|
|
||||||||
J Thorac Cardiovasc Surg 2009;137:198-207
© 2009 The American Association for Thoracic Surgery
Cardiopulmonary Support and Physiology |
Heart Research Laboratory, Department of Physiology and Pharmacology, James Cook University, Townsville, Queensland, Australia
Received for publication February 23, 2008; revisions received May 21, 2008; accepted for publication June 15, 2008. * Address for reprints: Geoffrey P. Dobson, PhD, Heart Research Laboratory, Department of Physiology and Pharmacology, James Cook University, Townsville, Queensland, Australia 4811. (Email: geoffrey.dobson{at}jcu.edu.au).
| Abstract |
|---|
|
|
|---|
Methods: Isolated perfused rat hearts (n = 87) were switched from working to Langendorff (nonworking) mode and arrested at 37°C with 200-µmol/L adenosine and 500-µmol/L lidocaine in Krebs–Henseleit buffer (10-mmol/L glucose, pH 7.7, 37°C) or with Celsior (Sangstat Medical Corp, Fremont, CA). Hearts were removed and placed in static storage at 4°C for 2 and 6 hours or remained on the apparatus and were intermittently flushed at 37°C every 20 minutes for 2 minutes at 68 mm Hg (average arrest temperature 28°–30°C) for 2 and 6 hours. We further investigated the effect of the warmer adenosine–lidocaine solution supplemented with 1- or 5-mmol/L pyruvate.
Results: Adenosine–lidocaine solution arrested hearts in 16 ± 2 seconds (n = 32), whereas Celsior did so in 39 ± 4 seconds (n = 23). After 2 hours of cold static storage, there were no functional differences between the adenosine–lidocaine and Celsior groups, with approximately 70% return of cardiac output. In contrast, after 6 hours of 4°C storage, adenosine–lidocaine hearts had significantly higher functional recoveries (68% ± 5% cardiac output) than Celsior hearts (47% ± 14% cardiac output) during 60 minutes of reperfusion. In addition, Celsior hearts took 5 minutes longer to reanimate and showed early reperfusion arrhythmias. At warmer temperatures after 2 hours of arrest, adenosine–lidocaine and Celsior hearts were not significantly different, despite a 43% higher cardiac output in adenosine–lidocaine hearts (80% ± 3% vs 56% ± 12%). After 6 hours, adenosine–lidocaine hearts had recovered 55% ± 3% of prearrest cardiac output, which increased significantly to 75% ± 4% with addition of 1-mmol/L pyruvate. Adenosine–lidocaine with 1-mmol/L pyruvate hearts spontaneously recovered 106% heart rate, 93% to 105% developed pressures, 70% aortic flow, and 81% coronary flow. Coronary vascular resistance increased 1.7- to 1.9-fold during the 6-hour arrest. In contrast, Celsior hearts did not have return of aortic or coronary flow after 6 hours in these warmer conditions.
Conclusion: A new nondepolarizing, normokalemic adenosine–lidocaine arrest solution in Krebs–Henseleit buffer with 10-mmol/L glucose was versatile at both 4°C and 28°C to 30°C relative to Celsior, and the addition of 1-mmol/L pyruvate significantly improved cardiac output at warmer arrest temperatures. This new arrest paradigm may be useful in the harvest, storage, and implantation of donor hearts.
| Introduction |
|---|
|
|
|---|
For more than 10 years, our laboratory has focused on developing a normokalemic nondepolarizing cardioplegia that clamps the membrane potential closer to its resting voltage of –83 mV by using an adenosine–lidocaine combination (AL) as the active arrest composition.17
Our innovation borrows from natural hibernators and places the heart in a more "natural" state of suspended animation.18
We have shown that the AL cardioplegia can arrest the heart for as long as 4 hours with 70% to 80% recovery of the cardiac output; 85% to 100% recovery of heart rate, systolic pressure, and rate–pressure product, and 70% to 80% of baseline coronary flows. Only 14% of hearts arrested with St Thomas' Hospital solution No. 2 survived after 4 hours.17
We have also recently demonstrated proof of concept in the canine model of cardiopulmonary bypass.19
Our aims in this study were to compare cold AL cardioplegia with AL at warmer temperatures, to compare AL with Celsior preservation solution in both states, and to test the effect of adding 1- and 5-mmol/L L-pyruvate to the AL solution at the warmer arrest temperatures. We found that AL solution is versatile at both 4°C and 28°C to 30°C and that the addition of 1-mmol/L pyruvate significantly improves cardiac output at warmer arrest temperatures. Celsior solution showed equivalence at 2 hours of arrest but failed to return aortic flow after 6 hours of arrest at 28°C to 30°C. Our new AL arrest paradigm may find utility in the harvest, ex vivo storage, and implantation of donor hearts at hypothermic to warmer temperatures.
| Materials and Methods |
|---|
|
|
|---|
Compositions of Buffers and Arrest Solutions
Krebs–Henseleit perfusion buffer
Hearts were perfused in the Langendorff and working modes with a modified Krebs–Henseleit buffer containing 10-mmol/L glucose, 117 mmol/L sodium chloride, 5.9-mmol/L potassium chloride, 25-mmol/L sodium hydrogen carbonate, 1.2-mmol/L sodium dihydrogenphosphate, 1.12-mmol/L calcium chloride (1.07-mmol/L free calcium ion), and 0.512-mmol/L magnesium chloride (0.5-mmol/L free magnesium ion), pH 7.4, at 37°C. The perfusion buffer was filtered with a 1-µm membrane and then bubbled vigorously with 95% oxygen and 5% carbon dioxide to achieve a PO
2 greater than 600 mm Hg. The perfusion buffer was not recirculated.
Arrest solutions
The AL solution was made fresh daily and contained 200-µmmol/L adenosine plus 500-µmol/L lidocaine in 10-mmol/L glucose-containing Krebs–Henseleit buffer (pH 7.7 at 37°C), as described by Dobson and Jones.17
The AL arrest solution was filtered with 0.2-µm filters and maintained at 37°C. The arrest solution was not actively bubbled with 95% oxygen and 5% carbon dioxide, leading to a higher pH. The average PO
2 of the AL solution was 131 mm Hg, and the PCO
2 was 5 to 10 mm Hg. The Celsior solution was made fresh daily and contained 100-mmol/L sodium hydroxide, 15-mmol/L potassium chloride, 13-mmol/L magnesium chloride, 0.25-mmol/L calcium chloride, 20-mmol/L glutamic acid, 80-mmol/L lactobionic acid, 30-mmol/L histidine, and 3-mmmol/L glutathione (pH 7.3). The solution was filtered with a 0.2-µm filter, was not actively bubbled with 95% and 5% carbon dioxide, and had an average PO
2 of 127.4 mm Hg.
Experimental Groups
Rats were randomly assigned to 1 of 6 arrest and storage protocols for either 2 or 6 hours: (1) AL alone for cold (4°C) static storage (n = 16), (2) AL alone with warmer (28°C–30°C) intermittent infusions (n = 16), (3) AL plus 1-mmol/L pyruvate with warmer (28°C–30°C) intermittent infusions (n = 16), (4) AL plus 5-mmol/L pyruvate with warmer 28°C–30°C intermittent infusions (n = 16), (5) Celsior for cold (4°C) static storage (n = 11), and (6) Celsior with warmer (28°C–30°C) intermittent infusions (n = 12). Although Celsior is an extracellular-type solution not originally designed for warmer temperatures, the last protocol was included for comparison with AL cardioplegia, because Celsior was designed in part to reduce injury to the heart in the transition from cold to warm reperfusion.20
Langendorff and Working Rat Heart Preparations
Hearts were rapidly removed from anesthetized rats and immediately placed in ice-cold Krebs–Henseleit buffer. Briefly, excess tissue was removed, and the heart was connected by the aorta to a standard Langendorff apparatus and perfused in a retrograde fashion with a perfusion pressure of 90 cm H2O (68 mm Hg). After the pulmonary veins and superior and inferior venae cavae were tied off to minimize leaks (<1 mL/min), the pulmonary artery was cannulated for collection of coronary venous effluent. A small incision was made in the left atrial appendage, into which another cannula was inserted and tied off for working mode operation. The preparation was then switched to the working mode by switching the supply of perfusate from the aorta to the left atrial cannula at a hydrostatic pressure of 10 cm H2O (preload) and an afterload of 100 cm H2O (76 mm Hg). The heart was deliberately not placed in a thermostat-equipped jacket, so that moderate decreases in temperature during arrest would mimic the clinical drift in myocardial temperature. Hearts were stabilized for 15 minutes before conversion back to Langendorff nonworking mode before induction of arrest. Heart rate, aortic pressure, coronary flow, and aortic flow were measured before, during, and after arrest.
Aortic pressure was measured continuously with a pressure transducer (ADI Instruments, Sydney, NSW, Australia) coupled to a MacLab 2e (ADI Instruments). Systolic and diastolic pressures and heart rate were calculated from the pressure trace with the MacLab software. Arterial and venous perfusate PO
2 and PCO
2, pH, and ionic (calcium, chloride, and sodium) concentrations were measured with a Bayer 865 blood gas machine (Siemens Australia, Bayswater, Victoria, Australia). Coronary flow and aortic flow were measured in volumetric cylinders. The initial criteria for exclusion of working hearts during the 15-minute equilibration period were a heart rate less than 200 beats/min, a systolic pressure less than 100 mm Hg, and a coronary flow less than 10 mL/min. Neither pacing nor cardiac massage was used during the reanimation phase in the working mode. The surface temperature of the heart was measured with a Cole-Parmer thermistor-thermometer (8402-20; Cole-Parmer, Vernon Hills, Ill) with the thermistor probe tucked under the left auricle. We previously have shown that placement in the left heart chamber yields similar profiles to subauricular placement.17
The perfusion apparatus was flushed weekly with 5 L of 3% hydrogen peroxide and 1% glacial acetic acid solution, followed by a thorough rinse with 10 L 18-M
water.
Cold Static Storage (4°C)
We used the cold static storage method of McDonald and colleagues21
with the following modifications. Baseline data were obtained for hearts in working mode at 37°C. Arrest was induced in the Langendorff mode at normothermia with a 5-minute infusion of cardioplegia solution (50–100 mL) through the aorta at a constant pressure of 68 mm Hg. Hearts were then gently removed from the working heart apparatus, placed in 50-mL tubes containing their respective preservation solutions, and immersed in the water bath set at 4°C for 2 or 6 hours. After storage, the hearts were returned to the perfusion apparatus, and fresh arrest solutions were perfused in Langendorff mode. The hearts were slowly rewarmed for 5 minutes before reanimation and reperfusion in working mode for 60 minutes at 37°C with oxygenated, glucose-containing Krebs–Henseleit solution at pH 7.4. Functional data (aortic and coronary flows, heart rate, and systolic and diastolic pressures) were measured at predetermined times before arrest and during 60 minutes of reperfusion and compared with the baseline data for each heart.
Intermittent Cardioplegic Delivery at Warmer Arrest Temperatures (28°C–30°C)
The method of intermittent cardioplegic delivery in the isolated rat heart has been previously described by Dobson and Jones.17
Arrest in the Langendorff mode was induced by a 5-minute infusion of cardioplegic solution (50–100 mL) through the aorta at 37°C and a constant pressure of 68 mm Hg. After arrest, the aorta was crossclamped at the completion of infusion with a plastic atraumatic aortic clip. Cardioplegia was replenished every 18 minutes with a 2-min infusion, after which the crossclamp was reapplied. After 2 or 6 hours of arrest with intermittent cardioplegic delivery, the heart was switched immediately to the working mode and reperfused with oxygenated, glucose-containing Krebs–Henseleit buffer at 37°C. The heart temperature during intermittent arrest ranged from 35°C during delivery to about 25°C before the next delivery (average 28°–30°C), as directly measured and discussed by Dobson and Jones.17
The working heart was chosen because the ejecting model is more representative of the natural flow through the heart, whereas the standard Langendorff model receives reversal of flow through the aorta and does no physical work.
Determination of Coronary Vascular Resistance During Warmer Intermittent Delivery and of Total Tissue Water
Coronary vascular resistance (CVR, Mdyne · s · cm–5) was calculated during each 2-minute cardioplegic delivery by dividing delivery pressure by flow (volume per second) according to the following equation: CVR = 1333 x pressure (in mm Hg) x 10–6/flow (in mL/s), where 1 mm Hg is equal to 1333 dyne/cm–2 and 10–6 is a conversion factor from dynes to megadynes.
Total tissue water (as a percentage) was determined by the difference in wet weight and dry weight divided by wet weight and multiplied by 100%. Powdered tissues were obtained from hearts receiving AL, AL with 1-mmol/L pyruvate, and AL with 5-mmol/L pyruvate. After 60 minutes of reperfusion, hearts were dried to a constant weight at 85°C for as long as 48 hours.
Statistical Analysis
All results are expressed as mean ± SEM. Statistics were performed separately for the 2-hour and 6-hour protocols. One-way analysis of variance was used to compare rats in weight, arrest times, time to first beat, heart rate, developed pressure, rate–pressure product, aortic flow, coronary flow, and cardiac output at separate time points (Table 1 and 2)
. Two-way analysis of variance with repeated measures was used to compare functional variables during 60 minutes of recovery across multiple time points for the different treatment groups (Figure 1
). Significance was then assessed with Bonferroni and Dunnet (2-sided) post hoc tests. The alpha level of significance for all experiments was set at P < 0.05.
|
|
|
| Results |
|---|
|
|
|---|
Cold Static Storage (4°C): Functional Recoveries After 2 and 6 Hours of Arrest
The functional data for the AL and Celsior groups undergoing cold immersion storage for 2 and 6 hours are shown in Tables 1 and 2, respectively. After 2 hours, there were no functional differences between the AL and Celsior groups. At 60 minutes of reperfusion in working mode, heart rates were 94% to 103% of prearrest values, systolic pressures 92% to 93%, diastolic pressures 99% to 106%, rate–pressure products 92% to 98%, aortic flows 65% to 70%, coronary flows 82% to 86%, and cardiac outputs 69% to 72% (Table 1).
After 6 hours of cold static storage (4°C), the hearts in the AL group had spontaneously returned to 105% of prearrest heart rate, 90% of prearrest systolic pressure, 105% of prearrest diastolic pressure, 94% of prearrest rate–pressure product, 66% of prearrest aortic flow, 84% of prearrest coronary flow, and 69% of prearrest cardiac output (Table 2). In contrast, hearts in the Celsior group had returned to significantly lower functional parameters after 60 minutes of reperfusion according to a 2-way analysis of variance with repeated measures (P = .006). Hearts in the Celsior group had returned to 81% of prearrest heart rate, 69% of prearrest systolic pressure, 93% of prearrest diastolic pressure, 63% of prearrest rate–pressure product, 41% of prearrest aortic flow, 47% of prearrest coronary flow, and 49% of prearrest cardiac output at 60 minutes reperfusion after 6 hours of static storage arrest (Table 2). Despite the same protocol of reattachment and rewarming of hearts (5 minutes) after cold static storage, hearts in the Celsior group took 5 minutes longer to reanimate in working mode than did those in the AL group (Figure 1, A) and showed early reperfusion arrhythmias relative to those in the AL group as well (data not shown). Hearts in the AL group had returned to a significantly higher cardiac output (45% higher) than had those in the Celsior group after 60 minutes of reperfusion after 6 hours of arrest (Figure 1, A).
Warmer Arrest With Intermittent Flushes (28°C–30°C): Cardioplegic Volumes, CVRs, and Recoveries After 2 and 6 Hours of Arrest
The total cardioplegic volumes for hearts with 0-, 1-, and 5-mmol/L pyruvate delivered with AL cardioplegia during the 2-hour arrest period were 222 ± 17, 287 ± 11, and 313 ± 15 mL, respectively; those with cardioplegia delivered during 6 hours were 519 ± 33, 509 ± 39, and 652 ± 26 mL. Hearts receiving AL supplemented with 5-mmol/L pyruvate had significantly higher total volumes infused than hearts receiving AL with either 0- or 1-mmol/L pyruvate (P = .014). The total cardioplegic volumes for hearts with Celsior delivered during 2 and 6 hours of arrest were 293 ± 20 mL and 411 ± 53 mL, respectively. Hearts receiving Celsior solution had 21% to 37% lower total volumes than did the AL groups, but these differences were not significantly different.
The values of CVR before cardioplegic arrest for hearts perfused with AL solution with 0-, 1-, and 5-mmol/L pyruvate and those perfused with Celsior were 0.32 ± 0.02, 0.35 ± 0.01, 0.33 ± 0.01, and 0.31 ± 0.02 Mdyne · s · cm–5, respectively (Figure 2 ). The prearrest CVRs were not significantly different. During 2 minutes of intermittent infusions, CVRs in the three AL groups increased by 1.3 times at 3 hours to 1.7 and 1.9 times at 6 hours (not significant, between AL groups). The CVR in the Celsior group increased 1.8 times (0.56 ± 0.08 Mdyne · s · cm–5) at 3 hours and 2.8 times (0.86 ± 0.17) at 6 hours. At 3 hours, the CVR values for the Celsior group were significantly higher than for AL with 5-mmol/L pyruvate (0.56 vs 0.36 Mdyne · s · cm–5) and AL solution alone (0.56 vs 0.42 Mdyne · s · cm–5; P = .027). Despite the Celsior group having 30% to 76% higher CVR at 6 hours than the AL groups, however, the differences failed to reach statistical significance, in part because of the large SEs of the Celsior group (Figure 2).
|
After 6 hours of intermittent cardioplegia and during 60 minutes of reperfusion, in hearts with AL alone recovery of prearrest heart rate was 95% ± 3%, recovery of prearrest aortic flow was 50% ± 3%, and recovery of prearrest coronary flow was 76% ± 4% values (Table 2). The addition of 1-mmol/L pyruvate to AL cardioplegia significantly increased recovery of aortic flow during the 60-minute reperfusion period (P = .016); however, neither heart rate nor coronary flow was significantly changed (Table 2). The increase in aortic flow in the presence of 1-mmol/L pyruvate was apparent at all reperfusion times (15, 30, 45, and 60 minutes; Table 2). Cardiac output (aortic flow plus coronary flow) was also significantly higher in hearts with AL in the presence of 1-mmol/L pyruvate (49 ± 4 mL/min) (P = .026) than in those with AL with 0-mmol/L pyruvate (36 ± 3 mL/min) or with 5-mmol/L pyruvate (37 ± 4 mL/min; Figure 1, B). Rate–pressure products for hearts perfused with AL with 0-, 1-, and 5-mmol/L pyruvate were 82%, 96%, and 90% of prearrest values and not significantly different from each other. Under identical 6-hour arrest conditions, hearts perfused with Celsior did not have return of a heart rate, developed pressures (4 mm Hg), and aortic and coronary flows and therefore had no cardiac output during the 60-minute reperfusion (Figure 1, B, Table 2). In direct contrast to the AL group, heart in the Celsior group were visibly small, hard, distorted, and discolored.
Values of total tissue water for AL-perfused hearts after 2 and 6 hours of cold static storage and 60 minutes reperfusion were 84% ± 1% and 86% ± 1%, respectively. For hearts in the Celsior group, the total tissue water values were 82% ± 2% and 84% ± 1% for 2 and 6 hours of cold static storage, respectively. After warm intermittent arrest and 60 minutes of reperfusion, the total tissue water values were 87% ± 1%, 88% ± 1%, and 87% ± 1% for AL with 0-, 1-, and 5-mmol/L pyruvate, respectively (not significantly different). The total tissue water for hearts in the Celsior group was 84% ± 4% and was not significantly different from the AL groups.
| Discussion |
|---|
|
|
|---|
Cold Static Storage for 2 and 6 Hours (4°C)
Currently, cold static storage is the most widely used form of preservation in heart transplant practice.3
In this study, we showed functional equivalence between AL cardioplegia and Celsior after 2 hours of static storage, with around 70% return of cardiac output (Table 1). After 6 hours of cold static storage, however, the AL group had significantly higher functional recovery values, with a 22% higher heart rate, 32% higher systolic pressures, a 46% higher rate–pressure product, a 48% higher aortic flow, a 45% higher coronary flow, and a 45% higher cardiac output (Table 2, Figure 1, A). A lower recovery in Celsior-treated hearts after 6 hours is in good agreement with the isolated working rat heart study of McDonald and colleagues,21
which showed a return of prearrest cardiac output of 22% ± 9% (15% aortic flow and 31% coronary flow) at 30 minutes of reperfusion after 6 hours of static storage at 2°C to 3°C. McDonald and colleagues21
further reported that the cardiac output increased to about 70% with the addition of cariporide and glyceryl trinitrate to Celsior. Surprisingly there are few isolated working heart studies in the literature comparing Celsior with other preservation solutions, because most researchers prefer to use Langendorff hearts, which perform no physical work (adenosine triphosphate turnover with zero work, i.e. force times vertical distance). High heart rates and 90% to 100% returns of prearrest developed pressures in nonworking Langendorff mode may not necessarily translate to improved pump function. The working rat heart study of Nickless and associates23
showed approximately 80% recovery of prearrest cardiac output (71% aortic flow and 93% coronary flow) after 5 hours of cold (2°C) immersion in University of Wisconsin solution. Unfortunately, these workers did not report functional recovery data beyond 15 minutes of reperfusion, precluding a direct comparison with AL-infused hearts during 60 minutes of reperfusion.
Another important difference between our study and previous studies using Langendorff or working rat heart preparations is that we induced arrest at 37°C, whereas others appear to have induced arrest at cold temperatures.21,23
To summarize, although functional recovery of AL-arrested hearts was superior to that of Celsior-arrested hearts after 6 hours of cold static storage, further studies are required to optimize the AL solution at these profoundly hypothermic temperatures. It is encouraging, however, that nondepolarizing, normokalemic AL in a physiologic, glucose-containing Krebs–Henseleit solution spontaneously returns good functional recoveries in the absence of an impermeant (eg, lactobionate, hydroxyethyl starch, mannitol) or a pharmacopeia of additives. Finally, another clinically relevant feature of AL cardioplegia, whether cold or warm, that deserves consideration is the spontaneous return of function without the need for defibrillation.17,24
Intermittent Flushes at Warmer Arrest Temperatures (28°C–30°C)
In this study, we showed that 2-minute top-ups after every 18 minutes of AL cardioplegia at 28°C to 30°C yielded spontaneous return of 80% of cardiac output after 2 hours and 55% cardiac output after 6 hours (Tables 1 and 2). Further, when AL cardioplegia was supplemented with 1-mmol/L pyruvate, the return of cardiac output increased from 55% to 75% after 60 minutes of reperfusion (P = .026); Table 2). Possible reasons that the addition of 1-mmol/L pyruvate improved aortic flow and cardiac output relative to 0- or 5-mmol/L pyruvate is difficult to reconcile without metabolic analysis. It is known that pyruvate is a potent oxidizable fuel for heart tissue, and has been shown to decrease the cytosolic lactate/pyruvate ratio (lower the ratio of reduced to oxidized nicotinamine adenoside), enhance the cytosolic ratio of adenosine triphosphate to adenosine diphosphate and inorganic phosphate, improve contractility, suppress hydroxyl free-radical production, and reduce oxidative stress.25-27
In contrast, extracellular Celsior storage solution failed to protect the heart after 6 hours at 28°C to 30°C (Table 1), with no cardiac output during 60 minutes of reperfusion (Table 2, Figure 1). Similarly, in 2004 we reported that St Thomas' Hospital solution performed poorly under identical conditions, with only 14% of hearts recovering function after 4 hours of arrest at 28° to 30°C.17
Ou and colleagues28
further reported that University of Wisconsin solution is not protective at warmer temperatures and may even be deleterious. To be fair, Celsior (or, for that matter, University of Wisconsin solution) was not designed for warmer arrest and storage temperatures; it was originally designed as a perfusion fluid during initial donor arrest, poststorage graft implantation, and early reperfusion.20
Static Cold Storage, Intermittent Flushes, or Continuous Perfusion?
Controversy abounds in the literature regarding the optimal perfusion dynamics and ionic and metabolic composition for arrest, storage, and reanimation of human donor hearts.1,2
Commonly used preservation solutions for cold static storage are the University of Wisconsin, Celsior, Euro-Collins, and Bretschneider solutions.8
Although intermittent flush techniques similar to the method used in our study (or continuous low-pressure infusion delivery during cold storage) are not widely practiced today, their superiority has been experimentally demonstrated during the past 20 years,11,29
as reviewed by Nickless and associates23
and Jahania and colleagues.1
The major clinical objections to intermittent flush or continuous perfusion methods appear to be based largely on logistics, and not on efficacy, although myocardial extracellular edema and associated decreased ventricular compliance have been a concern with constant-infusion storage techniques.2,30
Some of these limitations have been partially solved by Hassanein and coworkers31
and others who have developed portable perfusion apparatus for use in donor human beating-heart preservation. The apparatus, which incorporates a low-pressure infusion of a warm, oxygenated nutrient solution to the human donor heart, is currently undergoing clinical trials in the United Kingdom and Germany.
Possible Clinical Significance of the Normokalemic, Nondepolarizing AL Paradigm for Heart Transplant
This study, which showed the versatility of cold and warmer AL in a crystalloid composition, may be directly relevant to all phases of heart transplant (donor harvest, storage, and implantation). The particular focus of our work on heart arrest, protection, and preservation is intended to reduce the negative impact of cold-to-warm wash and reperfusion temperatures, during which major damage to the adult or pediatric allograft often occurs.7,8,28
Currently, there is no preservation solution that can preserve the functional human heart safely beyond 4 to 5 hours.
The versatility of AL infusion as the primary arrest and reanimation strategy may be as follows: (1) AL induces rapid electromechanical arrest (as seen in this study and in references 2, 17, and 24). (2) AL eliminates the need for high depolarizing potassium, which can lead to unnatural transmembrane voltages, ionic and metabolic imbalances, and electrical instability in myocytes,14,15
endothelial cells and vascular smooth muscle cells.12
High potassium is a potent vasoconstrictor and promotes vasospasm of the coronary arteries in diseased hearts.11
(3) Adenosine has the ability (through A1 receptor activation) to blunt the stimulatory effects of catecholamines,32
which may help to protect the heart during the harvest period.33
(4) AL maintains a lower CVR during prolonged storage (this study and references 17 and 24). (5) AL has antiarrhythmic properties that may be important to harvest, arrest, and reanimation34,35
and to sinus nodal protection. (6) AL has been shown to preserve high-energy phosphates (adenosine triphosphate and phosphocreatine) during no- or low-flow ischemia.36
(7) Both adenosine and lidocaine have potent anti-inflammatory37
and anticoagulant properties,38
and may help to reduce acute and chronic rejection. (8) AL arrest led to a spontaneous return of improved left ventricular function against physiologic workloads after 6 hours of arrest, with recovery as great as 75% of prearrest cardiac output (this study and reference 17). (9) AL versatility permits the incorporation of warmer harvest, preservation, and reanimation temperatures, which may reduce the adverse effects of low perfusate temperatures on myocardial ischemia tolerance, rheology, and endothelial dysfunction and may reduce the incidence of arrhythmias.11
(10) Finally, AL solutions may help to rescue and stabilize the heart and other organs during harvest from beating-heart and non–beating heart donors.
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
D. M. Rudd and G. P. Dobson Eight hours of cold static storage with adenosine and lidocaine (Adenocaine) heart preservation solutions: Toward therapeutic suspended animation J. Thorac. Cardiovasc. Surg., December 1, 2011; 142(6): 1552 - 1561. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Wu, P. Dong, C. Chen, J. Yang, and X. Hou The Myocardial Protection of Polarizing Cardioplegia Combined With Delta-Opioid Receptor Agonist in Swine Ann. Thorac. Surg., June 1, 2011; 91(6): 1914 - 1920. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. M. Rudd and G. P. Dobson Early reperfusion with warm, polarizing adenosine-lidocaine cardioplegia improves functional recovery after 6 hours of cold static storage J. Thorac. Cardiovasc. Surg., April 1, 2011; 141(4): 1044 - 1055. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. P. Dobson Membrane polarity: A target for myocardial protection and reduced inflammation in adult and pediatric cardiothoracic surgery J. Thorac. Cardiovasc. Surg., December 1, 2010; 140(6): 1213 - 1217. [Full Text] [PDF] |
||||
![]() |
K. L. Sloots and G. P. Dobson Normokalemic adenosine-lidocaine cardioplegia: Importance of maintaining a polarized myocardium for optimal arrest and reanimation J. Thorac. Cardiovasc. Surg., June 1, 2010; 139(6): 1576 - 1586. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |