JTCS KCI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Michal Krejca
Andrzej Bochenek
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bis, J.
Right arrow Articles by Bochenek, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Bis, J.
Right arrow Articles by Bochenek, A.
Related Collections
Right arrow Congestive Heart Failure

J Thorac Cardiovasc Surg 2008;136:786-787
© 2008 The American Association for Thoracic Surgery


Brief Communication

Surgical extraction of cardiac resynchronization therapy system with concomitant implantation of a new system with the use of epicardial leads in a patient with endocarditis

Jaroslaw Bis, MDa,*, Kinga Goscinska-Bis, MDb, Michal Krejca, MDa, Elzbieta Zinka, MDc, Janusz Skarysz, MDa, Leszek Machej, MDa, Andrzej Bochenek, MDa

a First Department of Cardiac Surgery, Medical University of Silesia, Katowice, Poland
b Department of Electrocardiology, Medical University of Silesia, Katowice, Poland
c Department of Cardiology, District Hospital, Koszalin, Poland

Received for publication October 7, 2007; accepted for publication November 21, 2007.

* Address for reprints: Jaroslaw Bis, MD, First Department of Cardiac Surgery, ul. Ziolowa 47, 40-635 Katowice, Poland. (Email: bisu{at}mp.pl).

Endocarditis related to a transvenously implanted cardiac resynchronization therapy (CRT) system is a rare but serious therapeutic challenge, particularly in those patients in whom interruption of biventricular stimulation induces dramatic deterioration of their hemodynamic status.

Clinical Summary

We report the case of a 57-year-old man with a CRT system implanted transvenously in 2003 owing to dilative cardiomyopathy, in whom infective endocarditits with blood cultures positive for methicillin-resistant Staphylococcus epidermidis was diagnosed. The preoperative transthoracic echocardiogram revealed abnormal, moving echoes in the right atrium, impaired left ventricular ejection fraction of 20%, moderate mitral regurgitation, and severe tricuspid regurgitation. Transesophageal echocardiography confirmed the presence of two large vegetations (>1 cm in diameter) attached to the pacing leads within the right atrium (Figure 1 ). A temporary interruption of biventricular stimulation during preoperative echocardiography induced a deterioration of global systolic function, appearance of asynchrony, increase in mitral regurgitation, and after 15 minutes, signs of dyspnea and orthopnea. Consequently, the patient was qualified for a combined procedure of surgical removal of the infected CRT system with concomitant implantation of a new system with the use of epicardial leads.


Figure 1
View larger version (52K):
[in this window]
[in a new window]

 
Figure 1. Transesophageal echocardiogram showing two vegetations greater than 10 mm in diameter in the right atrium.

 
The intervention was carried out with a median sternotomy approach, cardiopulmonary bypass, and cardioplegic arrest. After opening of the right atrium, the left ventricular lead proved to be firmly connected to the atrial wall by a tissue sleeve (Figure 2 ). Its mobilization was possible only after careful surgical separation. Subsequently, the distal ends of all three leads were completely removed from the heart and cut off at the level of the superior vena cava. The examination of the tricuspid valve did not reveal any pathologic condition necessitating surgical intervention. Bipolar epicardial leads (CapSure Epi 4968; Medtronic, Inc, Minneapolis, Minn) were implanted on the right atrium, right ventricle, and the lateral wall of the left ventricle within the most delayed segment according to the preoperative echocardiographic study. After release of the crossclamp, in the reperfusion period the pacing and sensing parameters were verified and subsequently the leads were connected to the biventricular pacemaker (Insync III; Medtronic) located in the abdominal wall. The biventricular stimulation was activated. After weaning from cardiopulmonary bypass, the sternotomy was closed routinely, and subsequently the old pacemaker was removed completely with the proximal ends of the old leads. The postoperative course was uneventful. The samples cultures confirmed the S. epidermidis etiology of the infection. After 30 days of antimicrobial treatment, the blood cultures were sterile and the patient's clinical status improved. In the predischarge echocardiogram, an improvement in CRT effect compared with preoperative status was confirmed with a left ventricular ejection fraction of 35% and a reduction in mitral and tricuspid regurgitation. The patient was discharged in very good general condition and leads a normal life.


Figure 2
View larger version (94K):
[in this window]
[in a new window]

 
Figure 2. CRT system extracted from the patient.

 
Discussion

In recent years CRT has been proved to be an effective treatment option for patients with congestive heart failure and systolic dyssynchrony.1Go However, the increasing implementation of CRT in clinical practice will result in a growing number of patients with endocarditis related to CRT pacing leads. It has been demonstrated that the only efficient treatment method of endocarditis on pacemaker leads is the removal of the entire pacing system.2,3Go On the other hand, in some patients with advanced heart failure, the continuity of CRT therapy with its acute beneficial impact on systolic synchrony, diastolic filling time, and mitral regurgitation is crucial for maintaining hemodynamic stability.

In this setting, the surgical extraction of the CRT system with concomitant implantation of the new system with the use of epicardial leads may be a promising solution.

Moreover, the excellent exposition of the heart helps to overcome the limitations associated with coronary sinus anatomy, inasmuch as the left ventricular lead can be easily placed at the optimal site, which is of greatest importance for maximizing the benefit from CRT.4Go

We used bipolar nonpenetrating epicardial leads. The steroid-eluting tips prevent local fibrosis at the implantation site and ensure very good pacing and sensing parameters at long-term follow-up.4Go

Some authors advocate transvenous pacemaker lead removal regardless the size of vegetations.5Go However, an extensive body of evidence supports the strategy of surgical extraction in case of vegetations exceeding 10 mm in diameter to prevent embolic complications.2Go Moreover, in this case an attempt at transvenous removal could be risky considering the solid tissue sleeve connecting the left ventricular lead to the atrial wall (Figure 2).

In conclusion, we propose surgical extraction of the transvenously implanted CRT system with concomitant implantation of a new epicardial system as an effective treatment method of infective endocarditis, without the necessity of CRT interruption.

References

  1. Vardas PE, Auricchio A, Blanc JJ, Daubert JC, Drexler H, Ector H, et al. Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association. Eur Heart J 2007;28:2256-2295.[Free Full Text]
  2. Klug D, Lacroix D, Savoye C, Goullard L, Grandmougin D, Hennequin JL, et al. Systemic infection related to endocarditis on pacemaker leads: clinical presentation and management. Circulation 1997;95:2098-2107.[Abstract/Free Full Text]
  3. Sohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, et al. Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections. J Am Coll Cardiol 2007;49:1851-1859.[Abstract/Free Full Text]
  4. Mair H, Sachweh J, Meuris B, Nollert G, Schmoeckel M, Schuetz A, et al. Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing. Eur J Cardiothorac Surg 2005;27:235-242.[Abstract/Free Full Text]
  5. Ruttmann E, Hangler HB, Kilo J, Hofer D, Muller LC, Hintringer F, et al. Transvenous pacemaker lead removal is safe and effective even in large vegetations: an analysis of 53 cases of pacemaker lead endocarditis. Pacing Clin Electrophysiol 2006;29:231-236.[Medline]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Michal Krejca
Andrzej Bochenek
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bis, J.
Right arrow Articles by Bochenek, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Bis, J.
Right arrow Articles by Bochenek, A.
Related Collections
Right arrow Congestive Heart Failure


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS