J Thorac Cardiovasc Surg 2007;133:2-6
© 2007 The American Association for Thoracic Surgery
Cardiopulmonary Support and Physiology |
a Department of Cardiothoracic Surgery, University of Vienna, Vienna, Austria
b Department of Medicine III, Clinical Division of Endocrinology and Metabolism, University of Vienna, Vienna, Austria
c Department of Laboratory Diagnostics, University of Vienna, Vienna, Austria
d Ludwig Boltzmann Institute for Cardiosurgical Research, University of Vienna, Vienna, Austria.
Received for publication July 12, 2002; revisions received January 13, 2003; accepted for publication March 13, 2003. * Address for reprints: Martin Clodi, MD, Department of Medicine III, Clinical Division of Endocrinology and Metabolism, University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria. (Email: martin.clodi{at}akh-wien.ac.at).
| Abstract |
|---|
|
|
|---|
METHODS: Eight male patients and 1 female patients (mean age, 51 ± 10 years) with end-stage left-sided heart failure were implanted with a MicroMed-DeBakey axial pump. After a mean period of 67 ± 19 days, basal pituitary hormone concentrations and their responses to a bolus injection of hypothalamic releasing hormones were tested. In addition, thyroid hormones, testosterone, and plasma and urinary catecholamine levels were measured at baseline.
RESULTS: Administration of the hypothalamic releasing hormones revealed normal responses of all pituitary hormones (adrenocorticotropic hormone, thyroid-stimulating hormone, luteinizing hormone, and prolactin), except for growth hormone, the response of which was slightly impaired (10.2 ± 6.8 vs 19.9 ± 6.5 ng/L, P < .05). Also, the cortisol response to the corticotropin-releasing hormonestimulated adrenocorticotropic hormone release was normal, as were basal concentrations of thyroid hormones (triiodothyronine, thyroxine, free triiodothyronine, and free thyroxine), testosterone, and urinary catecholamines.
CONCLUSIONS: Implantation of a continuous flow axial pump with low-pulsatile blood flow profile appears to have no major effect on the hypothalamic-pituitary-endorgan system and sympathoadrenal functions. This finding is reassuring for the growing number of patients treated with this convenient new pump and could contribute considerably to their prognosis and quality of life.
| Introduction |
|---|
|
|
|---|
Disturbed neuroendocrine and sympathoadrenal function caused by nonphysiologic organ perfusion could be expected to have a major effect on cardiovascular and muscular function in patients with severe left-sided heart failure and thereby limit the beneficial hemodynamic effects of a miniaturized implantable system. Indeed, several studies have suggested adrenocortical dysfunction during nonpulsatile perfusion in human subjects.5
In contrast, early experiments with nonpulsatile blood pumps in animals provided evidence that this pathophysiologic state of nonpulsatile or low-pulsatile blood flow can be tolerated for short-term support, despite alterations in the microcirculation.6
Because the effect of long-term low pulsatility on the endocrine system is not known, we performed pituitary gland multifunction tests in patients implanted with a continuous MicroMedDeBakey axial flow pump and evaluated their pituitary and associated endocrine functions, as well as their sympathoadrenal states.
| Methods |
|---|
|
|
|---|
All tests were performed at 10 AM, and all subjects were starved for at least 8 hours. Patients were tested for basal serum hormone concentrations and anterior pituitary hormone response to bolus injection of hypothalamic releasing hormones (corticotropin-releasing hormone [CRH], 100 µg: Ferring, Kiel, Germany; thyreotropin-releasing hormone, 200 µg: Aventis Pharma, Frankfurt, Germany; growth hormone [GH]releasing hormone, 100 µg: Ferring; luteinizing hormonereleasing hormone, 100 µg, Aventis Pharma). Blood samples were assayed for adrenocorticotropic hormone (ACTH), cortisol, thyroid-stimulating hormone (TSH), luteinizing hormone (LH), GH, and prolactin at multiple time points (15, 0, 15, 30, 60, 90, and 120 minutes). In addition, we measured basal serum concentrations of thyroid hormones, testosterone, the binding proteins thyroxin-binding globulin and sex hormonebinding globulin, and plasma and urinary catecholamines (epinephrine, norepinephrine, and dopamine). Blood for determination of plasma ACTH concentrations was drawn in prechilled ethylenediamine tetraacetic acid tubes that were immediately centrifuged and stored at 20°C until assayed with a commercially available radioimmunoassay. GH, cortisol, and sexual hormonebinding globulin levels were measured with commercially available radioimmunoassays. Serum concentrations of triiodothyronine (T3), thyroxine (T4), free T3, free T4, testosterone, TSH, LH, and prolactin were measured by using electrochemiluminescence (ELECSYS, Roche Diagnostics GmbH, Mannheim, Germany). Epinephrine, norepinephrine, and dopamine excretion in 24-hour urinary samples was analyzed by using high-performance liquid chromatography.
Data are expressed as medians and standard errors of the mean. To analyze individual serial measurements of ACTH, cortisol, TSH, LH, GH, and prolactin, we calculated the area under the curve according to the trapezoid rule7
divided by the elapsed time interval. Further maximum increase of ACTH, cortisol, TSH, LH, GH, and prolactin was calculated for each patient. The MannWhitney U test was used to compare groups of continuous data. All data were computed with Microsoft Excel for Windows, version 6.0 (Microsoft, Redmond, Wash) and SPSS for windows (SPSS, Chicago, Illinois).
| Results |
|---|
|
|
|---|
|
|
| Discussion |
|---|
|
|
|---|
It has been shown recently, however, that maintenance of systemic circulation with implanted continuous axial flow blood pumps for bridge to transplantation is feasible and well tolerated in patients for several months.3,4
Problems experienced in early animal experiments, such as increased total peripheral resistance, increased circulating blood volume, reduced oncotic pressures, and low hematocrit values,6
were not seen in these first patients with implanted axial flow pumps. It is known that essential organs of the body are able to autoregulate their perfusion pressures in a certain range to maintain an adequate blood flow to guarantee regular metabolism and protect themselves from damage. The brain, for instance, keeps cerebral blood flow constant over a range of approximately 60 to 150 mm Hg mean aortic pressure. It has been observed, however, that cerebral blood flow and cerebral metabolic rate for oxygen are reduced by approximately 30% during cardiopulmonary bypass surgery when a nonpulsatile pump flow mode is maintained.8
Furthermore, it is known that patients with advanced chronic heart failure present with endocrine dysregulations. In chronic heart failure norepinephrine, epinephrine, cortisol, prolactin, and human GH levels are increased, and thyroid function is impaired. Insulin-like growth factor I, testosterone, and estrogen levels appear to be normal.9-11
This study demonstrates that adenohypophyseal function in response to stimulation by hypothalamic releasing hormones is maintained in patients, except for GH, the response of which was diminished. It should be stressed, however, that no single patient exhibited severe GH deficiency, defined as a maximal GH concentration of 3 µg/L or less at the Port Stephens Consensus Conference.12
Because of the positive inotropic effects of GH, the finding of only mild impairment of somatotropic function appears to be relevant in patients with heart failure.13,14
Normal or only slightly impaired GH concentrations also facilitate physical training15
and rehabilitation of these patients, which must be considered of great importance for further prognosis and outcome after heart transplantation.
Furthermore, hypothalamic-pituitary-adrenocortical function was not impaired in our patients with implanted devices, as evidenced by a normal cortisol response to a normal ACTH increase after administration of a maximally effective dose of CRH. The criteria for intact adrenal function include the attainment of a maximal plasma cortisol concentration of at least 18 µg/dL, a cortisol increment of at least 7 µg/dL greater than the basal value, or both. This finding is not only remarkable in view of the nonpulsatile blood flow but also points toward a well-adapted general health condition of patients with MicroMedDeBakey axial flow pumps implanted for a mean time of 67 ± 19 days. Chronic stress as a consequence of a severely impaired general health status would have lead to increased cortisol concentrations and deranged hypothalamic-pituitary feedback, with deleterious effects on cardiovascular, metabolic, and immune functions.16-18
Furthermore, this observation is in agreement with previous studies during and after cardiopulmonary bypass surgery using pulsatile and nonpulsatile perfusion.19,20
In contrast, several earlier studies had suggested that nonpulsatile blood flow during cardiopulmonary surgery decreases plasma cortisol levels,5
which also might be expected to compromise cardiovascular function caused by impairment of fluid and mineral homeostasis and the loss of the permissive effects of glucocorticoids for catecholamines in peripheral blood vessels. Because our investigations were performed about 70 days after implantation of the MicroMedDeBakey VAD, we cannot rule out that the patients might have adapted themselves to the nearly nonpulsatile flow pattern. Tsutsui and Nose21
report in early animal experiments with complete nonpulsatile flow that idioperipheral pulsations could be observed. They suggested that the animals were able to add pulsatile components of their own, allowing them to maintain sufficient circulation. From our patients with implanted continuous blood pumps, we learned that pulsatility of blood flow occurs as soon as contractility of the natural heart recovers.3,4
Whereas high catecholamine levels have been described in patients with cardiomyopathy and immediately after implantation of mechanical assist devices,22,23
we found normal plasma catecholamine concentrations and urinary catecholamine excretion. This further suggests good physical adaptation of our patients maintained several weeks after implantation of the DeBakey VAD.
No changes versus those seen in healthy subjects were seen as to thyroid hormone concentrations. This is in contrast to a study by Buket and colleagues,24
in which nonpulsatile flow has been shown to affect thyroid hormone levels. In this study both pulsatile and even more nonpulsatile flow decreased free T3 levels but not TSH, T4, and free T4 levels. Such low T3 syndrome was observed within 24 hours after cardiopulmonary bypass surgery and is related to the severe medical condition of these patients rather than to the choice of cardiac assist device.25
The normal thyroid function test results again document the good physical condition of our patients and their adaptation to the nonpulsatile blood flow pump 70 days after implantation of the assist device.
In conclusion, this study demonstrates an almost normal endocrine regulation in patients receiving a continuous MicroMedDeBakey axial flow pump. This proves that prolonged support with a nonpulsatile mechanical assist device is well tolerated by endocrine organs, which play a major role in the maintenance of homeostasis in human subjects. In addition, this finding documents the good long-term adaptation of these patients, which could have a major effect on their prognosis and quality of life.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
V. Mazzei, G. Nasso, G. Salamone, F. Castorino, A. Tommasini, and A. Anselmi Prospective Randomized Comparison of Coronary Bypass Grafting With Minimal Extracorporeal Circulation System (MECC) Versus Off-Pump Coronary Surgery Circulation, October 16, 2007; 116(16): 1761 - 1767. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||