Goro Matsumiya
Masaaki Kato
Hiroshi Takano
Yoshiki Sawa
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Shimamura, K.
Right arrow Articles by Sawa, Y.
PubMed
Right arrow Articles by Shimamura, K.
Right arrow Articles by Sawa, Y.
Related Collections
Right arrow Great vessels
Right arrowRelated Article

J Thorac Cardiovasc Surg 2008;135:1261-1269
© 2008 The American Association for Thoracic Surgery


Surgery for Acquired Cardiovascular Disease

Long-term results of the open stent-grafting technique for extended aortic arch disease

Kazuo Shimamura, MDa, Toru Kuratani, MD, PhDa, Goro Matsumiya, MD, PhDa, Masaaki Kato, MD, PhDd, Yukitoshi Shirakawa, MD, PhDa, Hiroshi Takano, MD, PhDc, Noriyuki Ohta, MD, PhDb, Yoshiki Sawa, MD, PhDa,*

a Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
b Department of Anesthesiology, Osaka University Graduate School of Medicine, Osaka, Japan
c Department of Cardiovascular Surgery, Osaka General Medical Center, Osaka, Japan
d Department of Cardiovascular Surgery, Morinomiya Hospital, Osaka, Japan

Received for publication May 3, 2007; revisions received September 27, 2007; accepted for publication October 31, 2007.

* Address for reprints: Yoshiki Sawa, MD, PhD, Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan. (Email: sawa{at}surg1.med.osaka-u.ac.jp).


    Abstract
 Top
 Abstract
 Introduction
 Patients and Methods
 Results
 Discussion
 Conclusion
 References
 
Objective: This report elucidates the long-term safety and effectiveness of extended aortic arch replacement with an open stent-grafting technique from our 12 years of experience.

Methods: From 1994 to 2004, 126 patients (mean age 67.8 years) with different pathologic conditions of the aortic arch with extension to the descending aorta (57 dissections [acute/chronic = 31/26] and 69 aneurysms) were operated on with an open stent-grafting technique. During deep hypothermic circulatory arrest with selective cerebral perfusion, the stent graft was delivered through the transected proximal aortic arch, and arch replacement with a 4-branched prosthesis was performed.

Results: Operative mortality within 30 days was 3.2%. Perioperative morbidity included 7 (5.6%) strokes and 8 (6.3%) spinal injuries (paraplegia in 3, transient paraparesis in 5). Sixty-three percent of the patients were extubated within 24 hours. In long-term follow-up (mean 60.4 ± 36.5 months, maximum 153 months), survival was 81.1%, 63.3%, and 53.7% at 1, 5, and 8 years. Five (3.9%) late endoleaks were observed but treated with successful additional endovascular repair. Freedom from endoleaks was 98.0%, 91.1%, and 91.1% for 1, 5, and 8 years, respectively.

Conclusion: Long-term observation showed safety and good durability of the open stent-grafting technique for aortic arch disease. This technique could be an attractive treatment option for aortic arch aneurysm with distal extension and aortic dissection requiring aortic arch replacement.



Abbreviations and Acronyms CSFD = cerebrospinal fluid drainage; CT = computed tomography; TEVAR = thoracic endovascular aortic repair; Th = thoracic (vertebra)



    Introduction
 Top
 Abstract
 Introduction
 Patients and Methods
 Results
 Discussion
 Conclusion
 References
 
Direct surgical approach to pathologic conditions of the aortic arch has been a time-tested, established procedure with satisfactory results and durability. Median sternotomy is the preferred and most advantageous approach. However, performing anastomosis and hemostasis at the deep portion beyond the left subclavian artery is often associated with difficulties and also could induce recurrent laryngeal nerve injury. Moreover, when the distal end of the disease extends to the descending aorta, surgeons have to select extensive exposure of the distal aortic arch or left thoracotomy, which could raise the risk of respiratory complications.

Several approaches such as the clamshell incision,1Go median sternotomy with left thoracotomy,2Go and 2-stage repair with elephant trunk3,4Go have been applied in this situation, but a less invasive procedure without left thoracotomy and with completion in a single stage is desired.

Meanwhile, as an emerging, less invasive alternative to conventional surgical repair, thoracic endovascular aortic repair (TEVAR) was brought into clinical use by Dake and his colleagues5Go and reported in 1994. Our group has also been using TEVAR since 1993 after animal experimentation,6,7Go and satisfactory early outcomes were achieved for type B aortic dissection.8Go This method yielded a less invasive alternative for high-risk patients. However, applying TEVAR to aortic arch diseases was difficult because the aortic arch could not provide an adequate proximal landing zone. To mitigate the difficulties in both the distal anastomosis in conventional arch surgery and the proximal landing zone in TEVAR for the aortic arch, our group9Go introduced the open stent-grafting technique in 1994. This technique, which subsequently has been described as frozen elephant trunk technique or stented elephant trunk in some articles,10-14Go involves conventional replacement of the ascending aorta with a 4-branched graft and stent grafting into the descending aorta through the opened aortic arch. In 2002, we15Go reported that this technique is feasible for aortic dissection to obtain clot formation and shrinkage of the false lumen by closing the entry site in the aortic arch and providing continuous compression on the false lumen.

Previous reports10-15Go described relatively small series, and it is still controversial whether this technique is safe and useful for long-term results.

The objective of this current report is to elucidate the feasibility of this technique for extended aortic arch replacement and to investigate the long-term durability and efficacy of this hybrid procedure from our 12 years of experience.


    Patients and Methods
 Top
 Abstract
 Introduction
 Patients and Methods
 Results
 Discussion
 Conclusion
 References
 
Patients
The open stent-grafting technique and the retrospective review of the records for publication were approved by the institutional review board. From February 1994 to July 2004, 126 patients having pathologic conditions of the aortic arch with extension to the descending aorta were operated on in a single center (Osaka General Medical Center, Osaka Prefectural Hospital) by an open stent-grafting technique. The selection for open stent-grafting technique was aortic arch aneurysms with extension to the descending aorta or aortic dissections that necessitated aortic arch replacement. These indications are listed as follows:

Aortic Arch/Proximal Descending Aortic Aneurysms
• Involving proximal portion of left subclavian artery and unable to be treated with TEVAR
• Extending distally to descending aorta and difficult/unable to perform distal anastomosis in median approach
• Expected tight adhesion around distal anastomosis site (eg, redo operation)

Aortic Dissection
• Type A dissection with intimal tear in transverse arch or proximal descending aorta that could not be resected by hemiarch replacement
• Type A/type B dissection with aortic arch enlargement/aneurysm
Type B dissection with intimal tear in root of left subclavian artery (unable to close with TEVAR)

Informed consent was required in each case. Mean patient age was 67.8 years (range, 35–85 years), and 14 (11.1%) patients were older than 80 years. Thirty-seven (29.3%) operations were of an emergency status. Preoperative comorbidities are shown in Go Table 1. Ten (7.9%) patients had previous graft replacement of descending or thoracoabdominal aorta, and 18 (14.3%) had a history of abdominal aortic repair. There were 3 (2.4%) patients with Marfan syndrome.


View this table:
[in this window]
[in a new window]

 
Table 1 Preoperative patients profiles
 
Fifty-seven (46.8%) patients had aortic dissection: among these patients, 29 (49.2%) had acute type A dissections involving malperfusion of organs in 10 and loss of conscious in 3. Twelve (24.4%) of the dissections were chronic type A dissections, including 5 redo cases with enlargement of patent false lumen of the aortic arch after ascending aorta replacement in the acute phase. Sixteen (30.5%) cases were type B dissections, involving 2 acute complicated cases and 14 chronic type B dissections with enlargement of the false lumen (average size 50.0 ± 7.7 mm, range 41–70 mm). Sixty-nine (53.2%) were degenerative/atherosclerotic aneurysms with 9 (13.4%) instances of rupture. The average diameter of the aneurysm was 63.6 ± 10.6 mm. All these aneurysms had distal extension to the descending aorta, which required stent graft delivery to the level of the sixth thoracic vertebra (Th6) in 21.4%, Th7 in 35.4%, and distally to Th8 in 44.2%.

Description of the Device
The stent graft was custom-made. It was composed of a Gianturco stent (William Cook Europe A/S, Bjaeverskov, Denmark) and a noncoated polyester fabric graft (WSL graft, Ube, Japan). The diameter of the polyester graft was selected with the measurement results of preoperative 3-dimensional computed tomography (CT). The diameter of the landing zone was calculated by tracing the intimal circumference, and a graft oversized by 10% to 20% was selected. These methods were described in detail in a previous study.9Go Average diameter of the stent graft was 25.9 ± 3.5 mm for dissections and 29.5 ± 3.2 mm for degenerative aneurysms. We first used the 30F sheath and pushing rod to deliver the stent graft into the descending aorta. Although this method did not fail to deploy the stent graft, inserting the rigid sheath into the descending aorta under the guidance of transesophageal echocardiography is not easy. In 2001 we developed a sheathless delivery method. The stent graft was mounted on a balloon catheter (20F silicone nephrostomy balloon catheter) and the stented portion was restrained by a silk string. After the stent graft had been inserted into the descending aorta through the transected aortic arch, withdrawal of the restraining string released the self-expandable stented part of the graft.

Surgery
The details of the operation have been described in previous reports.9,15Go Via a median sternotomy, the ascending aorta, brachiocephalic artery, and left common carotid artery were dissected. The arterial return cannula was placed in the right axillary artery and femoral artery. Cardiopulmonary bypass was initially started with right axillary perfusion. During core cooling to a 24°C bladder temperature, reconstruction of the left subclavian artery, left common carotid artery, and proximal anastomosis of the 4-branched graft was performed (Go Figure 1, A). The left subclavian artery was reconstructed in an extramediastinal fashion at the left infra subclavian space, with the graft branch passing through the second intercostal space. The proximal end of the 4-branched graft was anastomosed to the ascending aorta after cardiac arrest was achieved by crossclamping the ascending aorta and antegrade administration of cardioplegic solution. Selective cerebral perfusion via the 4-branched graft and right axillary artery was established and the perfusion to the lower body was discontinued. The aortic arch was transected at a predetermined line between the brachiocephalic artery and left common carotid artery, and the stented portion of the stent graft was inserted to the descending aorta (Figure 1, B). After deployment, the stented portion was dilated with a balloon catheter under the guidance of transesophageal echocardiography to confirm that the stent graft was fully opened and not kinked. The nonstented graft portion was sutured to the transected stump of the aortic arch, and subsequently continuous anastomosis to the 4-branched graft was made in end-to-end fashion. The debris and air were carefully flushed out from the descending aorta with femoral blood return before this anastomosis was completed. During rewarming, the brachiocephalic artery was reconstructed and the procedure was completed (Figure 1, C). When the ascending aorta was intact and replacement was unnecessary, a bifurcated graft was anastomosed to the ascending aorta instead of 4-branched graft replacement. Reconstruction of the left common carotid artery and left subclavian artery was performed in the same fashion. To prevent ischemic spinal injury, when the time of lower body circulatory arrest extended over 30 minutes, blood return to lower body was established from femoral artery with occluding the stent graft by balloon catheter.


Figure 1
View larger version (29K):
[in this window]
[in a new window]

 
Figure 1. A, reconstruction of the left subclavian artery, left common carotid artery, and proximal anastomosis of the 4-branched graft. B, The aortic arch was transected at a predetermined line between the brachiocephalic artery and left common carotid artery, and the stent graft was inserted to the descending aorta. C, The brachiocephalic artery was reconstructed and the procedure was completed

 
Spinal Protection
From January 1997, cerebrospinal fluid drainage (CSFD) was performed before the operation in elective cases with a history of aortic repair in the thoracoabdominal or abdominal aorta. CSFD was administered preoperatively in 16 (12.7%) cases. When the pathologic condition required stent graft delivery lower than the ninth thoracic vertebra, a short stent graft was delivered in the descending aorta without excluding the aneurysm, and additional endovascular grafting was performed the next day for complete exclusion (delayed exclusion technique). From 2001, to avoid spinal cord ischemia, we started to apply the delayed exclusion technique because of the following reasons:
1. Technical reason. A longer stent graft is hard to control under the guidance of transesophageal echocardiography, and there is a risk of kinking. From our experience, an easily manageable length of the stent graft is less than 15 cm, and this could reach around Th8 level.
2. Preservation of the spinal circulation. TEVAR provides excellent avoidance of spinal cord ischemia even when it covers the major intercostal artery connecting to the anterior spinal artery (Adamkiewicz artery). Delayed exclusion with additional endovascular grafting could maintain the spinal circulation, and we anticipate this technique could decrease the risk of spinal cord ischemia. Six (4.8%) patients were treated with the delayed exclusion technique.

Patient Follow-up
The follow-up with contrast CT imaging was obtained before hospital discharge, 6 months after the operation, and yearly thereafter. A follow-up CT image was available for 81.9% of patients who survived longer than 6 months. Follow-up clinical status was obtained by medical records from an outpatient clinic or by contacting surviving patients or family members and primary care physician. Follow-up was 92.6% complete, averaging 60.4 ± 36.5 months (maximal follow-up 153 month, total cumulative follow-up = 533 patient-years; 45 patient remaining at risk at 5 years).

Statistical Analysis
All data were reviewed retrospectively. Continuous variables are expressed as mean ± SD and categorical variables as percentages. Survival and freedoms from aortic arch–related death, freedom from endoleaks, freedom from aortic intervention, and freedom from major adverse events were estimated by the Kaplan–Meier method.


    Results
 Top
 Abstract
 Introduction
 Patients and Methods
 Results
 Discussion
 Conclusion
 References
 
Early Outcome
The stent graft delivery was technically successful in all 126 patients. In 6 (4.8%) patients kinking of the stent graft showed a pressure gradient greater than 20 mm Hg. All these patients were successfully treated intraoperatively by endovascular repair with additional bare stent deployment. Concomitant procedures included 4 aortic root replacements, 6 aortic valve replacements, and 8 coronary artery bypass grafts. There were 7 cases of type A acute aortic dissection with malperfusion of the lower extremity. To recanalized the malperfusion, we performed endovascular repair in 4 patients (3 iliac stenting and 1 stenting of the descending aorta) and bypass grafting in 3 (2 aortofemoral bypass and 1 femorofemoral bypass) intraoperatively. The average operative, cardiopulmonary bypass, and circulatory arrest times of the lower body were 401, 147, 31 minutes, respectively.

Operative mortality within 30 days was 4 of 126 (3.2%). Two death were in acute type A dissection (1 due to postoperative heart failure, 1 due to uncontrollable hemmorage from the aortic root with coagulopathy), and another 2 death were in degenerative aneurysm (1 due to stroke, 1 due to postoperative thoracoabdominal aneurysm rupture). There were 7 in-hospital deaths after 30 days (in-hospital mortality 5.5%). The causes of in-hospital mortality were brain infarction (n = 1), sepsis (n = 3), aortoesophageal fistula (n = 1), rupture of thoracoabdominal aortic aneurysm (n = 1), and acute myocardial infarction (n = 1). Aortoesophageal fistula occurred in a patient with ruptured type B aortic dissection with mediastinal hematoma. This patient was treated successfully with the open stent-grafting technique and the aneurysm was successfully excluded, but an aortoesophageal fistula developed after the mediastinal hematoma had absorbed at 38 days postoperatively. The causes of early death within 1 year are listed in Go Table 2. Perioperative morbidity included 7 (5.6%) strokes, 3 (2.4%) cases of paraplegia, and 5 (3.9%) cases of transient paraparesis. No spinal cord ischemia was observed in the patients treated by the delayed exclusion technique. The average number of packed red blood cells transfusions was 14.0 ± 3.1 units and re-exploration for bleeding was required in 3 (2.4%) patients. In 6 (4.8%) with renal failure, transient hemodialysis was required. The length of stay in the intensive care unit ranged from 0 to 60 days, median 4 days.


View this table:
[in this window]
[in a new window]

 
Table 2 Causes of early and late death
 
Postoperative hoarseness occurred in 12 (9.5%) patients; however, 7 (58%) of 12 were fully recovered before hospital discharge. Sixty-three percent of the patients were extubated within 24 hours, and 8 (6.3%) required tracheostomy.

The demographics of patients with paraplegia and transient paraparesis are shown in Go Table 3. All patients with transient paraparesis had recovered enough to be able to walk by themselves. The median hospital stay was 29 days, and 11 (8.7%) of the patients were discharged to an institution for rehabilitation.


View this table:
[in this window]
[in a new window]

 
Table 3 Demographics of spinal cord ischemia
 
Late Outcome
Survival
Actuarial survival estimates 1, 5, and 8 years after the procedure were 81.1%, 63.3%, and 53.7%, respectively (Go Figure 2). Causes of deaths are listed in Table 2. There was 1 (0.79%) late death resulting from rupture of a treated aortic arch aneurysm that was caused by leaking from the proximal suture site of the stent graft. One (0.8%) late fatal aortoesophageal fistula had occurred. This case involved a huge degenerative aneurysm encompassing the whole thoracic aorta with chest pain and a hematoma around the aneurysm (sealed rupture). This patient was treated successfully by extended aortic arch replacement with the open stent-grafting technique; the stent graft was delivered to the 11th thoracic vertebra level by a delayed exclusion technique. The patient had an uneventful recovery, and CT 12 months after the procedure showed shrinkage of the aneurysm (70 mm to 61 mm). However, 28 months after the procedure, CT showed type III endoleak. Additional TEVAR was planned, but the aorta ruptured before treatment was instituted. Emergency TEVAR could have saved the patient's life, but fatal aortoesophageal fistula had occurred.


Figure 2
View larger version (9K):
[in this window]
[in a new window]

 
Figure 2. Overall survival of all 126 patients.

 
Brain infarctions as the cause of death within 1 year were promoted by the surgery, unfortunately. Two late brain infarctions were observed, but neither of them resulted from cerebral graft occlusion or graft thrombosis. Rupture of other aortic aneurysms had occurred while one of the patients was waiting for the next operation; the other patient had refused further treatment. All these patients showed complete exclusion of the treated arch aneurysm on postoperative CT scans, and none of these were associated with stent graft dislodgment or perforation.

Operative mortality, aortoesophageal fistula, stent graft–related mortality (perforation, occlusion, and thromboembolism), and cerebral graft–related mortality were defined as aortic arch–related death, and the freedom from aortic arch–related death was 95.8%, 92.4%, and 92.4% at 1, 5, and 8 years, respectively (Go Figure 3).


Figure 3
View larger version (9K):
[in this window]
[in a new window]

 
Figure 3. Freedom from aortic arch–related death.

 
Endoleaks and aortic intervention
Follow-up CT was obtained in 81.9% of patients who survived longer than 6 months. In degenerative aneurysms, 68.3% of the aneurysms showed disappearance or shrinkage in late follow-up. In aortic dissections, 78.6% have achieved shrinkage of the false lumen. Among these patients, 30.3% showed complete disappearance of the false lumen in the entire aorta, and 48.4% showed disappearance of the false lumen in the thoracic lesion. Creation of a new intimal tear by the edge of the stent graft was not observed in any case.

Late endoleaks were observed in 5 (3.9%) cases (4 in degenerative/atherosclerotic aneurysms, 1 in chronic type B aortic dissection). Type I endoleak from the distal end of the stent graft had occurred in 3 cases, and type III endoleak from the stent-in-stent site in 2 cases. Endoleaks were observed an average of 24.8 months postoperatively, and all of them were successfully treated with additional endovascular repair. Actuarial freedom from endoleaks was 98.0%, 91.1%, and 91.1% for 1 year, 5 years, and 8 years, respectively.

Intervention of another aortic lesion was administered in 10 (7.9%) cases. There were 7 TEVARs and 3 graft replacements (1 thoracoabdominal aortic aneurysm and 2 aascending aortic aneurysms). All of these cases that required intervention for other aortic lesions were aortic dissection cases. The average postoperative duration for intervention of other aortic lesions was 38.3 months (range 3–89 months). Actuarial freedom from aortic intervention (freedom from intervention of endoleaks and other aortic aneurysms) was 97.2%, 83.8%, and 75.4% for 1, 5, and 8 years, respectively.

Major adverse events
In-hospital death, stroke, spinal cord ischemia, aortic rupture, aortoesophageal fistula, and endoleak were defined as major adverse events, and the freedom from major adverse events was 79.9%, 73.8%, and 73.8% at 1, 5, and 8 years, respectively.


    Discussion
 Top
 Abstract
 Introduction
 Patients and Methods
 Results
 Discussion
 Conclusion
 References
 
The open stent-graft technique is a hybrid procedure that combines conventional aortic surgery and endovascular repair. By using the stent graft as an alternative to the distal anastomosis, surgeons can avoid extended dissection of the distal arch and left thoracotomy. This procedure could be completed by making the distal aortic incision between the brachiocephalic artery and left common carotid artery, which provides a better surgical view and hemostasis than traditional anastomosis in aortic arch replacement. Insertion of the stent graft could be performed in a few minutes. Thus this procedure has an advantage in arch aneurysms extending distally to the descending aorta, it being difficult or impossible to perform distal anastomosis by the median approach, or in aneurysms that are expected to have tight adhesion around the distal anastomosis site (eg, redo cases). It is also useful for type A dissections with an intimal tear in the transverse arch or proximal descending aorta that cannot be resected by hemiarch replacement.

In this cohort of 126 patients, the overall operative mortality within 30 days was 3.2%. In degenerative aneurysms, the operative mortality within 30 days was 2.9%. This is comparable with the operative mortality within 30 days of the first-stage operation with the elephant trunk technique in contemporary reports (2.1%–12%).16,17Go However, the elephant trunk technique requires a second-stage operation (mortality 4%–8.5%) to complete the procedure, and there are even a considerable number of patients who do not survive to the second operation. The open stent-grafting technique has an advantage over the elephant trunk technique in that it completes the procedure within a single operation.

In acute type A dissection, the entire intimal tear resection is desirable to achieve a good fate of the remaining dissected aorta.18Go However, extending the procedure to the aortic arch could be associated with increasing mortality.18Go In our series, the mortality in acute dissection is satisfactorily low (6.9%), and this could relate to the fact that this procedure could achieve total arch repair without manipulating more distally to the left common carotid artery, which facilitates the control of bleeding.

Postoperative occurrence of vocal cord paralysis after aortic surgery is considered to be an independent predictor of pulmonary complications and leads to a longer duration of hospital stay.19Go Even with preservation of the recurrent laryngeal nerve, vocal cord paralysis occurs in 21.9% to 32% of aortic arch operations and in most cases does not return to normal movement.20Go Our procedure does not require resection distally to the left artery, and it has the advantage of avoiding recurrent nerve injury. Postoperative vocal cord paralysis was observed in 9.5%, and 58% of them had fully recovered during hospitalization. Mechanical ventilation for more than 72 hours was required in 20.0% in our series and could be low in comparison with other series of aortic arch replacement through a left thoracotomy (36–50%).21,22Go These results suggest that the open stent-grafting technique could contribute to reduced postoperative respiratory failure.

Spinal cord ischemia is a devastating complication of aortic surgery. Our series showed 3 (2.4%) cases of paraplegia and 5 (3.9%) of paraparesis. Among the 3 patients with paraplegia, 2 had intraoperatively hypotensive perfusion of the lower body associated with stent graft stenosis. Inasmuch as hypotension is widely known to be a risk factor for the development of spinal cord ischemia,23Go stent graft stenosis is an important pitfall of this procedure. Designing the stent graft carefully is mandatory when custom-made stent grafts are used.

Among the 5 cases of temporal paraparesis, 2 were type A acute dissections with preoperative malperfusion. Both of them had a clotted false chamber and severely narrowed true chamber in the descending aorta associated with hypoperfusion of the visceral arteries and lower extremity, which raised concern about the occurrence of spinal cord ischemia. The remaining 3 cases except for the hypoperfusion cases were associated with a history of abdominal aortic repair. From 1997, we started to administer CSFD before the operation in cases of previous thoracoabdominal or abdominal aortic repair. No spinal cord ischemia was observed since then except the 2 cases of acute type A dissection with preoperative malperfusion.

In our study, survival at 1, 5, and 8 years was 81.1%, 63.3%, and 53.7%, respectively. Long-term results of extended aortic arch repair are not well described, but our result is comparable with those of other series of simple aortic arch replacement (5-year survival 46%–79%).23-25Go

Despite encouraging early results, there are few reports describing long-term results of endovascular stent graft repair. Demers and his colleagues26Go reported in their study of 103 TEVARs for descending thoracic aorta that freedom from endoleak was 78%, 64%, and 50% at 1, 5, and 8 years, respectively. Freedom from endoleak in this series was 98.0%, 91.1%, and 91.1% for 1, 5, and 8 years, respectively, which could be superior to TEVAR. TEVAR is inevitably associated with some frequency of proximal type I endoleak in the early and long-term follow-up periods, but this is avoidable in the open stent-grafting technique because the proximal end of the stent graft was sutured in a surgical fashion. All 5 patients who had a late distal endoleak were successfully treated with additional TEVAR, and there have been no secondary endoleaks.

Although shrinkage of the aneurysm sac after endovascular repair may be desirable, the persistence of the aneurysm does not represent a failure because a stable aneurysm without endoleak has not been linked to any untoward effects.27Go

On the other hand, sac enlargement implies increased pressure within the aneurysm sac and should be treated promptly. In our series, 3 aneurysms showed enlargement on late follow-up and all of them were associated with type I/type III endoleaks. Also, we have to consider that the intercostal arteries are opened to the excluded aneurysm (type II endoleak) and this requires that the transected stump of the aortic arch be sutured to the stent graft. Inasmuch as these issues should be carefully studied, we perform postoperative CT with contrast medium at the arterial phase and delayed phase to detect endoleaks.

However, type I/type III endoleaks can be treated with additional endovascular repair with a good result. According to type II endoleak, Ohki and colleagues28Go had reported a study using an implantable wireless aneurysm pressure sensor for endovascular repair of abdominal aorta. They showed that the postexclusion pulse pressure was significantly decreasing. In no patient in our series was trouble caused by the pressure inside the aneurysm, such as continuous leaking from ruptured aneurysm or enlargement of the aneurysm with type II endoleak. From these results, the pressure inside the aneurysm (endotension) could be low enough in the clinical point of view.

Limitation of the Study
This is a retrospective cohort study, and the lack of a concurrent control group restricts direct comparison with total arch replacement associated with left thoracotomy. For the precise advantage of open stent-grafting technique to be elucidated, a prospective case–control study would be required. This study includes our earliest experience with stent grafting, so both the technical immaturity and the lack of adequate spinal protection could have caused spinal ischemia. Improved stent graft design, delivery system, and consideration of spinal protection could be associated with better outcomes.


    Conclusion
 Top
 Abstract
 Introduction
 Patients and Methods
 Results
 Discussion
 Conclusion
 References
 
In this study of 126 patients treated with an open stent-grafting technique, satisfactory early results were obtained in both aortic dissections and aortic arch aneurysms with distal extension to the descending aorta. Regarding long-term outcomes, acceptable survival and good avoidance of aortic arch–related death was obtained. The incidence of endoleaks was satisfactorily low and the patients could be rescued by additional endovascular repair. In aortic dissection, this procedure could obtain good clot formation and shrinkage of the false lumen. These results suggest that the open stent-grafting technique is a safe and effective procedure and might be a good alternative to conventional prosthetic replacement for aortic dissections and arch aneurysm with distal extension to the descending aorta.


    Footnotes
 
Read at the Eighty-seventh Annual Meeting of The American Association for Thoracic Surgery, Washington, DC, May 5–9, 2007.


    References
 Top
 Abstract
 Introduction
 Patients and Methods
 Results
 Discussion
 Conclusion
 References
 

  1. Rokkas CK, Kouchoukos NT. Single stage extensive replacement of the thoracic aorta: the arch-first technique. J Thorac Cardiovasc Surg 1999;117:99-105.[Abstract/Free Full Text]
  2. Massimo CG, Perna AM, Cruz Quadron EA, Artounian RV. Extended and total simultaneous aortic replacement: latest technical modifications and improved results with thirty-four patients. J Card Surg 1997;12:261-269.[Medline]
  3. Borst HG, Walterbusch G, Schaps D. Extensive aortic replacement using "elephant trunk" prosthesis. Thorac Cardiovasc Surg 1983;31:37-40.[Medline]
  4. Crawford ES, Coselli JS, Svensson LG, Safi HJ, Hess KR. Diffuse aneurysmal disease (chronic aortic dissection, Marfan, and mega aorta syndromes) and multiple aneurysm. Treatment by subtotal and total aortic replacement emphasizing the elephant trunk operation. Ann Surg 1990;211:521-537.[Medline]
  5. Dake MD, Miller DC, Semba CP, Mitchell RS, Walker PJ, Liddell RP. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aneurysms. N Engl J Med 1994;331:1729-1734.[Abstract/Free Full Text]
  6. Kato M, Ohnishi K, Kaneko M, Imagawa H, Ueda T, Kuratani T, et al. Development of an expandable intra-aortic prosthesis for experimental aortic dissection. ASAIO J 1993;39:M758-M761.[Medline]
  7. Kato M, Matsuda T, Kaneko M, Ueda T, Kuratani T, Yoshioka Y, et al. Experimental assessment of newly devised transcatheter stent-graft for aortic dissection. Ann Thorac Surg 1995;59:908-915.[Abstract/Free Full Text]
  8. Kato M, Matsuda T, Kaneko M, Kuratani T, Mizushima T, Seo Y, et al. Outcomes of stent-graft treatment of false lumen in aortic dissection. Circulation 1998;98(Suppl):II305-II312.[Medline]
  9. Kato M, Ohnishi K, Kaneko M, Ueda T, Kishi D, Mizushima T, et al. New graft-implanting method for thoracic aortic aneurysm of dissection with a stented graft. Circulation 1996;94(Suppl II):II188-II193.[Medline]
  10. Flores J, Kunihara T, Shiiya N, Yoshimoto K, Matsuzaki K, Yasuda K. Extensive deployment of the stented elephant trunk is associated with an increased risk of spinal cord injury. J Thorac Cardiovasc Surg 2006;131:336-342.[Abstract/Free Full Text]
  11. Usui A, Fujimoto K, Ishiguchi T, Yoshikawa M, Akita T, Ueda Y. Cerebrospinal dysfunction after endovascular stent-grafting via a median sternotomy: the frozen elephant trunk procedure. Ann Thorac Surg 2002;74:S1821-S1824.[Abstract/Free Full Text]
  12. Baraki H, Hagl C, Khaladj N, Kallenbach K, Weidemann J, Haverich A, et al. The frozen elephant trunk technique for treatment of thoracic aortic aneurysms. Ann Thorac Surg 2007:S819-S823.
  13. Liu ZG, Sun LZ, Chang Q, Zhu JM, Dong C, Yu CT, et al. Should the ‘elephant trunk’ be skeletonized? Total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissection. J Thorac Cardiovasc Surg 2006;131:107-113.[Abstract/Free Full Text]
  14. Ishihara H, Uchida N, Yamasaki C, Sakashita M, Kanou M. Extensive primary repair of the thoracic aorta in Stanford type A acute dissection by means of a synthetic vascular graft with a self-expandable stent. J Thorac Cardiovasc Surg 2002;123:1035-1040.[Abstract/Free Full Text]
  15. Kato M, Kuratani T, Kaneko M, Kyo S, Ohnishi K. The results of total arch graft implantation with open stent-graft placement for type A aortic dissection. J Thorac Cardiovasc Surg 2002;124:531-540.[Abstract/Free Full Text]
  16. Svensson LG, Kim KH, Blackstone EH, Alster JM, McCarthy PM, Greeenberg RK, et al. Elephant trunk procedure: newer indications and uses. Ann Thorac Surg 2004;78:109-116.[Abstract/Free Full Text]
  17. LeMaire SA, Carter SA, Coselli JS. The elephant trunk technique for staged repair of complex aneurysms of the entire thoracic aorta. Ann Thorac Surg 2006;81:1561-1569.[Abstract/Free Full Text]
  18. Crawford ES, Kirklin JW, Naftel DC, Svensson LG, Coselli JS, Safi HJ. Surgery for acute dissection of ascending aortic dissection: should the arch be included?. J Thorac Cardiovasc Surg 1992;104:46-59.[Abstract]
  19. Ohta N, Kuratani T, Hagihira S, Kazumi K, Kaneko M, Mori T. Vocal cord paralysis after aortic surgery: predictors and clinical outcome. J Vasc Surg 2006;43:721-728.[Medline]
  20. Ishimoto S, Ito K, Toyama M, Kawase I, Kondo K, Oshima K, et al. Vocal cord paralysis after surgery for thoracic aortic aneurysm. Chest 2002;121:1911-1915.[Medline]
  21. Kouchoukos NT, Mauney MC, Masetti P, Castner CF. Optimization of aortic arch replacement with a one-stage approach. Ann Thorac Surg 2007;83:S811-S814.[Abstract/Free Full Text]
  22. Tominaga R, Kurisu K, Ochiai Y, Nakashima A, Masuda M, Morita S, et al. Total arch replacement through the L-incision approach. Ann Thorac Surg 2003;75:121-125.[Abstract/Free Full Text]
  23. Crawford ES, Svensson LG, Hess KR, Shenaq SS, Coselli JS, Safi HJ, et al. A prospective randomized study of cerebrospinal fluid drainage to prevent paraplegia after high-risk surgery on the thoracoabdominal aorta. J Vasc Surg 1991;13:36-45.[Medline]
  24. Okita Y, Ando M, Minatoya K, Kitamura S, Takamoto S, Nakajima N. Predictive factors for mortality and cerebral complications in arteriosclerotic aneurysm of aortic arch. Ann Thorac Surg 1999;67:72-78.[Abstract/Free Full Text]
  25. Kazui T, Washiyama N, Muhammad BA, Terada H, Yamashita K, Takinami M, et al. Total arch replacement using aortic arch branched grafts with the aid of antegrade selective cerebral perfusion. Ann Thorac Surg 2000;70:3-8discussion 8–9.[Abstract/Free Full Text]
  26. Demers P, Miller DC, Mitchell RS, Kee ST, Sze D, Razavi MK, et al. Midterm results of endovascular repair of descending thoracic aortic aneurysms with first-generation stent grafts. J Thorac Cardiovasc Surg 2004;127:664-673.[Abstract/Free Full Text]
  27. Cho JS, Dillavou ED, Rhee RY, Makaroun MS. Late abdominal aortic aneurysm enlargement after endovascular repair with the Excluder device. J Vasc Surg 2004;39:1236-1242.[Medline]
  28. Ohki T, Ouriel K, Silveria PG, Katzen B, White R, Criado F. Initial results of wireless pressure sensing for endovascular aneurysm repair: the APEX trial—acute pressure measurement to confirm aneurysm sac exclusion. J Vasc Surg 2007;45:236-242.[Medline]

Related Article

Discussion
J. Thorac. Cardiovasc. Surg. 2008 135: 1268-1269. [Extract] [Full Text] [PDF]




This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Goro Matsumiya
Masaaki Kato
Hiroshi Takano
Yoshiki Sawa
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Shimamura, K.
Right arrow Articles by Sawa, Y.
PubMed
Right arrow Articles by Shimamura, K.
Right arrow Articles by Sawa, Y.
Related Collections
Right arrow Great vessels
Right arrowRelated Article


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS