JTCS KCI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Masashi Kai
Michiya Hanyu
Yoshiharu Soga
Hitoshi Okabayashi
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kai, M.
Right arrow Articles by Okabayashi, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kai, M.
Right arrow Articles by Okabayashi, H.
Related Collections
Right arrow Great vessels

J Thorac Cardiovasc Surg 2009;137:503-504
© 2009 The American Association for Thoracic Surgery


Brief Communication

Midterm patency rate after saphenous vein grafting with a PAS-Port device

Masashi Kai, MD*, Michiya Hanyu, MD, Yoshiharu Soga, MD, Takuya Nomoto, MD, Jota Nakano, MD, Takehiko Matsuo, MD, Masahide Kawato, MD, Hitoshi Okabayashi, MD

Department of Cardiovascular Surgery, Kokura Memorial Hospital, Fukuoka, Japan

Received for publication December 5, 2007; revisions received January 29, 2008; accepted for publication March 2, 2008.

* Address for reprints: Masashi Kai, MD, Department of Cardiovascular Surgery, Kokura Memorial Hospital, 1-1 Kifunemachi Kokurakita-ku, Kitakyushu, Fukuoka, 8020073 Japan. (Email: m-kai{at}db4.so-net.ne.jp).

Recently, a new proximal anastomosis device of a saphenous vein graft (SVG) to the aorta, the PAS-Port device (Cardica, Redwood City, Calif) has been introduced and yielded encouraging results in terms of neurologic complications and early patency.1,2Go However, there is a concern about the midterm (at least 1 year after surgical intervention) patency rate. The aim of this study was to evaluate the midterm patency rate of SVGs whose proximal anastomosis was performed with the PAS-Port device.

Clinical Summary

Between January 2004 and September 2006, 69 PAS-Port devices had been used in 66 patients undergoing SVG proximal anastomosis in coronary artery bypass grafting (CABG) at Kokura Memorial Hospital. Sixty-three patients had off-pump grafting, and 3 patients had on-pump beating-heart grafting. The details of the operative data are summarized in Go Table 1. Bilateral internal thoracic artery grafting for the left coronary territory was our standard method. The gastroepiploic artery was our first choice for revascularization of the right coronary artery territory. We used SVGs when (1) stenosis of the native coronary artery was mild (<90%), (2) arterial conduits had already been used in previous operations, (3) emergency operations were necessary, and (4) the patient had a prior history of gastrointestinal disorders. The proximal anastomosis devices were used basically in case the ascending aorta showed atheromatous changes on an epiaortic echocardiogram. Additional 4-0 Prolene purse-string stitching around the deployed device was performed in 15 (21.7%) of 69 devices to control the bleeding. No patients had difficulty achieving the hemostasis. All the operations were performed by one experienced surgeon. Every patient was given a subcutaneous heparin injection on postoperative days 1 to 4 to prevent postoperative stroke and perioperative myocardial infarction. Oral aspirin was started on postoperative day 1 and continued throughout the follow-up period. No 30-day mortality or intraoperative stroke was observed. Six patients died within 1 year after the operation. Among them, 2 deaths were due to cardiac causes: congestive heart failure (n = 1) and sudden death (n = 1). The other 4 deaths were due to noncardiac reasons: cancer (n = 2), sepsis (n = 1), and liver failure (n = 1). Of 46 midterm survivors (at least 1 year after surgical intervention), 38 (82.6%) consented to late follow-up graft evaluation by means of 3-dimensional computed tomography. Two of 39 devices were occluded, and the 1-year patency rate (FitzGibbon grade A) was 94.9%. No obvious stenosis of SVGs (FitzGibbon grade B) was observed. Of the 38 patients who underwent late graft evaluation, 24 did so at least 2 years after surgical intervention. The 2-year cumulative patency rate was 91.7% (22/24). All the results were evaluated by an experienced radiologist. Details of the occluded SVGs are given in Go Table 2.


View this table:
[in this window]
[in a new window]

 
Table 1 Operative data (n = 66)
 

View this table:
[in this window]
[in a new window]

 
Table 2 Details of the occluded saphenous vein grafts
 
Discussion

Stroke is a devastating complication of CABG. Manipulation of the aorta using techniques such as crossclamping is thought to be a predisposing risk factor. The off-pump technique has brought more attention to reduce this devastating complication. Use of an aortic side clamp requires aortic manipulation, thereby precluding the major advantage of the off-pump technique. Several devices for proximal anastomosis of SVGs to the aorta have been developed and can facilitate clampless proximal anastomosis. Although the results have been satisfactory in terms of neurologic complications, there have been some concerns about early and long-term patency rates. The early patency rate of the previous generation of the proximal anastomosis device, the Symmetry device (St Jude Medical, Inc, Minneapolis, Minn), was satisfactory, but production was discontinued because of the poor midterm and long-term results.3-5Go The PAS-Port device has the potential to yield better results than the Symmetry device for the following reasons: (1) the stents were located outside and not inside the SVG, which did not reduce the total amount of blood exposed to nonintimal surfaces inside the aortic lumen, and (2) the stents were composed of 316L medical grade stainless-steel and not nitinol, which can cause intimal hyperplasia.1Go

We realize that the gold standard for the evaluation of graft patency is angiography. It is relatively difficult to assess the details of anastomosis sites with computed tomography. Therefore we might have missed a number of stenotic vessels. In addition, this is a very small cohort of patients.

In conclusion, this study demonstrated the satisfactory results of midterm patency rate after placement of SVGs with a PAS-Port device. This device could be useful for CABG in case the ascending aorta showed the severe atheromatous change to a degree that precluded the use of a side clamp. However, a larger-scale study and a longer follow-up period will be mandatory to confirm the reliability of this device.

References

  1. Gummert JF, Demertzis S, Matschke K, Kappert U, Anssar M, Siclari F, et al. Six-month angiographic follow-up of the PAS-Port II clinical trial. Ann Thorac Surg 2006;81:90-96.[Abstract/Free Full Text]
  2. Lahtinen J, Biancari F, Ojala R, Mosorin M, Cresti R, Rainio P, et al. Prospective, randomized study of the use of the cardiac PAS-Port aortic connector system in off-pump coronary artery bypass surgery. Heart Surg Forum 2006;9:E568-E571.[Medline]
  3. Kitamura H, Okabayashi H, Hanyu M, Soga Y, Nomoto T, Johno H, et al. Early and midterm patency of the proximal anastomoses of saphenous vein grafts made with a Symmmetry Aortic Connector System. J Thorac Cardiovasc Surg 2005;130:1028-1031.[Abstract/Free Full Text]
  4. Reuthebuch OT, Kadner A, Lachat ML, Turina MI. Graft occlusion after deployment of the Symmetry bypass system. Ann Thorac Surg 2003;75:1626-1629.[Abstract/Free Full Text]
  5. Lahtinen J, Biancari F, Mosorin M, Heikkinen J, Rainio P, Juvonen TS, et al. Fatal complications after use of the symmetry aortic connector in coronary artery bypass surgery. Ann Thorac Surg 2004;77:1817-1819.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
S. Demertzis, R. Trunfio, F. Faletra, R. Wyttenbach, and F. Siclari
Sutureless Proximal Anastomosis Using the PAS-Port System: Six-Month Patency and Five-Year Follow-Up in "All-Comers"
Ann. Thorac. Surg., November 1, 2010; 90(5): 1507 - 1513.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
Y. Takahashi, Y. Tsutsumi, O. Monta, and H. Ohashi
Aorta non-touch coronary artery bypass grafting after total arch replacement for acute type A aortic dissection
Interact CardioVasc Thorac Surg, November 1, 2009; 9(5): 906 - 908.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Masashi Kai
Michiya Hanyu
Yoshiharu Soga
Hitoshi Okabayashi
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kai, M.
Right arrow Articles by Okabayashi, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kai, M.
Right arrow Articles by Okabayashi, H.
Related Collections
Right arrow Great vessels


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS