J Thorac Cardiovasc Surg 2008;136:1586-1592
© 2008 The American Association for Thoracic Surgery
Cardiothoracic Transplantation |
Department of Cardiovascular Surgery, Kyushu University, Fukuoka, Japan
Received for publication May 3, 2008; revisions received July 9, 2008; accepted for publication July 26, 2008. * Address for reprints: Yoshihisa Tanoue, MD, Department of Cardiovascular Surgery, Kyushu University, 3-1-1 Maidashi Higashi-ku Fukuoka, 812-8582, Japan. (Email: tanoue{at}heart.med.kyushu-u.ac.jp).
| Abstract |
|---|
|
|
|---|
Methods: This experiment was performed with an isolated working rabbit heart model and a support rabbit. Donor hearts (control group, n = 8) were arrested with an extracellular type of cardioplegia, preserved with University of Wisconsin solution, and then immersed in University of Wisconsin solution for 24 hours (1°C). The Rho-kinase inhibitor (Rho-kinase inhibitor group, n = 8) was administrated in the cardioplegic solution, the preservation University of Wisconsin solution, and the storage University of Wisconsin solution. Left ventricular performance was evaluated from the modified Frank–Starling curve in the working mode. Coronary blood flow and donor heart rate were measured in Langendorff mode. Effective evaluation of the Rho-kinase inhibitor was inferred from phosphorylated myosin light chain. The expression of endothelial nitric oxide synthase mRNA was analyzed to assess endothelial function.
Results: The Frank–Starling curve showed a significant left and upward shift in the Rho-kinase inhibitor group compared with the control group (P < .05). The coronary blood flow and heart rate in the Rho-kinase inhibitor group at 120 minutes was significantly higher than in the control group (P < .05). Phosphorylated myosin light chain was significantly suppressed in the Rho-kinase inhibitor group (P < .05). Endothelial nitric oxide synthase mRNA levels in the Rho-kinase inhibitor group increased 4-fold relative to those seen in the control group.
Conclusions: Treatment with Rho-kinase inhibitor during allograft harvest and storage enhanced coronary blood flow and ventricular recovery through nitric oxide–dependent endothelial protection after reperfusion. Rho-kinase inhibitor could help prevent early myocardial dysfunction after transplantation.
| Introduction |
|---|
|
|
|---|
The small guanosine triphosphate binding protein, Rho, and its downstream effecter, Rho-kinase, are involved in signal transduction initiated by agonists such as angiotensin II, thrombin, endothelin I, norepinephrine, and urotensin in both endothelium and vascular smooth muscle.3
The Rho-kinase signaling pathway plays an important role in vascular diseases, including hypertension, myocardial and cerebral infarction, vascular spasm, atherosclerosis, and ischemia–reperfusion injury.3-5
The pathogenic cellular upregulation of Rho and Rho-kinase affects actin cytoskeleton organization, cell adhesion and migration, and apoptosis; increased monocyte chemoattractant protein 1 and plasminogen activator inhibitor 1 levels; and reduced endothelial nitric oxide synthase (eNOS) levels.3,6-8
Rho-kinase inhibitors (RKIs) can ameliorate various pathogenic vascular disorders in both animals and human subjects.4,9-10
The direct influence of a RKI, fasudil hydrochloride, in prolonged organ preservation has not been defined. To develop appropriate preservation and prevent ischemia–reperfusion injury, we supplemented cardioplegic and preservation solutions with RKI and evaluated functional recovery using an isolated working rabbit heart model with a support rabbit.11-13
We hypothesized that adding RKI to both cardioplegic and preservation solutions would provide both endothelial and myocardial preservation after reperfusion.
| Materials and Methods |
|---|
|
|
|---|
Animal Preparation
Forty male Japanese white rabbits (16 donor rabbits, 16 support rabbits, and 8 blood donors) weighing 3.0 to 3.3 kg were used. General anesthesia was induced with sodium thiamylal (20 mg/kg) through the dorsal marginal ear vein, and then a tracheal tube was inserted through the mouth and connected to a mechanical ventilator with 100% oxygen. Additional vecuronium bromide (1 mg/kg) and fentanyl citrate (30 µg/kg) were intravenously administered. The femoral arterial pressure of both donor and support rabbits was monitored continuously. This study was performed with an isolated working rabbit heart model using support rabbit blood, as described in detail by Kajihara and colleagues.11-13
Donor Heart Management
The donor rabbit heart and aortic arch were exposed through a median sternotomy. After heparinization (300 U/kg), the innominate artery was cannulated to administer the cardioplegic solution. The inferior vena cava was transected to decompress the heart, and then the aortic arch was crossclamped. In the control group (n = 8) cardiac arrest was induced with an infusion of 10 mL/kg extracellular-type Kyushu University cardioplegic solution,13,14
and then 20 mL/kg University of Wisconsin (UW) preservation solution was infused to wash out the coronary vascular cardioplegia. The excised heart was immersed in UW solution (55 mL) for 24 hours. The temperature and administration velocity of both cardioplegic and UW solutions were maintained at 4°C and 12 mL/min, respectively. In the RKI group 0.1 mg/kg RKI was administered with the cardioplegia and UW solutions, and 0.5 mg/kg RKI was added to the immersion UW solution. All excised hearts were preserved at 1°C by using heat exchange for 24 hours, followed by 120 minutes of reperfusion.
Support Rabbit and Cross-circulation System
After induction of general anesthesia and heparinization (300 U/kg), the common carotid arteries and external jugular veins of support rabbits were exposed and cannulated. Fentanyl citrate (100 µg/h), vecuronium bromide (1 mg/h), and heparin (1000 U/h) were used to maintain anesthesia and prevent coagulation. Oxygenated blood from the common carotid artery of the support rabbit was introduced to a cannula connected to the ascending aorta of the donor heart with a microtube pump. Blood draining from the system was returned to the jugular vein through another microtube pump. The pulmonary vein and vena cava of the donor heart were closed, and a double-lumen cannula was inserted into the left atrium. One lumen was connected to a pressure transducer to measure left atrial pressure (LAP). The other lumen was connected to an atrial reservoir (preload). During systemic circulation, hematocrit levels in the perfusion blood were maintained at more than 23%, and blood temperature was maintained at 37°C. Arterial perfusion blood gas and pH were normalized by changing the settings of the mechanical ventilator and using sodium bicarbonate. The hemodynamics of the support rabbit were stabilized by maintaining a systolic blood pressure of greater than 90 mm Hg. At the end of the study, the donor heart was cut into 3 transverse slices, and pieces of each slice were stored at –80°C. The remaining block was fixed in 10% formaldehyde.
Modified Frank–Starling Curve
The donor heart was perfused and stabilized with constant coronary perfusion at 60 mm Hg in Langendorff mode for 60 minutes, and then the working mode was started. In working mode the heart was paced atrially at 250 beats/min, and the aortic afterload pressure was fixed at 60 mm Hg. LAP was gradually increased by raising the atrial reservoir, and aortic flow rates were measured at each level of LAP. Based on these data, we constructed a modified Frank–Starling curve. After measurement of left ventricular (LV) function, the working mode was reversed to Langendorff mode, and at 120 minutes after reperfusion, LV function was evaluated in working mode again.
Coronary Blood Flow and Heart Rate
The maximum coronary blood flow (CBF) and heart rate of the donor heart were measured in Langendorff mode at 10, 60, and 120 minutes after reperfusion.
Measurement of Creatine Kinase–MB
Serum creatine kinase–MB (CKMB) levels were measured with a chemiluminescent immunoassay (SRL, Inc, Tokyo, Japan). The change of CKMB level between 60 and 120 minutes is presented, with the level at 60 minutes representing 100%.
Quantitative Real-time Reverse Transcriptase–Polymerase Chain Reaction
The gene expression of eNOS in myocardium was measured by means of quantitative real-time reverse transcriptase–polymerase chain reaction performed according to the recommendations of the Premix Ex Taq-Perfect Real-Time protocol (Takara Bio, Inc, Shiga, Japan). Total RNA was isolated from homogenized myocardium with ISOGEN (Nippon Gene Co Ltd, Toyama, Japan). The PrimeScript first strand cDNA (Takara Bio, Inc) was made with random primers to reverse transcribe RNA to cDNA. The eNOS probe and primers were designed based on the published sequence of rabbit eNOS (GenBank accession no. AY964103)15
and were produced by Applied Biosystems Japan Ltd. The amount of target cDNA was quantified on a Sequence Detection System ABI 7000 (Applied Biosystems Ltd, Foster City, Calif) by using rabbit eNOS-specific primers and probe. Relative gene expression was calculated by using the 
cycle threshold (Ct) method. Relative eNOS levels were determined by normalizing the Ct value to the rabbit glyceraldehyde-3-phosphate dehydrogenase signal measured from the same sample. The sample with lowest eNOS expression was arbitrarily selected as a calibrator value, and the other quantities are expressed as an n-fold difference relative to this calibrator.
Western Blot Analysis for Phosphorylated Myosin Light Chain
The extent of phosphorylation of the 20-kd myosin light chain (MLC) in myocardium was quantified by means of Western blot analysis, as previously described, to evaluate Rho-kinase activity.16
Protein samples were separated by means of SDS-PAGE with 15% Tris-HCL gels (Bio-Rad Laboratories, Inc, Tokyo, Japan). Twenty microliters of each sample containing 50 µg of protein was applied to the gel and run for 90 minutes at 100 V. Separated proteins were transferred to a membrane at 100 V for 60 minutes. The membrane was incubated with an anti-mouse monoclonal phosphorylated-MLC (p-MLC) antibody (Cell Signaling Technology, Inc, Danvers, Mass), followed by incubation with an anti-mouse IgG horseradish peroxidase–labeled secondary antibody. The region containing MLC was detected with a monoclonal anti-mouse MLC primary antibody (Sigma–Aldrich, Inc, St Louis, Mo) and an anti-mouse IgM horseradish peroxidase–labeled secondary antibody. After detection was performed with a luminoimage analyzer, the intensity of both the unphosphorylated and phosphorylated MLC bands was quantified with National Institutes of Health Image J software. The percentage of the phosphorylated form was measured to express the extent of the MLC phosphorylation. HEK293 cells were used as a positive control for both specific primary antibodies.
Histology in the Myocardium
Cardiac tissue was fixed in 10% formaldehyde, dehydrated, and embedded in paraffin. Each block was cut into 5-µm-thick slices and stained with hematoxylin and eosin to evaluate infiltrating cells.
Apoptotic myocytes were detected with a terminal deoxynucleotidyl transferase–mediated dUTP nick end labeling (TUNEL) assay by using a Mebstain Apoptosis Kit II (Medical and Biological Laboratories Co, Ltd, Nagoya, Japan), according to the manufacturer's instructions. Myer's hematoxylin was used as the counterstain. The ratio of TUNEL-positive nuclei per 1000 total nuclei was measured.
Statistical Analysis
SPSS statistical software for Windows (version 15.0; SPSS, Inc, Chicago, Ill) was used for data analysis. Data are expressed as the mean value ± standard error of the mean. Statistical comparisons were performed by using unpaired Student t tests. The relationship between LAP and aortic flow was analyzed by using a multiple regression model with a dummy variable technique to investigate intergroup differences.
| Results |
|---|
|
|
|---|
|
|
CBF and Heart Rate
The maximum CBF at 10, 60, and 120 minutes after reperfusion in each group is shown in Figure 2, A
. The CBF in the RKI group at 10 and 120 minutes was significantly higher than in the control group (P < .05). The heart rate of the donor after reperfusion was more similar to the normal rabbit rate in the RKI group than in the control group (Figure 2, B).
|
|
Suppression of MLC Phosphorylation by RKI
RKI treatment significantly blocked the extent of MLC phosphorylation (the phosphorylated form as a percentage of total MLC) at 2 hours after reperfusion (P < .05; Figure 3, C).
Pathologic Findings
There was no obvious change in myocardial or vascular structure in the control and RKI groups, and infiltrating cells were not observed. TUNEL-positive nuclei were detected in 0.3% per 1000 nuclei in the control group and 0.1% per 1000 nuclei in the RKI group (P = .4).
| Discussion |
|---|
|
|
|---|
This experimental model offers major advantages, in particular by demonstrating pharmacologic effects at the organ level. Use of a working mode and a support rabbit provided a closer approach to in vivo conditions. Perfusate containing erythrocytes, leukocytes, platelets, and inflammatory cytokines is more commonly compared with crystalloid perfusion fluid, which not only affords oxygen-carrying capacity and coronary flow autoregulation within the physiologic range but also provides biochemical functions, such as buffering of oxygen radicals and catabolism of nitric oxide (NO).
RKI
RKIs are beneficial in organ transplantation. Shiotani and colleagues17
demonstrated that RKI reduced acute hepatocellular necrosis and apoptosis induced by cold ischemia–reperfusion injury in a rat model of liver transplantation. Hattori and associates9
described that long-term treatment with RKI suppressed cardiac allograft vasculopathy in mice. The influence of Rho-kinase during cardiac allograft storage is not clear.
The report by Yada and coworkers10
showed that RKI supplanted directly to the coronary artery dose-dependently caused vasodilatation and increased CBF in a canine model. The most effective dose of RKI was 0.1 mg/kg. Thus we used that dose of RKI in the supplanted solution directly. Our preliminary experiment of 1 mg/kg RKI supplanted into the cardioplegic solution did not improve cardiac recovery. Moreover, RKI added to the support rabbit during reperfusion produced profound systemic vasodilation and instability. Therefore we assessed RKI during harvest and allograft storage to minimize changes in the systemic pressure of the support rabbit.
Inokuchi and colleagues18
reported that fasudil (1.5 mg/kg) administered into intractable spastic arteries was effective in a clinical setting and showed few systemic adverse effects. Species differences could account for these different dosing needs.
Fasudil hydrochloride and Y27632 are available RKIs. We chose the former because it is already available in clinical settings.4,5
The latter is used only in animal studies because of its metabolic byproducts.
Enhanced Cardiac Function Recovery
Allograft contractile performance was evaluated with modified Frank–Starling curves. RKI enhanced the recovery of LV function after reperfusion. The curve at 60 minutes in the RKI group was close to that of a normal heart, as was shown in our previous study.12
After ischemia and reperfusion, intracellular Rho-kinase is induced by angiotensin II, thrombin, and endothelin I. Antagonists or inhibitors for those agonists usually attenuate ischemia–reperfusion injury,3
with efficacy similar to that of RKI, indicating that RKI influences multiple signaling pathways.
In the RKI group increased CBF might result from preserved endothelial function and coronary vasodilatation. Improved endothelial function could result in enhanced contractile function by improving myocardial perfusion and a washout of toxic metabolites that accumulate during storage. RKI treatment slightly increased CKMB levels at 120 minutes but did not change necrosis or myocardial structure under hematoxylin and eosin staining and did not affect apoptosis. Such changes would presumably appear later because the allograft was appropriately preserved and incidental apoptosis in ischemia–reperfusion injury develops during late reperfusion.19
Preserved Endothelial Function
Postischemic endothelial dysfunction occurs in several models of cardiac injury.20
The primary consequence of impaired endothelial function is the reduction of NO production released by endothelial cells. NO is synthesized from L-arginine by NO synthase and modulates vascular tone, attenuates platelet aggregation and neutrophil function,21
and reduces free radical damage.22
NO synthesis inhibitors and eNOS-deficient mice increase infarct size after ischemia and reperfusion.23
Therefore restored NO synthesis is mandatory for appropriate cardiac performance. RKI exerts cardioprotective effects on coronary ischemia–reperfusion injury in vivo, possibly by preserving eNOS expression.24
The overexpression of a dominant-negative mutant of Rho A in cultured endothelial cells upregulates the expression of eNOS mRNA, and the activation of Rho A downregulates eNOS mRNA.25
Inhibition of Rho-kinase signaling helps preserve eNOS mRNA levels.
NO production can be evaluated by measuring the amount of NO in serum samples, Western blotting for eNOS, and detection of eNOS mRNA by means of polymerase chain reaction, but we prefer real-time reverse transcriptase–polymerase chain reaction. RKI treatment increased eNOS mRNA 4-fold compared with that seen in the control group. RKI could improve cardiac function through NO-dependent endothelial protection after ischemia and reperfusion.
Analysis of RKI Activity
We added RKI to all solutions, including the cardioplegic solution, UW solution, and storage solution. However, it is unclear whether the chemical can penetrate cells at a low temperature. To evaluate the bioactivity of Rho A and Rho-kinase, phosphorylation of the
-adducin, ezrin, radixin, and moesin family and the myosin-binding subunit of myosin phosphatase, as well as expression of Rho A are usually measured. We used an anti-p-MLC antibody that is specific to MLC in the endothelium and vascular smooth muscle but not cardiomyocytes. RKI reduced p-MLC levels in the allograft for at least 2 hours after reperfusion. RKI is a vasorelaxant in the endothelium and vascular smooth muscle in vivo and in vitro.26,27
| Limitations |
|---|
|
|
|---|
Although the transition of the donor heart rate in each group after reperfusion was in direct proportion to CBF, the relationships were inversely proportional. At 60 minutes, heart rate in the RKI group decreased but was increased in the control group. We are unable to explain the reason for this difference.
Coronary vasculopathy after cardiac transplantation is an important cause of poor outcomes after cardiac transplantation, including reduced survival.28
Improvement of both endothelial and myocardial protection during allograft storage might improve early and long-term outcomes. These results might have clinical relevance for the prevention of low coronary flow phenomenon and postoperative low output syndrome induced by prolonged cardiac ischemia.
| Conclusions |
|---|
|
|
|---|
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
T. Takagi, Y. Okamoto, S. Tomita, A. Sato, S. Yamaguchi, Y. Takuwa, and G. Watanabe Intraradial administration of fasudil inhibits augmented Rho kinase activity to effectively dilate the spastic radial artery during coronary artery bypass grafting surgery J. Thorac. Cardiovasc. Surg., August 1, 2011; 142(2): e59 - e65. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Eto, N. Kajihara, S. Morita, and R. Tominaga A novel electron paramagnetic resonance spin-probe technique demonstrates the relation between the production of hydroxyl radicals and ischemia-reperfusion injury Eur J Cardiothorac Surg, April 1, 2011; 39(4): 465 - 470. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||