|
|
||||||||
J Thorac Cardiovasc Surg 2006;131:1373-1381
© 2006 The American Association for Thoracic Surgery
Cardiopulmonary Support and Physiology |
a Thoracic and Cardiovascular Surgery, Heart Center North Rhine-Westphalia, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
b Laboratory and Transfusion Medicine, Heart Center North Rhine-Westphalia, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
c Immunology and Transfusion Medicine, Ernst-Moritz-Arndt University, Greifswald, Germany.
Received for publication May 2, 2005; revisions received December 18, 2005; accepted for publication January 10, 2006. * Address for reprints: Aly El-Banayosy, MD, Heart Center NRW, Georgstrasse 11, Bad Oeynhausen, Germany, 32545. (Email: abanayosy{at}hdz-nrw.de).
| Abstract |
|---|
|
|
|---|
METHODS: Between 2003 and 2004, 115 patients received mechanical circulatory support for more than 5 days. Blood samples from postoperative day 7 were retrospectively analyzed for antiplatelet factor 4/heparin antibodies and heparin-induced platelet activation.
RESULTS: Overall, 12 (10.6%) patients had heparin-induced thrombocytopenia as defined by in vitro platelet activation, 28 (24.8%) had nonactivating antibodies, and 73 (64.6%) were classified as negative for antibodies. Patients positive for heparin-induced thrombocytopenia had the highest levels of antiplatelet factor 4/heparin immunoglobulin G antibodies. Freedom from thromboembolism was 33%, 33%, and 16% at 1, 3, and 6 months for positive patients, 77%, 68%, and 55% for negative patients (P < .001), and 70%, 53%, and 53% for patients with nonactivating antibodies (P = .068), respectively. The relative risk for thromboembolism in antibody positive patients peaked in the first month of support (odds ratio 7.46, P = .002). Independent risk factors for thromboembolic events included higher antiplatelet factor 4/heparin antibody titers, female gender, and higher fibrinogen levels.
CONCLUSION: Heparin-induced thrombocytopenia was more prevalent in patients receiving mechanical circulatory support than in other cardiac patients. Frequent antibody screening is recommended due to the increased risk of thromboembolism. Heparin alternatives should be subjected to clinical trials in these high-risk patients.
| Introduction |
|---|
|
|
|---|
To better manage these critically ill patients by choosing appropriate anticoagulation, we sought to test our clinical observation that HIT is an underappreciated problem with therapeutic challenges and serious consequences. Thus, for patients undergoing MCS, we sought to (1) evaluate prevalence, amount, and Ig classes of anti-PF4/heparin antibodies, (2) provide an assessment of heparin-induced platelet activation to diagnose or rule out HIT, and (3) determine the impact of anti-PF4/heparin antibodies on clinical outcomes.
| Methods |
|---|
|
|
|---|
|
Anticoagulation Protocol and Blood Sampling
All patients were receiving heparin before surgery, and all patients had a likely history of heparin exposure during previous hospitalizations. Only unfractionated heparin obtained from porcine intestinal mucosa was used. Assist devices were implanted during cardiopulmonary bypass with heparin used for anticoagulation (activated clotting time > 400 seconds). Heparin was reversed by protamine and then withheld for 24 hours or as long as chest tube drainage remained greater than 100 mL/h. Thereafter, all patients received heparin for several weeks postoperatively (activated partial thromboplastin time [aPTT] 40-60 seconds) and were then switched to oral phenprocoumon (international normalized ratio [INR] 2.5-3.5). Antiplatelet agents, that is, aspirin or clopidogrel, were given in selected patients beginning not before the second postoperative month.
Blood samples were obtained daily for platelet counts and standard coagulation assays, including aPTT, INR, fibrinogen, and D-dimers. Tests for the presence of anti-PF4/heparin antibodies were ordered in cases of suspected HIT at the attending physician's discretion. Indications were otherwise unexplained thrombocytopenia and/or the occurrence of thromboembolism. Additional blood samples were collected on postoperative days (POD) 5 to 7 in citrated tubes, centrifuged, and stored at 80°C. These samples were used for retrospective tests of anti-PF4/heparin antibodies and heparin-induced platelet activation. All samples were obtained from an arterial line after 10 mL of blood was withdrawn from the line.
Anti-PF4/Heparin Antibodies
The presence of antibodies to the heparin/PF4 platelet protein complex was tested by the polyspecific enzyme immunoassay GTI-PF4 (EIA GTI) (Genetic Testing Institute, Waukesha, Wis) with an optical density (OD) of 0.5 as cutoff point. All stored blood samples from PODs 5 to 7 were also tested by EIA GTI and additionally by the column agglutination assay (CAA) (DiaMed Diagnostika, Bensheim, Germany). The latter test provides a semiquantitative signal ranging from 0 (no antibodies detected) to 3 (highest level of particle agglutination). EIA GTI and/or CAA-positive blood probes were sent blinded to a reference laboratory for evaluation by custom-made mono-specific EIA (EIA Hansestadt Greifswald [HGW]) for Ig classes and by heparin-induced platelet activation assay (HIPA), as previously described.9 The combined use of HIPA with mono-specific EIA was validated for diagnosing HIT in previous studies.10 Specifically, antibodies testing positive by the HIPA were considered clinically relevant HIT antibodies. If the HIPA showed heparin-independent platelet activation, the test was designated indeterminate. Only in those cases, an IgG class antibody titer of OD greater than 1.0 defined clinically relevant HIT antibodies. Conversely, HIPA negative antibodies were considered clinically not relevant regardless of their IgG titer. Finally, all IgA and IgM antibodies were considered irrelevant.
Data Analysis
Data are presented as percentage, mean ± standard deviation, or 95% confidence interval. Several demographic, procedural, and laboratory variables were considered as potential risk factors for thrombotic events (Appendix E2). Univariate comparisons were made by the Mann-Whitney test, Student t test, Kendall tau,
2 test, or 1-way analysis of variance with Bonferroni post-hoc testing, as appropriate. Those factors with a statistically significant difference (P < .10) were then included stepwise (forward and backward) in a multivariate logistic regression with thrombotic event as the dependent variable. The model was built with 64 randomly selected patients and then validated on the remaining 51 patients. Variables were retained in the model at a significance level of P < .05. The distribution of clinical events over time was analyzed by nonparametric Kaplan-Meier estimates, followed by a log-rank test. Clinical events per time interval were compared with the
2 test, and their relative risk was calculated. Predictive capabilities of various anti-PF4/heparin antibody tests with respect to the occurrence of thromboembolism were estimated by Bayesian reasoning. All analyses were performed with SPSS 12.0 (SPSS Inc, Chicago, Ill).
| Results |
|---|
|
|
|---|
|
|
Among 51 patients tested for HIT, 12 patients (24%) had anti-PF4/heparin antibodies by the polyspecific EIA GTI during their hospital stay. Of these, 6 patients were retrospectively confirmed by HIPA+&id/IgG+. One patient emerged as HIPA/IgG,A,M+ and 5 patients were found to be HIT negative.
Heparin was suspended in 12 patients once they were found positive by the EIA GTI, and lepirudin or antiplatelet acetylsalicylic acid and/or epoprostenol was substituted. Despite alternative anticoagulation, all 6 patients later confirmed as HIPA+&id/IgG+ had thromboembolic events (Table E2). The 1 patient with HIPA/IgG,A,M+ status had cerebral bleeding (POD 9) while receiving lepirudin, and 1 HIT negative patient receiving epoprostenol had a cerebral transitory ischemic attack (TIA) with no residuals (POD 8). Furthermore, 1 HIT negative patient had a TIA long after epoprostenol treatment while receiving phenprocoumon (POD 133) and 3 HIT negative patients remained free of thromboembolism.
|
|
|
|
|
|
|
|
|
| Discussion |
|---|
|
|
|---|
Anti-PF4/Heparin Antibodies During MCS
Anti-PF4/heparin antibodies are frequently observed in patients undergoing cardiac surgery, but seroconversion was not associated with increased risk of thromboembolism in a prior study.
3
HIT develops in only 1% to 3% of patients after cardiac surgery despite their high rate of seroconversion.
5
Selected studies explain this discrepancy by the avoidance of postoperative heparin administration.
3
However, other studies report the postoperative thrombosis rate to remain low despite postoperative heparin treatment.
5
In patients receiving MCS, as many as 60% were found to be anti-PF4/heparin antibody positive.
11
Interestingly, about one third of anti-PF4/heparin antibody positive patients had a thromboembolism, yet the authors did not note any thrombotic event in patients without anti-PF4/heparin antibodies.
11
In contrast, our study clearly documents that the patients without PF4/heparin antibodies were at risk for new thrombotic complications, although the risk was 7-fold lower than in antibody-positive patients. Importantly, platelets and coagulation systems during MCS are activated by the underlying heart failure with impairment of other organ systems as well as by the large prosthetic surfaces of the devices.
12,13
The contribution of these factors may in turn explain our finding that clinical HIT occurs in as many as 11% of patients receiving MCS. Of note, the diagnosis of clinical HIT was vigorously substantiated by the reference laboratory remaining blinded to the clinical course of the patients, showing heparin-induced platelet activation
10
and expression of IgG classes of anti-PF4/heparin antibodies.
14
Furthermore, the high number of HIT positive patients receiving MCS may be paralleled by patients undergoing heart transplantation. Indeed, Hourigan and associates
15
reported 11 of 46 transplant patients having clinical HIT. Although this report has to be interpreted with caution as the study was not supported by platelet functional tests or IgG class antibody titers, together with our study it indicates that the manifestation of clinical HIT could be pronounced in major invasive cardiac procedures such as MCS and heart transplantation. Finally, our data are in agreement with studies of orthopedic patients, showing that the quantity of anti-PF4/heparin antibodies correlated with the magnitude of in vivo coagulation and incidence of thromboembolism.
16,17
The higher the titer of anti-PF4/heparin antibodies, the more likely were our patients to have thrombotic events.
The expression of anti-PF4/heparin antibodies of less pathogenic potential, classified as HIPA/IgG,A,M+, is another issue clarified by our work. These antibodies were found in 25% of patients and had no platelet-activating properties. The lack of platelet activation may in turn explain the similarly low risk of thromboembolism as observed in anti-PF4/heparin antibody negative patients. Thus, differentiation between clinically relevant anti-PF4/heparin antibodies ("HIT antibodies") and those with minor pathogenic potential will become essential for patient management. Since the commercially available EIAs do not distinguish between Ig classes, our study additionally explains why some patients with a positive EIA result can develop thromboembolism whereas others do not. Future investigations may focus on whether these antibodies can transform into "true" HIT antibodies on continuous heparin exposure.
Platelet Counts
Our finding that platelet counts did not differ across all groups deserves consideration. Whereas the drop of platelets until POD 5 was likely due to the use of cardiopulmonary bypass,
5
thereafter, platelet count profiles were influenced by platelet damage during MCS.
12,13
Frequent platelet transfusion may have augmented platelet counts and thus prevented a second drop of platelet counts after POD 5 that would otherwise have indicated development of HIT antibodies.
4
Furthermore, since most patients were exposed to heparin treatment during their moribund illness, anti-PF4/heparin antibodies may have been preformed. These preformed antibodies may in turn induce "rapid-onset HIT" on repeat heparin exposure, also leading to an early drop of platelets.
18
These possibilities might also explain the relative increase of platelet counts as percent change from baseline after POD 10 in HIPA+&id/IgG+ patients. Indeed, the platelet count profiles indicate an increased platelet turnover in HIT patients possibly due to elevated thrombopoietin levels. Additionally, the more pronounced increase of relative platelet counts in HIPA+&id/IgG+ patients may be consistent with the model of increased intravascular platelet activation by pathologically relevant HIT antibodies. Nevertheless, platelet counts were not found indicative of HIT in patients receiving MCS. It is an evolving concept that HIT can manifest with a new thrombotic complication without a major decrease in platelet count, as has been shown by a retrospective analysis of 408 HIT patients
19
and by a prospective cohort study.
20
Implications
These findings have important implications for the management of patients receiving MCS and suggest that monitoring of anti-PF4/heparin antibodies may be relevant to identifying patients with increased risk of thrombotic events. Thromboembolism, for example, cerebrovascular accidents, is a common issue with an incidence of 6% to 30%.
8,21,22
The current study demonstrates that the risk of early thromboembolic events was 7-fold higher in anti-PF4/heparin antibody positive patients and related to anti-PF4/heparin antibody titers. Thromboembolism, while nonfatal in most cases, was likely to affect morbidity, quality of life, and costs. Therefore, routine preoperative and postoperative antibody screening by polyspecific EIA and/or CAA is recommended. Patients without anti-PF4/heparin antibodies have a very low likelihood of HIT-associated thromboembolism due to the great sensitivity and negative predictive value of the tests. However, patients with anti-PF4/heparin antibodies should undergo additional assessment of Ig classes as well as platelet activating properties. This approach enhances diagnostic specificity and positive predictive value for new thromboembolic events. We now introduce the HIPA for those purposes, although this complex test requires strict quality control measures.
23
Alternatively, the serotonin-release assay may be used to confirm heparin-induced platelet activation with similar sensitivity and specificity.
6,9,24
However, this test requires the use of radioactive tracers and, therefore, is mostly abandoned in our institutions.
Current heparin alternatives, that is, lepirudin, danaparoid and argatroban, bear substantial risk of bleeding due to lack of antagonists and difficulties in monitoring.
25
Since only about 1 of 3 patients with a positive EIA result had indeed clinically relevant HIT antibodies, stratification according to anti-PF4/heparin Ig classes and HIPA is necessary before heparin is discontinued. Bivalirudin, another direct thrombin inhibitor and now in clinical trials,
26
may be a promising alternative due to its short-acting mechanism by blood protease cleavage. Further investigations are required to assess the safety and efficacy of these heparin alternatives in patients receiving MCS.
Limitations
Blood samples for detailed analyses of anti-PF4/heparin antibodies were available only at PODs 5 to 7. Thus, we were unable to investigate the kinetics of antibody production and seroconversion over time. Anti-PF4/heparin antibodies may be expressed only transiently,
18
and patients whose antibodies disappeared after POD 7 should be at a lower risk of thromboembolism. In contrast, those patients in whom antibody titers were detectable only after POD 7 are likely to have a higher risk of thrombotic events. Finally, since only frozen samples were available for detailed analyses of anti-PF4/heparin antibodies, test sensitivities of EIA HGW and HIPA may have been too low in some cases. Thus, the relevance of HIT antibodies may have even been underestimated as compared with using fresh blood samples.
| Conclusion |
|---|
|
|
|---|
| Discussion |
|---|
|
|
|---|
First of all, what type of heparin did these patients receive? Previous studies have shown that the incidence of positive heparin antibodies can be reduced by as much as a third by using pork instead of beef heparin. In your study did you notice any difference between pork and beef heparin and the incidence of thromboembolic events?
Dr El-Banayosy. We are using pork heparin in all of our patients.
Dr Lazar. Second, in your study you used both the enzyme-linked immunosorbent assay and the CAA to detect antiplatelet antibodies and thromboelastography to detect hypercoagulability. Since the decision to discontinue heparin is very important and the development of the thromboembolic event is devastating to these patients, on the basis of your data, what tests would you use to determine when heparin should be avoided, and would you recommend obtaining these tests in all patients before putting them on MCS devices?
Dr Schenk. We know that about 50% of all patients have antibodies, but only 1% to 3% of those patients have the clinical HIT symptoms. We also know that there are several immunoglobulins, for example, IgG, IgA, and IgM, that are relevant, and, as you mentioned, those tests only assess the overall number of those antibodies. We cannot distinguish among IgA, IgG, and IgM by the commercially available tests.
As to your point, we have to look for the presence of the clinically relevant antibodies, and we would also now add some additional testing. For example, we would add some platelet function tests, which can distinguish between those antibodies that are more pathogenic versus the others. That has been introduced now; unfortunately, we did not do that during the time frame of our study period.
The decision to discontinue heparin and to switch to another intravenous anticoagulant is based on an evaluation of all available laboratory tests together with clinical signs suggestive of HIT. If platelet counts have not recovered, oral anticoagulants should not be administered. If the patient no longer has low platelet counts, oral anticoagulants can be used as the clinical situation requires, and we do this with thromboelastogram guidance.
Dr Lazar. Finally, in view of your poor results with lepirudin and the platelet aggregate inhibitors, what therapeutic agents would you recommend for patients when heparin must be discontinued? Do you have any experience with bivalirudin (Angiomax), which seems to be used increasingly by our interventional cardiologists during angioplasty procedures for acute coronary syndromes?
Dr Schenk. Unfortunately, as of now we have not used the drug that you mentioned, but in our current patients we are using lepirudin, which is an analogous agent to bivalirudin. However, we did observe many side effects, and most of the time we are very concerned about bleeding complications. We observed many patients who did receive lepirudin and had bleeding complications.
When we have a patient with these antibodies, we try to give platelet stabilizing factors as soon as we can. For instance, there is one drug named dipyridamole (Persantine), and because that seems to stabilize platelet function, it may be especially useful in cases of HIT. In addition, we try to give aspirin and clopidogrel as well, which may have beneficial effects.
Dr Ralph Damiano (St Louis, Mo). Could you comment on your strategies in the patients who were HIT positive? I assume a number of these patients were bridged to transplant. Did you find a higher mortality at the time of the transplantation, and what were your strategies for managing the patients during that period?
Dr Schenk. The first part of your question concerns outcome related to survival. We did not see any difference in survival. Why that is, we do not know yet, but there was no difference in survival between antibody positive and negative patients.
The second part of your question concerns what we give if the patient has had HIT antibodies before. What do we do during transplant? HIT antibodies are transiently expressed. As long as you use heparin, the patient obviously is at risk. However, if you discontinue heparin, then those antibodies will likely disappear. If you re-evaluate those antibodies after 12 to 18 months when the patient is coming back for transplant, most of the time those antibodies are not effective anymore. Therefore, if you have a patient who had a history of HIT but has no current antibodies, there is no reason not to give heparin during cardiopulmonary bypass. Of course, you have to screen those antibodies closely, and as soon as antibodies come back, you had better give something else.
Dr Steven Bolling (Ann Arbor, Mich). Your unit uses many different types of circulatory support. Was there a different rate of HIT positivity associated with different ventricular assist or circulatory support devices? Were there heparin-bonded surfaces in these devices? The numbers may be small.
Dr Schenk. Thank you very much. This is a pretty important question because it emphasizes the pathology of that disease. We do not believe that this is device-related. Of course, we cannot prove that because we would have to have higher numbers and do a multivariable analysis. However, the only factor that is known to cause HIT is obviously heparin, and even if one device is found to be more related to HIT than the other, it is our belief that this is more treatment-related than device-related. I agree with you that HIT may be more prevalent with certain devices, but this should be related to the clinical indication for the device. For example, our patients who receive a CardioWest total artificial heart (SynCardia Systems, Inc, Tucson, Ariz) are among the sickest. They are usually receiving extracorporeal membrane oxygenation, they are usually in cardiogenic shock, and they are likely to be in the intensive care unit for some days to several weeks with heparin exposure as well. If you see a higher incidence of HIT positive patients, for example, with this particular device, then I think this is a matter of whether and how much heparin you gave before implant.
In addition, there is also reason to believe that there is an analogy to the HLA sensitization. There was a study done by the Cleveland Clinic last year. When they compared their HeartMate (Thoratec Corporation, Pleasanton, Calif) versus Novacor (WorldHeart Corporation, Oakland, Calif) data, they found that HLA sensitization was essentially not device-related; it was treatment-related, essentially a matter of the number of blood products used and not contingent on the device at all. So one thought I come back to is this: heparin is given before, during, and after surgery and therefore those antibodies may be produced in quite a number and with better specificity and for a longer time. I think it stands to reason that heparin is the only factor that causes HIT syndrome. On the other hand, since so much heparin is given, the likelihood of having HIT syndrome is probably among the highest in patients receiving MCS.
Dr El-Banayosy. I would like to make a short comment on that. Regarding the differences between the devices, we found that we had a higher incidence in the patients supported with the CardioWest total artificial heart. It might be due to the fact that the patients supported with a total artificial heart in our institution are the sickest cohort of patients and they have received heparin longer. But the numbers, as I mentioned, were not too high to allow us to see a statistically significant difference.
Dr Keith Allen (Indianapolis, Ind). I enjoyed your talk. Our group has had the opportunity to participate in some controlled trials using bivalirudin as an alternative to heparin. You suggested in one of your answers that in using lepirudin, which is one of the three direct thrombin inhibitors that are available, you had increased bleeding complications. I would like the audience to understand that the three direct thrombin inhibitors are not created equal. The problem you are having with lepirudin is related to its longer half-life and the inability to have any type of marker to measure the degree of anticoagulation. Bivalirudin has a shorter half-life and its anticoagulation can be measured. Therefore, I would argue that bivalirudin is a very attractive alternative to heparin in a patient with a left ventricular assist device.
Dr Eric A. Rose (New York, NY). There have been devices that have actually been designed to include a heparin coating on them. One such device that we have worked with is the MicroMed DeBakey device (MicroMed Technology, Inc, Houston, Tex). After review of outcomes looking at the heparin-coated versus the noncoated devices, we actually reached the conclusion that it offered no advantage and perhaps a disadvantage. Essentially, a device that is coated with heparin is almost potentially a heparin vaccine, and I think that is an important issue that needs to be part of device design.
Dr Schenk. Maybe I can add a dissenting point. In a study from the Berlin group done about 3 years ago, the Berlin Heart (Berlin Heart AG, Berlin, Germany), which is heparin-coated, was compared with other devices that are not. The Berlin group did not find any higher incidence of heparin antibodies between the groups with coated versus noncoated tubing. This actually would argue against the statement or against this idea that heparin coating is a bad thing to do. I think it is reasonable to say that heparin that is bound to a device may not be as immunogenic as heparin that is unfractionated and streams freely in the blood.
| Appendix E1 |
|---|
|
|
|---|
| Appendix E2 |
|---|
|
|
|---|
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
T. E. Warkentin, A. Greinacher, and A. Koster Heparin-induced thrombocytopenia in patients with ventricular assist devices: are new prevention strategies required? Ann. Thorac. Surg., May 1, 2009; 87(5): 1633 - 1640. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. E. Warkentin, A. Greinacher, A. Koster, and A. M. Lincoff Treatment and Prevention of Heparin-Induced Thrombocytopenia: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines (8th Edition) Chest, June 1, 2008; 133(6_suppl): 340S - 380S. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Weiss, L. W. Miller, and F. D. Pagani Continuous-Flow Ventricular Assist Device N. Engl. J. Med., November 29, 2007; 357(22): 2305 - 2306. [Full Text] [PDF] |
||||
![]() |
A. Koster Reply Ann. Thorac. Surg., October 1, 2007; 84(4): 1423 - 1424. [Full Text] [PDF] |
||||
![]() |
J. N. Schroder, M. A. Daneshmand, N. R. Villamizar, R. P. Petersen, L. J. Blue, I. J. Welsby, A. J. Lodge, T. L. Ortel, J. G. Rogers, and C. A. Milano Heparin-Induced Thrombocytopenia in Left Ventricular Assist Device Bridge-to-Transplant Patients Ann. Thorac. Surg., September 1, 2007; 84(3): 841 - 846. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. E. Warkentin and M. A. Crowther When is HIT Really HIT? Ann. Thorac. Surg., January 1, 2007; 83(1): 21 - 23. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |