JTCS Medtronic Endurant
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Timothy P. Martens
Mark J. Russo
Faisal H. Cheema
Stephen H. Bailey
Yoshifumi Naka
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schulman, A. R.
Right arrow Articles by Naka, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schulman, A. R.
Right arrow Articles by Naka, Y.

J Thorac Cardiovasc Surg 2007;133:841-842
© 2007 The American Association for Thoracic Surgery


Brief Communication

Comparisons of infection complications between continuous flow and pulsatile flow left ventricular assist devices

Allison R. Schulman, BAa, Timothy P. Martens, MDa, Paul J. Christos, MPH, MSb, Mark J. Russo, MD, MSa, George M. Comas, MDa, Faisal H. Cheema, MDa, Tariq M. Naseem, MDa, Raymond Wang, BAa, Katharine A. Idrissi, MSNa, Stephen H. Bailey, MDa, Yoshifumi Naka, MD, PhDa,*

a Division of Cardiothoracic Surgery, Columbia University Medical Center, New York, NY
b Division of Biostatistics and Epidemiology, Department of Public Health, Weill Medical College of Cornell University, New York, NY.

Received for publication September 23, 2006; accepted for publication September 28, 2006.

* Address for reprints: Yoshifumi Naka, MD, PhD, Division of Cardiothoracic Surgery, 177 Fourth Washington Ave, MHB 7-435, New York, NY 10032. (Email: yn33{at}columbia.edu).

The implantation of a left ventricular assist device (LVAD) both as a bridge to transplantation and as destination therapy is being used with increasing frequency in patients with end-stage heart failure. Two main types of LVADs are currently being used: pulsatile and continuous flow devices. Continuous devices are much smaller and produce a continuous flow with either an axial or centrifugal flow pump. These devices fill during both the systolic and diastolic phase.1Go

Despite the overall success of LVAD support and the advances in design in both types of devices, infection continues to be a common morbidity of mechanical circulatory support and remains a serious threat to the long-term survival of patients using LVADs.2,3Go This study was designed to determine the differences in infection rates between patients with puslatile pumps (HeartMate I; Thermo Cardiosystems, Inc, Woburn, Mass) versus those with axial flow devices (HeartMate II or DeBakey; MicroMed Technology, Inc, Houston, Tex).

Patients and Methods

We retrospectively reviewed the case histories of 92 patients undergoing LVAD implantation at a single center between October 2003 and April 2006. This analysis captured the first 27 axial flow device implants at our center, as well as every HeartMate I device implanted during the same interval. LVADs were classified as pulsatile (n = 65) or continuous flow (n = 27). Local device infection was defined by clinical signs of infection with positive culture(s) from the abdominal wound, driveline, pocket, or pump. The {chi}2 test was used to analyze the associations between device type and categorical variables (device infections, gender, preoperative history of diabetes or hypertension, bridge-to-transplant rate, and post-implant 1-year survival), and the nonparametric Mann–Whitney test was used to analyze associations between device type and continuous variables (age, height, body surface area [BSA], and body mass index [BMI]).

Results

Findings are summarized in Table 1. There were no significant differences between pulsatile and continuous device groups with respect to age, gender, height, or preoperative history of diabetes or hypertension. BSA (2.0 vs 1.89; P = .035) and BMI (28.6 vs 24.9; P = .009) were significantly higher in patients with pulsatile devices. Patients with pulsatile devices were more likely to have an LVAD-related infection (18/65 vs 1/27, 27.7% vs 3.7%; P = .010), in particular pocket infections (10/65 vs 0/27, 15.4% vs 0%; P = .031) and wound infections (10/65 vs 0/27, 15.4% vs 0%; P = .031). Of note, the rates of driveline infection (9/65 vs 2/27, 13.8% vs 7.4%; P = .271) and pump endocarditis (2/62 vs 1/26, 3.2% vs 3.7%; P = .999) were comparable between the two groups. Device infections had no effect on bridge-to-transplant rate (15/18 vs 39/56, 83.3% vs 69.6%; P = .364) or postimplant 1-year survival (13/19 vs 50/71, 68.4% vs 70.4%; P = .999) in either group.


View this table:
[in this window]
[in a new window]

 
TABLE 1 Demographic profile and infection rates for all patients with left ventricular assist devices (LVADs)
 
Discussion

Differences in infection rates between pulsatile and continuous flow LVADs may be a reflection of differences in device design. Continuous flow devices are smaller and do not have compliance chambers, polyurethane membranes, or prosthetic valves that pulsatile devices have.4Go The larger implanted surface and the pooling of fluid that may surround the pulsatile devices promote microbial adhesion and growth.2Go Furthermore, continuous flow devices need only a small pump pocket and do not require a great deal of surgical dissection. These characteristics collectively may explain the low infection rate. This difference in device size underlies the significant difference in BMI and BSA between the two groups; smaller patients who are not candidates for the HeartMate I LVAD are often able to accommodate the comparatively smaller continuous flow pumps.

Results from this single-center analysis support the hypothesis that continuous flow LVADs have reduced infection rates. Surprisingly, there was no difference in pump endocarditis. Perhaps this can be attributed to a definition of infection that is too stringent—broad-spectrum antibiotic use may suppress bacterial growth and lead to false negative cultures in the setting of true device infection. Alternatively, this finding may reflect improved infection control in the post-REMATCH* era. Optimal implantation techniques, tight glucose control, and meticulous surgical site care may all contribute to decreased LVAD infection rates.

It is not surprising that there is no significant difference in driveline infection rates between pulsatile and continuous flow LVADs, because both devices require an abdominal exit site that connects the pump to an external power source. The high incidence of driveline infection in the literature highlights the importance of improving on currently used technology. Furthermore, deep driveline tract infections often result in pocket and/or device infections that may be refractory to medical treatment.5Go Further development of transcutaneous energy transmission systems may further reduce infection rates by eliminating the need for drivelines.

Footnotes

* REMATCH = Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure. Back

References

  1. Klotz S, Deng M, Stypmann J, Roetker J, Wilhelm MJ, Hammel D, et al. Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. Ann Thorac Surg 2004;77:143-149.[Abstract/Free Full Text]
  2. Holman WL. Managing device infections: are we progressing or is infection an insurmountable obstacle?. ASAIO J 2005;51:452-455.[Medline]
  3. Simon D, Fischer S, Grossman A, Downer C, Hota B, Heroux A, et al. Left ventricular assist device-related infection: treatment and outcome. Clin Infect Dis 2005;40:1108-1115.[Abstract/Free Full Text]
  4. Vitali E, Lanfranconi M, Ribera E, Bruschi G, Colombo T, Frigerio M, et al. Successful experience in bridging patients to heart transplantation with the MicroMed DeBakey ventricular assist device. Ann Thorac Surg 2003;75:1200-1204.[Abstract/Free Full Text]
  5. Yuh D, Albaugh M, Ullrich S, Conte JV. Treatment of ventricular assist device driveline infection with vacuum-assisted closure system. Ann Thorac Surg 2005;80:1493-1495.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
World Journal for Pediatric and Congenital Heart SurgeryHome page
D. A. Hehir, R. A. Niebler, C. C. Brabant, J. S. Tweddell, and N. S. Ghanayem
Intensive Care of the Pediatric Ventricular Assist Device Patient
World Journal for Pediatric and Congenital Heart Surgery, January 1, 2012; 3(1): 58 - 66.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
V. K. Topkara, S. Kondareddy, F. Malik, I.- W. Wang, D. L. Mann, G. A. Ewald, and N. Moazami
Infectious Complications in Patients With Left Ventricular Assist Device: Etiology and Outcomes in the Continuous-Flow Era
Ann. Thorac. Surg., October 1, 2010; 90(4): 1270 - 1277.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
L. H. Lund, J. Matthews, and K. Aaronson
Patient selection for left ventricular assist devices
Eur J Heart Fail, May 1, 2010; 12(5): 434 - 443.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. Hendry
Invited commentary
Ann. Thorac. Surg., August 1, 2007; 84(2): 520 - 521.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Timothy P. Martens
Mark J. Russo
Faisal H. Cheema
Stephen H. Bailey
Yoshifumi Naka
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schulman, A. R.
Right arrow Articles by Naka, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schulman, A. R.
Right arrow Articles by Naka, Y.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS