|
|
||||||||
J Thorac Cardiovasc Surg 2007;133:1004-1011
© 2007 The American Association for Thoracic Surgery
Surgery for Acquired Cardiovascular Disease |
Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
Read at the Eighty-sixth Annual Meeting of The American Association for Thoracic Surgery, Philadelphia, Pa, April 29-May 3, 2006.
Received for publication May 1, 2006; revisions received October 19, 2006; accepted for publication October 26, 2006. * Address for reprints: Masashi Komeda, MD, PhD, Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin kawahara-cho, Sakyo-ku, Kyoto, Japan 606-8507. (Email: komelab{at}kuhp.kyoto-u.ac.jp).
| Abstract |
|---|
|
|
|---|
Methods: Six mongrel dogs had sonomicrometry crystal markers implanted in the left ventricle, mitral annulus, and papillary muscle tips. After the secondary chordae tendineae of the anterior mitral leaflet from each papillary muscle were resected, each papillary muscle tip was connected to the mid-anterior mitral annulus with 4-0 polypropylene sutures, and then the sutures were taken out of the left atrium to control the chordal tension. The condition under which the artificial chordae were released was defined as "redundant." The chordal tension of 15 g of weight was defined as "taut," whereas the tension for 2-mm chordal shortening after "taut" was defined as "tight." After the dogs were weaned from cardiopulmonary bypass, hemodynamic and 3-dimensional data were acquired under the condition of "redundant," and then "taut," "tight," and "redundant."
Results: End-systolic elastance increased from 1.81 ± 0.24 mm Hg/mL to 2.69 ± 0.89 mm Hg/mL (P = .015) between "redundant" and "taut," and this was maintained between "taut" and "tight." However, preload recruitable stroke work increased from 41.3 ± 12.0 mm Hg to 58.1 ± 19.7 mm Hg (P = .005) between "redundant" and "taut," and was reduced to 51.7 ± 22.9 mm Hg (P = .037) between "taut" and "tight."
Conclusion: "Translocation" of the secondary chordae tendineae after chordal cutting improved left ventricular systolic function compared with simple chordal cutting.
| Introduction |
|---|
|
|
|---|
|
The secondary CT are attached to the AL on the ventricular side, and the anatomic direction runs toward the mid-anterior MA (Figure 2). Thus, the force direction should travel from the PM tip through the AL to the mid-anterior MA. By creating the artificial CT after chordal cutting, we developed a novel surgical solution in which the force between the MA and the PM was preserved, without causing any distortion in the AL geometry, by connecting the mid-anterior MA and the PM tips; the direction of the force was anatomically identical or similar to the natural mitral valvularventricular continuity (Figures 1 and 2). We named it chordal "translocation" because the distal ends of the secondary CT are detached from the AL and extended to the mid-anterior MA (Figure 1).
|
| Materials and Methods |
|---|
|
|
|---|
Surgical Preparation
Six mongrel dogs (17.5 ± 0.8 kg) were premedicated with ketamine hydrochloride (20 mg/kg intramuscularly), and general anesthesia was induced with sodium pentobarbital (15 mg/kg intravenously). Anesthesia was maintained after endotracheal intubation with oxygen and isoflurane (0.5%-1.5%). Dogs were placed in the right lateral decubitus position, and a left anterior thoracotomy was made through the fifth intercostal space. The pericardium was opened, and the heart was suspended in a cradle. Two crystal markers 2.3 mm in diameter (Sonometrics Corp, London, Ontario, Canada) were inserted in the subendocardium, defining the anterior and inferior walls at the equator, and a single crystal marker was inserted at the LV apex. The anterior point was identified as the proximal junction between the left anterior descending branch and the first diagonal branch. The inferior point was the left side of the posterior descending branch at the same equator of the anterior point. The crystal markers were placed on the obturator of a plastic sheath and inserted through a stab wound on the epicardial surface. Then the obturator to lead the crystals was advanced into the subendocardium and withdrawn, leaving the crystals in place. A rubber catheter, used as an inferior vena cava occluder, was placed around the inferior vena cava to provide transient preload reduction. During cardiopulmonary bypass (CPB), after cardioplegic arrest and through a left atriotomy, 4 crystal markers were sutured around the circumference of the MA at mid-anterior, mid-posterior, anterior commissure, and posterior commissure in the LA. The 2 largest CT from each PM inserted into the AL were identified as the secondary CT (Figure 2). They were carefully resected, and 2 crystal markers were sutured on each PM tip near their origin. For the artificial CT, the U stay of 4-0 polypropylene was placed at the origin of the secondary CT of the anterior and posterior PMs. Then, 2 plastic catheters 0.95 mm in diameter were inserted through the mid-anterior MA from the LA to the LV, and 2 rubber catheters 1.25 mm in diameter were connected to the plastic catheters. These were fixed with a 5-0 silk suture on the annulus. The distance between each catheter was 3 mm, and the catheter length was 10 mm. Polypropylene sutures from the PMs were inserted through the plastic and rubber catheters from the LV to smoothly move the polypropylene sutures (Figures 2 and 3).
The LA was subsequently closed, and polypropylene sutures as the artificial CT with the rubber catheters were taken out from the LA to control the chordal tension. The animals were weaned from CPB, and epicardial color Doppler echocardiography confirmed normal leaflet motion and valvular competence. A micromanometer-tipped catheter (Millar MPC-500, Millar Instruments, Inc, Houston, Tex), used to monitor LV pressure, and a 6F conductance catheter (2S-RH6DA-116, Alpha Medical Instruments, Inc, Mission Viejo, Calif), used to monitor the LV volume, were inserted through the LV apex.
|
We controlled the chordal tension of the artificial CT during the procedure in the following manner. First, we set the chordal tension of the artificial CT free, and the condition was described as "redundant 1." Then, the artificial CT were pulled from the anterior and posterior PM tips and fixed with the rubber catheters so that the chordal tension of the artificial CT was 15 g in end diastole. Polypropylene sutures were pulled through a pulley by gravity. This condition was described as "taut." After that, the artificial CT were pulled another 2 mm exactly at the clamp position and fixed. This condition was described as "tight." Finally, the artificial CT were removed. This condition was described as "redundant 2." Data acquisition of hemodynamics and 3-dimensional markers were performed before and after occluding the inferior vena cava with occluder.
Data Acquisition
Cardiac hemodynamics
Hemodynamic parameters consisted of LV end-systolic pressure, LV end-diastolic pressure, maximum positive rate of change of the LV pressure, minimum negative rate of change of the LV pressure, tau, stroke volume, and cardiac output. The heart rate was set to 100 beats/min by atrial pacing. Finally, end-systolic elastance (Ees) and preload recruitable stroke work (PRSW) were calculated to assess global LV systolic function. Ees and PRSW were calculated for 8 consecutive beats along the mid-slope of the end-systolic pressurevolume relation curve.
Sonomicrometry crystals
Four crystal markers (4-7) were arrayed around the MA, 3 crystal markers (1-3) were placed on the anterior and inferior walls and the apex, and 2 crystal markers (8 and 9) were positioned on the tips of the anterior and posterior PMs (Figure 1). The distance between each crystal marker was measured with SonoSOFT software (Sonometrics Corp). The length of the artificial CT was confirmed by measuring the distance between the mid-anterior MA (6) and the anterior and posterior PMs (8 and 9).
The chordal tension of the artificial CT was controlled with polypropylene sutures through the LA from the outside, and the distance-reduction (millimeters) was defined as the reduction of the distance at end diastole between the mid-anterior MA and each PM tip during the conditions of "taut," "tight," and "redundant 2," compared with that during the condition of "redundant 1" (control). The distance-reductions were calculated for anterior and posterior sutures, respectively.
The dimension of the LV long axis was determined as the average of the distances between 4 crystal markers around the MA and the crystal marker at the apex. In addition, the dimension of the LV short axis was measured as the distance between the crystal markers in the anterior and inferior walls at the equator (2 and 3); this dimension in end diastole was defined as the LV diastolic dimension. Fractional shortening (FS) was calculated from the end-diastolic and end-systolic dimensions.
Statistical Analysis
All statistical analyses were performed with StatView software, version 5.0 (SAS Institute, Cary, NC). The data were expressed as mean ± standard deviation, and comparisons between each condition were performed with the paired t test.
| Results |
|---|
|
|
|---|
Hemodynamics
Hemodynamic data for the 4 conditions, "redundant 1," "taut," "tight," and "redundant 2," are listed in Table 1. No significant differences in the LV end-systolic pressure, LV end-diastolic pressure, end-diastolic volume, LV dP/dt, LV-dP/dt, or tau were observed between the 4 conditions.
|
End-systolic Elastance and Preload Recruitable Stroke Work
Ees increased from 1.81 ± 0.24 mm Hg/mL to 2.69 ± 0.89 mm Hg/mL (P = .015) between "redundant 1" and "taut," and this was maintained between "taut" and "tight." Ees significantly diminished to almost the same level during "redundant 1" between "tight" and "redundant 2" (Table 1). However, PRSW increased from 41.3 ± 12.0 mm Hg to 58.1 ± 19.7 mm Hg between "redundant 1" and "taut" (Table 1), and was reduced to 51.7 ± 22.9 mm Hg (P = .037) between "taut" and "tight."
Sonomicrometry Crystals
The distance-reductions during each condition ("taut," "tight," and "redundant 2") are shown in Table 2.
|
|
| Discussion |
|---|
|
|
|---|
The importance of continuity between the MA and the PMs in LV systolic function is recognized as valvularventricular interactions. The validity of this concept has been shown in studies in which preservation of the CT during MVR resulted in better LV function and prognosis.26-28
Although the importance of CT preservation in improving LV contractility after valve replacement has become widely accepted, the roles of primary or secondary CT have only recently been studied in detail.23
For example, LV function deteriorated (eg, PRSW and Ees) after cutting the secondary CT in a study on sheep.24,29
Komeda30
reported that mitral chordal reconstruction with the oblique technique was effective for LV function during MVR. However, Komedas aim was to improve LV function after all CT were resected during MVR, and this technique was not a reconstruction following the anatomic direction of the anterior secondary CT. Our study showed that the secondary CT were physiologically important for LV function by demonstrating that "translocation" of the anterior secondary CT in a native direction improved LV function after chordal cutting while preserving the primary CT.
In the acute study, experimental results are influenced by the condition of the animal model. However, in this study we developed a model that is relatively free from such problems. First, we confirmed a stable baseline condition of the heart by measuring the "redundant" condition (ie, condition after chordal cutting). Then, we studied the additive effect of the chordal "translocation" by comparing with the baseline (ie, redundant condition). Finally, we studied the effect caused by removal of "translocation." To note, LV function was almost similar in the first and the last serial measurements.
The level of anesthesia was unchanged, and drugs that influence LV function were not administered. We therefore believe that the animal model precisely detected the influence of chordal tension.
Komeda and colleagues31
reported in a canine model that the best traction force (after all CT abscission) applied to the PM was 10 g and that the traction force of 30 g or higher interfered with LV systolic and diastolic function. Therefore, we used a 15-g weight as the "adequate" traction force. The dimensions between the mid-anterior MA and the PM tips after chordal cutting were reduced by the traction. This weight was necessary for the artificial CT to function properly within the appropriate force range of traction.
The results of this study are 2-fold. First, the load-independent parameters of systolic LV function, such as Ees and PRSW, improved after chordal "translocation." This suggests that secondary CT play an important role in LV systolic function. It is known that Ees reflects pure LV systolic function, whereas PRSW is more or less influenced by diastolic function. In this study, PRSW decreased from "taut" to "tight" with a significant difference. Therefore, a "tight" condition may have possibly disturbed LV diastolic function, although either tau or minimum negative rate of change of the LV pressure did not change between "taut" and "tight." Second, the dimension of the LV long axis was not influenced by the "taut" condition but was reduced by the "tight" condition. Third, the LV long-axis dimension on the anterior MA (1-6) and the posterior commissure (1-5) sides were significantly reduced by the "tight" condition. Although the distance-reduction of the anterior PM side was longer than that of the posterior side, the dimension between the anterior commissure and the apex did not change. However, the dimension between the posterior commissure and the apex was significantly reduced. We think that the apex approached the annulus and shifted toward the posterior commissure side when chordal tension was applied because the ventricular septum was present on the anterior commissure side. Appropriate and effective traction did not affect the geometry of the LV. Excessive traction of the PM such that the apex was shifted impaired the LV function. In this study, inotropic agents were not used during CPB weaning. If LV function was strengthened by inotropic agents, the Ees and PRSW values would become too great to observe any effect induced by chordal "translocation."
| Study Limitations |
|---|
|
|
|---|
First, the data were obtained from an acute, open-chest, and open-pericardium setting in normal canine hearts immediately after a complex surgical procedure and cardiac arrest. Therefore, caution must be exercised when extrapolating these findings to human beings with chronic heart disease. Only acute changes in our study were measured. Postoperative LV remodeling cannot be studied in an acute model, and such remodeling may likely have important effects on LV function. For more clinically relevant investigation, it is necessary to study LV geometry and function after chordal "translocation" in a model of chronic heart failure with MR.
Second, because of the reflection of the cables of the sonomicrometry crystal markers and tubes on the annulus in the LA, the MR area was not traced during the serial measurements of "redundant 1," "taut," "tight," and "redundant 2" conditions. However, the color Doppler echocardiography demonstrated absent or trivial (1+) MR after cutting the secondary CT in all animals.
| Conclusions |
|---|
|
|
|---|
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
S. Masuyama, A. Marui, T. Shimamoto, and M. Komeda Reversed L-shaped deformity of the anterior mitral leaflet and its reparative technique. J. Thorac. Cardiovasc. Surg., December 1, 2008; 136(6): 1599 - 1601. [Full Text] [PDF] |
||||
![]() |
S. Masuyama, A. Marui, T. Shimamoto, M. Nonaka, M. Tsukiji, N. Watanabe, T. Ikeda, K. Yoshida, and M. Komeda Chordal translocation for ischemic mitral regurgitation may ameliorate tethering of the posterior and anterior mitral leaflets. J. Thorac. Cardiovasc. Surg., October 1, 2008; 136(4): 868 - 875. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Nonaka, A. Marui, M. Fukuoka, T. Shimamoto, S. Masuyama, T. Ikeda, and M. Komeda Differences in mitral valve-left ventricle dimensions between a beating heart and during saline injection test Eur J Cardiothorac Surg, October 1, 2008; 34(4): 755 - 759. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Komeda and T. Shimamoto Cutting secondary chordae and placing dual taut stitches between the anterior mitral fibrous annulus and the heads of each papillary muscle to treat ischemic mitral regurgitation without deteriorating left ventricular function J. Thorac. Cardiovasc. Surg., January 1, 2008; 135(1): 226 - 227. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |