed before implantation. It is important to note that PPM, as defined in this study by using the in vivo EOA, was strongly predictive of early and late postoperative transprosthesis gradients, thus suggesting that our methodology accurately reflected aortic root hemodynamics in individual patients.
Previous myocardial infarction is difficult to rule out with certainty in patients with severe valvular disease, coronary artery disease, and left ventricular dysfunction. Consequently, it was not always possible to establish the exact underlying etiology of left ventricular dysfunction in affected patients of this cohort, even though the coprevalence of coronary artery disease at baseline was adjusted for in the multivariate analyses. It is possible that the underlying mechanism of left ventricular dysfunction in affected patients may have varied between the mismatch and no-mismatch groups in a proportion that was different from that of their respective coprevalence of coronary disease, and, if so, this could have confounded the results. Furthermore, the findings of this study, as with any large observational cohort, may not necessarily be generalizable to all patients with prosthetic valves, because it represents a single institution's experience and may have been affected by referral and patient care patterns.
| Conclusions |
|---|
|
|
|---|
| See related editorial on page 952.
|
| References |
|---|
|
|
|---|
Related Article
This article has been cited by other articles:
![]() |
W.R. E. Jamieson, J. Ye, J. Higgins, A. Cheung, G. J. Fradet, P. Skarsgard, E. Germann, F. Chan, and S. V. Lichtenstein Effect of Prosthesis-Patient Mismatch on Long-Term Survival With Aortic Valve Replacement: Assessment to 15 Years Ann. Thorac. Surg., January 1, 2010; 89(1): 51 - 59. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Nozohoor, J. Nilsson, C. Luhrs, A. Roijer, and J. Sjogren Influence of prosthesis-patient mismatch on left ventricular remodelling in severe aortic insufficiency Eur. J. Cardiothorac. Surg., January 1, 2010; 37(1): 133 - 138. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Alvarez, J. S. Quiroga, M. V. Fernandez, B. A. Nazar, F. G. Sampedro, J. M. Martinez Comendador, J. M. Martinez Cereijo, and M. T. Alves Perez Up to twenty-five-year survival after aortic valve replacement with size 19 mm valves Interactive CardioVascular and Thoracic Surgery, January 1, 2010; 10(1): 32 - 35. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Jilaihawi, D. Chin, T. Spyt, M. Jeilan, M. Vasa-Nicotera, J. Bence, E. Logtens, and J. Kovac Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis Eur. Heart J., December 25, 2009; (2009) ehp537v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Suri, K. J. Zehr, T. M. Sundt III, J. A. Dearani, R. C. Daly, J. K. Oh, and H. V. Schaff Left ventricular mass regression after porcine versus bovine aortic valve replacement: a randomized comparison. Ann. Thorac. Surg., October 1, 2009; 88(4): 1232 - 1237. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. A. Mannacio, V. De Amicis, L. Di Tommaso, F. Iorio, and C. Vosa Influence of prosthesis-patient mismatch on exercise-induced arrhythmias: A further aspect after aortic valve replacement J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 632 - 638. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Price, H. Lapierre, L. Ressler, B.-K. Lam, T. G. Mesana, and M. Ruel Prosthesis-patient mismatch is less frequent and more clinically indolent in patients operated for aortic insufficiency J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 639 - 645. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Cattaneo, M. Baravelli, A. Rossi, G. Mariscalco, M. Romano, D. Imperiale, A. Bregasi, and C. Anza Ejection Fraction/Velocity Ratio Identifies Prosthesis-Patient Mismatches in Patients With Aortic Bioprosthetic Valves and Left Ventricular Dysfunction J. Ultrasound Med., September 1, 2009; 28(9): 1167 - 1174. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Urso, R. Sadaba, and G. Aldamiz-Echevarria Is patient-prosthesis mismatch an independent risk factor for early and mid-term overall mortality in adult patients undergoing aortic valve replacement? Interactive CardioVascular and Thoracic Surgery, September 1, 2009; 9(3): 510 - 518. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kulik, N. T. Kouchoukos, and M. Ruel Avoiding prosthesis-patient mismatch in the elderly: options other than mechanical prostheses. Ann. Thorac. Surg., September 1, 2009; 88(3): 1049 - 1050. [Full Text] [PDF] |
||||
![]() |
J.-L. Monin Prosthesis-patient mismatch: myth or reality? Heart, June 1, 2009; 95(11): 948 - 952. [Full Text] [PDF] |
||||
![]() |
W.R. E. Jamieson, E. Germann, J. Ye, F. Chan, A. Cheung, J. S. MacNab, G. J. Fradet, E. A. Stanford, L. A. Bryson, and S. V. Lichtenstein Effect of Prosthesis-Patient Mismatch on Long-Term Survival With Mitral Valve Replacement: Assessment to 15 Years Ann. Thorac. Surg., April 1, 2009; 87(4): 1135 - 1142. [Abstract] [Full Text] [PDF] |
||||
![]() |
J G Dumesnil, J Magne, N Girerd, and P Pibarot Moderate patient-prosthesis mismatch can impact on mortality after aortic valve replacement Heart, April 1, 2009; 95(7): 592 - 592. [Full Text] [PDF] |
||||
![]() |
J Mascherbauer and H Baumgartner The authors' reply: Heart, April 1, 2009; 95(7): 592 - 593. [Full Text] [PDF] |
||||
![]() |
P. Pibarot and J. G. Dumesnil Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management Circulation, February 24, 2009; 119(7): 1034 - 1048. [Full Text] [PDF] |
||||
![]() |
M. R. Moon, J. S. Lawton, N. Moazami, N. A. Munfakh, M. K. Pasque, and R. J. Damiano Jr. POINT: Prosthesis-patient mismatch does not affect survival for patients greater than 70 years of age undergoing bioprosthetic aortic valve replacement. J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 278 - 283. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Mohty, J. G. Dumesnil, N. Echahidi, P. Mathieu, F. Dagenais, P. Voisine, and P. Pibarot Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction. J. Am. Coll. Cardiol., January 6, 2009; 53(1): 39 - 47. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Mascherbauer, R Rosenhek, C Fuchs, E Pernicka, U Klaar, C Scholten, M Heger, G Wollenek, G Maurer, and H Baumgartner Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality Heart, December 1, 2008; 94(12): 1639 - 1645. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-A. Clavel, C. Fuchs, I. G. Burwash, G. Mundigler, J. G. Dumesnil, H. Baumgartner, J. Bergler-Klein, R. S. Beanlands, P. Mathieu, J. Magne, et al. Predictors of Outcomes in Low-Flow, Low-Gradient Aortic Stenosis: Results of the Multicenter TOPAS Study Circulation, September 30, 2008; 118(14_suppl_1): S234 - S242. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Masuda, H. Kado, Y. Ando, A. Shiose, T. Nakano, K. Fukae, Y. Tanoue, and R. Tominaga Intermediate-term results after the aortic valve replacement using bileaflet mechanical prosthetic valve in children. Eur. J. Cardiothorac. Surg., July 1, 2008; 34(1): 42 - 47. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kohsaka, S. Mohan, S. Virani, V.-V. Lee, A. Contreras, G. J. Reul, and S. A. Coulter Prosthesis-patient mismatch affects long-term survival after mechanical valve replacement. J. Thorac. Cardiovasc. Surg., May 1, 2008; 135(5): 1076 - 1080. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Bleiziffer, W B Eichinger, I Hettich, D Ruzicka, M Wottke, R Bauernschmitt, and R Lange Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement Heart, May 1, 2008; 94(5): 637 - 641. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Nozohoor, J. Nilsson, C. Luhrs, A. Roijer, and J. Sjogren Influence of Prosthesis-Patient Mismatch on Diastolic Heart Failure After Aortic Valve Replacement Ann. Thorac. Surg., April 1, 2008; 85(4): 1310 - 1317. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kulik, M. Al-Saigh, V. Chan, R. G. Masters, P. Bedard, B.-K. Lam, F. D. Rubens, P. J. Hendry, T. G. Mesana, and M. Ruel Enlargement of the Small Aortic Root During Aortic Valve Replacement: Is There a Benefit? Ann. Thorac. Surg., January 1, 2008; 85(1): 94 - 100. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. D. Desai and G. T. Christakis Bioprosthetic Aortic Valve Replacement: Stented Pericardial and Porcine Valves Card. Surg. Adult, January 1, 2008; 3(2008): 857 - 894. [Full Text] |
||||
![]() |
J.-L. Monin, M. Monchi, M. E.W. Kirsch, H. Petit-Eisenmann, S. Baleynaud, C. Chauvel, D. Metz, C. Adams, J.-P. Quere, P. Gueret, et al. Low-gradient aortic stenosis: impact of prosthesis-patient mismatch on survival Eur. Heart J., November 1, 2007; 28(21): 2620 - 2626. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. D. Peterson, M. A. Borger, C. M. Feindel, and T. E. David Aortic Annular Enlargement During Aortic Valve Replacement: Improving Results With Time Ann. Thorac. Surg., June 1, 2007; 83(6): 2044 - 2049. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Pibarot and J. G. Dumesnil Prosthesis-patient mismatch in the mitral position: Old concept, new evidences J. Thorac. Cardiovasc. Surg., June 1, 2007; 133(6): 1405 - 1408. [Full Text] [PDF] |
||||
![]() |
P. Pibarot and J. G Dumesnil Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible? Heart, May 1, 2007; 93(5): 549 - 551. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Bleiziffer, W. B Eichinger, I. Hettich, R. Guenzinger, D. Ruzicka, R. Bauernschmitt, and R. Lange Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? Heart, May 1, 2007; 93(5): 615 - 620. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. R. Bridges, S. M. O'Brien, J. C. Cleveland, E. B. Savage, J. S. Gammie, F. H. Edwards, E. D. Peterson, and F. L. Grover Association between indices of prosthesis internal orifice size and operative mortality after isolated aortic valve replacement J. Thorac. Cardiovasc. Surg., April 1, 2007; 133(4): 1012 - 1021. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kulik, I. G. Burwash, V. Kapila, T. G. Mesana, and M. Ruel Long-Term Outcomes After Valve Replacement for Low-Gradient Aortic Stenosis: Impact of Prosthesis-Patient Mismatch Circulation, July 4, 2006; 114(1_suppl): I-553 - I-558. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |