JTCS KCI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Gavin J. Murphy
Gianni D. Angelini
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Murphy, G. J.
Right arrow Articles by Angelini, G. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Murphy, G. J.
Right arrow Articles by Angelini, G. D.

J Thorac Cardiovasc Surg 2007;134:504-505
© 2007 The American Association for Thoracic Surgery


Brief Communication

A randomized trial of an external Dacron sheath for the prevention of vein graft disease: The Extent study

Gavin J. Murphy, MD, FRCS*, Andrew C. Newby, BA, PhD1, Jamie Y. Jeremy, PhD, Andreas Baumbach, MD, FRCP, Gianni D. Angelini, MD, FRCS1

Bristol Heart Institute, Bristol Royal Infirmary, Bristol, United Kingdom.

* Address for reprints: Mr GJ Murphy, Bristol Heart Institute, Bristol Royal Infirmary, Marlborough Street, Bristol BS6 5SJ, United Kingdom. Telephone: 0044 117928 3145, Fax: 0044 1179299737. (Email: Gavin.Murphy{at}bristol.ac.uk).

The success of coronary artery bypass grafting is limited by poor long-term graft patency. Despite the superior patency of arterial grafts, saphenous vein remains the most commonly used conduit for coronary artery bypass because of its predictable handling qualities and ready availability.1Go Over 40% of vein grafts are thrombosed at 10 years postoperatively,2Go largely as a consequence of vein graft disease that is characterized by neointima formation, atherosclerosis, and plaque rupture. Graft failure results in recurrent angina, myocardial infarction, or death and leads to repeat revascularization procedures with their associated morbidity and costs. To date, with the exception of aggressive lipid lowering, no therapy has been shown to improve long-term vein graft patency in clinical studies. In porcine saphenous vein to carotid artery interposition graft, placement of a loose-fitting external macroporous Dacron sheath inhibits vein graft disease in the long term.3,4Go The aim of this phase I randomized pilot study was to evaluate the effects of placement of the external Dacron stent, or Extent (Vascutek Ltd, Inchinnan, Scotland), on vein graft disease in patients undergoing elective coronary artery bypass grafting.

Materials and Methods

Between March and September 2005, 20 patients undergoing isolated on-pump coronary artery bypass grafting, and who had given informed consent, were randomized to have an Extent placed to either a right coronary system graft or left coronary system target graft. The Extent is an incomplete tube of knitted polyester reinforced with polytetrafluoroethylene ribs at approximately 1-cm intervals to maintain rigidity (Figure 1). The edges of the incomplete tube form a flange. The stent was so designed to maintain the circular cross section of the graft and to facilitate placement after completion of both distal and proximal anastomoses, with the flange preventing migration or kinking of the vein graft through the side of the graft. Two graft sizes were used, 8 mm and 6 mm. Graft sizing was intended to be nonrestrictive with up to 1-mm clearance around the circumference of the vein graft. Patients were eligible if they were to receive a reversed long saphenous vein graft to both the right and left coronary systems in addition to a pedicled left internal thoracic artery graft to the left anterior descending coronary artery. The Extent was placed on the vein graft after the proximal and distal anastomoses had been completed and protamine administered. Where possible, the proximal and distal ends of the graft were sutured to the epicardium distally and to the aortic adventitia to prevent migration; however, in 9 of the grafts, postdeployment trimming of the proximal or distal anastomoses to optimize the graft lie prevented this. The flange was allowed to lie as appeared optimal to the graft curvature around the heart. The study had received local ethical review board approval, and all patients gave informed consent to the procedure. The primary end point of the study was a 20% reduction of wall thickness as assessed by intravascular ultrasound at 6 months after surgery relative to the untreated contralateral vein graft.


Figure 1
View larger version (93K):
[in this window]
[in a new window]

 
Figure 1. Extent, a macroporous Dacron sheath reinforced with polytetrafluoroethylene ribs. The flange permits placement after completion of both anastomoses.

 
Results

Key demographic, operative, and postoperative data are listed in Table 1. One patient randomized to a left-sided Extent had the stent placed on a graft to the posterior descending, inasmuch as the left-sided target was heavily calcified. Two patients refused to attend for follow-up and 1 subsequently reported an allergic reaction to iodinated contrast. At follow-up angiography (9 conventional, 8 computed tomographic) all 17 Extent grafts were thrombosed. All left internal thoracic artery and non-Extent vein grafts were patent.


View this table:
[in this window]
[in a new window]

 
TABLE 1 Extent study demographic, operative, and outcome data
 
Discussion

The most likely explanation for the universal thrombosis of Extent vein grafts in this phase 1 study is that stent rigidity, oversizing, or the incomplete tube design resulted in grafts kinking, either at the anastomoses or within the middle part of the graft. This could have occurred as a consequence of stent or graft movement on chest closure or patient repositioning or at some later time. The potential for this to occur was not foreseen. Preclinical studies had been performed in the end to end or end to side porcine carotid artery interposition model where the vessels are shorter and the potential for graft movement and kinking is less, although the degree of graft oversizing was similar.

Despite the poor results of the Extent study, the dramatic and sustained effectiveness of external sheaths in experimental studies suggests that continued research is warranted. One alternative is a nonrestrictive, flexible, biodegradeable, macroporous polyglactin (Vicryl; Ethicon, Inc, Somerville, NJ) external sheath. These features overcome many of the limitations of the rigid Dacron stent and have also demonstrated long-term inhibition of vein graft disease in the porcine model.5Go

Footnotes

Funded by the British Heart Foundation.

1 Andrew Newby and Gianni Angelini are employees of the University of Bristol, which holds a patent on the concept of the external vascular stent. Back

References

  1. The Society of Cardiothoracic Surgeons of Great Britain and Ireland National Adult Cardiac Surgical Database Report 2003. Dendrite Clinical Systems; Oxforshire [UK].
  2. Goldman S, Zadina K, Moritz T, Ovitt Sethi TG, Copeland JG, et al. VA Cooperative Study Group #207/297/364 Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery results from a Department of Veterans Affairs Cooperative Study. J Am Coll Cardiol 2004;44:2149-2156.[Abstract/Free Full Text]
  3. Mehta D, George SJ, Jeremy JY, Izzat MB, Southgate KM, Bryan AJ, et al. External stenting reduces long-term medial and neointimal thickening and platelet derived growth factor expression in a pig model of arteriovenous bypass grafting. Nat Med 1998;4:235-239.[Medline]
  4. Angelini GD, Lloyd C, Bush R, Johnson J, Newby AC. An external, oversized, porous polyester stent reduces vein graft neointima formation, cholesterol concentration, and vascular cell adhesion molecule 1 expression in cholesterol-fed pigs. J Thorac Cardiovasc Surg 2002;124:950-956.[Abstract/Free Full Text]
  5. Vijayan V, Shukla N, Johnson JL, Gadsdon P, Angelini GD, Smith FC, et al. Long-term reduction of medial and intimal thickening in porcine saphenous vein grafts with a polyglactin biodegradable external sheath. J Vasc Surg 2004;40:1011-1019.[Medline]



This article has been cited by other articles:


Home page
Circ Cardiovasc IntervHome page
T. Rajathurai, S. I. Rizvi, H. Lin, G. D. Angelini, A. C. Newby, and G. J. Murphy
Periadventitial Rapamycin-Eluting Microbeads Promote Vein Graft Disease in Long-Term Pig Vein-Into-Artery Interposition Grafts
Circ Cardiovasc Interv, April 1, 2010; 3(2): 157 - 165.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Gavin J. Murphy
Gianni D. Angelini
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Murphy, G. J.
Right arrow Articles by Angelini, G. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Murphy, G. J.
Right arrow Articles by Angelini, G. D.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS