|
|
||||||||
J Thorac Cardiovasc Surg 2007;134:960-966
© 2007 The American Association for Thoracic Surgery
Surgery for Congenital Heart Disease |
a Department of Pediatrics, University of Chicago Comer Childrens Hospital, Pritzker School of Medicine, Chicago, Ill
b Department of Cardiac Surgery, Boston Childrens Hospital and Harvard Medical School, Boston, Mass.
Received for publication October 10, 2006; revisions received May 20, 2007; accepted for publication June 8, 2007. * Address for reprints: Ziyad M. Hijazi, MD, MPH, Director, Rush Center for Congenital and Structural Heart Disease, Rush University Medical Center, 1635 West Congress Parkway, Jones 770, Chicago, IL 60612. (Email: zhijazi{at}rush.edu).
| Abstract |
|---|
|
|
|---|
Methods: Between July 1999 and September 2006, atrial septal defect closure with the Amplatzer septal occluder was attempted in 15 infants at our institution. The patients ranged in age from 0.5 to 11.9 months (mean ± standard deviation; 8.2 ± 3.7 months) in the percutaneous group and from 2.2 to 3.4 months (2.9 ± 0.6 months) in the peratrial group. Their weights ranged from 3.8 to 8.3 kg (5.5 ± 1.7 kg) and from 3.0 to 4.0 kg (3.4 ± 0.6 kg) in each group, respectively. The indications for atrial septal defect closure were failure to thrive, significant chamber enlargement, hemodynamically significant shunts, and prehepatic transplantation. The size of the defect as measured by intracardiac echocardiography (n = 3) or transesophageal echocardiography (n = 12) ranged from 2.0 to 16 mm (8.0 ± 4.4 mm).
Results: The pulmonary/systemic flow ratio ranged from 1.0 to 9.0 (2.8 ± 2.0).The device was successfully placed in 14 of 15 infants. The size of the Amplatzer septal occluder device implanted ranged from 4 to 20 mm (10.1 ± 4.3 mm). It was percutaneously deployed in 11 of 14 patients and by the hybrid or peratrial approach (open chest off-pump) in 3 of 14 infants. In infants who had a successful attempt (n = 14), the complete closure rates at 24 hours and 1 year were 86% and 100%, respectively. In 3 of 15 infants, minor complications occurred: transient arrhythmias (n = 2) and blood transfusion (n = 1). One patient had a major complication (vascular intimal injury with thrombosis of the inferior vena cava). One patient with Down syndrome died 6 weeks later of progressive pulmonary hypertension. The follow-up time ranged from 0.6 to 6.9 years (3.2 ± 1.9 years). At follow-up, clinical development and growth improved in all children with failure to thrive, and all ventilator-dependent children could be weaned shortly after closure of the atrial septal defect.
Conclusion: Device closure of atrial septal defects is an effective and fairly safe alternative to surgery in infants. Hybrid or peratrial closure is also an alternative to percutaneous closure in the very small infant.
| Introduction |
|---|
|
|
|---|
|
Secundum atrial septal defect (ASD) is a common congenital heart disease and accounts for approximately 6% to 10% of all congenital cardiac defects.1
Since 1976, when King and associates2
attempted the first transcatheter closure of a secundum ASD in humans, device closure has evolved significantly. The Amplatzer septal occluder (ASO) (AGA Medical Corp, Golden Valley, Minn) has become the most commonly used device. Previous reports have shown that it is easy to use and has a high success rate.3-6
The alleged advantages of percutaneous closure over surgical closure as shown by some studies in older children and adults include avoidance of cardiopulmonary bypass, decreased complication rates, shorter hospital stays,7,8
and greater cost-effectiveness.9
Although device closure is now a widely acceptable alternative to surgery in most patients with secundum ASD, it is still considered technically challenging in infants, with little known about its safety and feasibility in those less than 1 year of age. Previous studies involving device closure of secundum ASDs have included predominantly adults and older children,7,10,11
with no reports involving a large series of very young infants.
The aim of this study was to evaluate the feasibility, efficacy, and safety of device closure of secundum ASDs in infants using either the percutaneous or the hybrid (peratrial) approach.
| Materials and Methods |
|---|
|
|
|---|
Patient Population
Between July 1999 and September 2006, 15 infants (9 boys and 6 girls) underwent an attempt at closure of their secundum ASDs with the ASO by either the percutaneous or the hybrid technique. Routine informed consent was initially obtained from the parents before any kind of intervention and approval for chart review was obtained by the institutional review board. The infants ranged in age from 0.5 to 11.9 months (mean ± standard deviation, 8.2 ± 3.7 months) in the percutaneous group and from 2.2 to 3.4 months (2.9 ± 0.6 months) in the peratrial group. The weights ranged from 3.8 to 8.3 kg (6.0 ± 1.4 kg) and from 3.0 to 4.0 kg (3.4 ± 0.6 kg) in each group, respectively (Table 1). The indications for ASD closure included failure to thrive with significant chamber enlargement and/or hemodynamically significant shunts despite medical therapy in 11 patients. In 2 patients who were undergoing hepatic transplantation, device closure of a patent foramen ovale was performed to prevent any paradoxical emboli during inferior vena cava unclamping. Two other patients had significant chronic lung disease secondary to prematurity and were ventilator-dependent.
|
The peratrial approach was used in 3 patients (patients 13, 14, and 15) owing to the size of the infant (<3.5 kg) in 2 cases and because of simultaneous perventricular ventricular septal defect (VSD) closure in 1 case (Figure 1). This approach involved a minimal lower sternotomy that was performed after full evaluation of the ASD by TEE. The right atrial wall was then punctured with an 18-gauge needle through which a 0.035-inch wire was passed to the left atrium. The dilator and the introducing sheath were placed in the mid left atrium. Injecting agitated saline bubbles into the left atrium confirmed the position of the sheath. The ASO was then loaded into the sheath and the left disc was deployed first, followed by the right disc. The position of the device was then confirmed by TEE before the device was released.
|
| Results |
|---|
|
|
|---|
Additional interventional procedures were performed in 4 of 15 patients during the same session (patients 2, 8, 11, and 15). Those included patent ductus arteriosus coil occlusion (n = 1), aortic balloon angioplasty for recoarctation (n = 1), and muscular VSD closure (n = 2). In addition, 1 patient (patient 6 in Table I) had an electrophysiologic study subsequent to the intervention because of a history of atrioventricular node re-entrant tachycardia. Cardiopulmonary bypass was not needed in any of the peratrial cases.
Table 1 also lists the adverse events related to the procedure or to the device. Minor complications were encountered in 3 patients. These included transient arrhythmias in 2 patients and blood loss during access requiring blood transfusion in 1 patient. One patient had a major complication (vascular intimal injury in the right femoral vein). This resulted in swelling of the right leg owing to thrombus formation in the femoral and iliac veins with extension into the inferior vena cava. This patient required heparin therapy for a few days followed by warfarin for 6 months. The swelling has disappeared; however, the inferior vena cava remains thrombosed. One patient who had Down syndrome died 6 weeks after the procedure of progressive pulmonary hypertension and right ventricular failure. All other 13 patients did well. To date, there have been no episodes of endocarditis, thromboembolism, device disruption or erosion, valve regurgitation, or permanent rhythm disturbances.
| Follow-up and Clinical Condition |
|---|
|
|
|---|
-month-old boy who had heart failure owing to a significant left-to-right shunt via the ASD. During the cardiac catheterization, the pulmonary artery pressure was elevated at near systemic levels with a pulmonary/systemic flow ratio of 2.6 and a pulmonary vascular resistance of 5.9 units in room air. We believed that closure of the ASD was indicated. The defect was closed completely with an 8-mm device. However, the patient continued to have right ventricular enlargement and the pulmonary artery pressure continued to increase as evaluated by the tricuspid regurgitation jet. Six weeks after closure, he died of severe heart failure. Autopsy revealed complete closure of the defect and that the device was far from vital structures (pulmonary veins, superior vena cava, and the atrioventricular valves). Histopathologic examination of the lungs revealed severe pulmonary vascular obstructive disease, consistent with Heath-Edwards grade III-IV. In addition, we evaluated the growth of the atrial septum in some of our patients as they grew (Figure 2). The ratio of the device to the atrial septum was calculated at the time of the procedure and then at 1-year follow-up with the 4-chamber apical view by transthoracic echocardiography. As is shown in Figure 2, there is a trend for this ratio to decrease as these infants grow older. Thus, although the device is significantly large compared with the atrial septum at the time of closure, the septum grows significantly and the device size becomes less concerning.
|
| Discussion |
|---|
|
|
|---|
Few clinical studies in the literature have addressed the problem of symptomatic secundum ASD in infants. Most are publications reporting on the outcome of surgical closure in small series of patients.15,21-24
A study by Parvathy and associates25
evaluated the outcomes of surgical closure of ASD in 18 children under 2 years of age. It showed encouraging results good enough that the group recommended early closure of ASD in symptomatic infants. In that study, 4 of 18 infants had pulmonary complications. Lammers and coworkers26
reported on the surgical closure of secundum ASD in 24 symptomatic infants less than 1 year of age and showed significant improvement in growth and development on follow-up of these patients, except for 1 infant with Down syndrome who died later of severe pulmonary hypertension. More recently, a study by Vogel and colleagues27
reported the results of percutaneous closure of secundum ASD in 12 symptomatic patients less than 2 years of age with a mean age of 1.5 ± 0.4 (range 0.8-1.8 years) using the ASO device. Only 5 of 12 patients in that study weighed less than 10 kg. Although that study showed that the procedure could be successfully achieved, the success rates were lower than in older patients and 2 patients needed the device to be removed surgically due to continued large residual shunt.
In our series, device closure was successful in 14 of 15 patients. In 1 patient in whom TEE showed possible appropriate rims for device closure, ICE documented deficient inferoposterior rims; device closure was unsuccessful despite multiple attempts owing to prolapse of the device into the right atrium. The patient underwent surgical closure with no complications. In those who had a successful attempt, closure rates were very encouraging: 86% at 24 hours and 100% at 1-year follow-up. This result compares favorably with closure rates of 98.5% at 1-year follow-up reported in older children and adults.7
In 1 patient, the device prolapsed through the defect and a larger sheath was needed to recapture the device and to implant a larger size occluder. Only 1 patient had a technical difficulty, in which the device could not be seated well owing to a deficient inferior rim; the device was recaptured and the patient was sent for surgical closure at a later date.
In our patients, 5F to 8F sheaths were used to deliver the ASO devices. In 2 patients, a 5F sheath was used and in 5 others an 8F sheath was required. Only 1 patient, in whom an 8F sheath was used to deliver a 13-mm device (delivered with an 8F Judkins right coronary guide catheter to prevent prolapse of the left atrial disc into the right atrium), had a vascular complication with injury to the intima of the inferior vena cava (see above).
In the percutaneous cases, the ASO was delivered through femoral access in 10 instances. In 1 patient (patient 8) in whom both femoral veins were thrombosed, the transhepatic approach was used to deliver a 6-mm ASO device with no complications.
In most of our patients, ASD closure was done routinely under TEE guidance. ICE was used in 3 patients with no complications (patients 10, 11, and 12). It has been shown in previous reports that ICE provided better imaging for secundum ASD and the left atrium and that its use as a guiding imaging tool for device closure resulted in no significant adverse events in patients weighing less than 15 kg.4
In the patient in whom device closure was unsuccessful (patient 12), we believe ICE was superior to TEE in delineating the rims of the defect, especially the inferoposterior rims, to guide device closure.
The peratrial (hybrid) technique was used in 3 infants in our series. The advantage of this approach compared with the classic surgical approach is avoidance of cardiopulmonary bypass that could be associated with significant morbidity in premature patients with severe bronchopulmonary dysplasia (2 patients in this series). In addition, unlike the percutaneous technique, the peratrial approach provides some advantages: it preserves the femoral vessels and provides a perpendicular angle to the atrial septum as opposed to the sharp angle through the IVC as in the transcatheter closure, which may result in prolapse of the left atrial disc into the right atrium. The hybrid approach rather than the percutaneous approach was used in these cases owing to the size of the infants (<3.5 kg) in 2 patients and because of the simultaneous perventricular muscular VSD closure in 1 patient. All 3 patients had complete closure immediately after device implantation and at 1-year follow-up.
This series demonstrates encouraging results with an acceptable incidence of complications related to the procedure or device implantation. Only 1 patient died in our series, and his death was not procedure or device related. That patient clearly met the criteria to close the defect; however, perhaps a fenestrated device would have been a better consideration.
Minor complications occurred in 3 of 14 (21.4%) patients in our study, 2 of which were related to transient arrhythmias. This is higher than the rate of minor morbidity of 17.8% reported with surgical closure and of 7.2% reported with device closure in older children and adults.3
One of these patients who had arrhythmia, however, was known to have atrioventricular node re-entrant tachycardia. One patient who underwent peratrial device closure (patient 13) had transient heart block during device manipulation and it resolved at the end of the procedure.
Device embolization was not encountered in our series. The risk for this complication was reported to be about 1.1%.3
We believe that more experience in using the ASO device in young infants will make this technical complication less frequent. It is important to mention, however, that the ability to retrieve the device might be more challenging in infants, especially that large sheaths would be required.
Last, as mentioned earlier, all infants thrived well after device closure and their weight was above the 10th percentile on the latest follow-up, proving that these defects were the cause for the failure to thrive.
| Study Limitation |
|---|
|
|
|---|
| Conclusions |
|---|
|
|
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
S. Talwar, M. Upadhyay, S. K. Choudhary, S. S. Kothari, R. H. Anderson, and B. Airan Interatrial Communication With Unusual Caval Venous Anomalies World Journal for Pediatric and Congenital Heart Surgery, October 1, 2010; 1(3): 400 - 403. [Abstract] [Full Text] [PDF] |
||||
![]() |
Q. Chen, L.-W. Chen, H. Cao, G.-C. Zhang, D.-Z. Chen, and H. Zhang Intraoperative Device Closure of Atrial Septal Defect in Infants Ann. Thorac. Surg., April 1, 2010; 89(4): 1250 - 1254. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. M. Hijazi and S. M. Awad Pediatric Cardiac Interventions J. Am. Coll. Cardiol. Intv., December 1, 2008; 1(6): 603 - 611. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |