JTCS KCI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ando, M.
Right arrow Articles by Takahashi, Y.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Ando, M.
Right arrow Articles by Takahashi, Y.
Related Collections
Right arrow Congenital - acyanotic
Right arrow Congenital - cyanotic

J Thorac Cardiovasc Surg 2009;137:124-131
© 2009 The American Association for Thoracic Surgery


Congenital Heart Disease

Ten-year experience with handmade trileaflet polytetrafluoroethylene valved conduit used for pulmonary reconstruction

Makoto Ando, MD*, Yukihiro Takahashi, MD

Department of Pediatric Cardiac Surgery, Sakakibara Heart Institute, Tokyo, Japan

Received for publication June 16, 2008; revisions received August 11, 2008; accepted for publication August 31, 2008.

* Address for reprints: Makoto Ando, MD, Department of Pediatric Cardiac Surgery, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu-si, Tokyo 183-0003, Japan. (Email: maando{at}shi.heart.or.jp).


    Abstract
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
Objective: The objective of this study was to investigate the results of handmade polytetrafluoroethylene trileaflet conduits implanted in the pulmonary position since 1997.

Methods: One hundred thirty-nine patients underwent pulmonary reconstruction with a polytetrafluoroethylene conduit. Conduit function was investigated by means of review of serial echocardiographic studies.

Results: Mean age and body weight were 12.7 ± 12.0 years and 30.9 ± 20.6 kg. Mean size of the conduit was 21.0 ± 3.8 mm (12–28 mm). The z score of the conduit was +0.5 ± 0.8 for patients older than 15 years (n = 43), +1.2 ± 0.7 for patients 5 to 15 years old (n = 48), and +2.4 ± 0.5 for patients younger than 5 years (n = 48). Conduits were used for the Ross procedure in 21 patients and for repair of complex congenital heart disease in 118 patients. There were 3 (2.2%) in-hospital deaths and 1 late death. Four patients required conduit explantation because of pulmonary artery distortion at a distal anastomotic site (interval, 1.2 years), infection of the polytetrafluoroethylene valve (interval, 1.6 years), midportion angulation of the conduit (interval, 4.9 years), and conduit compression by the ascending aorta (interval, 5.4 years). Estimated freedom from conduit explantation was 88.0% ± 6.8%, and pulmonary insufficiency was less than or equal to mild in 75.0% at 10 years. All valves maintained their motion, and the mean estimated pressure gradient across the conduit was 19.6 ± 11.9 mm Hg at 5 years and appeared to reach a plateau thereafter. The pressure gradient across the conduit was 14.2 ± 8.0 mm Hg at 3 years (P = .0127) and 18.1 ± 7.5 mm Hg at 7 years (P = .0208).

Conclusions: Polytetrafluoroethylene conduits represent a valid option and reliable alternative to homograft and xenograft implantation for pulmonary reconstruction.



Abbreviation and Acronym PTFE = polytetrafluoroethylene



    Introduction
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 


Formula

Earn CME credits at http://cme.ctsnetjournals.org

 

Extracardiac conduits of any material used for the pulmonary artery have an inherent tendency toward late failure. Even homografts, the most widely used conduits, do not always ensure the best possible durability1,2Go because calcific fibrosis has been noted to occur, particularly in very young patients. Furthermore, homografts are not always available. For these reasons, xenografts or other synthetic conduits have been used as alternatives.

Polytetrafluoroethylene (PTFE) is chemically inert, has low friction, and possesses low tissue affinity. Therefore it is theoretically resistant to degeneration or calcification and has been used as a useful substitute for the pulmonary valve.3Go In our institute we have used Dacron conduits that incorporate a trileaflet PTFE valve for pulmonary reconstruction since 1997. The purpose of this study was to analyze the results of this particular PTFE conduit.


    Materials and Methods
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
Construction of the Conduit
For more information on construction of the conduit, see Figures 1 to 3 Go Go. A Dacron conduit (Hemashield; Boston Scientific Corp, Natick, Mass) of an appropriate size is provided first. Then a 0.1-mm PTFE membrane (Gore-Tex; W. L. Gore & Associates, Inc, Newark, Del) is cut in a rectangular shape. Six equally sized rectangular grids are drawn with a marking pen, leaving a 1-mm margin on both sides and a 2-mm margin at the top. The sheet is then folded, leaving the top margin. It is separated by suture lines, using running stitches of 6-0 polypropylene sutures to create 3 pockets, and rolled. Both sides are then sutured together to create a syringe-shaped structure with 3 separate pockets on the inside. The valve is pushed inside and fixed onto the Dacron conduit by suturing the top and bottom ends of the PTFE valve with running stitches of 5-0 polypropylene sutures. After fixing the valve, the outer layer of the PTFE valve (at the midpoint of the sinus portion of the valve) is sutured to the conduit to avoid free-floating material. Commissural sutures (1 mm distant from the commissure) are finally placed to improve valve coaptation.


Figure 1
View larger version (36K):
[in this window]
[in a new window]

 
Figure 1. Schematic drawings of the steps of conduit construction. The width of each grid on the polytetrafluoroethylene sheet (a) is determined as follows: [(Diameter of the Dacron conduit) x 1.05] in millimeters. The height of each grid (b) is determined as follows: (a x 0.8) in millimeters. The created polytetrafluoroethylene valve is fixed inside the Dacron conduit by suturing the top (1) and bottom (2) ends. After fixing the valve, each valve is sutured together at the point of a 1-mm distance from each commissure (3) to improve valve coaptation. The outer layer of the polytetrafluoroethylene valve is then sutured at the midpoint (4) to the conduit to avoid free floating.

 

Figure 2
View larger version (76K):
[in this window]
[in a new window]

 
Figure 2. Grids are drawn on the polytetrafluoroethylene sheet (A). The folded sheet is separated by suture lines to create 3 pockets (B). Both sides are then sutured together (C) to create a syringe-shaped trileaflet valve (D).

 

Figure 3
View larger version (81K):
[in this window]
[in a new window]

 
Figure 3. The valve is pushed inside (A) and fixed onto the Dacron conduit by suturing the top and bottom ends of the polytetrafluoroethylene valve (B). Commissural sutures are placed at the point of a 1-mm distance from the commissure (arrow in C). The outer layer of the polytetrafluoroethylene valve is sutured to the conduit at the midpoint of the sinus (arrow in D).

 
Implantation of the Conduit
All patients underwent a standard first-time or redo median sternotomy. Cardiopulmonary bypass was established with ascending aortic and bicaval cannulations. If present, the ventricular septal defect was first closed. After creation of the openings in the pulmonary artery and the right ventricle (left ventricle in 11 patients with corrected transposition of the great arteries), the conduit was cut to the appropriate length. The distal end of the conduit was trimmed off at approximately 0.5 to 1 cm from the distal margin of the PTFE valve. The distal anastomosis of the conduit with the pulmonary artery was first performed with a running suture. The proximal end was then trimmed to an appropriate shape, and the proximal anastomosis with the ventricle was performed with a running suture and reinforced with an autologous pericardial strip.

Echocardiographic Measurements
We collected data regarding conduit function, including the degree of pulmonary insufficiency and estimated pressure gradient across the conduit, from the echocardiographic studies performed every year after conduit implantation by our cardiologists. If flow velocity was clearly detected inside the conduit, the pressure gradient was estimated by the highest maximum flow velocity with the cursor pointed toward the direction of the conduit. There was an average of 3.4 studies per patient, with a total of 477 studies. Of these, 60 (12.6%) were not available for review. In some cases (n = 22, 4.6% of all studies) the flow velocity was not obtained inside the conduit, but the tricuspid regurgitation jet was identified. In that case the pressure gradient was estimated by using the following formula: [(Predicted right ventricular pressure from the maximal flow velocity of tricuspid regurgitation flow) – 20]. This formula assumes that the right atrial pressure was 10 mm Hg and the systolic pulmonary pressure was 30 mm Hg. Pulmonary insufficiency was graded as none to trivial, mild (regurgitation flow confined within the lumen of the conduit, central deficiency during closure of leaflets not visible), moderate (regurgitation flow extending beyond the proximal conduit–right ventricular anastomosis), and severe (massive regurgitation flow through a visible central deficiency at the time of diastole with restricted or absent leaflet motion).

Data Analysis
StatView statistical software for Windows (version 5.0; SAS Institute, Inc, Cary, NC) was used for data analysis. Values were expressed as means ± standard deviation or median. Time-dependent outcomes were assessed with Kaplan–Meir analysis, with the log-rank test used to evaluate group differences. All probability values were 2-tailed. Locally weighted polynomial (Lowess) regression line was drawn based on a weighted linear least squares regression over the span of values of the y-axis scattergram criterion variable.

The study was approved by the Institutional Review Board of Sakakibara Heart Institute, and the procedures were in accordance with institutional guidelines for protection of patient confidentiality. The need for patient consent was waived.


    Results
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
Basic Demographic Information
One hundred thirty-nine patients underwent pulmonary reconstruction with the PTFE conduit. Follow-up was complete in 127 (91.4%) of 139 patients as of November 2007. The mean follow-up period was 2.7 ± 2.4 years. There were 55 female patients. Mean age and body weight at the time of the operation were 12.7 ± 12.0 years (0.07–62.5 years) and 30.9 ± 20.6 kg (3.4–101 kg), respectively.

Anatomic diagnosis and surgical status are listed in Table 1 . Conduits were placed from the left ventricle to the pulmonary artery in 11 patients (conventional Rastelli procedure) and from the right ventricle to the pulmonary artery in 4 (double-switch operation) for patients with corrected transposition of the great arteries, ventricular septal defect, and left ventricular outflow tract obstruction. Four patients with ventricular septal defect, left ventricular outflow tract obstruction, and well-developed ventricles underwent conduit replacement after former Norwood-type arch repair and biventricular repair.


View this table:
[in this window]
[in a new window]

 
Table 1 Anatomic diagnosis and operative status
 
Preexisting cardiac problems included severe hypoplasia or discontinuous branch pulmonary arteries in 8 patients, severe hypoplasia or complete absence of the right or left pulmonary artery in 5 patients, complete atrioventricular block requiring pacemaker implantation in 3 patients, residual ventricular septal defect after previous repair in 2 patients, severe tricuspid regurgitation in 2 patients, and ventricular tachyarrhythmia in 1 patient.

First-time complete repair (Rastelli procedure) was performed in 58 (41.7%) patients, and a nonreoperative Ross procedure was performed in 19 (13.7%) patients. Forty-one (29.5%) patients underwent conduit replacement after previous Rastelli or Ross procedures, and 21 (15.1%) patients underwent conduit placement after previous intracardiac repair by using right ventricular outflow reconstruction.

One patient with complete transposition of the great arteries, ventricular septal defect, and left ventricular outflow tract obstruction had undergone a palliative Senning operation previously. This patient underwent takedown of the Senning baffle, closure of the ventricular septal defect, and morphologic left ventricle–pulmonary artery conduit placement. Other concomitant procedures included tricuspid repair or replacement in 11 patients, extended pulmonary arterial plasty in 7 patients, mitral valve plasty or replacement in 3 patients, aortic valve plasty or replacement in 3 patients, resection of subaortic stenosis in 2 patients, pulmonary unifocalization in 2 patients, the Senning procedure (double switch) in 2 patients, and pacemaker implantation in 1 patient.

The size of the conduit used was 12 mm in 2 patients, 14 mm in 4 patients, 16 mm in 20 patients, 18 mm in 22 patients, 20 mm in 16 patients, 22 mm in 26 patients, 24 mm in 24 patients, 26 mm in 24 patients, and 28 mm in 1 patient, with a mean conduit size of 21.0 ± 3.8 mm (12–28 mm). The z score of the conduit was +0.5 ± 0.8 for patients older than 15 years (n = 43), +1.2 ± 0.7 for those 5 to 15 years of age (n = 48), and +2.4 ± 0.5 for patients younger than 5 years (n = 48).

Operative and Late Mortality
There were 3 (2.2%) in-hospital deaths and 1 late death.

The first patient, who underwent the Ross procedure for congenital aortic stenosis, had severe left ventricular dysfunction after the operation. Despite maximal effort to resuscitate the ventricle, the patient died on the first day after the operation. This death was thought to be attributable to the imperfect myocardial protection in the setting of severe left ventricular hypertrophy.

The second patient underwent an operation for repair of ventricular septal defect and pulmonary atresia. After weaning from cardiopulmonary bypass, multiple communications between both ventricles were found. Unsuccessful attempts were made to close these additional defects. The patient had severe cardiac dysfunction and died on the day after the operation.

The third patient, with a ventricular septal defect and pulmonary atresia, underwent an uneventful operation, and the postoperative course in the intensive care unit was also uneventful. After transfer to the ward, the patient had sudden respiratory arrest followed by cardiac arrest. Despite resuscitation, the patient died on day 2 from the operation. The cause of death was not identified.

The fourth patient, with a diagnosis of ventricular septal defect and pulmonary atresia, had undergone bilateral systemic–pulmonary artery shunts before complete repair. The distortion of both pulmonary arterial branches at the site of shunt anastomosis was not successfully relieved and resulted in a high right ventricular pressure with severe dysfunction. This patient died of heart failure at 9.5 months.

Other Postoperative Complications
One patient, who underwent the Ross operation, had sudden cardiac arrest on the day of the operation, presumably because of imperfect myocardial protection during the operation. The patient subsequently recovered, and the remainder of the hospital course was uneventful.

Other postoperative complications included prolonged pleural effusion requiring chest tube placement for 7 days or longer in 5 patients, atrial fibrillation requiring cardioversion in 2 patients, sternotomy wound infection in 2 patients, phrenic nerve paralysis in 2 patients, protein losing enteropathy (present before the operation) in 1 patient, ventricular tachyarrhythmia requiring cardioverter defibrillator implantation in 1 patient, reoperation for bleeding in 1 patient, and complete atrioventricular block requiring pacemaker insertion in 1 patient.

Conduit Explantation
Thirty-one patients underwent a follow-up catheterization after the operation. Indications included suspected pulmonary stenosis in 6 patients, potential intervention for residual branch pulmonary stenosis in 6 patients (for whom angioplasty was done in 2 patients), aortic regurgitation in 3 patients, and decreased left ventricular function in 2 patients. In the other 14 patients, catheterization was performed to generally assess cardiac performance with no suspected abnormality. Among them, conduit stenosis requiring replacement was found in 4 patients.

The first patient had pulmonary artery distortion at the distal conduit–pulmonary artery anastomosis. This patient also had a residual ventricular septal defect and a patent systemic–pulmonary artery shunt. This patient underwent closures of the residual ventricular septal defect and systemic–pulmonary artery shunt and replacement of the pulmonary conduit at 1.2 years.

The second patient had also pulmonary artery distortion at the distal conduit–pulmonary artery anastomotic site, as well as a midportion angulation requiring conduit replacement at 4.9 years.

The third patient had pseudoaneurysm at the proximal suture line of the autograft after a Ross procedure. This caused an extrinsic compression of the pulmonary conduit and stenosis. The patient required repair of the pseudoaneurysm and pulmonary conduit replacement at 5.4 years.

The fourth patient, with a ventricular septal defect and pulmonary atresia, underwent conduit replacement with a PTFE conduit. The patient had previously experienced episodes of ventricular tachycardia, which exacerbated after the operation. The patient received implantable cardioverter defibrillator, resulting in the lead infection. After removal of the defibrillator, the patient manifested persistent staphylococcal bacteremia, resulting in infection of the PTFE valve. The patient eventually required replacement of this conduit at 1.6 years.

Estimated freedom from conduit replacement was 97.8% ± 1.6% at 3 years, 93.5% ± 4.4% at 5 years, and 88.0% ± 6.8% at 10 years.

Other Reoperations not Requiring Conduit Explantation
Two patients with ventricular septal defect and pulmonary atresia required aortic valve replacement for progressive aortic valve insufficiency at 1.9 and 7.6 years, respectively. The third patient underwent one and a half ventricle repair for pulmonary atresia with intact ventricular septum. The patient had right heart failure because of the hypoplastic right ventricle and required creation of the atrial septal defect at 4.6 months. The fourth patient, with aortic atresia and a ventricular septal defect, had ascending aortic stenosis and underwent aortoplasty at 1.5 months. Pulmonary conduits were considered to be intact in these patients and were not replaced.

Conduit Function on Echocardiographic Analysis
The mean estimated pressure gradient across the conduit was 9.4 ± 6.5 mm Hg immediately after the operation, 14.2 ± 8.0 mm Hg at 3 years, and 19.6 ± 11.9 mm Hg at 5 years and appeared to reach a plateau thereafter (Figure 4 ). When divided by the size of the conduit, the mean pressure gradient of a conduit of greater than 20 mm reached a plateau at 5 years and remained within 20 mm Hg until 10 years. The mean pressure gradient, however, reached 20 mm Hg at 4 years for a conduit size of 16 to 18 mm and at 2 years for 12 to 14 mm (Figure 5 ). When analyzed by the different procedures performed, conduits used in the Ross procedure, in right ventricle–pulmonary artery reconstruction in the heart with normally related great arterial relationship, and for left ventricle–pulmonary artery reconstruction exhibited similar gradients. On the contrary, the mean pressure gradient increased exponentially in the right ventricle–pulmonary artery conduit in hearts with transposition of the great arteries (Figure 6 ). All valves maintained their motion, and pulmonary insufficiency was less than or equal to mild in 75.0% at 10 years (Figure 7 ).


Figure 4
View larger version (9K):
[in this window]
[in a new window]

 
Figure 4. Scatterplots of estimated pressure gradient across the conduit for the polytetrafluoroethylene valved conduit as a function of time interval after the procedure. The markers indicate the mean pressure gradient, and bars indicate the standard deviations. The solid lines were derived by the locally weighted polynomial (Lowess) regression of the data. Numbers in parentheses indicate patients at risk.

 

Figure 5
View larger version (9K):
[in this window]
[in a new window]

 
Figure 5. Scatterplots of estimated pressure gradient across the conduit as a function of time interval after the procedure. The markers indicate the mean pressure gradient for the conduit sized greater than 20 mm (solid circles), 16 or 18 mm (open circles), and 12 or 14 mm (solid squares). The solid lines were derived by the locally weighted polynomial (Lowess) regression of the data. Numbers in parentheses indicate patients at risk for conduit size 12/14 mm (top row), 16/18 mm (middle row), and greater than 20 mm (bottom row).

 

Figure 6
View larger version (12K):
[in this window]
[in a new window]

 
Figure 6. Scatterplots of estimated pressure gradient across the conduit as a function of time interval after the procedure. The markers indicate the mean pressure gradient for the conduit placed from the right ventricle to the pulmonary artery in patients having transposition of the great arteries (RV-PA TGA, open squares), from the right ventricle to the pulmonary artery in patients undergoing the Ross procedure (open circles), from the right ventricle to the pulmonary artery in patients with normally related great arteries (RV-PA NGA, solid squares), and from the left ventricle to the pulmonary artery in patients having corrected transposition of the great arteries (LV-PA, solid circles). The solid lines were derived by the locally weighted polynomial (Lowess) regression of the data. Numbers in parentheses indicate patients at risk for RV-PA NGA, Ross, RV-PA TGA, and LV-PA (top to bottom rows).

 

Figure 7
View larger version (23K):
[in this window]
[in a new window]

 
Figure 7. Progression of pulmonary regurgitation until 10 years after the operation. Numbers in parentheses indicate patients at risk.

 
Histological Findings on the Explanted Specimen
For more information on histologic findings on the explanted specimen, see Figure 8 .


Figure 8
View larger version (95K):
[in this window]
[in a new window]

 
Figure 8. Polytetrafluoroethylene valve specimens explanted at 5.4 years after implantation (top). Microscopic image of the same specimen stained with Milligan's trichrome stain (bottom). (Original magnitude 20x.)

 
In the PTFE valve specimen of the explanted conduit at 5.4 years, the surface of the valve was smooth, and the valve itself was pliable. On microscopic evaluation, there was no structural deterioration of the PTFE membrane, cellular infiltration, or calcification noted.


    Discussion
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
The extracardiac conduit placed in the pulmonary position is almost always subject to functional deterioration. Even homografts, the most widely used material for pulmonary reconstruction, are not exempt from failure, and replacement might become mandatory at some point in the patient's life.

In general, results of homografts used for pulmonary reconstruction in the Ross procedure have been excellent, with reported freedom from reintervention of greater than 90% at 5 years.4Go In the non-Ross population, however, some report poor performance of homografts.1Go According to another report, somatic outgrowth is seldom a primary reason for homograft conduit replacement, but rather conduit obstruction with thickening and shrinkage at the annular area is more frequently responsible for failure.5Go Especially when aortic homografts are used in young patients, accelerated aortic homograft fibrocalcification can occur. Blood group incompatibility between receiver and homograft donor also seems to play an important role in the development of accelerated fibrocalcifications in cryopreserved homografts.6Go Some even report the inferior longevity of homografts when compared with porcine valved Dacron conduits.1Go

Commercially available glutaraldehyde-preserved xenograft pericardial valved conduits (Hancock valved conduit, Medtronic, Minneapolis, Minn; Carpentier–Edwards valved conduit, Edwards Lifesciences, Irvine, Calif) have been widely used since the 1970s. These conduits are known to be associated with a disturbing incidence of late failure,7,8Go with 1 report showing a total incidence of 30% xenograft conduit failure in a 6-year follow-up.9Go More recently, a xenograft valved conduit using a decalcification process to mitigate tissue degeneration and calcification associated with glutaraldehyde (Shelhigh conduit; Shelhigh, Inc, Union, NJ) has become commercially available.10Go This conduit, however, was also associated with a high incidence of early failure caused by pseudointimal peel formation that led to multilevel conduit stenosis.11,12Go

Glutaraldehyde-preserved bovine jugular vein (Contegra; Medtronic, Inc) conduits are now considered a sound alternative to homografts for pulmonary reconstruction, with reported freedom from graft dysfunction and reoperation of greater than 90% at 7 years postoperatively.13Go This particular conduit might be especially useful for right ventricular outflow tract reconstruction in neonates and infants.14Go However, distal conduit stenosis is frequently seen among younger patients and patients with small pulmonary arteries. Also, significant graft dilatation was observed in patients with pulmonary artery branch obstruction or pulmonary hypertension.15Go Some advocate cautious use of these conduits in patients with predicted high right ventricular/left ventricular pressure ratios.16Go

PTFE has very low tissue affinity. Because of this property, cellular or fibrinous deposition is unlikely, and for these reasons, it is the most reliable material for small-caliber vascular grafts.17Go Moreover, because of its chemical inertness, tissue degeneration or destruction is unlikely or very slow to progress. These properties make PTFE an ideal biomaterial for valve replacement, especially in the pulmonary position. Brown and colleagues3Go reported excellent results with right ventricular outflow tract reconstruction by using a PTFE monocusp valve. They did not witness significant calcification or pulmonary embolization, and the only antithrombotic agent used was low-dose aspirin. According to our results, PTFE conduits have comparable longevity when used in the pulmonary position when compared with the reported results of blood-compatible homografts or Contegra conduits, particularly with respect to larger-sized conduits. In some countries, such as Japan, the access to homografts or xenograft products of Western countries (ie, Contegra) is limited. The PTFE conduit is inexpensive and always available and therefore could be the conduit of choice in these circumstances. Even in Western countries, homografts are not always available in an ideal size. In this context the PTFE conduit might be a good choice, especially if the patient has a high pulmonary artery pressure, for which the Contegra conduit might not be an optimal choice. The follow-up of smaller-sized PTFE conduits is currently limited, with the longest observation period of the smallest size (12 mm) being only 1.5 years. Longer follow-up is required to assess the performance of the smaller-sized PTFE conduit to extrapolate meaningful comparative data with homografts and Contegra conduits.

Another group reported the results of handmade trileaflet conduits made of heterologous pericardium or PTFE for right ventricular outflow tract reconstruction.18Go The reported freedom from important pulmonary valve regurgitation was 68.3% ± 3.7% at 5 years, 33.0% ± 4.5% at 10 years, and 21.6% ± 4.9% at 15 years. Conduits included whole heterologous pericardial trileaflet conduits in 169 patients and bovine pericardial conduits containing PTFE leaflets in 26 patients. Whole PTFE trileaflet rolls were used in only 21 patients. It is important to note that when materials with different tissue affinities are sutured together, tissue pannus might form at the junction. An example of this is the intimal peel formation leading to valve dysfunction observed in xenograft valved Dacron conduits.19Go Because PTFE has very low tissue affinity, intimal or pseudointimal ingrowths from the adjacent tissue can easily be peeled off and form a pannus. If the PTFE valve is directly sutured to the heterogenous substance, such as xenograft pericardium, a similar phenomenon can occur, which can lead to valve dysfunction. Therefore it is especially important that the outer wall of the PTFE valve leaflet (sinus portion) should be a PTFE substance. To achieve this, one can suture the PTFE membrane directly to the PTFE conduit.20Go It is also possible to fold the PTFE membrane before suturing it inside the outer conduit, as we presently do. We prefer to use a Hemashield conduit (St Jude Medical, St Paul, Minn) for several reasons, including the ease of hemostasis, the stiffness of the conduit (making itself resistant to external compression), and its inherent structure, which is resistant to angulation. It should be also noted that the PTFE membrane is folded, leaving a few millimeters excess at the top end, which gives some space between the suture line with the Dacron conduit and the sinus of each valve. We believe the pannus, even if formed, can be peeled off before it intrudes into the sinus, preserving the function of the valve.

Our results confirmed that the long-term results of the Rastelli operation for management of patients with transposition of the great arteries, ventricular septal defect, and pulmonary stenosis are still somewhat suboptimal. Aortic translocation and biventricular outflow tract reconstruction might be an alternative for the management of these patients to reduce postoperative right ventricular outflow tract failure.21Go

Conduits are routinely oversized to account for somatic growth in children requiring right ventricle–pulmonary artery continuity. However, there is an increasing awareness of the fact that excessive oversizing of the conduit placed in the pulmonary position results in decreased longevity in children.22Go Pulmonary conduit durability and hemodynamic function in patients undergoing initial conduit insertion at less than 2 years of age can be improved by using pulmonary conduits with z scores between +1 and +3.23Go The target z score of the conduit in our cohort was +2 in the small children aged less than 5 years, +1 for those aged 5 to 15 years, and the normal size for those aged 15 years or older.

The distal end of the conduit was cut off, leaving only a 1/2- to 1-cm margin from the top end of the PTFE valve. Because the conduit usually forms an acute-angled curve after arising from the ventricle to be oriented toward the pulmonary artery, positioning of the valve renders itself to distortion. This technique allows the valve to be positioned in the straight portion of the conduit, leading to the maintenance of its intact shape.

The limitations to this study include the retrospective nature of the study design and that echocardiograms had been obtained by one of our 7 attending cardiologists. Therefore each study might be highly subjective to the bias of each investigator.

In summary, PTFE valved conduits showed acceptable functional durability and maintained valve motion for up to 10 years in all patients in this series. As is shown in this study, late valve fixation in the semiopen position did not occur. Because of this, development of the pressure gradient reached a plateau in conduits with a size of greater than 20 mm, and there was no reoperation because of structural deterioration during this time period. In our opinion PTFE conduits represent a valid option and a reliable alternative to homograft and xenograft implantation for pulmonary reconstruction.


    Footnotes
 
Read at the Thirty-fourth Annual Meeting of the Western Thoracic Surgical Association, Kona, Hawaii, June 25–28, 2008.


    References
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 

  1. Brown JW, Ruzmetov M, Rodefeld, MD, Vijay P, Turrentine MW. Right ventricular outflow tract reconstruction with an allograft conduit in non-Ross patients: risk factors for allograft dysfunction and failure. Ann Thorac Surg 2005;80:655-663.[Abstract/Free Full Text]
  2. Dearani JA, Danielson GK, Puga FJ, Schaff HV, Warnes CW, Driscoll DJ, et al. Late follow-up of 1095 patients undergoing operation for complex congenital heart disease utilizing pulmonary ventricle to pulmonary artery conduits. Ann Thorac Surg 2003;75:399-410.[Abstract/Free Full Text]
  3. Brown JW, Ruzmetov M, Vijay P, Rodefeld, MD, Turrentine MW. Right ventricular outflow tract reconstruction with a polytetrafluoroethylene monocusp valve: a twelve-year experience. J Thorac Cardiovasc Surg 2007;133:1336-1343.[Abstract/Free Full Text]
  4. Selamet Tierney ES, Gersony WM, Altmann K, Solowiejczyk DE, Bevilacqua LM, Khan C, et al. Pulmonary position cryopreserved homografts: durability in pediatric Ross and non-Ross patients. J Thorac Cardiovasc Surg 2005;130:282-286.[Abstract/Free Full Text]
  5. Wells WJ, Arroyo Jr. H, Bremner RM, Wood J, Starnes VA. Homograft conduit failure in infants is not due to somatic outgrowth. J Thorac Cardiovasc Surg 2002;124:88-96.[Abstract/Free Full Text]
  6. Christenson JT, Vala D, Sierra J, Beghetti M, Kalangos A. Blood group incompatibility and accelerated homograft fibrocalcifications. J Thorac Cardiovasc Surg 2004;127:242-250.[Abstract/Free Full Text]
  7. Stewart S, Manning J, Alexson C, Harris P. The Hancock external valved conduit. A dichotomy between late clinical results and late cardiac catheterization findings. J Thorac Cardiovasc Surg 1983;86:562-569.[Abstract]
  8. Butany J, Luk A, Leong SW, Leong MM, Singh G, Thangaroopan M, et al. A Carpentier-Edwards porcine-valved Dacron conduit: at twenty-five years. Int J Cardiol 2007;117:e13-e16.[Medline]
  9. Bisset 3rd GS, Schwartz DC, Benzing 3rd G, Helmsworth J, Schreiber JT, Kaplan S. Late results of reconstruction of the right ventricular outflow tract with porcine xenografts in children. Ann Thorac Surg 1981;31:437-443.[Abstract/Free Full Text]
  10. Marianeschi SM, Iacona GM, Seddio F, Abella RF, Condoluci C, Cipriani A, et al. Shelhigh No-React porcine pulmonic valve conduit: a new alternative to the homograft. Ann Thorac Surg 2001;71:619-623.[Abstract/Free Full Text]
  11. Schreiber C, Sassen S, Kostolny M, Hörer J, Cleuziou J, Wottke M, et al. Early graft failure of small-sized porcine valved conduits in reconstruction of the right ventricular outflow tract. Ann Thorac Surg 2006;82:179-185.[Abstract/Free Full Text]
  12. Kim WH, Min SK, Choi CH, Lee JR, Kim YJ, Bae EJ, et al. Follow-up of Shelhigh porcine pulmonic valve conduits. Ann Thorac Surg 2007;84:2047-2050.[Abstract/Free Full Text]
  13. Sierra J, Christenson JT, Lahlaidi NH, Beghetti M, Kalangos A. Right ventricular outflow tract reconstruction: what conduit to use? Homograft or Contegra?. Ann Thorac Surg 2007;84:606-610.[Abstract/Free Full Text]
  14. Sinzobahamvya N, Asfour B, Boscheinen M, Photiadis J, Fink C, Schindler E, et al. Compared fate of small-diameter Contegras and homografts in the pulmonary position. Eur J Cardiothorac Surg 2007;32:209-214.[Abstract/Free Full Text]
  15. Sekarski N, van Meir H, Rijlaarsdam ME, Schoof PH, Koolbergen DR, Hruda J, et al. Right ventricular outflow tract reconstruction with the bovine jugular vein graft: 5 years' experience with 133 patients. Ann Thorac Surg 2007;84:599-605.[Abstract/Free Full Text]
  16. Shebani SO, McGuirk S, Baghai M, Stickley J, De Giovanni JV, Bu'lock FA, et al. Right ventricular outflow tract reconstruction using Contegra valved conduit: natural history and conduit performance under pressure. Eur J Cardiothorac Surg 2006;29:397-405.[Abstract/Free Full Text]
  17. Donahoo JS, Gardner TJ, Zahka K, Kidd BS. Systemic-Pulmonary shunts in neonates and infants using microporous expanded polytetrafluoroethylene: immediate and late results. Ann Thorac Surg 1980;30:146-150.[Abstract/Free Full Text]
  18. Koh M, Yagihara T, Uemura H, Kagisaki K, Hagino I, Ishizaka T, et al. Long-term outcome of right ventricular outflow tract reconstruction using a handmade tri-leaflet conduit. Eur J Cardiothorac Surg 2005;27:807-814.[Abstract/Free Full Text]
  19. Chun PK, Rocchini AP, Gibbs HR, Robinowitz M, Green D, Virmani R. Pannus formation in a Hancock-valved conduit resulting in proximal intraconduit obstruction: late complication of Rastelli procedure for complete transposition of the great vessels with ventricular septal defect and pulmonic stenosis. Am Heart J 1981;101:855-857.[Medline]
  20. Miyazaki T, Yamagishi M, Nakashima A, Fukae K, Nakano T, Yaku H, et al. Expanded polytetrafluoroethylene valved conduit and patch with bulging sinuses in right ventricular outflow tract reconstruction. J Thorac Cardiovasc Surg 2007;134:327-332.[Abstract/Free Full Text]
  21. Morell VO, Jacobs JP, Quintessenza JA. Aortic translocation in the management of transposition of the great arteries with ventricular septal defect and pulmonary stenosis: results and follow-up. Ann Thorac Surg 2005;79:2089-2092.[Abstract/Free Full Text]
  22. Askovich B, Hawkins JA, Sower CT, Minich LL, Tani LY, Stoddard G, et al. Right ventricle-to-pulmonary artery conduit longevity: is it related to allograft size?. Ann Thorac Surg 2007;84:907-911.[Abstract/Free Full Text]
  23. Karamlou T, Blackstone EH, Hawkins JA, Jacobs ML, Kanter KR, Brown JW, et al. Can pulmonary conduit dysfunction and failure be reduced in infants and children less than age 2 years at initial implantation?. J Thorac Cardiovasc Surg 2006;132:829-838.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Eur J Cardiothorac SurgHome page
M. Nosal', R. Poruban, P. Valentik, M. Sagat, A. S. Nagi, and A. Kantorova
Initial experience with polytetrafluoroethylene leaflet extensions for aortic valve repair
Eur J Cardiothorac Surg, January 12, 2012; (2012) ezr214v1.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Miyazaki, M. Yamagishi, Y. Maeda, Y. Yamamoto, S. Taniguchi, Y. Sasaki, and H. Yaku
Expanded polytetrafluoroethylene conduits and patches with bulging sinuses and fan-shaped valves in right ventricular outflow tract reconstruction: Multicenter study in Japan
J. Thorac. Cardiovasc. Surg., November 1, 2011; 142(5): 1122 - 1129.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. J. Russo, R. Easterwood, M. R. Williams, I. George, and A. S. Stewart
Aortic Root and Right Ventricular Outflow Tract Reconstruction Using Composite Biological Valved Conduits After Failed Ross Procedure
Ann. Thorac. Surg., June 1, 2011; 91(6): e87 - e89.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Yoshida, P. D. Wearden, O. Dur, K. Pekkan, and V. O. Morell
Right Ventricular Outflow Tract Reconstruction With Bicuspid Valved Polytetrafluoroethylene Conduit
Ann. Thorac. Surg., April 1, 2011; 91(4): 1235 - 1239.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
I. George, J. N. Shah, M. Bacchetta, and A. Stewart
Stentless Bioprosthesis in a Valved Conduit: Implications for Pulmonary Reconstruction
Ann. Thorac. Surg., December 1, 2009; 88(6): 2022 - 2024.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ando, M.
Right arrow Articles by Takahashi, Y.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Ando, M.
Right arrow Articles by Takahashi, Y.
Related Collections
Right arrow Congenital - acyanotic
Right arrow Congenital - cyanotic


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS