JTCS Medtronic Endurant
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Akihiko Usui
Hideki Oshima
Toshiaki Akita
Yuichi Ueda
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kato, W.
Right arrow Articles by Ueda, Y.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kato, W.
Right arrow Articles by Ueda, Y.

J Thorac Cardiovasc Surg 2009;137:251-252
© 2009 The American Association for Thoracic Surgery


Brief Communication

Incomplete transmural ablation caused by bipolar radiofrequency ablation devices

Wataru Kato, MD*, Akihiko Usui, MD, Hideki Oshima, MD, Toshiaki Akita, MD, Yuichi Ueda, MD

Department of Cardiothoracic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan

Received for publication January 24, 2008; revisions received February 15, 2008; accepted for publication March 2, 2008.

* Address for reprints: Wataru Kato, MD, Department of Cardiothoracic Surgery, Nagoya University Graduate School of Medicine, 65, Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan. (Email: kwataru{at}med.nagoya-u.ac.jp).

Since the recent development of radiofrequency ablation devices, surgical ablation of atrial fibrillation has become more common.1-4Go We have recently adopted the Atricure bipolar radiofrequency clamp (Atricure, Inc, Cincinnati, Ohio) for surgical ablation. According to some reports, a bipolar radiofrequency system ensures transmurality compared with the unipolar system.1,2Go However, even when using a bipolar device an incomplete ablation can occur as a result of the thickness of the atrium wall or folding on itself2-4Go and thus can trigger a recurrence of atrial fibrillation. Because the pathologic sections of ablation lesions were occasionally obtained from an autopsy patient, we report a case of an incomplete ablation of the left atrium.

Clinical Summary

An 81-year-old man with aortic regurgitation and atrial fibrillation electively underwent aortic valve replacement and the left atrial maze procedure by using the Atricure clamp through a median sternotomy. The ablation was performed circumferentially on the orifice of the right and left pulmonary veins and the neck of the left atrial appendage by using the Atricure bipolar radiofrequency clamp during cardiac arrest. Each ablation was done twice to ensure transmurality. The generator of the radiofrequency device showed low and stabilized tissue conductance each time. After completing the ablation, the left atrial appendage was ligated. Cryoablation was also applied on the right atrium between the coronary sinus and isthmus of the inferior vena cava, and the aortic valve was then replaced with the 23-mm Medtronic Mosaic bioprosthesis (Medtronic, Inc, Minneapolis, Minn). The atrial fibrillation was converted into normal sinus rhythm after resuming the heartbeat. Early after surgical intervention, the patient once had a paroxysmal atrial fibrillation that was easily converted into normal sinus rhythm with medication. Except for this episode, the postoperative course had been uneventful until the third postoperative day. However, the patient had a mesenteric ischemia abruptly and died on the fifth postoperative day. A pathologic autopsy revealed massive intestinal necrosis. Because cardiogenic thromboembolisms were suspected, lesions of the radiofrequency ablation were also dissected to rule out the left atrial thrombus related to surgical ablation. The lesions were easily detected because of discoloration of the intima. On microscopic examination, the lesion of the neck of the atrial appendage showed transmural scar tissue, suggesting that the transmural ablation was complete (Go Figure 1). However, another section of the posterior wall of the left atrium showed an incomplete transmural ablation. Microscopic findings showed that the intima was thickened, probably by the ablation, but the normal myocardium of the left atrium partially remained among necrotic tissue on the thick atrial wall (Go Figure 2). No thrombus was found in the heart. The mesenteric arteries also revealed no thromboembolism. The pathologic diagnosis was nonobstructive mesenteric ischemia.


Figure 1
View larger version (185K):
[in this window]
[in a new window]

 
Figure 1. A microscopic section revealed that myocardium of the lesion disappeared and transmural ablation was completed (hematoxylin and eosin stain).

 

Figure 2
View larger version (149K):
[in this window]
[in a new window]

 
Figure 2. A microscopic section showed an incomplete transmural ablation. The thickened intima was observed, and the normal myocardium of the left atrium was partially remained (hematoxylin and eosin stain).

 
Discussion

The clinical effectiveness of bipolar ablation devices has been reported.1-4Go Bipolar devices have 2 jaws equipped with electrodes. By clamping the atrial tissue between the jaws, radiofrequency energy is delivered effectively to the tissue, and more precise transmural ablation is obtained than with unipolar types of devices. Because the conductance of the tissue clamped between the jaws of the device relates to the transmurality of ablation, the bipolar devices measure the tissue conductance between the jaws. A low and stabilized conductance is used as an indicator of transmural ablation.1Go However, cases have been reported in which the transmural ablation could not always be completed because of atrial wall thickness or folding in on itself, even when the generator of the device shows a low and stabilized tissue conductance.2-4Go Therefore some surgeons recommend repeated clump applications to ensure transmurality.3,4Go In line with such reports, we also made it a practice to apply the clamp twice on each lesion. However, an incomplete transmural lesion was observed. In fact, the patient's rhythm was successfully converted into normal sinus rhythm. However, the patient had paroxysmal atrial fibrillation after surgical intervention. The incomplete ablation might have caused the recurrence. Wall thickness is sometimes observed, and an inappropriate application can take place as a result of folding of the atrial wall, particularly in the posterior wall of the left atrium during pulmonary vein isolations. Pacing on pulmonary veins is a good way to confirm whether conduction block is obtained, and repeated ablation reduces the risk of incomplete ablation.1,3Go Therefore we strongly recommend that all lesions should be tested by pacing on pulmonary veins to ensure complete surgical ablation.

References

  1. Prasad SM, Maniar HS, Schuessler RB, Damiano Jr. RJ. Chronic transmural atrial ablation by using bipolar radiofrequency energy on the beating heart. J Thorac Cardiovasc Surg 2002;124:708-713.[Abstract/Free Full Text]
  2. Bugge E, Nicholson IA, Thomas SP. Comparison of bipolar and unipolar radiofrequency ablation in an in vivo experimental model. Eur J Cardiothorac Surg 2005;28:76-82.[Medline]
  3. Gillinov AM, McCarthy PM. Atricure bipolar radiofrequency clamp for intraoperative ablation of atrial fibrillation. Ann Thorac Surg 2002;74:2165-2168.[Abstract/Free Full Text]
  4. Benussi S, Nascimbene S, Calori G, Denti P, Ziskind Z, Kassem S, et al. Surgical ablation of atrial fibrillation with a novel bipolar radiofrequency device. J Thorac Cardiovasc Surg 2005;130:491-497.[Abstract/Free Full Text]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Akihiko Usui
Hideki Oshima
Toshiaki Akita
Yuichi Ueda
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kato, W.
Right arrow Articles by Ueda, Y.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kato, W.
Right arrow Articles by Ueda, Y.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS