J Thorac Cardiovasc Surg 2008;136:688-696
© 2008 The American Association for Thoracic Surgery
Surgery for Acquired Cardiovascular Disease |
Deutsches Herzzentrum Berlin, Berlin, Germany
Received for publication November 12, 2007; revisions received March 28, 2008; accepted for publication May 13, 2008. * Address for reprints: A. Charles Yankah, MD, PhD, Professor of Surgery, Humboldt, Charité Medical University, German Heart Institute Berlin, Augustenburger Platz 1, D-13353 Berlin, Germany. (Email: yankah{at}dhzb.de).
| Abstract |
|---|
|
|
|---|
Methods: Data from 1513 patients with isolated aortic valve replacement who received pericardial bioprostheses between 1986 and 2007 were analyzed. Cumulative duration of follow-up was 6164 patient-years with a maximum duration of 21 years. Actuarial rates of valve-related events were calculated by the Kaplan–Meier method and the Cox multivariate analysis to identify independent determinants of outcome.
Results: Hospital mortality for elective surgery was 2.5%. Late death was 40.6%. Reoperation was required in 86 (5.7%) patients and was valve related in 83: structural valve deterioration in 64 (4.2%) patients, prosthetic valve endocarditis in 17 patients (1.1%), valve thrombosis in 1, and periprosthetic leak in 1. Rates of 20-year actuarial freedom from valve-related morbidity were as follows: structural valve deterioration 84.8% (actual 96.6%) in patients 70 years of age or older; thromboembolism 94.1%; and prosthetic valve endocarditis 96.8%. Twenty-year actual risk of reoperation for structural valve deterioration was 11.4% in all patients and 3.4%, in patients 70 years or age or older. Advanced age, renal insufficiency, pulmonary disease, and low body mass index were independent risk factors for late outcome (P < .001).
Conclusions: After 2 decades of follow-up, the Mitroflow pericardial aortic valve continues to be a valve of choice with a predictable low rate of valve-related events, particularly for patients over the age of 65 to 70 years and others with comorbidities.
| Introduction |
|---|
|
|
|---|
| Patients and Methods |
|---|
|
|
|---|
|
Surgical Technique
Standard surgical procedures were performed as described previously.8
The major aspects of implantation are as follows: Meticulous decalcification is used to avoid abrasion and early alteration to the pericardial valve by residual calcific tissue. The decalcified annulus allows proper matching and secures good coaptation of leaflets.
A sizing obturator is used to measure the native annulus for proper selection of the pericardial valve size, using clinical judgment of the space in the supra-annular area of the aortic sinuses. This will avoid oversizing, which creates valve deformation. In situations in which subaortic obstructive septal hypertrophy is present, incision or preferably resection (myectomy) should be performed. Enlargement of a small aortic annulus is rare, but if it is necessary the Nicks procedure can be performed to avoid squeezing and deformation of the valve.
Despite the valve's low-profile characteristics, proper orientation of the anatomic units of the pericardial prosthesis should be observed.
The valve should be inserted in a supra-annular position to avoid hemodynamic stress, and the valve commissures should correspond to native commissures while the valve sinuses face the coronary ostia to achieve unobstructed coronary ostia. Finally, very tall knots that would expose valve tissue to abrasion, early alteration, and perforation should be avoided.
Data Collection and Postoperative Follow-up
The study, as well as the use of patients' data for research purposes and publication, was approved by the institutional review board and informed consent was obtained from the follow-up patients.
Data acquisition
Patients were examined at our institution or have been contacted by telephone interview and mailed questionnaire. Further patient data were obtained from hospital records, family physicians, and cardiologists. Patients with unknown addresses could be tracked through the district or state registry of residents or birth and deaths.
Total follow-up was 6163.5 patient-years (mean: 4.07 ± 0.12 years, SEM). Eleven (0.7%) patients were lost to follow-up (99.3% complete). A total of 1297 (85.7%) of the hospital survivors underwent routine echocardiographic studies at 3 and 9 months after operation and thereafter annually. Transthoracic Doppler echocardiography was performed at different institutions in a uniform manner and the evaluations were comparable. If a patient had undergone more than one echocardiographic or clinical evaluation, the result of the most recent investigation was reported.
We evaluated 189 measurements of mean gradients in 121 patients. Measurement of mean gradients and time intervals between serial echocardiographic studies were not uniform in some patients. Therefore, we did not apply the mixed model longitudinal regression analysis as described by Banbury and associates.4
We are presenting scatterplots of mean gradients of valve sizes 19 to 25 mm and their median values to demonstrate the evolution of transvalvular mean gradients across time.
Structural and nonstructural valve deterioration of Mitroflow bioprostheses, diagnosed preoperatively by echocardiographic studies, was confirmed at the time of explantation.
At the time of the last follow-up study, 150 patients (29%) were in New York Heart Association (NYHA) class I, 232 (45%) in class II, 120 (23%) in class III, and 14 (3%) patients could not be classified because of advanced age.
Ninety-seven (7.6%) patients were receiving anticoagulation treatment with warfarin sodium (Coumadin) and 260 (20.5%) with antiplatelet drugs. Three hundred fifteen (24.8%) patients 65 years of age or older were receiving anticoagulants as compared with 42 (3.3%) patients younger than 65 years.
NYHA functional classification of the patients was inconsistent and unreliable to reproduce owing to a high proportion of patients at advanced age (mean age at operation 73 years). Many follow-up patients discontinued or irregularly took their drugs partly because of the risk and fear of bleeding and stroke. Therefore, a statistical approach to estimate a time-related proportion of patients in NYHA functional class and receiving anticoagulants did not yield meaningful, reproducible clinical information.
Statistics
The probability of survival, freedom from valve-related morbidity events, death, and reoperation were estimated by Kaplan–Meier actuarial analysis and by linearized occurrence rates. Linearized occurence rates of events and confidence limits were calculated according to Poisson distribution.
Actual competing risk analysis (cumulative incidence) was performed.
Tabular data are summarized by the mean and given with standard error for continuous variables and by percentages for categorical variables. Differences in actuarial freedom between groups of patients are determined by the log–rank test. Differences in prognostic variables between two groups were evaluated by t tests for continuous variables and the
2 or Fisher exact test for categorical variables. Predictors of events during follow-up were identified by the Cox proportional hazards regression.
All variables listed in Table 1 were investigated for association with hospital death, overall death, and valve-related complications by univariate and multivariate analysis. Standard statistical formulas have been used for the analysis of data, as described previously.8
| Results |
|---|
|
|
|---|
The causes of early death were cardiac related in 96 (61%) patients and noncardiac and nonvalve related in 61 (39%) patients. Significant predictive factors for early mortality were emergency operation (OR, 1.53; CI [95% CL] 1.33–1.75; P value < .001) and preoperative renal failure (OR, 2.76; CI [95% CL] 0.98–7.76; P value .054).
Long-term survival
A total of 615 patients died. Twenty-five (4.1%) deaths were valve related. Actuarial freedom from valve-related death at 20 years was 82.9% ± 4.0%.
The actuarial survival including operative death in our cohort at 10, 15, and 20 years was 31.9% ± 1.8%, 12.7% ± 1.4%, and 6.1% ± 1.5%, respectively (Figure 1 ; OR, 1.82; CI [95% CL] 1.55–2.18; P value < .001). Univariate and multivariate analysis showed that NYHA III–IV (OR, 1.37; CI [95% CL] 1.18–1.59; P value < .001), renal insufficiency (OR, 1.74; CI [95% CL] 1.40–2.17; P value < .001), chronic obstructive pulmonary disease (OR, 1.54; CI [95% CL] 1.22–1.95; P value .001), body mass index less than 20 kg/m2 (OR, 1.46; CI [95% CL] 1.13–1.88; P value .001), and advanced age (OR, 1.82; CI, 1.56–2.16; P value < .001) were predictive factors for late death.
|
Of 435 follow-up patients, after 1 year 136 were in NYHA class I, 202 in class II, 87 in class III, and 10 in class IV; after 5 years, of 45 patients 6 were in class I, 19 in class II, 18 in class III, and 2 in class IV; after 10 years, of 36 patients 8 were in class I, 11 in class II, 15 in class III, and 2 in class IV; after 15 years, of 6 patients 1 was in class I, another 1 in class II, 3 were in class III, and 1 in class IV. Anticoagulation was administered in all patients for 6 weeks after discharge. After 1 year 138 of 995 follow-up patients were receiving anticoagulants, after 5 years 116 of 493, after 10 years 52 of 156, and after 15 years 51 of 58 follow-up patients were receiving anticoagulants.
Valve-related Complications
Reoperation
Reoperation was required in 86 patients and was valve related in 83. Causes were as follows: structural valve deterioration (SVD) in 64 (4.2%) cases, valve thrombosis in 1 case (0.07%), periprosthetic leak in 1 case (0.07%), and prosthetic valve endocarditis (PVE) in 17 (1.1%) cases.
The 20-year actual risk of reoperation for all causes was 15.5% with a linearized rate of 1.4%/pt-y (CI, 1.05–1.62).
SVD
Sixty-four (4.2%) patients had primary tissue failure resulting from leaflet calcification or fibrosis causing stenosis in 8, incompetence in 30 (including 1 leaflet tear in Mitroflow early experience), or mixed lesion in 26 patients. Detailed analysis is shown in Table 2
. Overall 20-year freedom from SVD was 62.3 + 5.02%. Actuarial freedom from reoperation for SVD at 20 years in patients aged 65 years or older and 70 years or older was 71.8% ± 6.0% (actual, 92.6 ± 4.6%) and 84.8 ± 0.7% (actual, 96.6% ± 0.8%), respectively (Figures 2–4 and Table 3
). The 20-year actual risk (cumulative incidence) for SVD was 11.4%. The linearized rate of SVD for the entire patient cohort was 0.9%/pt-y. It was 0.76%/pt-y and 0.34%/pt-y for patients aged 65 years or older and 70 years or older, respectively. Younger patients, below the age of 65 years, had a linearized rate for SVD of 2.1%/pt-y (P = .004). Detailed linearized rates of events and confidence limits at different age groups are shown in Table 3
.
|
|
|
|
|
Time-related transvalvular mean gradients and valve size
Repeated measurements of transvalvular mean gradients and valve sizes across time are shown in Table 4
and Figure 5
. Postoperative transvalvular mean gradient with valve size 19 mm was greater than that with 21 mm and 23 mm; however, all were decreased at 1 year.
|
|
In contrast, patients less than 65 years showed a significant increase in transvalvular mean gradient to 40 to 19 mm Hg or more after 10 years for valve sizes 21 and 23 mm (P =.004), leading to reoperation (Figure 2).
Nonstructural valve dysfunction
There was 1 (0.07%) case of nonstructural valve dysfunction: periprosthetic leak (0.07%). An additional 3 dysfunctions were not valve related: 2 technically related (0.13%) and 1 intraoperative mismatch (0.07%) (Table 2).
Thromboembolism
Forty-nine (3.2%) patients had episodes of thromboembolsm (TE) representing an actuarial freedom of 94.1% at 20 years (Figure 6
). The linearized rate was 0.79%/pt-y.(CI, 0.60–1.01). TE occurred in 6 (0.4%) patients under 65 years of age (linearized rate, 0.5%/pt-y; CI, 0.24–1.06) and in 43 (2.8%) patients 65 years of age or older (linearized rate, 0.93%/pt-y; CI, 0.66–1.18). In the 49 patients with stroke, 4 neurologic events were permanent (linearized rate, 0.06%/pt-yr) and 9 (linearized rate, 0.09%/pt-yr; CI, 0.07–0.25) were fatal. TE was recurrent in nine patients. One patient experienced a valve thrombosis (linearized rate: 0.02%/pt-y).
|
PVE
Seventeen (1.1%) patients with a sterile aortic root at primary operation had a prosthetic infection. The organisms associated with late infections were staphylococcal and streptococcal species. Among the 202 patients with healed endocarditis and 40 with active endocarditis, there was 1 episode of reinfection in each group. Significant paravalvular leaks resulting from infection were observed in 5 patients (linearized rate, 0.08%/pt-y; CI, 0.03–0.17) and a leaflet tear in 1 of the patients.
The actuarial freedom from endocarditis was 96.8% ± 0.9% at 20 years and the linearized rate for endocarditis was 0.28%/pt-y (CI, 0.14–0.44, Figure 7 ). There were constant very low hazard events of PVE.
|
| Discussion |
|---|
|
|
|---|
For xenograft tissue valves, the porcine bioprosthesis is taken as the standard against which results can be compared. The potential for a very long-term durability of stented pericardial and stented porcine tissue valves for over 20 years has been demonstrated and reported recently.8,21,22
Statistical comparison between actuarial data reported from various institutions is very difficult, but literature review can help to gain a general impression.5,8,17,18,20,23-25
Although the porcine and pericardial valves are collagen structures treated with glutaraldehyde, their shape, technique of mounting, mode of function, and fluidodynamic characteristics are dissimilar and therefore their long-term performance and mode of failure may be different.
Twenty-one–year durability of the Mitroflow pericardial bioprosthesis attests to the quality of the pericardial tissue and the design/shape of this bioprosthesis. In comparison with porcine valves, the Mitroflow pericardial valve is less obstructive especially in the 19- and 21-mm sizes and even competes well with porcine stentless valves.8,14-20
Sustained long-term durability over 21 years has been demonstrated in patients older than 70 years with 84.8% (actual, 96.6%) free of SVD.
The 72% 21-year actuarial (actual, 92.6%) freedom from SVD in patients over 65 years with Mitroflow pericardial tissue valves compares favorably with Hancock II (Medtronic, Inc, Minneapolis, Minn) porcine valves (actuarial freedom from SVD of 73%.) in patients in similar age groups.21
Other reports also confirmed that the pericardial valve is as durable as porcine and allograft valves at ages above 65 years.24
Several authors have reported leaflet tears and early SVD even in elderly patients, which was a rare event in our series.1-3,5,21,26
The etiology of early SVD associated with leaflet tears in a subgroup of elderly patients is not clearly understood.
In our series, leaflet tears or disruptions occurred in 2 patients. Leaflet tear as a primary tissue failure occurred in 1 patient, which represents a linearized rate of 0.02%/pt-y (CI, 0.0004–0.08), whereas the other leaflet tear was associated with PVE. This indicates that if there is a history of endocarditis, as we encountered in our patient, the tear is secondary to the infection and the complication has to be classified as endocarditis and excluded from the SVD group, as reported in the guidelines of Edmunds and associates27
and by other authors.21,29,30
Acceleration of structural deterioration could occur after a successful treatment of endocarditis.7,28
It is therefore important to consider the history of previous antibiotic treatment and exclude endocarditis as an underlying cause before classifying a tear as a primary tissue failure.
The analysis of our 21-year results with Mitroflow pericardial bioprostheses in the aortic position has shown it to be safe even at withdrawal of anticoagulation or antiplatelet treatment in 92% and 80% of the patients, respectively. The risk of late TE complications impact with an incidence of 3.8% and a linearized rate of 0.79%/pt-y (CI, 0.60–1.01).
The major indication for long-term anticoagulation was atrial fibrillation. Valve thrombosis and lethal TE were encountered in 1 (0.02%/pt-y) and another 9 (0.7% pt-y) patients in this series, respectively, and the potential hazard of anticoagulant-induced hemorrhage was significantly low (n = 4, 0.3%) with a linearized rate of 0.06%/pt-y (CI, 0.02–0.15).
The incidence of 3.4% TE complications in patients older than 65 years of age could be explained by the fact that the average patient age in the series was over 73 years and the risk of cerebral accidents developing from unrecognized cerebrovascular lesions without cardiac surgery was already high.26
The disparity in TE rates between our series and recently published data with porcine valves is evident.5,18,21-23,25
The lower propensity for TE in our cohort with the Mitroflow pericardial valve relates to the quality of the tissue and the design of the prosthesis. Although the exact etiology of early TE is not widely established, our experience has indicated that many patients could benefit from anticoagulant treatment for the initial 6 weeks after bioprosthetic aortic valve replacement. In the presence of one or more factors associated with an increased risk of TE (atrial fibrillation, enlarged left atrium with or without thrombus, recurrent atrial fibrillation after ablation), such patients with tissue valves should receive lifelong anticoagulant therapy.
Concomitant coronary artery bypass graft operation was not found to be a risk factor for operative death. The low patient survival of 6% at 21 years with a median probability of survival time of 6.8 years is attributed to the average patient age of 73 years at implantation in our series, and it is in line with the results obtained from meta-analysis of life expectancy, which was 10.7 years for a 65-year-old patient after aortic valve replacement.29
Furthermore, after 15 years the Kaplan–Meier estimates for patient survival are not as reliable as the initial estimates because of the limited number of patients at risk beyond 15 years. This translates in the mean follow-up per patient, which is 4.07 years per patient in the present study and 4.85 years per patient in the 2003 study.8
Actuarial freedom from valve-related death in our series was 94% at 10 years and 83% at 20 years. The result is in line with data published by others.4,17,19
Although autopsies were not performed in some patients who died with known causes, they were performed in cases of unexplained or sudden death with some exceptions (religious or cultural). Figures on SVD were obtained at reoperation or autopsy.27
The available autopsy results did not show any acute SVD or leaflet rupture as a cause of death. The long-term patient mortality was caused much more commonly by patient-related factors than by the presence of the Mitroflow pericardial valve prosthesis, as described in the paragraph on long-term survival of this article. Valve-related death of 4.1% (25/615) was therefore low in our series and was overestimated as sudden or unexplained patient death and was the most common cause of valve-related death. There was no direct correlation between valve size and early or late death in patients with 19- to 21-mm and 23- to 25-mm Mitroflow bioprostheses (P = .458 and P = .286). Further analysis to correlate with NYHA functional class revealed even better results for smaller valve sizes 19 to 21 mm (P = .003, P = .034).
Inasmuch as the physical capacity of elderly patients may diminish over time, we did not use change in NYHA class as a function for SVD or patient–prosthesis mismatch in these patients without echocardiographic evidence. The analysis has ruled out hemodynamically relevant patient–prosthesis mismatch and testifies to the excellent hemodynamic performance of small sizes of Mitroflow bioprostheses (mean transvalvular gradient [mm Hg]/effective orifice area [cm2] of 9.4 mm Hg/1.4 cm2, 7.1 mm Hg/1.6 cm2, and 4.7 mm Hg/1.85 cm2 for valve sizes 19 mm, 21 mm, and 23 mm, respectively) as compared with other bioprostheses.4,8,12-20
Repeated measurements of transvalvular mean gradients in relation to Mitroflow pericardial valve size across time in patients aged 65 years or older showed that mean transvalvular gradient at 5 years for valve sizes 19 to 23 mm was 12 to 5 mm Hg. This increased to 18 to 8 mm Hg after 10 years and then remained stable at 15 and 20 years for valve sizes 21 and 23 mm, respectively.
In contrast, patients younger than 65 years showed an increase in transvalvular mean gradient to 40 to 19 mm Hg after 10 years for valve sizes 21 and 23 mm, which led to reoperation.
Patient–prosthesis mismatch was rare in our series, however, 2 patients with 19-mm and 21-mm valves in the supra-annular position were identified with a classic prosthesis–patient mismatch (effective orifice area, 0.8 cm2/m2), which could have been avoided by myectomy and the Nicks procedure for enlargement of the noncoronary sinus, respectively.
Frater,17
Banbury,4
and their associates reported mean gradients of 22 to 15 mm Hg and 22 to 12 mm Hg for Carpentier–Edwards Perimount pericardial valve (Edwards Lifesciences, Irvine, Calif) sizes 19 to 25 mm at 12 and 17 years in patients at a mean age of 65 years, respectively. The gradients reported were somewhat greater than those we found in our cohort at 15 and 20 years. SVD observed in the first 5 years (n = 7; linearized rate, 0.4%/pt-y; CI, 0.18–0.87) in our cohort was confounded by sequelae of radiotherapy for cancer, implantation technical reasons including a rare patient–prosthesis mismatch, and subclinical endocarditis, whereas SVD beyond the 5-year period in the first decade was associated with age below 65 years.1,5,7,20,21
PVE was a rare event that occurred in 17 (1.1%) patients, and the rate of recurrent infection was 0.8% (n = 2). The actuarial freedom from PVE was 96.8% ± 0.0.9% and the linearized rate was 0.28%/pt-y (CI, 0.14–0.44). The hazard rate for PVE was constantly very low.20
Our results suggest that the freedom from valve-related SVD, as well as the freedom from reoperation, and the TE rate are all very competitive with results published for other bioprostheses.17,18,21-25
The freedom from SVD and reoperation are age related, as is the case in other reports of series with bioprostheses.17,18,21,24
These data support our proposals that the Mitroflow prosthesis is the valve of choice in patients over the age of 65 to 70 years and a logical and safe choice for patients younger than 65 years of age with comorbidities.
| Conclusions |
|---|
|
|
|---|
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
S. Martens, J. Sadowski, F. S. Eckstein, K. Bartus, B. Kapelak, H.-H. Sievers, C. Schlensak, and T. Carrel Clinical experience with the ATS 3f Enable(R) Sutureless Bioprosthesis Eur J Cardiothorac Surg, September 1, 2011; 40(3): 749 - 755. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. R. E. Jamieson, C. T. P. Lewis, M. P. Sakwa, D. A. Cooley, V. R. Kshettry, K. W. Jones, T. E. David, J. A. Sullivan, G. J. Fradet, and D. S. Bach St Jude Medical Epic porcine bioprosthesis: Results of the regulatory evaluation J. Thorac. Cardiovasc. Surg., June 1, 2011; 141(6): 1449 - 1454.e2. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Myken and O. Bech-Hansen Reply to the editor. J. Thorac. Cardiovasc. Surg., February 1, 2011; 141(2): 596 - 597. [Full Text] [PDF] |
||||
![]() |
The ISTHMUS Investigators The Italian study on the Mitroflow postoperative results (ISTHMUS): a 20-year, multicentre evaluation of Mitroflow pericardial bioprosthesis Eur J Cardiothorac Surg, January 1, 2011; 39(1): 18 - 26. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. A. Yankah Mitroflow pericardial aortic bioprosthesis in patients younger than 60 years J. Thorac. Cardiovasc. Surg., November 1, 2010; 140(5): e83 - e84. [Full Text] [PDF] |
||||
![]() |
W. R. E. Jamieson Reply to Quiroga et al. Eur J Cardiothorac Surg, November 1, 2010; 38(5): 649 - 650. [Full Text] [PDF] |
||||
![]() |
C. Valfre, P. Ius, G. Minniti, L. Salvador, T. Bottio, F. Cesari, G. Rizzoli, and G. Gerosa The fate of Hancock II porcine valve recipients 25 years after implant Eur J Cardiothorac Surg, August 1, 2010; 38(2): 141 - 146. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Conte, N. Weissman, J. A. Dearani, J. Bavaria, D. Heimansohn, W. Dembitsky, and D. Doyle A North American, Prospective, Multicenter Assessment of the Mitroflow Aortic Pericardial Prosthesis Ann. Thorac. Surg., July 1, 2010; 90(1): 144 - 152. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Rahimtoola Choice of Prosthetic Heart Valve in Adults: An Update J. Am. Coll. Cardiol., June 1, 2010; 55(22): 2413 - 2426. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. S. McClure, N. Narayanasamy, E. Wiegerinck, S. Lipsitz, A. Maloney, J. G. Byrne, S. F. Aranki, G. S. Couper, and L. H. Cohn Late Outcomes for Aortic Valve Replacement With the Carpentier-Edwards Pericardial Bioprosthesis: Up to 17-Year Follow-Up in 1,000 Patients Ann. Thorac. Surg., May 1, 2010; 89(5): 1410 - 1416. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. R. E. Jamieson, R. Koerfer, C. A. Yankah, A. Zittermann, R. I. Hayden, H. Ling, R. Hetzer, and W. B. Dolman Mitroflow aortic pericardial bioprosthesis -- clinical performance, Eur J Cardiothorac Surg, November 1, 2009; 36(5): 818 - 824. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||