JTCS Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jean G. Dumesnil
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dumesnil, J. G.
Right arrow Articles by Pibarot, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dumesnil, J. G.
Right arrow Articles by Pibarot, P.
Related Collections
Right arrow Cardiac - physiology
Right arrow Congestive Heart Failure
Right arrow Valve disease
Right arrowRelated Article

J Thorac Cardiovasc Surg 2006;131:952-955
© 2006 The American Association for Thoracic Surgery


Editorial

Prosthesis–patient mismatch and clinical outcomes: The evidence continues to accumulate

Jean G. Dumesnil, MD, FRCP (C), FACC * , Philippe Pibarot, DVM, PhD, FACC

Québec Heart Institute, Laval Hospital, Sainte-Foy, Quebec, Canada.

Received for publication November 21, 2005; revisions received December 13, 2005; accepted for publication December 16, 2005.

* Address for reprints: Jean G. Dumesnil, Québec Heart Institute, Laval Hospital, 2725 Chemin Sainte-Foy, Sainte-Foy, Quebec, Canada G1V-4G5. (Email: medjgd{at}hemes.ulaval.ca).

GoIn this issue of the Journal, Ruel and associates 1 Go report that aortic valve prosthesis–patient mismatch (PPM) predominantly affects patients with left ventricular (LV) dysfunction. As they point out, PPM remains a controversial issue. On the one hand, there is indeed an increasing body of evidence suggesting that PPM occurs frequently and has important clinical consequences. 2-13 Go To the opposite, some authors have argued that PPM is a rare phenomenon without relevant clinical implications. 14-19 Go The article from Ruel and colleagues 1 Go brings new evidence from two standpoints: (1) It further documents the impact of PPM on long-term clinical outcomes such as survival, freedom from heart failure, and LV mass regression, whereas there has been a paucity of data in this regard and most studies have been limited to the short or medium term; (2) it adds a new dimension to this type of study in that it examines whether PPM and preoperative LV function interact with regard to their impact on these outcomes.

Definition of PPM

Given the controversy that has surrounded PPM and to put the findings of Ruel and coworkers into proper perspective, it is important to review certain essential elements regarding this concept and its identification. Indeed, the term PPM was first coined in 1978 by Rahimtoola, 20 Go who defined it as follows: "Mismatch can be considered to be present when the effective prosthetic valve area, after insertion into the patient, is less than that of a normal human valve." In his original publication, the author insisted that the main consequence of PPM would be to produce higher postoperative gradients resulting in an increased hemodynamic burden for the ventricle, and he actually provided a graph summarizing his vision of the relation between the effective orifice area (EOA) of the prosthesis and postoperative gradients. However, the graph showed no normalization for body size and, as it stood, it could be interpreted as the conceptual relation that would exist between EOA and gradients in a person with average body size. Importantly, it must be emphasized that higher postoperative gradients and increased LV workload are inherent to the concept of PPM. Hence, an alternate definition for PPM could well be: "PPM occurs when the EOA of the prosthesis is too small in relation to the patient's body size, resulting in abnormally high postoperative gradients."

Parameter Used to Define PPM

The parameter first proposed to identify PPM has been the indexed EOA, which is the EOA of the prosthesis divided by the patient's body surface area. 21,22 Go It should be emphasized that the EOA is a physiologic parameter derived from hydraulic principles and it corresponds to the area occupied by flow as it exits the valve. Clinically, it is calculated from either the continuity equation when using echocardiography or the Gorlin formula during cardiac catheterization. Unfortunately, it cannot be predicted from the size of the prosthesis or its geometric area because the criteria used to calculate the geometric area vary from one type of prosthesis to the other; in addition, the ratio between the EOA and the geometric area also varies widely from one type and/or size of prosthesis to another. 8,14,23 Go The rationale behind the normalization of the EOA for body surface area is to account for cardiac output requirements since transvalvular pressure gradients are essentially determined by the EOA and transvalvular flow, which in turn are largely determined by body size.

Reference values for EOA data exist for each type and size of prosthesis, 5,8 Go and they should ideally be derived from in vivo rather than in vitro values since the latter are often more optimistic than the former and are not representative of the real-life situation. To this effect, it should be emphasized that, as was done in this study, the indexed EOA calculated from such reference values or from postoperative echocardiograms remains the only parameter that has been successfully validated to predict postoperative outcomes, 2-13 Go as well as to prospectively prevent PPM 24 Go and avoid high postoperative gradients.

However, as is the case for many physiologic parameters, the EOA has some inherent variability that is mainly related to the techniques used for its measurement, as well as to a certain flow dependency. For this reason, some authors have alternatively attempted to characterize PPM in terms of the indexed internal geometric area (IGA) rather than the indexed EOA. 14-16 Go In contrast to the EOA, the IGA is an anatomic parameter calculated from the static measurement of the internal diameter of the prosthesis. In this sense, it is very reproducible and exhibits little variability. However, it has consistently been shown to be unrelated to either postoperative gradients 25 Go or clinical outcomes. 14-19 Go This point is well illustrated by the recent data of Koch and associates, 19 Go whereby these authors reported identical values for indexed IGA in patients with pericardial valves and patients with allografts whereas peak and mean gradients were twice as high in the former as in the latter. Not surprisingly, the same article found no relation between the indexed IGA and the clinical outcome of functional recovery after surgery. As appropriately pointed out by the authors, one of the likely explanations for the discrepancy between their results and other studies showing a relation between PPM and clinical outcomes is the difference in choice of parameters to identify PPM.

Hence, it becomes evident from a practical standpoint that, notwithstanding its limitations, the indexed EOA is the only parameter with proven validity to characterize PPM, prevent its occurrence, and predict postoperative outcomes. For this reason and to avoid further confusion, we would thus propose that the term PPM be used only with regard to data collected by use of the indexed EOA, whereas data collected by use of the indexed IGA should be more appropriately termed prosthesis–patient size. These considerations also further emphasize that it is not the size or the geometric dimensions of a prosthesis that are clinically relevant, but rather the match between its anticipated hemodynamic performance and the size of the patient. When the right parameter is used for its identification, PPM is also found be to a relatively frequent phenomenon 5,8,12 Go akin to the 40% prevalence (325/805 patients) observed in the present study.

Interaction Between PPM and LV Function

To analyze how the relation between PPM and clinical outcomes might be affected by LV function is conceptually attractive since an increased hemodynamic burden should theoretically be less well tolerated by a poorly functioning ventricle than by a normal ventricle. 26,27 Go In this sense, the present results are extremely valuable in that they indirectly corroborate the data of Blais and colleagues, 8 Go showing a strong interaction between PPM and depressed LV function with regard to early mortality after AVR, and are the first to show that such an interaction also exists in relation to late mortality, heart failure, and LV mass regression.

An important limitation of the study, however, is that characterization of LV function was based only on a visual estimate of the ejection fraction by one or more of four blinded observers. Given that LV function is a major and pivotal variable of the study, it is indeed unfortunate that the authors did not provide some measure of intraobserver or interobserver variability and/or did not corroborate their results by the use of a more objective method of quantifying the ejection fraction. In this context, it becomes difficult to ascertain what might have been the margin of error and how many patients might have been misclassified. This limitation also has to be taken into consideration when analyzing the clinical implications of the study.

Threshold Values for Identification and Classification of PPM

The threshold values of indexed EOA used to identify and classify PPM have also been a matter of discussion. 10 Go In the present study, the authors have elected to dichotomize their patients between those having an indexed EOA below or above 0.85 cm2/m2, whereas other studies have used threshold values ranging from 0.75 to 0.90 cm2/m2 to dichotomize patients. An alternate approach has also been to consider PPM as a continuum rather than a dichotomy and, as is routinely done for native aortic valve disease, to classify patients according to the degree of severity. 7,8,9,12 Go Indeed, when the latter approach is used, a strong relation can be found between the degree of severity of PPM and the prevalence of negative outcomes. For unknown reasons, the present study tested different thresholds of severity only in the case of LV mass and did indeed find significant differences. In the study of Blais and colleagues, 8 Go the impact of PPM was found to increase exponentially in relation to the degree of severity to the extent that even patients with normal LV function were found to have a significant increase in early mortality when faced with severe PPM. Hence, one cannot exclude that a similar result might not have been observed in the present study had a similar type of analysis been performed. The appropriateness of classifying PPM according to the degree of severity is also corroborated by other studies 7,9,12 Go and is logical in the sense that, as for native aortic valve disease, the impact of PPM should be viewed in relative terms, that is, in terms of the degree of imbalance between LV afterload and the status of LV function. 27 Go

Clinical Implications

The clinical implications of this study are important in that they clearly demonstrate that PPM has a significant impact on important clinical outcomes such as late survival, freedom from heart failure, and LV mass regression and that this impact is highly modulated by the functional status of the LV before surgery. The temptation to conclude from these findings that PPM is an important consideration only in patients with reduced LV function and can almost be dismissed as irrelevant in patients with normal LV function should, however, be avoided. Indeed, because PPM was analyzed as a dichotomy rather than a continuum, it cannot be excluded that severe PPM also had an impact in patients with normal LV function. Moreover, on examination of Figures 1 and 2 from Ruel's study, 1 Go it is striking to see that patients with PPM and normal LV function tended to have poorer outcomes than those with no PPM and normal LV function, as well as those with no PPM and impaired LV function. Hence, the impact of PPM on clinical outcomes might well be at least as important as that of LV function. The fact that this did not come out in multivariate analysis might be due to the influence of other confounding variables. The issue is also further confounded by the potential variability in the estimate of the ejection fraction and the fact that patients with borderline values might have been misclassified. From a practical standpoint, to consider PPM irrelevant in a patient with normal LV function could be hazardous given that the eventual occurrence of severe PPM or misclassification of LV function cannot be excluded in the individual patient.

In this context, it should be emphasized that the projected indexed EOA of the prosthesis to be inserted can be calculated before surgery and that, in the case of an anticipated PPM, alternate procedures such as aortic root enlargement 24 Go or insertion of a better performing valve substitute (eg, supra-annular bioprostheses, 28 Go stentless valves, 29 Go newer generation mechanical valves, 30,31 Go homografts, or the Ross operation 32 Go) can be envisioned. 5,8 Go Castro and coworkers 24 Go have indeed demonstrated that such a strategy can be used successfully to prevent PPM, and most manufacturers now provide user-friendly charts allowing easy calculation of the projected indexed EOA within the operating room. In any given case, this information can easily be incorporated within the clinical decision-making process and used in view of the other pertinent clinical factors such as age, level of physical activity, status of LV function, and concomitant procedures. For instance, if one projects moderate PPM in an elderly patient with reduced physical activity and normal LV function, it might be estimated that the benefits of doing an alternate procedure to avoid PPM are outweighed by the inherent risks or disadvantages of doing such a procedure. On the other hand, the reverse could be true if severe PPM was projected in the same patient and/or if there was evidence of impaired LV function. In this context, the present results are further confirmation that the projected indexed EOA should routinely be calculated before aortic valve replacement and become an integral part of the clinical decision-making process. Finally, the observation that PPM has a significant impact on LV mass regression only in patients with impaired LV function is new and intriguing. It will require further validation and documentation with regard to physiopathology and potential clinical implications.


See related article on page 1036.

 

References

  1. Ruel M, Al-Faleh H, Kulik A, Chan KL, Mesana TG, Burwash IG. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with pre-existing left ventricular dysfunction. impact on survival, freedom from heart failure, and left ventricular mass regression. J Thorac Cardiovasc Surg 2006;131xxx–x.
  2. Pibarot P, Honos GN, Durand LG, Dumesnil JG. The effect of patient-prosthesis mismatch on aortic bioprosthetic valve hemodynamic performance and patient clinical status. Can J Cardiol 1996;12:379-387.[Medline]
  3. Pibarot P, Dumesnil JG, Lemieux M, Cartier P, Métras J, Durand LG. Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity, and mortality after aortic valve replacement with a bioprosthetic heart valve. J Heart Valve Dis 1998;7:211-218.[Medline]
  4. Del Rizzo DF, Abdoh A, Cartier P, Doty DB, Westaby S. Factors affecting left ventricular mass regression after aortic valve replacement with stentless valves. Semin Thorac Cardiovasc Surg. 1999;11:114-120.[Medline]
  5. Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000;36:1131-1141.[Abstract/Free Full Text]
  6. Rao V, Jamieson WRE, Ivanov J, Armstrong S, David TE. Prosthesis-patient mismatch affects survival following aortic valve replacement. Circulation 2000;102(suppl III):III5-III9.[Medline]
  7. Milano AD, De Carlo M, Mecozzi G, D'Alfonso A, Scioti G, Nardi C, et al. Clinical outcome in patients with 19-mm and 21-mm St. Jude aortic prostheses. comparison at long-term follow-up. Ann Thorac Surg 2002;73:37-43.[Abstract/Free Full Text]
  8. Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P. Impact of prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 2003;108:983-988.[Abstract/Free Full Text]
  9. Mohty-Euhahidi D, Girard SE, Malouf JF, Connolly HM, Balley KR, Sarano ME, et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude mechanical prosthesis in the aortic position. Circulation 2006;113:420-426.[Abstract/Free Full Text]
  10. Ruel M, Rubens FD, Masters RG, Pipe AL, Bedard P, Hendry PJ, et al. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves. J Thorac Cardiovas Surg. 2004;127:149-159.[Abstract/Free Full Text]
  11. Tasca G, Brunelli F, Cirillo M, DallaTomba M, Mhagna Z, Troise G, et al. Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement. Ann Thorac Surg 2005;79:505-510.[Abstract/Free Full Text]
  12. Botzenhardt F, Eichinger WB, Bleiziffer S, Guenzinger R, Wagner IM, Bauernschmitt R, et al. Hemodynamic comparison of bioprostheses for complete supra-annular position in patients with small aortic annulus. J Am Coll Cardiol 2005;45:2054-2060.[Abstract/Free Full Text]
  13. Tasca G, Brunelli F, Cirillo M, Dalla Tomba M, Mhagna Z, Troise G, et al. Impact of the improvement of valve area achieved with aortic valve replacement on the regression of left ventricular hypertrophy in patients with pure aortic stenosis. Ann Thorac Surg 2005;79:1291-1296.[Abstract/Free Full Text]
  14. Medalion B, Blackstone EH, Lytle BW, White J, Arnold JH, Cosgrove DM. Aortic valve replacement. is valve size important?. J Thorac Cardiovasc Surg 2000;119:963-974.[Abstract/Free Full Text]
  15. Hanayama N, Christakis GT, Mallidi HR, Joyner CD, Fremes SE, Morgan CD, et al. Patient prosthesis mismatch is rare after aortic valve replacement. valve size may be irrelevant. Ann Thorac Surg 2002;73:1822-1829.[Abstract/Free Full Text]
  16. Blackstone EH, Cosgrove DM, Jamieson WRE, Birkmeyer NJ, Lemmer Jr JH, Miller DC, et al. Prosthesis size and long-term survival after aortic valve replacement. J Thorac Cardiovasc Surg. 2003;126:783-793.[Abstract/Free Full Text]
  17. Knez I, Rienmüller R, Maier R, Rehak P, Schröttner B, Mächler H, et al. Left ventricular architecture after valve replacement due to critical aortic stenosis. an approach to dis-/qualify the myth of valve prosthesis-patient mismatch?. Eur J Cardiothorac Surg 2001;19:797-805.[Abstract/Free Full Text]
  18. Freed DH, Tam JW, Moon MC, Harding GE, Ahmad E, Pascoe EA. Nineteen-millimeter prosthetic aortic valves allow normalization of left ventricular mass in elderly women. Ann Thorac Surg. 2002;74:2022-2025.[Abstract/Free Full Text]
  19. Koch CG, Khandwala F, Estafanous FG, Loop FD, Blackstone EH. Impact of prosthesis-patient size on functional recovery after aortic valve replacement. Circulation 2005;111:3221-3229.[Abstract/Free Full Text]
  20. Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978;58:20-24.[Abstract/Free Full Text]
  21. Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol 1990;16:637-643.[Abstract]
  22. Dumesnil JG, Yoganathan AP. Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients. Eur J Cardiothorac Surg 1992;6:S34-S38.[Abstract/Free Full Text]
  23. Muneretto C, Bisleri G, Negri A, Manfredi J. The concept of patient-prosthesis mismatch. J Heart Valve Dis. 2004;13:S59-S62.[Medline]
  24. Castro LJ, Arcidi JMJ, Fisher AL, Gaudiani VA. Routine enlargement of the small aortic root. a preventive strategy to minimize mismatch. Ann Thorac Surg 2002;74:31-36.[Abstract/Free Full Text]
  25. Pibarot P, Dumesnil JG, Cartier PC, Métras J, Lemieux M. Patient-prosthesis mismatch can be predicted at the time of operation. Ann Thorac Surg 2001;71:S265-S268.[Medline]
  26. Connolly HM, Oh JK, Schaff HV, Roger VL, Osborn SL, Hodge DO, et al. Severe aortic stenosis with low transvalvular gradient and severe left ventricular dysfunction. result of aortic valve replacement in 52 patients. Circulation 2000;101:1940-1946.[Abstract/Free Full Text]
  27. Briand M, Dumesnil JG, Kadem L, Tongue AG, Rieu R, Garcia D, et al. Reduced systemic arterial compliance impacts significantly on LV afterload and function in aortic stenosis. implications for diagnosis and treatment. J Am Coll Cardiol. 2005;46:291-298.[Abstract/Free Full Text]
  28. Botzenhardt F, Eichinger WB, Guenzinger R, Bleiziffer S, Wagner I, Bauernschmitt R, et al. Hemodynamic performance and incidence of patient-prosthesis mismatch of the complete supraannular Perimount Magna bioprosthesis in the aortic position. Thorac Cardiovasc Surg 2005;53:226-230.[Medline]
  29. Dumesnil JG, LeBlanc MH, Cartier P, Métras J, Desaulniers D, Doyle D, et al. Distinctive hemodynamic features of the Freestyle aortic bioprothesis as compared with stented bioprosthesis. Ann Thorac Surg 1998;66:S130-S133.[Medline]
  30. Bach DS, Sakwa MP, Goldbach M, Petracek MR, Emery RW, Mohr FW. Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve. Ann Thorac Surg 2002;74:2003-2009.[Abstract/Free Full Text]
  31. Chambers J, Ely JL. Early postoperative echocardiographic hemodynamic performance of the On-X prosthetic heart valve. a multicenter study. J Heart Valve Dis 1998;7:569-573.[Medline]
  32. Laforest I, Dumesnil JG, Briand M, Cartier PC, Pibarot P. Hemodynamic performance at rest and during exercise after aortic valve replacement. comparison of pulmonary autografts versus aortic homografts. Circulation 2002;106(suppl I):57-62.[Abstract/Free Full Text]

Related Article

Prosthesis–patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: Effect on survival, freedom from heart failure, and left ventricular mass regression
Marc Ruel, Hussam Al-Faleh, Alexander Kulik, Kwan L. Chan, Thierry G. Mesana, and Ian G. Burwash
J. Thorac. Cardiovasc. Surg. 2006 131: 1036-1044. [Abstract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. Price, H. Lapierre, L. Ressler, B.-K. Lam, T. G. Mesana, and M. Ruel
Prosthesis-patient mismatch is less frequent and more clinically indolent in patients operated for aortic insufficiency.
J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 639 - 645.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. R. Moon, J. S. Lawton, N. Moazami, N. A. Munfakh, M. K. Pasque, and R. J. Damiano Jr.
POINT: Prosthesis-patient mismatch does not affect survival for patients greater than 70 years of age undergoing bioprosthetic aortic valve replacement.
J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 278 - 283.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. M. Feindel
COUNTERPOINT: Aortic valve replacement: size does matter.
J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 284 - 285.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. Mohty, J. G. Dumesnil, N. Echahidi, P. Mathieu, F. Dagenais, P. Voisine, and P. Pibarot
Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction.
J. Am. Coll. Cardiol., January 6, 2009; 53(1): 39 - 47.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J Mascherbauer, R Rosenhek, C Fuchs, E Pernicka, U Klaar, C Scholten, M Heger, G Wollenek, G Maurer, and H Baumgartner
Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality
Heart, December 1, 2008; 94(12): 1639 - 1645.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S Bleiziffer, W B Eichinger, I Hettich, D Ruzicka, M Wottke, R Bauernschmitt, and R Lange
Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement
Heart, May 1, 2008; 94(5): 637 - 641.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
N. D. Desai and G. T. Christakis
Bioprosthetic Aortic Valve Replacement: Stented Pericardial and Porcine Valves
Card. Surg. Adult, January 1, 2008; 3(2008): 857 - 894.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
M. D. Peterson, M. A. Borger, C. M. Feindel, and T. E. David
Aortic Annular Enlargement During Aortic Valve Replacement: Improving Results With Time
Ann. Thorac. Surg., June 1, 2007; 83(6): 2044 - 2049.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Takaseya, T. Kawara, S. Tokunaga, M. Kohno, Y. Oishi, and S. Morita
Aortic Valve Replacement With 17-mm St. Jude Medical Prostheses for a Small Aortic Root in Elderly Patients
Ann. Thorac. Surg., June 1, 2007; 83(6): 2050 - 2053.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
P. Pibarot and J. G Dumesnil
Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?
Heart, May 1, 2007; 93(5): 549 - 551.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Bleiziffer, W. B. Eichinger, and R. Lange
Letter by Bleiziffer et al Regarding Article, "Long-Term Outcomes After Valve Replacement for Low-Gradient Aortic Stenosis: Impact of Prosthesis-Patient Mismatch"
Circulation, December 5, 2006; 114(23): e627 - e627.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jean G. Dumesnil
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dumesnil, J. G.
Right arrow Articles by Pibarot, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dumesnil, J. G.
Right arrow Articles by Pibarot, P.
Related Collections
Right arrow Cardiac - physiology
Right arrow Congestive Heart Failure
Right arrow Valve disease
Right arrowRelated Article


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS